Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.3 Cr+₹7.7 L (6.10%)Rejected-AOC 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | ₹1.3 Cr+₹7.7 L (6.10%) | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹1.4 Cr+₹12.3 L (9.72%)Rejected-AOC NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | ₹1.4 Cr+₹12.3 L (9.72%) | L3 | Rejected-AOC NOT BEING LOWEST |
| 4 | L4₹1.5 Cr+₹22.3 L (17.6%)Rejected-AOC | ₹1.5 Cr+₹22.3 L (17.6%) | L4 | Rejected-AOC NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
15 Mar 2025, 6:00 pmClosed
COL MANOJ NEGI
CWE AF NORTH BANGALORE BELLARY ROAD JC NAGAR POST BANGALORE 560006
PROVN OF GRANITE TOP WITH SS RAILING AND VIEW CUTTERS, STORE,KOTA STONE IN STAIRCASE, RECHARGE PITS, GYMNASIUM, NON-CLOGGING PUMP WITH ANCILLARIES AND COVERED SHED FOR STORAGE AND SPECIAL REPAIR TO LT PANELS AT VARIOUS LOCATIONS UNDER GE (AF) MARATH
2025_MES_696480_1
87578CWEAFNMAR
Open Tender
Civil Works
Item Rate
270 days
GE (AF) MARATHAHALLI
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) MARATHAHALLI
₹2.1 L
Yes
21 May 2025
5 Feb 2025
17 Mar 2025
6 Feb 2025
15 Mar 2025
3 Mar 2025
6 Feb 2025 - 19 Feb 2025
Amount
M & L for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, multi stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for one light point /Fan point/ Bell Point controlled by one switch.
All as per item No 1 above but for One 5 Amps socket point on independent board.
All as per item No 1 above but for point wiring complete with 2.5 Sqmm as earth wire for 3 pin 15A socket multipurpose on independent board .
S & F of modular switch 06 Amps 1 module complete all as specified & directed
S & F modular socket 06 Amps 2/3 pin, 2 module complete all as specified & directed.
S & F High Speed Pedestal fan, floor mounted single phase Pedestal Fan, Superior Low Voltage Performance, 450 mm sweep strong & stable base for Stability, 3 Speed Control, Jerk Free Oscillation, smooth swing operation, White sprint Colour, noise level 73.4 dB, Wattage 110 Watts, Finish Type- Glossy complete all as specified and directed
S & F exhaust fan plastic body 300 mm sweep including all fittings connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and directed
S & F modular socket 06/16 Amps 2/3 pin 2 module complete all as specified & directed.
S & F MCB SPN 32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB DB SPN 4 Way with 200 Amps rated busbar, double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
S & F LED light fittings 1x20 watts, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories complete all as specified & directed.
M & L ceiling rose surface type, 65mm x 50mm, three terminals, 3 phase / PVC / polycarbonate isolated body all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified & directed.
M & L for excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete all as specified and directed.
M & L removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified and directed.
Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified & directed.
M & L for Brick protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified & directed.
M & L for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode of size 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earth lead wire 4.0 mm dia by means of galvanized bolts, nuts, washers and brazed properly with connected to earth test point & to main switch board, LT panel etc with & including adequate quantity of charcoal dust and common salt around earth plate, PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with pre cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified & directed. Note- The unit rate includes main earthing lead GI earth wire 4.0 mm dia with 40 mm dia GI light grade earth lead protection pipe from earth electrode to test point up to 7.5 mtr.
M & L for Pre-cast cement concrete block masonry with solid blocks type C1 1:3:6 (20mm graded aggregate) , exc. 10 cm in width and setting in cement mortar (1:4), complete all as specified and directed.
M & L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified
S & F Steel work in tubular trusses (framed and curved) including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 all as specified and as directed.
S & F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment as in gusset plate conforming to Fe- 410-W-(Gde-E-250) quality A etc complete all as specified & directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet (curved) 0.50mm thick of an colour directed by GE, having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
M & L for painting to steel & iron surfaces two coats of synthetic enamel paint over a priming coat of red oxide including preparation of surface all as specified and directed.
M & L for 75 mm thick PCC 1:4:8 (40 mm graded aggregate) type D2 as in sub- base of floor complete all as specified and directed.
M & L for 100mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floors and pavings etc, finishing with spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green, complete all as specified & directed.
Demolition and dismantling of reinforced cement concrete ( reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M & L for providing, precast cement concrete type B1 1:2:4 (20 mm graged aggregate) as in manholes cover slab, etc.(of any section indicated), with plain fair faces, including chamfer weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match complete all as specified & directed.
M & L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for Concrete bed to 200mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 all as specified and directed.
S & F 200 mm dia reinforced concrete pipes, class NP2, laid, jointed and testing complete with collars complete all as specified and directed.
M & L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing, benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 200 mm dia SWG pipe all as specified and directed.
M & L for PCC 1:2:4 type B-1(using 20 mm graded stone aggregate) as in surface channels/benching of manhole, drain, laid to shape and slope and surfaces finished even and smooth using extra cement, complete etc all as specified and directed.
S & F MS rolled section angle/square conduit/flat iron of any size as in purlins, Column, rafter, wind tie connected to common rafters fixed with angle cleats with necessary bolts & nuts and other connecting materials required to connect complete all as specified & directed using mild steel Fe 410-W (Gde-E-250 quality A).
M & L for Surface excavation not exceeding 30cm deep and averaging 15cm dep and getting out in soft/loose soil complete all as specified & directed.
M & L for Moorum filling in floors or pavings laid in layers n.exc 15 cm thick spread, levelled and rammed including watering etc all as specified and directed.
M & L cement concrete 75mm thick type B- 0, 1:2:4 (12.5mm graded agg) as in floor finishing cement concrete surface even and smooth without using extra cement complete all as specified & directed.
S & F Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles complete all as specified & directed.
Supply, install testing and commissioning of submersible sewage non clog pump of capacity 5 HP/3.70 KW motor, havng delivery pipe of size 65 mm, rated voltage 415 Volt, Speed RPM 2900, 3 phase, 50 Hz frequency, Head maximum 23.5 mtr, discharge maximum 20 LPS, including suitable starter MK1/MLO including necessary electrical connections from starter to motor with suitable size submersible cable complete all as specified & directed. Make : kirloskar or equivalent.
S & F of PVC insulated & PVC sheathed industrial copper cable for submersible pump motors, flat three core of nominal area of conductor 4 sqmm, 1100 Volts, conforming to IS: 694 including taking down old U/S cable complete all as specified and directed.
Supply, fixing, laying and commissioning of 3 layer PP-R polypropylene random co polymer concealed pipes SDR 7.4 (PN 16) UV stabilized having dia 75 mm having antimicrobial fusion welded having thermal stability for hot and cold water supply, all PP-R plain and brass threaded poly propylene random fittings laid in trenches complete all as specified as directed
Disconnecting all Electric connections and taking down old existing LT panel including MCCB of any size and supply, installation, testing and commissioning of outdoor type KIOSK panel board suitable for 3 phase 4 wire 415 V, 50 Hz and tested at CPRI for 415 volts factory fabricated in an approved factory having modern fabrication process, powder coating in approved shared having thickness not less than 100 microns, provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS : 8623/93 comprising, the outer shell shall be made out of 3 mm thick CRCA sheet and MS angle section 40x40x6 mm base frame factory fabricated with front and back openable, double door system lockable/ openable, the bottom of the outer shell contains a detachable plate having size with glands, the outer shell shall be mounted on stand having zine coating not less than 80 microns, provision of threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made, the degree of protection of outer shell shall be IP - 54, inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, TPN Copper bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB, the TPN bus bar shall be insulated with colour coded heat shrinkable sleave, all control wires shall be with 2.5 sqmm multi strand copper conductor and shall be propely bunched, tied, ferruled for proper identification and crimped with adequate size of lugs of suitable length including PCC (1:3:6) type C-2 as in foundation of suitable size (30 cm below ground level & 40 cm above ground level) including necessary excavation and earth work complete all as specified and directed. (NOTE: Rate of earthwork and PCC are deemed to be inclusive in this item LT panel shall be embedded in PCC foundation of size as required in cement mortar 1:6 and plastering the same in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed ) INCOMING (a) MCCB 4 pole 400 A 50 KA 415 Volts - 1 No. (b) Intelligent AC digital display three phase, LCD ammeter 0 to 500A and voltmeter 0 to 500V with CT. (c) Indication lamp RYB set of 03 -01 No OUTGOING (a) MCCB 4 pole 100 Amps 25 KA 415 Volt - 5 Nos (b) MCCB 4 pole 200 Amps 25 KA 415 Volt - 2 Nos
Disconnecting all Electric connections and taking down old existing LT panel including MCCB of any size and supply, installation, testing and commissioning of outdoor type KIOSK panel board suitable for 3 phase 4 wire 415 V, 50 Hz and tested at CPRI for 415 volts factory fabricated in an approved factory having modern fabrication process, powder coating in approved shared having thickness not less than 100 microns, provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS : 8623/93 comprising, the outer shell shall be made out of 3 mm thick CRCA sheet and MS angle section 40x40x6 mm base frame factory fabricated with front and back openable, double door system lockable/ openable, the bottom of the outer shell contains a detachable plate having size with glands, the outer shell shall be mounted on stand having zine coating not less than 80 microns. Provision of threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP - 54, inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, TPN Copper bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB, the TPN bus bar shall be insulated with colour coded heat shrinkable sleave, all control wires shall be with 2.5 sqmm multi strand copper conductor and shall be propely bunched, tied, ferruled for proper identification and crimped with adequate size of lugs of suitable length including PCC (1:3:6) type C-2 as in foundation of suitable size (30 cm below ground level & 40 cm above ground level) including necessary excavation and earth work complete all as specified and directed. (NOTE: Rate of earthwork and PCC are deemed to be inclusive in this item LT panel shall be embedded in PCC foundation of size as required in cement mortar 1:6 and plastering the same in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed ) INCOMING (a) MCCB 4 pole 400 A 50 KA 415 Volts - 1 No. (b) Intelligent AC digital display three phase LCD ammeter 0 to 500A and voltmeter 0 to 500V with CT. (c) Indication lamp RYB set of 03 -01 No OUTGOING (a) MCCB 4 pole 100 Amps 25 KA 415 Volt - 2 Nos. (b) MCCB 4 pole 200 Amps 25 KA 415 Volt - 3 Nos
M & L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate in foundations filling and mass concrete complete all as specified and as directed.
S & F in replacement of GI tubing, light grade, 100 mm bore with all fitting laid in trenches / pole / wall for protection of cables complete all as specified & directed.
M & L for boring of holes under roads, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe upto 150mm dia suitable for .4 mpa working pressure complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified & directed.
All as per item No 49 above but for size 185 sqmm 3.5 core
S & F of Nature switch (using infra red sensor technology )based automatic street light control panel, this panel should be suitable enough to 3 phase load of 5 KW. Nature switch operation should be based on natural light lux level. Required illuminance level for switching ON is < 60 Lux & for switching off > 10 lux. The sensor alongwith suitable power contactors and incoming outgoing MCB should be enclosed in a pole /wall mounted rust proof ,electric shock, termite proof and FR grade SMC enclosure conforming to IP 54, the circuit should also have a provision for manual operation (i.e sensor bypass option) .The nature switch must have 3 phase load of 5 KW with 3 nos incoming outgoing MCBs of 16 -20 Amps & 3 nos contactors (single pole /2/ pole/3 pole ) of 16-20 Amps & circuit wiring (copper )10 mm2 complete all as specified and as directecd :Make : Swadeep & equivalent.
S & F of 4 Pole MCCB 500 to 630 Amp, thermal and magnetic release 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified and directed.
S & F of 4 Pole MCCB 320 to 400 Amp, thermal and magnetic release 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
S & F of 4 Pole MCCB 200 to 250 Amp, thermal and magnetic release 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description & in any position etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each all as specified and directed
M & L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. Rough finished surfaces of concrete, complete all as specified and directed.
M & L for PCC Type B0 1:2:4 (12.5mm graded aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed.
M & L TMT mild steel bar but 6mm to 8mm dia. cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
S & F of 1 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as directed.
S & F of 150mm bore UPVC pipes (Sch - 40) including fittings, jointing, fixed to walls complete all as specified and directed.
M & L for providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified & directed.
M & L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & directed.
M & L for providing and fixing factory made UPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding mesh sash (42mm x 57mm), sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified & directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) for Area exceeding 2.00 sqm each
S & F false ceiling grid of size 600 x 600 mm system using hot dipped galvanized steel section with precoated capping, main tee of size 24x32 mm having 0.27mm thick at every 1200mm centre to centre, cross tee of size 24x27 mm having 0.25mm thick at 600mm centre to centre and wall angle of size 19x19 mm having 0.35 mm thick fixed to the periphery of the wall, and suspended at every 1200mm centre to centre in both directed using 2.00 mm thick GI wire and fixing 600 x 600 x 16 mm mineral fibre ceiling tiles of Classic lite RH99 complete all as specified and as directed.
M & L fo 100 mm thick Cement concrete , type B-0, 1:2:4 (20 mm graded aggregate) on sub floors Finishing cement concrete surface even and smooth, Using extra cement complete all as specified & directed.
M & L for preparation of Old surface of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paint including one coat of Birla white putty on plastered surfaces etc including complete removal of existing surfaces of any etc. complete all as specified & directed.
M & L for PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate as in coping, mud stops, benching, water tank platform etc. on roof, chajja weathering, slightly rounded or chamfered angles and throating etc. including necessary form work complete all as specified & directed.
M & L for Granite (of any type) slabs/tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 20mm thick Screed bed or bedding layer for laying floor finishes in CM 1:4 etc complete all as specified & directed.
M & L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:3 etc complete all as specified & directed.
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M & L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates, chain etc., including welding, grinding, buffing, polishing and making curvature (whereever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including cutting of tile complete all as specified and directed.
M & L for Excavating in postholes in Hard/dense soil (or similar holes) each n.exc 0.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm, watering and removing surplus soil to a distance n.exc 50 mtr & making good to surface, getting out in soft / loose soil all as specified and directed.
S & F 6 mm thick poly carbonate sheet, plain colour, fixed with self tapping screw, incluidng PVC beading on joints, approved pattern in blue and white colour, complete all as specifed and directed.
M & L for surface excavation n.exc 30 cm deep and averaraging 15 cm deep and getting out Hard/dense soil complete all as specified & directed.
M & L for Mild steel TMT bars 8mm dia and over cut to length bent to shape required including cranking, stirups, bending and binding with and including mild steel wire annealed not less than 0.9 mm dia or securing with clips confomring to Gd I, IS-432 complete all as specified & directed.
M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M & L for reinforced cement concrete (Desing mix) M-25 (20 mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M & L for reinforced cement concrete (Desing mix) M-25(20 mm graded aggregate) Columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for reinforced cement concrete (Desing mix) M-25 (12.50 mm graded aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brickwork or concrete surfaces CM (1:6) finished even and smooth with using extra cement with wpc complete all as specified and directed.
M & L for sand filling and spreading and levelling n exc.25 cm thick in floor or foundation including watering and consolidation complete all as specified and directed.
M & L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc. including provision of binding wire complete all as specified and directed
Supplied only chain link MS galvanised fencing of any size or type complete all as specified and directed
M & L for running welding in repairs, thickness of metal to be welded exc 9 mm but n,exc 20mm, complete all as specified and directed.
M & L for welding in repairs, exc 2.5cm but n.exc 5cm in length, on thickness of metal to be welded exc 9 mm but n,exc 20mm, complete all as specified and directed.
M & L for taking down cement plaster on brick/stone wall and ceiling including raking out joints, hacking for key, scrubbing down with water etc all as specified and as directed.
M & L for roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove dust, brushing neat cement slurry with 3.0kg of cement per sq. metre etc complete all as specified and directed.
M & L for Mirror polished Machine cut kota stone slab flooring 20-25mm thick in steps of flooring over cement screed base laid, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20mm thick screed bed in CM 1:4 and three Horizontal lines should be made to avoid skidding over steps all as specified and as directed
M & L for Mirror polished Machine cut kota stone slab in steps of flooring 20-25mm thick in Riser of steps, skirting, dado and pillar laid over cement screed and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat in cement mortar 1:3 all as specified and as directed
Demolition of Brickwork or stone/boulder masonry, built in Cement mortar/cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
M & L for brick work with sub class B brick straight or curved on plan exc 6 M mean radius built in cment mortar 1:6 complete all as specified and as directed.
M & L for Pre-cast cement concrete laid in cement mortar (1:6) type C1 1:3:6 (20mm graded aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified and directed.
M & L for Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces including finishing even and fair. complete all as specified and directed.
M & L for rendering 10 mm thick in CM 1:3 on concrete surface of ceiling to be finished even and smooth surfaces without using extra cement complete all as specified and directed.
M & L for Rendering 15mm thick in CM 1:4 on fair faces of brick / stone or concrete surfaces, mixed with water proofing compound and finishing the surfaces even and smooth without using extra cement in patch work at various places upto 4th storey incl necessary formwork complete all as specified & directed.(WPC shall be measured and paid separately)
M & L for Three coat of white wash on newly plastered surfaces of ceilings including necessary preparation of surfaces all as specified and as directed.
M & L for One coat of white wash on old decorated surfaces of ceilings including necessary preparation of surfaces all as specified and as directed.
M & L Preparation of plastered or unplastered old decorated surfaces and applying one coat of white wash on walls complete all as specified and directed.
M & L for Three coat of white wash on newly plastered surfaces of wall including necessary preparation of surfaces all as specified and as directed.
M & L for applying two coats of oil bound distemper on walls over a coat of primer including preparing newly plastered wall surfaces complete all as specified and as directed.
M & L for preparation of Old decorated surfaces of Walls including washing, rubbing down & stopping of distempered surfaces and applying One coat of oil bound distemper Complete all as specified and directed.
M & L for One coat of synthetic enamel paint on old painted concrete surfaces of any description n.exc 10cm width or girth including necessary preparation of surfaces all as specified and as directed.
Supply only integral water proofing compound all as specified and directed.
M & L for 40mm thick Cement concrete type B1 1:2:4 (20mm graded aggregate) in floor, finished even and smooth without using extra cement.all as specified and as directed.
M & L for 75mm thick Cement concrete type C2, 1:3:6 (40mm graded aggregate) in Plinth protection, pavings. Finished even and smooth without using extra cement, incl making joints and filling gap with bitumen mastic all as specified and as directed.
M & L for excavating over areas not exc 1.50m deep and getting out in hard/dense soil all as specified and as directed.
M & L for hardcore of broken stone or boulder gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L for Cement concrete in foundations, filling and mass concrete Type D2 1:4:8 (40mm graded aggregate) all as specified and as directed.
M & L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, industrial type coloured, Pre polished, set, jointed and pointed in neat cement slurry with grey cement and pigments in floors incl. 20mm thick screed bedding layer in cm 1:4. all as specified and as directed.
M & L for Machine pressed precast conctete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed.
M & L for PCC type B1 1:2:4 (20mm graded aggregate) as in copings, bed plates, kerbs incl necessary formwork etc all as specified and directed..
S & F of 110 mm bore dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors as in drain pipes complete all as specified and as directed
M & L for Removing building materials etc. (other than spoil) to a distance of 5km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination all as specified and as directed.
M & L for excavating in trenches, for shafts, wells, cess pits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
M & L for excavating in trenches, for shafts, wells, cess pits, manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m but n exc 3.0 m in depth and getting out complete all as specified and directed.
M & L for excavating in trenches, for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and exc 3.0 m but n exc 4.5 m and getting outcomplete all as specified and directed.
M & L for precast RCC rings M-30 with 4mm dia steel wire, 40 mm mesh reinforcement, size of rings 1.35mtr dia and 0.38mtr height and 56mm thickness, laid in position all as specified and directed.(toward into trenches as recharge pit of borewell all as directed.)
M & L for precast RCC M-30 perforated slab with 4mm dia steel wire, 40 mm mesh reinforcement, size of slab 1.35mtr dia and 56mm thickness, laid in position complete all as specified and directed.
Supply and spread and levelling Boulder pitching, laid dry, hand packed tightly of gauge 300 mm nominal size in rain water recharge pit all as specified and directed.
Supply and spread and levelling aggregate for loose filling, of gauge 80 mm to 150 mm graded nominal size in rain water recharge pit all as specified and directed.
Supply and spread and levelling 20mm graded coarse aggregate in loose filling in rain water recharge pit all as specified and directed.
Supply and spread and levelling Charcoal dust/breeze in rain water recharge pit all as specified and directed.
Supply and laying a nylon mesh over sand, aggregate in rain water recharge pit all as specified and directed.
M & L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
M & L for taking down rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends etc complete all as specified and directed. Note: (i) Necessary Safety Precautions for workers are to be taken by the Contractor.
M & L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and intlet hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 , complete all as specified and directed.
S & F 100mm bore UPVC pipes (Sch - 40) including fittings , jointing, fixed to walls , trench complete all as specified and directed.
Removal of Excavated materials / Building materials out side of MoD land as per guide lines issued by local municipal authorities / state govt authorities all as specified and directed.
K. VENKATESH NAIDU (BID ID -3263608)
PRAGATHI BUILDERS (BID ID -3263122)
M Mohan Babu (BID ID -3263873)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .