| 1 | 1₹28.5 CrAccepted-AOC N H NO 6 BAMBHORI JALGAON MAHARASHTRA 425001 | JALGAON | MAHARASHTRA | 425001 | ₹28.5 Cr | 1 | Accepted-AOC Lowest |
| 2 | 2₹31.5 CrRejected-AOC | ₹31.5 Cr | 2 | Rejected-AOC Higest |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹31.7 Cr
EMD Value
₹63.5 L
Closing Date
10 Aug 2020, 3:00 pmClosed
Executive Engineer
PHED, Charkhi Dadri
Construction of 1 No. Pump Chamber, 1 No. Collecting tank, at Jhajjar Road STP, Laying of 37700 Mtr Long HDPE pipe rising main from Chirya Road STP to Jhajjar Road STP and further up the drain No.8 etc.
2020_HRY_135989_1
SE Endst. No. 8913 dated 03.07.2020.
Open Tender
Civil Works
1825 days
PHED Charkhi Dadri
Refer to tender documents and as per DNIT.
2 documents required · 2 mandatory
₹20,000
Execitive Engineer
₹63.5 L
22 Sept 2020
17 Jul 2020
10 Aug 2020
17 Jul 2020
10 Aug 2020
17 Jul 2020
Amount
Supply & Eraction of non-clog sewage submersible pumping sets with all accessories complete in all respect as per specifications mentioned in the DNIT CHIRIA ROAD STP 4700 LPM X 40 M. Head
3200 LPM X 40 M. Head
1600 LPM X 40 M. Head
HORIZONTAL CENTRIFUGAL PUMPING MACHINERY Supply & Eraction of non clog sewage Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as per specifications mentioned in the DNIT JHAJJAR ROAD STP 9350 LPM X 90 M. Head
6300 LPM X90 M. Head
3200 LPM X 90 M. Head
PANEL BOARDS FOR MOTORS Supply, erection, testing & commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400 mm deep having follwing items For 1 no Pumping Sets of 4700 LPM x 40 m Head a) Main switch 150 amp. 1 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 4700 LPM x 40 m Head = 1 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 1.1.1
For 2 no Pumping Sets of 3200 LPM x 40 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 3200 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 1.1.2
For 2 no Pumping Sets of 1600 LPM x 40 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 1600 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 1.1.3
For 2 no Pumping Sets of 9350 LPM x 90 m Head a) Main switch 600 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 9350 LPM x 90 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 2.1.1
For 2 no Pumping Sets of 6300 LPM x 90 m Head a) Main switch 400 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 6300 LPM x 90 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 2.1.2
For 2 no Pumping Sets of 3200LPM x 90 m Head a) Main switch 200 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 3200LPM x 90 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 2.1.3
Supply, erection, testing IS marked copper wire for various motors with underground system in PVC and flexible pipes copper wire 3 core complete in all respevts with accessories like thimble etc. i) 6mm2 3core
ii) 10mm2 3core
iii) 16mm2 3core
iii) 25mm2 3core
iii) 70mm2 3core
iv) 185mm2 3core
Sluice Valves / NRV & specials for Pumping Machinery Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 as per DNIT specification on the pumping machinery & head works including cost of jointing material (IVC / VAG make) 150 mm i/d
Supplying, fixing of DI swing check type reflux (Non returned valve ) PN 1.6 if IVC/VAG make 150 mm i/d
Supply & Fixing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect. 150 mm i/d
DI D/F Pipes. 150 mm i/d
Sluice Valves/ Specials For Rising Mains Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 as per DNIT specification on the pumping machinery & head works including cost of jointing material (IVC / VAG make) For Rising main lines 350 mm i/d
Supply & Fixing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect. 350 mm i/d
Providing & fixing of D.I. Kinetic Air Valve soft seated as confirming to I.S.I. complete in all respect. 80mm
Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic meters per minutes, complete in all respect.
Supply erection & testing of Ceiling fan of size 48" i/d (1200 mm) of reputed ISI make complete in all respect.
Providing and fixing of insulated Rubber matting suitable for HKV installation 1 meter x 2 meter x 12 mm as per specification.
Supplying and fixing of Gantry with chain pulley block of following capacity with traveling trolley of appropriate lifting capacity for handling of pumping sets capable of moving along the girders to be provided in the pump house complete in all respects as per specifications approved by Engineer-in-Charge. 3 Ton Capacity at Jhajjar road STP
2Ton Capacity at Chiria road STP
Supply erection testing and commissioning of Flow Meter (KRONE Make) with digital display of 150 mm i/d complete in all respect.
NH Crossing by 650 mm i/d MS casing pipe for 500 mm DN carrier pipe line Boring /excavation including pit making at entry & exit point to the precise dimensions for the Launch of the specialized Auger boring machine in normal soil condition but not in Rock/Bolders/ any underground utility like foundation, water supply line coming in alignment or other underground obstructions complete in all respect including caution sign boards, signals, watching fencing, site clearance etc. i) For M.S. Pipe 650 mm i/d 8 mm thick casing pipe.
Providing & insertion of 650 mm i/d M.S. Casing pipe 8 mm thick (Fe- 330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following sizes including cutting, beveling, grinding & radio graphically welding of pipes as per IS-1182 complete in all respect and also coating of inner & outer surface of casing pipe with high built epoxy paint to R.D.S.O. as per specification No. M&C/PCN.III/88 to a dry film thickness of 250 micron for protection against corrosion complete in all respect including cost & cartage of material to site of work and testing as per DNIT i) For 650mm i/d M.S. casing pipe 8 mm thick.
Providing & Insertion of water supply pipeline 500 mm i/d M.S. pipe (Fe- 330 grade) fabricated as per IS:3589 of 1991, from steel plates conforming to IS:2062, 8 mm thick by providing Roller arrangement for smooth insertion & anchoring of pipe through out the length with HDPE spacers at a distance of 2 meters apart to avoid contract of carrier pipe including cutting, jointing, radio graphically welding as per IS:1182 Hydraulic testing complete in all respect and also with cement mortar lining 12.5mm thick on inner surface including cost & cartage of material to site of work i) M.S. pipe 500 mm i/d 8 mm thick
Providing concrete block 1:1-1/2:3 on both ends to plug the annular space between casing and carrier pipe for 750mm i/d casing & 600 mm i/d carrier pipe complete in all respect
Provision for probe radar survey to check any underground obstruction before finalizing the alignment.
Providing and fixing of Hydrants on 355 mm DN and 500 mm DN HDPE pipe lines including DI delivery pipe, sluice valve, bend, reducer and all other material which ever required, labour, loading unloading, transpostation etc and 1 no. brick Hodi measuring 1.5 x 1.5 x 1.5 m complete in all respect.
Design, Supply & Erection of 2 no. copper wound Transformer of 100 KVA & 400 KVA on load tap changer or suitable capacity on higher side of standard make outdoor type, VCB Panel, G.O. Switch, H.T. Metering Panels, APFC Panels along with for each Transformer, 11KV Substation, entire cable network from G.O. Switch to H.T. Metering equipment and from H.T. Metering to Transformer Main to L.T. Panel, Earthing, safety equipment and any other contingent thereto complete in all respect as per DNIT and getting it passed from Chief Electrical Officer including operation & Maintenance of 5 Years. At Chiria Road STP = 100 KVA
At Jhajjar Road STP = 400 KVA
Design, Supply & Erection of 2 No. DG Sets of 100 KVA & 500 KVA suitable capacity on higher side capacity with Acoustic Canopy, AMF Panel and Copper Earthing of suitable rate with change over switch & synchronizing panel complete as per DNIT including operation & Maintenance of 5 Years. At Chiria Road STP = 100 KVA
At Jhajjar Road STP = 500 KVA
Operation & Maintenance Operation and maintenance after completion of successful trail run period of 3 months & 5 Year thereafter. i) Operation & maintenance during 1st Year. (Defect liability period)
ii) Operation & Maintenance during 2nd year
iii) Operation & Maintenance during 3rd year
iv) Operation & Maintenance during 4th year
v) Operation & Maintenance during 5th year
Bidder Name
Amount
Jain Irrigation Systems Limited
ANAND KUMAR - STL
Jain Irrigation Systems Limited
ANAND KUMAR - STL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid