Loading…
Loading…
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
20 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
Above/Below/Par
ELECT.GEN.
12 conditions · 1 needing a document upload
The contractor shall submit self attested copy of valid Electrical Contractor License as per Clause No. 45 IE Rule 1956 along with the offer. The offer will be summarily rejected in absence of valid Electrical Contractor License.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
12 conditions · 6 needing a document upload
The registration of contractors working under Railway departments with ESIC is mandatory (if applicable as per current Law / Act)
In case a tenderer is participating as Sole Proprietor in a tender, it is mandatory for him to submit an undertaking on suitable stamp paper to this effect clearly mentioning PAN number also along with tender document at the time of submission of tender.
The tenderer may submit scanned copy of partnership deed if applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor shall ensure all precautions during digging work close to Rly signaling, telecom electrical cables etc. Penalties to be imposed for damages to any cable as per Railway board letter no. 2021/Tele/5(2)/3- Part(1)/(3425647) dtd 12.06.2023
Electrification work in connection with BSL (CZ) - Repairs to the Engineering Drawing Office, General Section, and Budget Section in the DRM Office, Bhusawal.
BSL-L-W-T-32-2026
BSL-L-W-T-32-2026
Open
Works - General
6 Months
Jalgaon, Maharashtra
₹0
₹87,000
20 May 2026
24 Apr 2026
6 May 2026
79 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 43,48,659 | ||
| — | Breakup for | details. | — | ||
| Wiring of the concealed Light / fan Point with all accessories and running earthing copper conductor as per standard practise. The switches shall be of modular type.(along with the all accessories and including cutting the wall / ceiling / chipping and re plastering, distempered / painted as the case may be, the same as good condition as directed by Engineer in charge at site.) | — | — | — | 2,75,200 | |
| — | Breakup for | details. | — | ||
| SETC of Wiring of the concealed 6 A / 3 Pin Universal plug point as per latest IS on switch board with all accessories and running earthing copper conductor as per standard practise. The Switches shall be of ModularType. | — | — | — | 43,520 | |
| — | Breakup for | details. | — | ||
| SETC of 4 nos. 5 A plug socket with switches (3 Plug & 3 Switch) on separate board along with point wiring or rewiring with 2 x 2.5 sq.mm. FRLS copper wire etc. | — | — | — | 88,900 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of Recessed Mount 1'x1' LED Light Panel light Fitting 15 Watts. | — | — | — | 68,670 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of Recessed Mount 2'x2' LED Light Panel light Fitting 29 Watts. | — | — | — | 5,10,480 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing and commissioning of BLDC Super efficient electrical Ceiling Fan 1400 mm sweep (56') 260-280 RPM, Services value 7.7 input voltage 140-285 V. Power consumption 26 W to 30 W. Air delivery 270 CMM or more, 3 blades with double ball bearing with regulator of electronic step type and down rod 300-600 mm as per requirement, canopies, shackle. | — | — | — | 2,56,360 | |
| — | Breakup for | details. | — | ||
| Supplying and erecting regular/ standard model Ceiling fan of 900 /1050 mm. sweep complete. | — | — | — | 45,700 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of Pedestal fan ocillating type 90 degree, sweep 400 mm RPM-1300 suitable to work on on 230V AC 50HZ supply input watt-55 with adjustable stand, guard and blade complete. | — | — | — | 34,395 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of Heavy Duty single phase Exhaust Fan of 380 mm size sweep,1440 RPM duly wired with 3 core flexible copper wire and fixing arrangement, hardware etc. complete. | — | — | — | 39,990 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of Concealed wiring for call bell with copper PVC insulated FRLS 1.1 KV point wiring of 2 x1.5 sq.mm. wire on PVC conduit of suitable size with all accessories and running earthing.The plug point to be provided on separate switch board and switch with supply and fixing of bell and switcHThe switch should be bell push type 5 A capacity. .(along with the all accessories and including cutting the wall / ceiling / chipping and re plastering, distempered / painted as the case may be, the same as good condition as directed by Engineer in charge at site) | — | — | — | 3,880 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing and commissioning of 15 A 3 pin universal plug socket with switch alongwith independent point wiring in PVC casing capping with 2x4 sq. mm. FRLS multistranded PVC copper wire alongwith all accessories, running earth etc. Modular type | — | — | — | 6,624 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of Industrial type metallic plug sockets 30A with MCB DP 30 A with 2x4 sqmm PVC insulated and sheathed copper conductor complete etc. | — | — | — | 8,680 | |
| — | Breakup for | details. | — | ||
| SETC of Lightning Circuit board, double door powder coated with locking arrangement consisting of 1 Nos X 40A 2P RCBO as I/C and 06 Nos x 32 A 2P RCBO, 2 Nos X 16 A 2P RCBO as O/G with complete accessories. | — | — | — | 1,99,235 | |
| — | Breakup for | details. | — | ||
| SETC of Lightning Circuit board, double door powder coated with locking arrangement consisting of 1 Nos X 63A RCBO 4P as I/C and 18 Nos x 32 A 2P RCBO, 4 Nos X 16 A 2P RCBO as O/G with complete accessories. | — | — | — | 1,93,448 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of Submain from switch board to single phase DP switch / DP one circuit meter comprising of 2x4 sq.mm. PVC insulated FRLS 1.1KV multistranded wire & one running earth of 2.5 sq.mm. copper conducting PVC insulation green colour of 1.1 KV grade on rigid PVC casing caping with all accessories. | — | — | — | 1,98,000 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of Submain with 2x6 sqmm FRLS copper wire inside PVC Casing caping with running earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of 6 sqmm with one wire of 2.5 sqmm for earth conn). | — | — | — | 1,58,200 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing and commissioning of Submain with 2x10 sqmm FRLS copper wire inside PVC Casing caping with running earth etc complete.(1 m length of submain consists one cktmtr including all accessories & 2 wire of 10 sqmm with one wire of 2.5 sqmm for earth conn.) and finishing of the surface after rewiring. | — | — | — | 1,04,800 | |
| — | Breakup for | details. | — | ||
| SETC of Outdoor type LT Panel as per IEC 61439 with double door powder coated with locking aragnements consisting 1 Nos X 400 A 4P MCCB for I/c and 4 Nos x 125 A 4P MCCB, 6 Nos x 63 A 4P MCCB for O/G with ELR & CBCT for each MCCB, Power qaulity analyzer, communicable Multifunction meter, indication lamp, copper busbar, & other assocciate aceesories. All MCCB are Microprocessor based (completely wired with suitable communication cable to fetch data from each compartment functional Unit (ACB/MCCB/SFU etc) / Multifunction Meter) and other accessories. | — | — | — | 6,37,956 | |
| — | Breakup for | details. | — | ||
| Supply, laying, running & fixing of 4 Core 35 Sqmm AL. Conductor, XLPE insulated, PVC sheathed, armoured cables as per relevant IS with cable marker in trench or saddled on the wall/truss or with GI saddles etc. | — | — | — | 1,54,000 | |
| — | Breakup for | details. | — | ||
| Supply of 4 core 185 Sqmm armoured XLPE Cable. | — | — | — | 5,12,000 | |
| — | Breakup for | details. | — | ||
| Trenching & refilling of LT/HT/ Various sizes of PVC / XLPE cables- Along the Road (Size - 900mm x 300mm) | — | — | — | 1,61,700 | |
| — | Breakup for | details. | — | ||
| Digging of cable trench 300/450 mm x 1000 mm in RCC/PCC/hard soil & refilling as per specification and requirement at the site. | — | — | — | 1,20,300 | |
| — | Breakup for | details. | — | ||
| Transportation, Laying, Installation, terminating, testing and commissioning of LT/HT cable of sizes 10 sqmm to 400 sqmm in existing trench, pipe or on structure. | — | — | — | 31,000 | |
| — | Breakup for | details. | — | ||
| Erection,testing and commissioning of cables other than trench i.e.Wall/Truss including clamp, GI wire and hardware | — | — | — | 14,400 | |
| — | Breakup for | details. | — | ||
| Supply & laying of GI pipe Class B, ISI marked under road /Clamping with erecting pole or wall as per technical specification & drawing for passing cable. | — | — | — | 4,040 | |
| — | Breakup for | details. | — | ||
| Supply,installation, testing & commissioning of HDPE Pipe 110 mm Nominal Dia as per IS-4984-1995. | — | — | — | 12,500 | |
| — | Breakup for | details. | — | ||
| Supply and laying of RCC half round pipe 150 mm ID & 1 mtr length. | — | — | — | 97,200 | |
| — | Breakup for | details. | — | ||
| Supply and laying of RCC Hume Pipe of size 6"(150mm) dia 2 mtr. Length. | — | — | — | 755 | |
| — | Breakup for | details. | — | ||
| Supply, erection of RCC Type cable route marker with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. | — | — | — | 9,980 | |
| — | Breakup for | details. | — | ||
| Supply & Erection of RCC Warning Cover and refilling the cable trench in an approved manner. | — | — | — | 9,460 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of maintenance free earth as per RDSO specification no. RDSO/PE/SPEC/ PS/0109-008(REV '0') with improved earthing enhancing compound and exothermic welding | — | — | — | 1,52,190 | |
| — | Breakup for | details. | — | ||
| Supply, fabrication, laying welding and connection of GI Flat of size 25x3 mm from earth pit with GI nut Bolt suitable size. | — | — | — | 17,100 | |
| — | Breakup for | details. | — | ||
| Supply, fabrication, fixing and erection of MS Work of miscellaneous size and for cable tray etc. including painting complete. | — | — | — | 16,050 | |
| — | Breakup for | details. | — | ||
| Dismantling of existing wiring with associated accessories like cables, brackets , poles etc. | — | — | — | 11,956 | |
| — | Breakup for | details. | — | ||
| Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc.complete. | — | — | — | 2,250 | |
| — | Breakup for | details. | — | ||
| SETC Indicator Board with Red & Green LED complete with Driver and Wiring etc. | — | — | — | 29,760 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing and commissioning of Point wiring for light, fan, exhaust fan in PVC casing capping with 2x2.5 sq. mm. FRLS multistranded PVC copper wire alongwith all accessories, running earth and and finishing of the surface after rewiring etc. | — | — | — | 28,350 | |
| — | Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of 6 A 3 Pin universal plug socket complete with switch, wiring and earth connection, to be provided in Existing light/fan board. | — | — | — | 1,380 | |
| — | Breakup for | details. | — | ||
| SETC of SFU 125A TPN with HRC Fuse. | — | — | — | 88,250 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument322026.pdf
ATTACHMENT
GCCApril2022dt.27.04.2022.pdf GCC Apr 2022
ATTACHMENT
ACS1to6ofGCC.pdf
ATTACHMENT
ACS7to10ofGCC.pdf
ATTACHMENT
ACS11toGCC.pdf
ATTACHMENT
GCCApril2022dt.27.04.2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .