Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹44.0 LAccepted-AOC FLAT NO 14 CHHATRAPATI NAGAR NEAR SANTAJI SABHAGRIHA CHANDRAPUR 442401 | CHANDRAPUR | CHANDRAPUR | MAHARASHTRA | 442401 | L-1 | Accepted-AOC Lowest qualified bidder. Hence being awarded | |
| 2 | L-2₹49.7 L+₹5.7 L (13.0%)Rejected-AOC 101 CHAIRANYA ASHISH SHENDE NAGAR TEKA NAKA | NAGPUR | NAGPUR | MAHARASHTRA | 440026 | L-2 | Rejected-AOC Not a qualified L1 bidder | |
| 3 | L-3₹52.9 L+₹8.9 L (20.3%)Rejected-AOC 5TH FLOOR FLAT NO 502 PARVATI APARTMENT TAYWADE NAGAR BESIDE D MART BELTARODI ROAD NAGPUR 440037 | NAGPUR | NAGPUR | MAHARASHTRA | 440037 | L-3 | Rejected-AOC Not a qualified L1 bidder | |
| 4 | L-4₹57.8 L+₹13.8 L (31.4%)Rejected-AOC GORAKSHAN WARD SUCHAK LAYOUT PLOT NO 11 BALLARPUR CHANDRAPUR | BALLARPUR | CHANDRAPUR | MAHARASHTRA | 442701 | L-4 | Rejected-AOC Not a qualified L1 bidder |
Tender Value
₹60.8 L
EMD Value
₹76,000
Closing Date
23 Sept 2023, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri. Nitin Naik
OFFICE OF THE AREA GENERAL MANAGER WCL BALLARPUR AREA P.O. SASTI TA. RAJURA DIST. CHANDRAPUR (MS) PIN 442905
Development works at Area workshop including making of CC hard stand and Office rooms at Sasti OCM under Sasti Sub Area.
2023_WCL_287893_1
ba3650-civ-e66-2023-24/494
Open Tender
Civil Works - Buildings
Item Rate
90 days
WCL Ballarpur Area
As per NIT
6 documents required · 6 mandatory
₹76,000
17 Dec 2023
4 Sept 2023
25 Sept 2023
4 Sept 2023
23 Sept 2023
4 Sept 2023
4 Sept 2023 - 14 Sept 2023
Amount
Earthwork in excavation in drains/ nallah of required size and shape in ordinary soil, soft rock, muddy soil etc.with the help of mechanical means by poclain, JCB etc and disposal of excavated earth within a lead upto 0.00 to 1.00 Km from edges of drains as per the instructions of engg in charge.
Construction of granular sub-base by providing well graded material like natural sand crushed gravel or crushed stone having CBR >30, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator or plant mix method at OMC, and compacting with vibratory rollers of 80 to 100 kN static weight to achieve the desired density, complete as per Clause 401 of Specification. (A) Plant Mix Method For Grading-I Material
Providing laying spreading and compacting stone aggragate of specifc sizes to water bound macadam specifications including spreading in uniform thickness , hand packing, rolling with vibratory roller 8-10 T in stages to proper grade and camber , applying and brooming requisite type of screenings / binding materials to fill up the interstices of coarse aggregate watering and compacting to the required density as per clause 404 of specifications. ( A ) By mechanical means Note : for one 1.00 cum of compacted thickness contractor have to supply following materials 53 mm to 22.4 mm aggregate = 1.21 cum screenings 11.20 mm = 0.24 cum stone dust = 0.08 cum Grading I ( 53 mm to 22.4 mm ) using type B screenings ( 11.2 mm )
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8- 10 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect.
Construction of un-reinforced, dowel jointed, plain cement concrete pavement M-30 grade concrete over a prepared sub base with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but including cost of steel in dowel bar and tie rods etc.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.All kinds of soil.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Brickwork with FLY ASH bricks in foundation and plinth in c.m. 1:6 with approved quality as per the instructions of engg in charge.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Brick work with fly ash. (non modular) brick of classdesignation 7.5 in superstructure above plinth level up to ( In CM 1:6 ) floor five level in :
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece
Centring and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centring and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platforms
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III)derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12 mm cement plaster of mix :1:6 (1 cement : 6 fine sand )
Cement concrete flooring 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. ( 40 mm th with C.C. 1:2:4 with 20 mm stone aggregate )
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work (two or more coats) over and including priming coat with cement primer.
Finishing walls with Acrylic Smooth exterior paint of required shade :New work ( Two or more coat applied @ 1.67 ltr/10sqm. over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm.)
Painting with synthetic enamel paint of approved brand and manufacturer to give an even shade ( Two or more coats on new work )
Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR grade copper wire, flush type switch, earthing and required accessories as per specification No: WGPW/SW
Point wiring for independent plug in PVC trunking (casingcapping) with 1.5 sq.mm (2+1E) FR grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW
Supplying and erecting recess type, 3 pin plug socket 6A with piano switch 6 A combined unit erected on polished double wooden block/ folded or screwed board with top of either wooden or plywood pasted with sunmica and with connecting leads
Supplying and erecting flush type, shockproof plug socket 6 pin 6A and 16A with switch 16A combined unit erected on filled polypropylene board or double wooden block / 3mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick sunmica with S M screws and duly connected.
Supplying and erecting ISI mark modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete.
Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WGMA/BW
Supplying & erecting LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting triple pole metal clad HRC fuse switch 415V, 63A with neutral link with HRC fuses on angle iron /GI frame as per specification no. SW-SWR/TPHRC
Supplying and erecting single pole and neutral distribution board (SPNDB) surface/flush mounted with 2 poles for incoming and 6 poles for outgoing SP MCB’s on iron/ GI frame as per specification no. SW-SWR/MCBDB
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand
White washing with lime to give an even shade Old work (two or more coats)
Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (One or more coat applied @ 0.90 ltr/10 sqm
Total impact of GST for the purpose of CTC
M Kumar
Pravis Enterprises Pvt. Ltd.
RAVINDRA KUMAR
techsummary_298084.pdf
PDF • 0.21 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_298084.pdf
PDF • 1.07 MB
Awarde-66.pdf
PDF • 4.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .