Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | ₹35.4 L | L1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | L2₹35.9 LRejected-AOC WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | ₹35.9 L | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 3 | L3₹38.4 LRejected-AOC | ₹38.4 L | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 4 | L4₹39.4 LRejected-AOC BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | ₹39.4 L | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 5 | L5₹42.2 LRejected-AOC PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹42.2 L | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/S BUDHRAM BISHNOI L5 | PACHAR BROTHERS L1 | M/S Shree Ram Enterprises L4 | Gill Construction Co L2 | AK CONSTRUCTION L6 | S.K BUILDERS AND ENGINEERS L3 |
|---|---|---|---|---|---|---|---|---|---|
| .10Notes:- (i) 100 percent nonperishable items of the work shall be deposited by the L1 bidder within 30 days after placing of work order. (ii) The critical path network shall be submitted by L1 bidder immediately after the acceptance of tender and approved by GE. (iii) The bidders must ensure to visit the site, check relevant documents and makes of materials required to be incorporated under the subject from concern Engineer-in-Charge. (iv) The unserviceable material obtained under the schedule of credit shall be handed over to the contractor by the Engineer-in-Charge on a proper gate pass. (v) In case of non-availability of any make mentioned under list of Makes, the L1 Bidder shall obtain non-availability / non-manufacturing certificate from the concern OEM / authorised dealers and submitted to Accepting Officer. (vi) L1 Bidder shall produce E-way bill alongwith test certificate from OEM / manufacturer for costly items / major items of amount above Rs 50,000/- along with RAR’s and Final Bill. (vii) L1 Bidder shall be maintained an album containing Photos of all the material brought at site and each stage wise work progress and kept at site. Same shall be deposited in Engineer-in-Charge office after completion of work. (viii) The cost of all the above provisions shall be deemed to be included in the quoted rate of bidder, nothing extra shall be paid to the bidder. | |||||||||
| 1.00 | Dismantling of brick tiles or terracing tiles single layer on roof & disposal of retrieved material upto a distance n.exc 100m where directed, all as specified.
Note: Dismantled Brick tiles shall be deposited at sub division yard withouth extra cost. | 2,840 | Sqm | 79 ₹2.2 L | 50 ₹1.4 L | 30 ₹85,200 | 48 ₹1.4 L | 15 ₹42,600 | 20 ₹56,800 |
| 2.00 | Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, where directed complete all as specified and as directed | 426 | Cum | 129 ₹54,954 | 100 ₹42,600 | 300 ₹1.3 L | 56 ₹23,856 | 150 ₹63,900 | 170 ₹72,420 |
| 3.00 | M&L for Rendering 10 mm thick in cement plaster 1:4 with WPC on roof, fair faces of brick work or concrete surfaces all as specified and directed by Engr -in - charge.
Note : WPC will be measured and paid separately | 2,840 | Sqm | 189 ₹5.4 L | 130 ₹3.7 L | 150 ₹4.3 L | 139 ₹3.9 L | 250 ₹7.1 L | 120 ₹3.4 L |
| 4.00 | M&L PCC 1:2:4 type B0 (using 12.5 mm graded aggregate) in roof as padding complete all as specified and directed by Engr-in-Charge. | 170.4 | Cum | 4,229 ₹7.2 L | 2,500 ₹4.3 L | 3,000 ₹5.1 L | 2,499 ₹4.3 L | 3,500 ₹6.0 L | 4,000 ₹6.8 L |
| 5.00 | M&L for Roof Treatment in as specified below and as directed :
(a) Cleaning, washing of surface and removing any debris, Surface should be free from any loose paint, dust or grease.
(b) Applying one coat of Elastomeric PU Based liquid membrane diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/ sqm.
(c) Laying polyster reinforced fiber net/150 gsm Geotextile mesh, upto 300 mm on walls.
(d) Applying two coats of undiluted PU Based liquid membrane, having Elongation more than 400%, Tensile Strength more than 2 N/mm2 and alkali & fungal resistant maintaining thickness of 1.5mm, with paint brush/ roller upto 300 mm on walls.
(e) The complete treatment to be carried out by authorised applicator of waterproofing manufacturer.
Make : Asian/Fosroc/ Dr Fixit etc
Note : (i) The treatment shall be carried out as per the manufacturers instructions, and as directed by Engineer in Charge and through approved applicator only.
(ii) The plan area of floor shall be considered for payment . | 2,840 | Sqm | 539 ₹15.3 L | 550 ₹15.6 L | 560 ₹15.9 L | 560 ₹15.9 L | 600 ₹17.0 L | 580 ₹16.5 L |
| 6.00 | Supply only Liquid water proofing compound complete all as specified and as directed. | 77 | Ltr | 159 ₹12,243 | 50 ₹3,850 | 98 ₹7,546 | 65 ₹5,005 | 140 ₹10,780 | 100 ₹7,700 |
| 7.00 | M&L Heat Resistant Terrace Tiles (300 mm x 300 mm x 10-12 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with cementious grout of approved make, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and as directed. | 200 | Sqm | 799 ₹1.6 L | 800 ₹1.6 L | 1,100 ₹2.2 L | 754 ₹1.5 L | 900 ₹1.8 L | 800 ₹1.6 L |
| 8.00 | Water proofing treatment to sunken slab and adjoining vertical surfaces as specified under :-
(a) Demolition of cement concrete in sunken portion.
(b) Preparation sunken surfaces by cleaning of and removal of loose concrete
(c) Filling cracks with polymer modified mortar using Dr. Fixit Pidicrete URP or equivalent in Forsoc and other approved make
(d) Applying 2 coats of Dr. Fixit Bath seal WPC in suken areas and laying a protective plaster in 10mm thickness in cement mortar (1:3) admixed with Dr. Fixit Pidicrete LW + @ 220ML per bag of cement
(e) Applying mix of of DR FIXIT PIDICRETE URP in the ratio 1:1:5 on floor and vertical surface of sunken portion as per manufacturers instructions complete
(f) Filling with P:C:C 1:5:10 Type-E2 using 40 mm graded AAC block sludge aggregate complete all as specified and directed by Engineer-in-charge
Note: Only The plan area of floor shall be considered for payment. | 20 | Sqm | 629 ₹12,580 | 500 ₹10,000 | 790 ₹15,800 | 987 ₹19,740 | 500 ₹10,000 | 1,000 ₹20,000 |
| 9.00 | M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) including dismantling existing floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises and complete all as specified and directed by Engineer-in-charge. | 60 | Sqm | 789 ₹47,340 | 700 ₹42,000 | 800 ₹48,000 | 610 ₹36,600 | 700 ₹42,000 | 700 ₹42,000 |
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Dec 2025, 6:00 pmClosed
GE (A) Suratgarh
GE ARMY Suratgarh Mil Stn
REPAIR TO WATER PROOFING TREATMENT AND SUNKEN TREATMENT TO CERTAIN BUILDING INCLUDING REPAIR OF SERVICE WATER TANK IN OTM AND MD ACCN UNDER AGE BR-I AT SURATGARH MIL STN
2025_MES_734125_1
GE (A) SOG Token No 44/25-26
Open Tender
Civil Works
120 days
Suratgarh
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (A) Suratgarh
₹90,000
Yes
29 Jan 2026
7 Oct 2025
3 Dec 2025
7 Oct 2025
1 Dec 2025
17 Nov 2025
Amount
Dismantling of brick tiles or terracing tiles single layer on roof & disposal of retrieved material upto a distance n.exc 100m where directed, all as specified. Note: Dismantled Brick tiles shall be deposited at sub division yard withouth extra cost.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, where directed complete all as specified and as directed
M&L for Rendering 10 mm thick in cement plaster 1:4 with WPC on roof, fair faces of brick work or concrete surfaces all as specified and directed by Engr -in - charge. Note : WPC will be measured and paid separately
M&L PCC 1:2:4 type B0 (using 12.5 mm graded aggregate) in roof as padding complete all as specified and directed by Engr-in-Charge.
M&L for Roof Treatment in as specified below and as directed : (a) Cleaning, washing of surface and removing any debris, Surface should be free from any loose paint, dust or grease. (b) Applying one coat of Elastomeric PU Based liquid membrane diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/ sqm. (c) Laying polyster reinforced fiber net/150 gsm Geotextile mesh, upto 300 mm on walls. (d) Applying two coats of undiluted PU Based liquid membrane, having Elongation more than 400%, Tensile Strength more than 2 N/mm2 and alkali & fungal resistant maintaining thickness of 1.5mm, with paint brush/ roller upto 300 mm on walls. (e) The complete treatment to be carried out by authorised applicator of waterproofing manufacturer. Make : Asian/Fosroc/ Dr Fixit etc Note : (i) The treatment shall be carried out as per the manufacturers instructions, and as directed by Engineer in Charge and through approved applicator only. (ii) The plan area of floor shall be considered for payment .
Supply only Liquid water proofing compound complete all as specified and as directed.
M&L Heat Resistant Terrace Tiles (300 mm x 300 mm x 10-12 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with cementious grout of approved make, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and as directed.
Water proofing treatment to sunken slab and adjoining vertical surfaces as specified under :- (a) Demolition of cement concrete in sunken portion. (b) Preparation sunken surfaces by cleaning of and removal of loose concrete (c) Filling cracks with polymer modified mortar using Dr. Fixit Pidicrete URP or equivalent in Forsoc and other approved make (d) Applying 2 coats of Dr. Fixit Bath seal WPC in suken areas and laying a protective plaster in 10mm thickness in cement mortar (1:3) admixed with Dr. Fixit Pidicrete LW + @ 220ML per bag of cement (e) Applying mix of of DR FIXIT PIDICRETE URP in the ratio 1:1:5 on floor and vertical surface of sunken portion as per manufacturers instructions complete (f) Filling with P:C:C 1:5:10 Type-E2 using 40 mm graded AAC block sludge aggregate complete all as specified and directed by Engineer-in-charge Note: Only The plan area of floor shall be considered for payment.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) including dismantling existing floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises and complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic tiles (coloured) 600mm x 300mm x 7mm thick on vertical surfaces such as dado, skirting etc over & including 10mm thick rendering in cement & sand mortar (1:4)., set in tile adhesive confirming to IS-15477-2019 type 2 and thickness as per manufacturer instruction of approved make including dismantling existing wall tile/ fineshes and rubbish off premises complete all as specified and as directed by Engineer-In-Charge. Including dismantling of existing wall tiling with cement mortar beddind and rubbish off the premises complete.
Supply & fixing in repair vitreous china premium/1st quality wash down water closet wall hung EWC white/ivory/off white (closed pattern incl all necessary accessories like rag bolts/gel gasket etc with & including WC seat cover closed pattern symphonic action type twin flush flushing cistern of 10 litre capacity with lid , incl CP jet spray and Health faucets of made of stainless steel connected for EWC necessary fitting and also incl Angle Stop valves 15 mm bore fancy type, CP, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions and 600 mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete Make :- Parryware Cat Part No "C022N & C0762" or Techno commercial equivalent in make Jaquar/Kohler
Demolition of concrete (reinforced) of any description and in any position not otherwise specifically provided for in any other item here-in all as specified and as directed
M&L for RCC 1:2:4 type B1 (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies and in shelves and all as specified
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
S&F MS TMT Bars of 6mm to 8mm dia,cut to length,bent to shape required including cranking, binding spirally for hooping for columns hooking ends and biniding with and including MS wire (annealed) not less than 0.9 mm dia or securining with clip complete all as specified and as directed
Demolition of Brickwork or stone/boulder masonry,built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed
M&L for fly ash brickwork, old size bricks, straight or curved on plan exc 6m mean radius wall built in cement mortar 1:6 complete all as specified and as directed
All as per item No 17 above but except bricks complete all as specified and as diredcted
Taking down cement plaster or cement lime plaster on stone surface/brick surfaces of walls including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
M&L for Rendering 15 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement all as specified and directed by Engr -in - charge.
M&L Rendering 10 mm thick in cement plaster 1:3 on ceiling finished even and smooth without using extra cement complete all as specified and as directed
M&L for Rendering 15 mm thick in cement plaster 1:4 on other than fair face of brickwork or stone masonry surfaces or on one side of lathing, finished even and smooth without using extra cementcomplete all as specified and directed by Engr -in - charge.
M&L preparation of newly plastered surfaces of wall applying two coat of acrylic distemper white/tinted over and including 2mm thick layer of wall care putty finished surface by hand roller complete all as specified and directed by Engr -in - charge.
M&L for preperation of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of acrylic distemper white/tinted complete all as specified
M&L preparation of newly plastered or unplastered surfaces of wall applying three coat of White Wash complete all as specified and directed by Engr -in - charge.
M&L preparation of newly plastered or unplastered ceiling surfaces and applying three coat of white wash complete all as specified and directed by Engr -in - charge.
M&L preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed by Engr -in - charge.
Taking up or down 15mm dia GI/PVC Tubing and connection including, cleaning for refixing or removal to store complete all as specified.
Taking up or down 20mm dia GI/PVC Tubing and connection including, cleaning for refixing or removal to store complete all as specified.
Supplying and laying of 20mm OD bore / 1/2" CPVC pipes SDR 13.5 & Plain / brass CPVC SDR 11 fittings including all fittings and fixed complete to walls and ceilings or laid in floors, trenches including plug at opening or points for fitting and fixtures and powder coated clamps for fixing in walls complete all as specified and directed by Engineer-in-charge.
Supplying and laying of 25mm outer dia CPVC pipes SDR 13.5 & Plain / brass CPVC SDR 11 fittings including all fittings and fixed complete to walls and ceilings or laid in floors, trenches including plug at opening or points for fitting and fixtures and powder coated clamps for fixing in walls complete all as specified.
S&F of 20 mm inner dia (OD 22.2 mm) CPVC Brass Male/ Female Brass Threaded Adaptor fittings complete all as specified
Supply and fixing in repair CPVC globe or gate valve (ISI marked), heavy duty, plain both ends suitable for 20mm bore iron pipes and including CPVC solvent cement for jointing complete all as specified and as directed by Engineer-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc complete all as specifed and directed.
Supply & fixing 110mm bore uPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls/tranches with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant including bends, socket , Y junction, Tee , cowl etc complete all as specified and as directed by Engineer-in- charge complete including low carbon hot roll gauge corrected oil pickled & drawn pipe supporting clamping system 32x3mm with rib and notch are hot dip galvanised and Zn, Al flake coating with necessary clamps to fix and hold pipe complete all as specified and directed. (Note: Detail of Pipe supporting system is all as per Drg NO -BTD-916). Note:-UPVC PIPE AND FITTING / FIXTURE-
Supply & fixing 75mm bore uPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls/tranches with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant complete including bends, socket , Y junction, Tee , cowl etc all as specified and as directed by Engineer-in- charge complete including low carbon hot roll gauge corrected oil pickled & drawn pipe supporting clamping system 32x3mm with rib and notch are hot dip galvanised and Zn, Al flake coating with necessary clamps to fix and hold pipe complete all as specified and directed. (Note: Detail of Pipe supporting system is all as per Drg NO -BTD-916)
S&F uPVC (SWR) 75 mm floor trap, plain with grating including jointing with solvent cement complete all as specified complete all as specified.
Gill Construction Co (BID ID -3481374)
S.K BUILDERS AND ENGINEERS (BID ID -3486331)
M/S Shree Ram Enterprises (BID ID -3481248)
M/S BUDHRAM BISHNOI (BID ID -3480250)
AK CONSTRUCTION (BID ID -3481674)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
tender44.pdf
Tender Documents • 1.27 MB
BOQ_822046.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid