Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | ₹1.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.3 Cr+₹3.7 L (2.84%)Rejected-AOC | ₹1.3 Cr+₹3.7 L (2.84%) | L2 | Rejected-AOC NOT L1 |
| 3 | L3₹1.3 Cr+₹4.6 L (3.52%)Rejected-AOC C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | ₹1.3 Cr+₹4.6 L (3.52%) | L3 | Rejected-AOC NOT L1 |
| 4 | L4₹1.4 Cr+₹7.1 L (5.48%)Rejected-AOC FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹1.4 Cr+₹7.1 L (5.48%) | L4 | Rejected-AOC NOT L1 |
| 5 | L5₹1.4 Cr+₹12.0 L (9.28%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.4 Cr+₹12.0 L (9.28%) | L5 | Rejected-AOC NOT L1 |
| Sl No | Description | Qty | Unit | M/S P S BABU L3 | Shree Ayyappa Engineering L5 | pk janardhanan L1 | M/s. P S REDDY L4 | K M SUBHANAIAH L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Chipping loose concrete and Exposing existing RCC columns,beams,slabs,lintels,pardis etc.including plaster beyond main reinforcement carefully by means of chisel and hammer or mechanically including necessary double scaffolding ,erecting horizontal platforms at working levels to collect the debris, propping with top and bottom runners as directed stacking the debris in the compound as directed and caring away the same outside the premises etc. complete. | 154.74 | Sqm | 125 ₹19,342.5 | 55 ₹8,510.7 Lowest | 100 ₹15,474 | 200 ₹30,948 | 100 ₹15,474 |
| 2.00 | RELIEVING STRUCTURAL MEMBERS Relieving structural members such as column, beam and slabs of their superposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing , jacking up arrangement all complete to the satisfaction of Engineer in charge(Removing and redoing of brickwork, if required ,shall be paid separately. | 630 | Nos | 500 ₹3,15,000 | 410 ₹2,58,300 | 125 ₹78,750 Lowest | 500 ₹3,15,000 | 126 ₹79,380 |
| 3.00 | Chipping of existing loose, damaged concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on External and internal facades etc beyond main r/f.(if required in the opinion of the Consultant),carefully with chisel and hammer providing and applying ' Rusticide SS' Rust passivater or equivalent as specified in the Brand Names to existing r/f bars including wire brushing of reinforcement, cleaning washing of concrete etc complete as directed.Providing and applying two coats of rust preventer slurry made out of " Polyalk Fixoprime"or equivalent as specified in the Brand Names and cement in proportion 1:1:5 to existing r/f bars as directed complete.Providing and applying bonding coat of slurry made out of "Polyalk EP" or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and e/f substrates complete as directed Providing and applying "Polyalk EP" or equivalent as specified in the Brand Names,Polymer modified cement mortar in Required proportion(1:5:15) to RCC members including hand packing,curing and making the surface rough for plastering. | 650 | Sqm | 1,000 ₹6,50,000 | 155 ₹1,00,750 Lowest | 800 ₹5,20,000 | 650 ₹4,22,500 | 765 ₹4,97,250 |
| 4.00 | FILLING AND REINSTATING OF SEPARATION CRACKS Opening the Separation cracks at the Junction of RCC and Masonry where ever directed and instructed into "V" Grooves 2" to 3" from the either side of the cracks by carefully marking the areas to be opened up using a cutting machine and skillfully Chiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete Substrata and masonry wall with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed. | 280 | RM | 150 ₹42,000 | 65 ₹18,200 | 80 ₹22,400 | 200 ₹56,000 | 45 ₹12,600 Lowest |
| 5.00 | Moistening the cracks ,providing and applying primary/bonding coat of slurry made of "Polyalk EP" and cement(or equivalent as specified in the list of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the cracks /Grooves by Providing and applying "Polyalk EP" Polymer modified cement mortar (or equivalent as specified in the list of Brand names) in Proportion of 1:5:15 (Polyalk EP: Cement: Graded sand/quart/sand ) on the prepared surfaces and finishing it in the level with the existing plaster including hand packing curing and making the surface similar to the external plastering using wooden floats/punch etc. complete as per specified and directed. | 280 | RM | 150 ₹42,000 | 210 ₹58,800 | 80 ₹22,400 Lowest | 500 ₹1,40,000 | 90 ₹25,200 |
| 6.00 | Drilling holes of required size up to 16mm Diameter and up to 50mm depth in concrete and cleaning the same as directed. | 280 | Nos | 100 ₹28,000 | 65 ₹18,200 | 40 ₹11,200 Lowest | 100 ₹28,000 | 45 ₹12,600 |
| 7.00 | Providing and fixing 12mm diameter aluminium/PVC injection nipples and securing the same as directed & Providing and injecting cementations grout using CEBEX-112 additive of 'Fosroc' at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete. | 280 | Nos | 180 ₹50,400 | 450 ₹1,26,000 | 100 ₹28,000 | 500 ₹1,40,000 | 99 ₹27,720 Lowest |
| 8.00 | Providing &fixing epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns before jacketing Micro concreting as per Consultants instructions and directions. | 300 | Nos | 250 ₹75,000 | 125 ₹37,500 Lowest | 150 ₹45,000 | 300 ₹90,000 | 135 ₹40,500 |
| 9.00 | Providing,cutting,bending and fixing Additional Reinforcement in position steel reinforcement of specified required sizes and shapes in the form or main rebars, stirrups & rings,distrubtion rebars tec.and tying them to shear connectors using GI Binding wire. The additional rebars should be coated with TWO coats including Anti Corrosive protective coating &dry sand to be sprinkles on second coat including tying with Annealed Binding wires, providing cover blocks of appropriate sizes etc complete as specified and instructed by the Consultants. | 700 | Kg | 110 ₹77,000 | 125 ₹87,500 | 70 ₹49,000 Lowest | 250 ₹1,75,000 | 90 ₹63,000 |
| 10.00 | Providing and laying super fluid Micro concrete -Roffe crete repairs (or equivalent as specified in the list of Brand names) in beam bottoms, columns, slab etc including mixing with 5mm to 10mm size aggregates waterproof ply wood/steel plate shuttering,pouring,temping,Consolidating,curing etc complete as per Manufacture's specification and Consultants instructions. The item shall be paid on actual consumption of Micro concrete. | 16,500 | Kg | 30 ₹4,95,000 Lowest | 48 ₹7,92,000 | 40 ₹6,60,000 | 100 ₹16,50,000 | 45 ₹7,42,500 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
26 Jul 2025, 6:00 pmClosed
COL SAIKAT DE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO IL-ALW WORKSHOP (BLDG NO P-128) AT INS HANSA UNDER GE(NW) VASCO
2025_MES_706853_2
85953
Open Tender
Civil Works
Item Rate
Vasco
As per Tender
9 documents required · 9 mandatory
₹1,000
GE (NW) Vasco
₹2.2 L
Yes
21 Aug 2025
4 Jul 2025
28 Jul 2025
4 Jul 2025
26 Jul 2025
12 Jul 2025
Amount
Chipping loose concrete and Exposing existing RCC columns,beams,slabs,lintels,pardis etc.including plaster beyond main reinforcement carefully by means of chisel and hammer or mechanically including necessary double scaffolding ,erecting horizontal platforms at working levels to collect the debris, propping with top and bottom runners as directed stacking the debris in the compound as directed and caring away the same outside the premises etc. complete.
RELIEVING STRUCTURAL MEMBERS Relieving structural members such as column, beam and slabs of their superposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing , jacking up arrangement all complete to the satisfaction of Engineer in charge(Removing and redoing of brickwork, if required ,shall be paid separately.
Chipping of existing loose, damaged concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on External and internal facades etc beyond main r/f.(if required in the opinion of the Consultant),carefully with chisel and hammer providing and applying ' Rusticide SS' Rust passivater or equivalent as specified in the Brand Names to existing r/f bars including wire brushing of reinforcement, cleaning washing of concrete etc complete as directed.Providing and applying two coats of rust preventer slurry made out of " Polyalk Fixoprime"or equivalent as specified in the Brand Names and cement in proportion 1:1:5 to existing r/f bars as directed complete.Providing and applying bonding coat of slurry made out of "Polyalk EP" or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and e/f substrates complete as directed Providing and applying "Polyalk EP" or equivalent as specified in the Brand Names,Polymer modified cement mortar in Required proportion(1:5:15) to RCC members including hand packing,curing and making the surface rough for plastering.
FILLING AND REINSTATING OF SEPARATION CRACKS Opening the Separation cracks at the Junction of RCC and Masonry where ever directed and instructed into "V" Grooves 2" to 3" from the either side of the cracks by carefully marking the areas to be opened up using a cutting machine and skillfully Chiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete Substrata and masonry wall with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed.
Moistening the cracks ,providing and applying primary/bonding coat of slurry made of "Polyalk EP" and cement(or equivalent as specified in the list of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the cracks /Grooves by Providing and applying "Polyalk EP" Polymer modified cement mortar (or equivalent as specified in the list of Brand names) in Proportion of 1:5:15 (Polyalk EP: Cement: Graded sand/quart/sand ) on the prepared surfaces and finishing it in the level with the existing plaster including hand packing curing and making the surface similar to the external plastering using wooden floats/punch etc. complete as per specified and directed.
Drilling holes of required size up to 16mm Diameter and up to 50mm depth in concrete and cleaning the same as directed.
Providing and fixing 12mm diameter aluminium/PVC injection nipples and securing the same as directed & Providing and injecting cementations grout using CEBEX-112 additive of 'Fosroc' at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete.
Providing &fixing epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns before jacketing Micro concreting as per Consultants instructions and directions.
Providing,cutting,bending and fixing Additional Reinforcement in position steel reinforcement of specified required sizes and shapes in the form or main rebars, stirrups & rings,distrubtion rebars tec.and tying them to shear connectors using GI Binding wire. The additional rebars should be coated with TWO coats including Anti Corrosive protective coating &dry sand to be sprinkles on second coat including tying with Annealed Binding wires, providing cover blocks of appropriate sizes etc complete as specified and instructed by the Consultants.
Providing and laying super fluid Micro concrete -Roffe crete repairs (or equivalent as specified in the list of Brand names) in beam bottoms, columns, slab etc including mixing with 5mm to 10mm size aggregates waterproof ply wood/steel plate shuttering,pouring,temping,Consolidating,curing etc complete as per Manufacture's specification and Consultants instructions. The item shall be paid on actual consumption of Micro concrete.
Providing and laying in slabs,beams,pardise,RCC wall etc position of RCC M-25 design mix grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying and the cost of centering,shuttering form work,finishing and excluding reinforcement,including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete,improve workability without impairing strength and durability as per direction of Engineer-in charge. The Mix design as per particular specifications shall be got approved by Engineer -in charge before execution of the item. The rate shall include cost of all specified materials and operations at all levels and heights, including the cost of centering ,shuttering and form work excluding reinforcement which shall be paid under relevant item (Note:- Cement content considered in this item @ 300 kg/cum as per IS 456 table showing minimum cement content. No extra will be paid nor any amount will recovered on account of variation of cement in mix design as per specifications for controlled
Glass fiber Wrapping system : Provision &laying applying Glass Fiber sheet wrap at structural members including .surface preparation: Grinding/Moulding concrete substrate ,cleaning it with wire brush, removing oil, laitance if present, rounding sharp edges to min 25mm radius etc,complete.Profiling :Applying PRIMER on prepared substrate, filling holes and uneven surface with PUTTY etc, complete. Wrapping the Glass fiber wrap to voids etc. Repeat the same procedure for multiple layer with interval of 8 hours. Sand pasting: Applying saturant,rectify air voids if any ,paste the river sand on it to make surface rough to take any further finishes.(Mode of Measurement:Per Sqm of fiber consume and not application and not application of surface area.)
Note of item No. 1 to 12 :- (a)Post completion NDT report based on the item catered in Sl No 1 to 12 of BOQ or otherwise mentioned , a certificate has to be furnished along with detailed post NDT report certifying structural strengthening carried out and repair work carried out as desired and technically acceptable report has to be vetted and certified by IIT/NIT/Govt Engg College as approved by the CEA or other institution and detailed structural repair of specific strength to be provided as required by GE (b) After complete execution of these items post NDT of all the members catered has to be done by the contractor. (c) While execution it is to be kept in mind that desired strength of the structural members should be maintained. (d) Complete report should be submitted for all the structural members catered. (e)The items of structural repair shall be executed by authorized applicator (f) The rate quoted for item No. 1 to 12 shall deemed to be inclusive of the above provisions
Removing and demolishing the existing waterproofing up to slab level of any thicknes stacking the excavated debris on the ground floor , in the compound of the building carting away the same outside the MES premises
Providing and applying fiber reinforcement Elastomeric liquid applied waterproofing membrane ,formulated with PU hybrid polymers and reinforcing acrylic fibers and can bear upto 10 bar hydrostatic pressure by using damp proof course having Sun Reflective Index (SRI) of 106 .59 on top concrete roof in three coats @10.8 liter/10 sqm. One coat of self –priming of elastomeric water proofing liquid (dilution with water in ratio 3:1) and second coat of undiluted elastomeric waterproofing liquid followed by 3rd and final coat of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 600 micron ) with waterproofing warranty 10 years . Note:- Prior to all this activity surface preparation to be done by pressure washer to remove Dust, Algae ,fungus , oil grease ,etc and crack filling by textured crack filler up to 10mm wherever required and bigger crack should be filled with polymer modified cement . On tile mosaic surface use smartcare terrace tile primer for better adhesion . The item rate is inclusive of all material with wastage , labor, tools tackles, Consumable . scaffolding etc.
Providing 10mm thick plaster in CM (1:4) mixed with 3% integral water proofing compound over roof top surface including filling all cracks by forming groove of 5mm x 5mm finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid separately
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings
Supply and fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
Supply and fix PVC Rain Water Pipe 150 mm dia including all fittings, head , shoes, branches all as specified fixed in wall including joint with PVC adhesive
Supply and fix for PVC plain bends 150 mm bore
Supply and fix 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed in floors/ walls.
Supply and fix 110 mm bore PVC (SWR) bends of any radius.
Supply and fix 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
Supply and fix 75 mm bore PVC (SWR) bends of any radius
Dismantling mild steel work of any description not otherwise provided for
Supply and fix Mild steel roof trusses (framed), Trussesd, purlins, crane gantries, rails and framings and heavy bracket framing (Beam, tee, angle, channel or flat sections) confirming to Fe 410-W including cleats, distance pieces etc
Material and labour for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) any thickness, including cover fillets.
Providing & Fixing of Mineral Fiber Acoustical Suspended Ceiling System with ANF (Board) edge tiles with Armstrong 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 90%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 34%.The tile shall be laid on Prelude38 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of approved make. The Tile & Grid system used together should carry a 10 year warranty all as directed by Engineer in Charge.
Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames)
Taking down chowkats or frames exc 1.5 sqm but n. exc 4 sqm each (w/o taking off shutters from the frame ) complete all as specified and directed.
Material and labour for complete removal of existing treatment and Preparation of Old wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer.
Material and labour for 2nd class hard wood 35mm thick Plain framed, paneled shutter(two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both face. The size of rail and style as per IS:1003(Part-I), kiln seasoned and chemically pressed treated and all as Specified and as directed by Engineer- in -Charge.
Material and labour for preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of primer complete all as specified.
Supply & fixed in repair brass Hat pegs, solid body 125mm to 175 mm as specification.
Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of ater etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in- Charge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made
Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ - .2mm ). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system.. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) (A) Area not exceeding 2.00 sqm each
Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made
Supply and fix Powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including stranded aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and directed
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam colour PVC sheet on back face, including 20 mm thick PVC lining around all 4 edges of shutter, supplying & fixing in frame at site as per specification & drawing all as specified and directed.
Supply and fix Factory made 100% solid wood plastic(WPC) Decorative Door Frame, single rebate of size 75mm x 50mm made from wood plastic composite(single extruded process) material with density 780 Kg/Cum complete all as specified and directed.
Supply and fix Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: with bevel gear box and crank handle 1.25mm thick.
Supply and fix Safety lever locks mild steel with 4 levers for rolling shutters all as specified and directed.
Supply and fix Ball bearing for rolling shutters all as specified and directed.
Material and labour for preparation of new steel surface and applying one coat of zinc chrome primer and two coats of Epoxy anticorrosive paint after surface preparation as per manufacturer's specification and as directed by the Engr-in-Charge , Cost inclusive of material , primer , labour , painting brush, tools and tackles etc (Excluding cost of staging)
Material and labour for 12 mm thick Prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination & other side balancing white lamination, fixed with screws to timber/aluminium frame work in cupboard shutters, partitions, shelves, pelmet boxes or narrow widths and similar work.
Supply and fix 200 mm long Aluminium, anodised, barrel tower bolts of extruded section
Supply and fix in repairs 200 mm long Aluminium, anodised, barrel tower bolts of extruded section
Supply and fix butt hinges medium weight stainless steel 100 mm size
Supply and fix 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised.
Aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed in repairs
Supply and fix in repairs of floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of over plate 140 mm
Supply and fix aluminium (die cast) body door closer hydraulically regulated designation No 3, universal type suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed in repairs
Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for.
Material and labour for 25 mm thick Cement concrete type B1, 1:2:4 (using 20 mm graded granite stone aggregate) mixed with polyester fiber @ 0.25% of weight of cement in roof/floor for maintaining proper slope to avoid water logging all as specified and directed.
Material and labour for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in subbase ,plinth protections, finished even and smooth w/o using extra cement
Dismantling of stone slabs and tiles of any description or thickness in floors/dado etc laid bedded and pointed in any mortar
Material and labour for 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) us ing marble dust with admix true of pigment to match with shade of granite complete all as specified and directed.
Providing edge moulding to 18-20mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete.
Material and labour for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over including 20 mm thick screed bed in CM 1:4 unpolished complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises
Material and labour for Coloured Non skid ceramic tiles light/dark shade 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exe 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
All as per item No. 62 but as in skirting/dado but over 10 mm thick rendering over CM 1:4
Material and labour for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed
Material and labour for coloured Glazed ceramic tiles in vertical surfaces 450 x 300 x7 mm/ 450 x 350 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & incl.10 mm thick rendering in CM 1:4.complete all as specified and as directed.
Material and labour for Anti static tiles 10 to 12 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed. Note : Rate for All other material required for flooring including in above items.
Dismantling water tanks and removing to store exc 500 but n. exc 1000 Ltrs
Supply and fix four layer white colour (with Highly UV resistant layer) rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position inc 20mm bore PVC float valve all as specified and directed in SSR Pt I
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .
All as per item No. 69 above but 25 mm dia .
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm.
All as per item No. 71 above but 25 mm dia
Supply and fix in repairs fancy type chromium plated 15 mm bore stop valve/angle cock cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
Supply and fix in repair Wash basins 550x400mm vitreous china (flat back type) any size including cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe(32 mm) but including waste fittings
Supply and fix fancy type pillar taps, 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed as in repair complete all as specified.
Supply and fix PVC valve less, symphonic action type flushing cistern, low level , white, with inlet ball valve, float and handle including brackets 10 litres capacity .
Supply and fix in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete including seat and cover, flush pipe including all joints complete
Supply and fix in repair chromium plated two way bib cock with wall flange in complete all as specified and directed.
Supply and fix for hand shower (Health faucet) dia 8mm 1 mtr long flexible tube and wall hook
Supply and fix in repairs Soap dish, of material brass with glossy finish,
Supply and fix in repairs Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges .
Supply and fix in repairs Hasp and staple 125 long, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws
Supply and fix in repairs 40mm dia, cupboard knobs fixed with nut, screw and washer of brass, bright finished
Supply and fix in repair Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed
Supply and fix in repairs Vitreous China half stall urinals, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, magnum urinal spreader, pointing around urinal back in cement; flush pipe, grating and Union for discharge pipe.
Supply and fix in repairs chromium plated 15 mm bore Push taps cast copper alloy high pressure screwed for iron/CPVC pipe for urinal complete all as specified and directed.
Supply and fix in repairs PVC Connections 15mm size with PTMT nuts of length 600 mm complete all as specified and directed.
Supply and fix in PVC (SWR) floor trap 75 mm, plain with CP grating including joining with solvent cement complete
Supply and fix in repairs bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms) 32mm bore
Supply and fix in repair 20 mm bore, chromium plated bib taps cast copper alloy with crutch or butterfly handle screwed down for iron/PVC pipe complete all as specified & directed.
Supply and fix in repair Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union along with arm 225mm and flange.
Supply and fix grating round 125 mm size of PTMT (min weight 40 grams)
Supply and fix in repair Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long.
Demolition of stone /boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles.
Material and labour for pre - cast cement concrete masonry with Grade C-5.0, (20mm graded stone aggregate) with solid blocks wall built in cement mortar 1:6
Taking down cement plastering at any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debris and depositing where directed.
Material and labour for rendering 5 mm thick in CM 1:3 in ceiling finished even and smooth (without using extra cement)
Material and labour for Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 including dubbing & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid separately.
Supply only water proofing compound
Material and labour for rendering 10 mm thick in CM 1:6 on concrete solid block wall internal surface finished even and smooth without using extra cement.
Material and labour for Preparing new plastered ceiling surfaces and applying two coat of oil bound distemper over alkaliresistant priming paint with 3mm putty on plastered surfaces, preparatory to distempering as specified and directed.
Material and labour for Preparing new plastered wall surfaces and applying two coat of oil bound distemper over alkaliresistant priming paint with 3mm putty, on plastered surfaces, preparatory to distempering as specified and directed.
Material and labour for complete removal of existing treatment and Preparing old plastered ceiling surfaces and applying two coat of oil bound distemper over alkaliresistant priming paint with 3mm putty, on plastered surfaces, preparatory to distempering as specified and directed.
Material and labour for complete removal of existing treatment and Preparing old plastered wall surfaces and applying two coat of oil bound distemper over alkaliresistant priming paint with 3mm putty, on plastered surfaces, preparatory to distempering on wall as specified and directed..
Dismantling of existing steel rolling shutters including top covers for repairs & refixing in the same opening after repairs including greasing the spring, guide channel shafts, bearing, bolts, washers, including repairing defective laths spring bearing , hood cover, guide channel suspension shafts etc complete as directed by Engr-in-Charge for rolling shutter of clear area up to 7 Sqm each Note:- Necessary spores will be measured & paid separately.
Material and labour for preparation of new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm all as specified and as directed.
Demolition reinforced cement Concrete of any description and in any position not otherwise and removing drebries from site to a distance not exc 50 mtr away and depositing where directed
S& F in repair Ball brass valve, high pressure, with polythene float horizontal plunger type, IS-1703-2000 marked screwed to iron pipe or brass ferrule of size 25 mm bore complete all as specified and as directed.
Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power) complete including conduits/casing capping with fittings such as switches, ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of wall Supply and floors etc to match with the original existing finish complete all as specified and as directed
Material and labour for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC casing capping of as required size (not less than 20 mm in width) ISI marked medium grade with all accessories of same grade fixed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No 112 here in before, but for one fan/exhaust fan point controlled y one 5 Amp switch one way complete all as specified and as directed
All as per item No 112 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed
All as per item No 112 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the same board complete all as specified and as directed
Material and labour for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC casing capping grade of as required size (not less than 20 mm in width) ISI marked medium duty, with all accessories of same grade, fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
Material and labour for point FRLS/LS wiring with 1.5 Sq mm nominal area PVC insulated and unsheathed cable single core multistranded, copper conductor in and including non metallicPVC conduit in concealed/surface on wall as required at site of size not less than 25 mm dia, ISI marked medium grade with all fittings and fixing materials and PVC insulated multistranded copper earth continuity conductor of size 1.5 Sq mm connecting etc for one light/Exhaust fan point all as specified and directed by Engr-in-charge.
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing capping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
Material and labour for sub main wiring with four runs of single core 10 Sqmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non metallicPVC conduit in concealed/surface on wall as required at site of size not less than 25 mm dia, ISI marked medium grade with all accessories such as Tees, elbows, junction boxes etc, as required fixed concealed in wall along with Two run of 10 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Four runs of cable, two run of earth continuity conductor and one run of PVC conduitshall be measured as one unit)
All as per item No 119 here in before, but two run of single core 6 sqmm and one run of 6 sqmm cables as earth continuity conductor all as directed.
All as per item No 119 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor all as directed.
Supply and fix in repairs modular Switch single pole one way 6 A, 240 V complete all as specified and as directed
Supply and fix in repairs modular Switch single pole one way 16 A, 240 V complete all as specified and as directed
Supply and fix in repairs Modular Socket outlet 2 in 1, 6 Amp , 240 volts, complete all as specified and as directed
Supply and fix in repairs Modular Socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 volts complete all as specified and as directed
Supply and fix in repairs Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed
Supply and fix in repairs Modular Fan step regulator, 120W - 2 module all as directed.
Taking down unserviceable any type of Main Switch, DB's including MCBs including wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed.
Supply and fix in repairs 20/25 Amps motor starter switch with overload protection , ideal & safe for air conditioners , cooler , water pumps , refrigerators mixer , and all type of appliances Computers complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 20/25 Amp Power unit combo MCB Protected socket with top , ideal & safe for air conditioners , cooler , water pumps , refrigerators mixer , and all type of appliances Computers complete all as specified and directed by Engr-in-Charge.
Supply and fix sheet metal enclosure Vertical TPN distribution board, 415 volts 4 way double door with IP-43 protection, suitable for mounting of MCCB Capacity upto 125 Amps with 400 amps copper bus bar, complete all connections with proper thimbling and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall to match with existing surface . (Note:- MCCB, MCBs will be measured and paid separately.
Supply and fix Sheet metal enclosure Vertical TPN distribution board, 415 volts 8 way double door with IP-43 protection, suitable for mounting of MCCB Capacity upto 160 Amps with 400 amps copper bus bar, complete all connections with proper thimbling and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall to match with existing surface . (Note:- MCCB, MCBs will be measured and paid separately.)
Supply and fix in repairs MCCB of 160A breaking capacity 25 KA , 4 pole thermal magnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's complete all as specified and as directed
Supply and fix in repairs MCCB of 125 A breaking capacity 25 KA , 4 pole thermal magnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's complete all as specified and as directed
Supply and fix in repairs MCB DB TPN 6 way DB 415 V with 400 A rated bus bar double door type complete all as specified and as directed.
Supply and fix in repairs MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door type complete all as specified and as directed.
Supply and fix in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
Supply and fix in repairs MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
Supply and fix in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
Material and labour for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust, common salt, vegetable soil and bentonite powder 5 to 10 Kg, etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed .
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised earth wire all as complete specified and as directed
Taking down ceiling fan1200/1400 mm sweep of any make from its existing position after disconnecting of electric connection for carrying out repairs including servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent including renewal of minor spare parts such as split pins, cater pins, coupling bolt, capacitor holder, terminal adaptor, screws, nuts and washers etc and replacement of spare parts/accessories such as ball bearings, gun metal bushes, capacitor, canopy top and bottom, shackle clip assembly, rewinding of fan motor, painting and including hanging/ fixing back in existing location and making cable connections and testing for its satisfactory performance complete all as specified and directed. (Note: - Spate parts will be measured and paid separately
Supply only fan capacitor 2.5 / 3.15 mfd, 240 volts, 50Hz complete all as specified and directed.
Supply and fix in repairs only ball bearing suitable for ceiling fan/exhaust fan/air circulator/pedestal fan any type. all as directed.
Supply only shackle clip assembly with rubber bush reel and nuts, bolts and washers suitable for ceiling fan of any sweep complete all as specified and directed.
Supply only PVC canopy top and bottom with tighten screw suitable for ceiling fan of any sweep complete all as specified and directed by Engr-in-charge.
Supply only split pin as per sample suitable for ceiling fan all as directed by Engr-in-charge
Supply only MS nut bolt with split pin as per sample and as directed by Engr-in-charge
Supply and fix down rod made of MS pipe medium grade 15mm dia of 300/450/600 mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to of down rod with two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply and fix copper conductor cable 3 core; 0.75 sqmm, PVC insulated, sheathed, flexible, multistranded,1100 volts grade for making connection to ceiling fan from ceiling rose complete all as specified and directed .
Material and labour for painting to ceiling fan of any sweep complete body, blades and down rod with two coat of synthetic enamel paint similar to match with existing colour after preparation of surfaces by using electric spray machine including marking of MES Number with black paint complete all as specified and directed .
Material and labour for rewinding of ceiling fan motor of size 1200 mm sweep to 1400 mm sweep of any make/model/type with new supper enameled copper winding wire of similar gauge and number of turns as existing, including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from ceiling fan motor complete all as specified and directed.
Material and labour for rewinding of exhaust fan motor of 300/380 mm sweep with new super enameled copper winding wire of similar gauge and number of turns as existing, including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from exhaust fan motor complete all as specified and directed.
Material and labour for painting to exhaust fan of any sweep complete body, blade assembly, frame of 300 mm sweep to 450 mm sweep with two coat of synthetic enamel paint similar to match with existing colour after preparation of surfaces by using electric spray machine including marking of MES Number with black paint complete all as specified and directed .
Supply and fix in repairs Energy efficient surface Mounted LED Luminaries 18 watts 4' long, with acrylic cover complete with all accessories including necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr all as directed.( Note : Quoted rate shall included taking down of old any type of fitting ) Make : BAJAJ Cat part No : BCLSB 18 W WH or techno commercially equivalent in PHILIPS, CROMPTON GREAVES, BAJAJ, WIPRO, JAQUAR, HAVELLS
Supply and fix in repairs Energy efficient surface Mounted mirror LED light Luminaries 10 watts 2' long, with acrylic cover complete with all accessories including necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr all as directed.(Note : Quoted rate shall included taking down of old any type of fitting ) Make : BAJAJ Cat part No : BCLSB 10 W WH or techno commercially equivalent in PHILIPS, CROMPTON GREAVES, BAJAJ, WIPRO, JAQUAR, HAVELLS
Material and labour for in repairs for Ultra modern recess/surface mounting luminaries 2' x 2' size 36 Watts LED natural white colour suitable for Armstrong/grid/POP ceiling complete with separate electronic driver & high brightness SMD LEDs. complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make : BAJAJ Cat part No : BPRF 36W WH SL LED or techno commercially equivalent in PHILIPS, CROMPTON GREAVES, WIPRO, JAQUAR, HAVELLS
Supply and fix in repairs Building Security LED fitting 90 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on Building by providing MS angle iron bracket of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed. Make : Havells Cat part No ENDURAOMNIPLUSSL90W LED757SASYTOPC or techno commercially equivalent in PHILIPS, CROMPTON GREAVES, BAJAJ, WIPRO, JAQUAR
Supply and fix in repairs integral LED aviation light comprising of aluminium housing with polycarbonate enclosure with necessary fixing arrangement such as GI pipe, fixing clamp, brackets,etc.complete all as specified. Make: Bajaj Cat No BGAV 302 LED or or techno commercially equivalent in PHILIPS, CROMPTON GREAVES, WIPRO, JAQUAR, HAVELLS
Supply and fix in repairs Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fix flameproof exhaust fan of size 457 mm , single phase consisting of not less than 0.33 HP motor complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs Flame proof Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as directed by Engr-in-charge.
Dismantling Window type Air Conditioner complete unit of capacity 1.5 TR and re-installation the complete with necessary provn of wall opening, cement work in the new position complete all as specified.
Supply and install voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA.
Dismantling the existing GI Central AC plant grill, duct with insulation by dismantling MS duct flange, unscrewing of nut, bolt and washer, removing the insulation material and keep the same in the safe custody and refix the same into the existing position by re-assembling including replacement of new duct insulations, new fixing arrangement and re-fixing the grills complete after repair work complete all as specified and as directed. Note:-The job inclusive of taking down/Refixing of Existing duct with all new accessories like GI duct, MS flange, anchoring materials, nut, bolt, washers, applying two coat of anti corrosive paint over the duct external surfaces, etc. of approx 50% on total length, 100% replacement of new duct insulation complete.Approx length of duct 50-100 mtr
Taking down old rusted cable tray for SFCs very carefully including all connected fitting and fixing of new cable tray of suitable size as per existing and Supply and fix of new perforated cable tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width sizes including accessories like coupler plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, complete all as specified and as directed.
Material and labour for chemical earthing pit with copper earth plate of size 900mm x 600mm x 5mm thick buried directly in ground vertically to a depth not less than 4m below normal ground level, connected to & including 50 x 6 mm copper strip by means of nuts, bolts check nuts and washers made of copper and connected to test point including brazing and excavation and earth work in any type of soil, with charcoal 250 Kg, crystal salt 200 Kg, magnesium sulphate of 50 Kg, Bentonite powder 50 Kg and vegetable soil all around the plate 35 cm depth bottom to top of the plate full width of pin including PCC 1:3:6 type C1 in chamber of internal size 300mm x 300mm x 300mm with wall thick ness of 120mm and 700mm x 700mm x 150mm bed concrete, precast PCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 kg/Sqm) with cast iron frame, funnel, with wire mesh, 25mm bore medium grade GI pipe, lugs, 80mm bore medium grade GI protection pipe, test point etc complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earth strip and protection pipe up to 7.5m is included in the rate quoted)
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and leveling of bottom surface to required level for laying UG cable / errection of poles all as specified.
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/disintegrated rock getting out and leveling of bottom surface to required level all as specified.
Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish all as all as directed by Engr-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified.
Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point. all as specified.
Supply and lay Double walled corrugated pipe (DWC ), heavy duty 110/90 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
Taking down old unserviceable LT UG cable from any description (trenches, walls, ceilings., etc) from various locations, Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 120 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified.
All as per item No. 174 here in before but of size 3.5 core 70 sqmm
All as per item No. 174 here in before but of size 4 core 50 sqmm
All as per item No. 174 here in before but of size 4 core 35 sqmm Note for item No 174 to 177 1. Excavation, Concrete cable protection cover, pipe, PCC work for road crossing / hard standing and Sand for cushioning will be measured and paid separately. 2. Cost of glands, aluminium cable lugs (eye lid/barrel / bottle neck type/ring type or any shape), new nut, bolt and washers of required size / description are deemed to include in this rate. 3. Clamping of cable in wall properly are included in the quoted rate.
Material and labour for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials.
g) Angle iron base frame as required size as per above panel, total leg height 900 mm and grouting in side PCC 150 mm legs and made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No. h) Material and labour for necessary grouting as required PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job Outgoing :- a) MCCB 4 Pole,160 Amp 415V - 02 No b) MCCB 4 Pole,125 Amp 415V - 01 No c) MCCB 4 Pole,100 Amp 415V - 01No
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage up to 3.3 kv for electrical purpose as per IS15652-2006,(superseding IS 5424) suitable for electrical shock safety of sizes 2mx1m
Supply and fix in repair Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15 cm size all as directed.
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI strip size 32 x 6 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling in vegetable soil including adequate quantity of charcoal dust and common salt bentonite powder 5-10 kg etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
Material and labour for Earth Continuity conductor as aluminium strip of size 25 x 3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground of any type of wall surfaces with necessary fixing arrangement by providing porcelain base at 60cm inter bal and using cadmium plated fixing screw and insulator par running meter all as required at site complete after dismantling of old unserviceable galvanized iron strip all as specified and directed. (Note:- 1. Strip will be installed on saddles in such a way that in no case the GI strip comes in direct contract with wall/roof of the building. 2. GI strip will be fixed epoxy base insulators of suitable size and rates are deemed to be included in quoted prices).
Material and labour for Air termination, single pointed, Aluminium rod 12 mm dia and 300 mm long , mounted on aluminium base plate rigid fixed on top roof height complete and insulated from base and taking out old unserviceable complete all as specified and directed by Engr-in-charge.
Material and labour for test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hex. Head screw complete all as specified and directed by Engr-in-charge.
Galvanised base plate of size 100mmx100mmx12mm rigid fixed on top roof height for mounting of 12mm aluminium rod and connected item complete and insulated from base complete all as specified and directed by Engr-in-charge.
Material and labour for 40mm dia GI tubing (light grade) with complete all fittings etc fixed on walls upto test point all as specified and directed
K M SUBHANAIAH (BID ID -3364209)
M/S P S BABU (BID ID -3362688)
M/s. P S REDDY (BID ID -3372651)
Shree Ayyappa Engineering (BID ID -3364290)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .