Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹1.3 Cr+₹18.2 L (16.6%)Rejected-Finance | ₹1.3 Cr+₹18.2 L (16.6%) | L2 | Rejected-Finance Being not lowest tenderer |
| 3 | L3₹1.5 Cr+₹37.9 L (34.4%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹1.5 Cr+₹37.9 L (34.4%) | L3 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹81.2 L
EMD Value
₹1.5 L
Closing Date
26 Sept 2022, 6:00 pmClosed
CWE AF TUGHLAKABAD
AF STATION, TUGHLAKABAD PO SANGAM VIHAR NEWDELHI-110080
PROVISION OF ARMOURY AT AF STN PALAM UNDER GE (AF) GURGAON NO.1
2022_MES_549888_1
CWE/TKD/GUR/TOKEN-79/2021-22
Open Tender
Civil Works
Lump-sum
270 days
GE (AF) GURGAON No.1
As per NIT Conditions
8 documents required · 8 mandatory
₹1,000
GE (AF) Gurgaon No.1
₹1.5 L
Yes
23 Nov 2022
5 Sept 2022
28 Sept 2022
5 Sept 2022
26 Sept 2022
12 Sept 2022
Amount
Lumpsum price worked out by the contractor for "Building work" as listed in Sch 'A' Part -I above/below the lumpsum price of Rs 65,00,000.00 as inserted by MES for Sch 'A' Part -I on srl page No 148(R).
Lumpsum price worked out by the contractor for "Site clearance, Earth Work and Excavation" as listed in Sch 'A' Part II above/below the lumpsum price of Rs 134063.03 as inserted by MES for Sch 'A' Part -II on srl page No 149(R).
Lumpsum price worked out by the contractor for "Sewage Disposal" as listed in Sch 'A' Part III above/below the lumpsum price of Rs 46207.86 as inserted by MES for Sch 'A' Part -III on srl page No 150(R).
Lumpsum price worked out by the contractor for "Area Drainage" as listed in Sch 'A' Part IV above/below the lumpsum price of Rs 289251.44 as inserted by MES for Sch 'A' Part -IV on srl page No 151(R).
Lumpsum price worked out by the contractor for "Road/Path/Hard Standing" as listed in Sch 'A' Part V above/below the lumpsum price of Rs 471723.92 as inserted by MES for Sch 'A' Part -V on srl page No 152(R).
Lumpsum price worked out by the contractor for "External Electric Supply " as listed in Sch 'A' Part VI above/below the lumpsum price of Rs 48187.15 as inserted by MES for Sch 'A' Part -VI on srl page No 153(R).
Lumpsum price worked out by the contractor for "External Water Supply" as listed in Sch 'A' Part VII above/below the lumpsum price of Rs 77768.51 as inserted by MES for Sch 'A' Part -VII on srl page No 154(R).
Lumpsum price worked out by the contractor for "Internal Water Supply" as listed in Sch 'A' Part VIII above/below the lumpsum price of Rs 18385.04 as inserted by MES for Sch 'A' Part -VIII on srl page No 155(R).
Lumpsum price worked out by the contractor for "Internal Electric Supply" as listed in Sch 'A' Part IX above/below the lumpsum price of Rs 445181.07 as inserted by MES for Sch 'A' Part -IX on srl page No 160(R).
Lumpsum price worked out by the contractor for "Security wall, fencing & gates" as listed in Sch 'A' Part X above/below the lumpsum price of Rs 1205662.87 as inserted by MES for Sch 'A' Part -X on srl page No 163(R).
Lumpsum price worked out by the contractor for "Demolition and dismantling" as listed in Sch 'A' Part XI above/below the lumpsum price of Rs 9818.80 as inserted by MES for Sch 'A' Part -XI on srl page No 164(R).
Sch 'A' Part-XII (Miscellaneous B&R / E&M Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only.
S&F in repairs SFRC precast cement concrete perforated drain cover with frame of size 900mm x 450mm x 70mm thick surrounded with steel strip 70x2mm reinforced as per manufacturer's design in Manufactured proccess laid over existing drain complete all as specified and directed. Notes: - (i) Make of SFRC Manhole/drain cover and frame : (a) M/s PS Concrete. (b) M/s KK Manhole.Or equivalent as approved by GE. (ii) Contractor shall provide purchage vouchers along with manufacturer test certificate of SFRC cover.
M&L for LLDPE Septic Tank suitable for mim 30 Users (Office purpose) including necessary earthwork in any type of soil with 250mm thick PCC 1:4:8 type B2 using 40mm graded stone aggregate as in foundation including provn of vent etc.as per manufacture instructions complete all as specified and directed. Make:- (a) Sintex (b) Diplast (c) JS Polyplast (d) Rotex (e) Polycon (f) Finolex
M&L for soakage wells of 1.20m dia & 3.00m depth including necessary earthwork in any type of soil, foundation in PCC 150mm thick PCC 1:3:6 type B2 using 40mm graded stone aggregate, walls of honey combed masonry with top ring of M25 concrete (X- size 250 x250mm)(with TMT bars of 3x 12 mm bottom, 2x 12 mm upper & 8mm striuups @ 100 C/C) including intercepting chamber and screen chamber made of brick masonary in cement mortar (1:6),150 mm thick RCC cover slab in M25 with two layer of 12mm @ 100mm C/C TMT bars in both directions, interconnecting pipes of PVC SWR of length one mtr each complete filled with brick bats complete all as specified and directed.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia with existing angle iron 'Y' shaped including securing or tying at crossings with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge
M&L for concealed Sub main wiring alongwith earth wire,concealed in walls/ floors or fixed in wall/ceiling, including the cutting of chases, including provision of PVC conduit (medium grade) of required size and making good to surface to match the original surface with the following sizes of FRLSH PVC insulated unsheathed copper conductor, single core cable complete all as specified and as directed.
4 x 6.0 Sqmm + 2 x 6.0 Sqmm earth wire.
4 x 4.0 Sqmm + 2 x 4 Sqmm earth wire.
2 x 4.0 Sqmm + 1 x 4 Sqmm earth wire.
S&F flame proof heavy duty exhaust fans AC single phase 230/240 V of size 450 mm sweep with louver and 1400 RPM complete and making surface good & finished all as specified and directed . Make Havells-Turbo force single pole/ Bajaj/Halonix
M&L flame proof LED ,CMRI certified IP 65 complete with suitable lamp, 18/20 Watt and all accessories internally pre-wired and including conneting up with three core twisted flexible copper conductor cable of suitable size and making surface good & finished complete all as specified and directed .Make: Crompton CAT No: EXTN1LT 6-18/20or equivalent of Bajaj/Philips/CG)
M&L for energy LED corrossion resistant batten with polycarbonate housing and opal diffuser IP 65 complete with suitable lamp, 40 Watt and all accessories internally pre-wired and including conneting up with three core twisted flexible copper conductor cable of suitable size and making surface good & finished complete all as specified and directed .Make: Halonix CAT No: HLB-04-40-CW or equivalent of Bajaj/Philips/CG)
M&L for LED 5/5.5 W LED Lampcomplete all as specified and directed .Make-Havells-HSN code-8539/Bajaj/CG
S&F telephone socket communication system complete all as specified and directed.
S&F MCB, SP, breaking capacity min 10KA,'C' curve 230V, 6 to 32 Amps complete all as specified and directed.
S&F emergency alarm bell set consisting of transmitting the singnal from one end and receiving on other end of bell complete all as specified and directed .
S&F flame proof ceiling fans, ISI Marked complete with electronic type regulator and accessories 230V, 1200 mm sweep, BEE 5 star rated complete all as specified and directed .
tarun construction co
imran construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .