Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC WZ 199 LAJWANTI GARDEN GALI NO 4 NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹24.8 L+₹1.3 L (5.31%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance HIGHER RATE | |
| 3 | L3₹24.8 L+₹1.3 L (5.42%)Rejected-Finance RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance HIGHER RATE | |
| 4 | L4₹24.8 L+₹1.3 L (5.42%)Rejected-Finance 112 AMBALA ROAD NARAINGARH AMBALA 134203 | NARAINGARH | AMBALA | HARYANA | 134203 | L4 | Rejected-Finance HIGHER RATE | |
| 5 | L5₹25.4 L+₹1.8 L (7.74%)Rejected-Finance | L5 | Rejected-Finance HIGHER RATE |
Tender Value
Refer Docs
EMD Value
₹54,402
Closing Date
4 Jul 2024, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
ADDN/ ALTN AND SPECIAL REPAIRS TO FLOORING OF BASKET BALL/ TENNIS COURTYARD NEAR BLDG NO B-12 AND PROVISION OF TILING, BOOSTER PUMP AND PIPE LINE IN WATER COOLER AND DRINKING WATER POINTS AT NCS CHANAKYAPURI UNDER GE NEW DELHI
2024_MES_659849_1
NIT No GE/ND-24/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NEW DELHI
₹54,402
Yes
11 Sept 2024
14 Jun 2024
6 Jul 2024
14 Jun 2024
4 Jul 2024
28 Jun 2024
Amount
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed.
M&L for grinding of existing kota stone flooring surfaces by picking, sweeping clean and washing down with water to remove dust, complete all as specified and directed.
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and incl 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M & L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed over and incl 10mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M& L for (i) Surface preparation and Priming Coat:- Existing surface shall be clean, free from all dirt and foreign debris, and shall be dry. All surfaces must be structurally sound, any unsound material(s) removed by chipping or scarifying. Oil and other contaminants should be removed by solvents or acid etching, and all resultant residues thoroughly removed. When acid etching, surface shall be thoroughly rinsed and neutralized with a 1% ammonia solution. One part of Epoxy Concrete Primer to be diluted with two parts water and applied over the entire area with roller/squeegee at a coverage rate not less than 0.12 Kg/m2. The surface shall be fully coated with primer without allowing the material to accumulate in low spots. Continue.........
(ii) Patch Work/ Resurfacer:- The entire area should be flooded with water and checked for depressions of 1/16" or greater. Depressions shall be leveled properly using acrylic resufacer by mixing 1 part of Acrylic Resurfacer to 1 part #60 - #100 mesh silica sand. Only small amount of water to be added if necessary, to achieve workability. Once patching is complete, two applications of Acrylic Resurfacer shall be applied to the surface. Water ,silica sand, and Acrylic Resurfacer must then be mixed thoroughly (50 Kg. of Acrylic Resurfacer 40 Kg. Cement 50 Kg. of Silica sand #80 Clean drinking water @ 1.10 kg/Sqm) until the material is consistent. The amount and size of the sand may be varied to achieve different textures and filling properties. Larger sand will have greater filling properties. The mixed product shall be applied to the surface using a soft, rubber squeegee. The finished surface shall have a uniform appearance and be free of ridges and tool marks. 2nd application should be 90°angle to the 1st application. The coverage rate for acrylic resurfacer shall be 0.29 - 0.40 kg/m2 per application of undiluted material. SBR layer 8 mm thick styrene butadiene rubber cushion to be laid with SBR granules of appropriate size mixed with acrylic binder.
(iii) CUSHION COAT:- Cushion Coat is a resilient, multi-layered application designed to provide the player with added comfort and a more enjoyable playing experience by reducing shock to the lower extremities. Apply 4 coats of Cushion Powder mixed with acrylic binder. Sand shall not be added to cushion coat. The consumption rate for the powder cushion coat is 0.29 kg/m2. cushion coats shall be applied using a soft rubber, or notched squeegee. Each application should be applied perpendicular (90 degrees) to the previous coat. A drying time of at least of 5 hours between each Cushion coat shall be allowed. Each coat must be fully cured before proceeding to the next coat or water may become trapped between the cushion layers and cause peeling and blistering.
(iv) COLOR Coat:- Color Coat is a wear resistant, 100% acrylic emulsion consisting of brilliant pigments and quality polymers that are blended into a highly concentrated form and it should not contain any asbestos, lead, or mercury. Two coats of textured base coats (25 Kg. of acrylic color emulsion, 7 - 12 Kg. of Silica sand #80 and clean drinking water 0.615 kg/Sqm) to be applied in perpendicular directions followed by a non-textured top coat pulled parallel to the net. Texture coat coverage is approximately 0.26 kg/m2 per application of undiluted material (v) Game line marking:- game line marking to be done as per standard with floor based line paints. Note:- application shall strictly be carried out by the authorised vender/ manufacturers with all specifications and as approved by the GE. The manufacturer shall give a guarantee for the peformance & durability for 5-years.
M&L for complete removal of existing treatment from old surfaces of wall scrapping by machanical means and applying two coats of Exterior Emulsion paint (APEX ULTIMA) using roller brush over one coat of primer and over incl one coat of Birla putty complete all as specified and directed.
Taking down cement plaster on brick wall surfaces including racking out joints hacking for key scrubbing down with water etc and removing the rubbish out of MoD Land complete all as specified and directed.
Dismantlling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for joint free glazed ceramic coloured tiles in vertical surface 350 x 250 x 7 mm or 450 x 350 x 7 mm thick with matching highlighter over and including 10 mm thick rendering in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or colour cement to match coloured tiles (Design/colour of tiles will be approved by GE) complete all as specified and directed.
S&F in repair 15mm bore dia Stainless Steel finish angular stop cock with wall flange quarter turn full Antique including cover plate complete in all respect complete all as specified and directed.
S & F in repair 15mm bore dia CP finish Bib Cock quarter turn including cover plate complete in all respect complete all as specified and directed.
Supply, installation, testing and commissioning of electric driven booster pump of capacity 1.0 HP with water tank of 24 ltrs capacity ,single phase, voltage range 180-240V including wiring and other accessories complete all as specified and directed.
Supply, laying, jointing & testing 3- layer PP-R Polypropylene random copolymer concealed pipes of size 25 mm dia, SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed.
Supply and fixing PP-R gate valve 25 mm bore with fittings complete all as specified and directed.
SANJEEV ENTERPRISES
HANUMAN BUILDERS
J S CONSTRUCTION CO
R.P Builders
B S R Enterprises
Tanveer Associates
friends associeates
Shivam Firetech Engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .