| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹14.4 L+₹17,573 (1.23%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹15.7 L+₹1.5 L (10.6%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹16.2 L+₹2.0 L (14.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹16.9 L+₹2.7 L (18.9%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
9 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda, Bathinda Military Station
AUGMENTATION, OF ELECTRIC SUPPLY NETWORK AT SECTOR-VI SOUTH CAMP AT BATHINDA MIL STATION
2021_MES_437877_1
CWE BTD 8190/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Bathinda Mil Station
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (U) BATHINDA
₹29,000
Yes
3 Jul 2021
22 Apr 2021
11 Jun 2021
22 Apr 2021
9 Jun 2021
13 May 2021
23 Apr 2021 - 30 Apr 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr wide, and not exceeding 1.5 metre in depth and getting out in soft / loose soil for foundation, laying of cables or pipes (where provided) fixing of poles and stays and struts and including trimming of sides and forming bottom surfaces to required level complete all as directed.
Returning filling in, including spreading , levelling, watering and well ramming in layers each not exceeding 25cm thick in soil complete .
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete.
M & L for local sand cushioning, with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR-Part-1 before laying of cable and 150mm thick after laying of cable and punned down to 180mm after laying complete. Note:- Punned thickness shall be considered for payment purpose.
Supply and laying reinforced precast concrete cable cover, Class EHV Type 1 with peak, size 450mm x 230 mm x 50mm.
Supply, laying, jointing and testing of XLPE HT Cable 11 KV, 'Earthed System', heavy duty with XLPE insulated stranded aluminium conductor cable of cross sectional area 3 core 185 Sqmm served with an inner sheathed of PVC tape armored with Galvanized steel strip or wire and over all PVC sheathed conforming to IS-7098 (Part-II) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete including taking out old cable from trenches. Note :- (Excavation & earth work, jointing material , cable cover & sand cushioning shall be measured and paid for separately under relevant item of this BOQ.)
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination cold shrink type joint complete with jointing material and accessories suitable for 3 core, 185 Sqmm XLPE armoured aluminium conductor cable.
S&F cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core 185 Sqmm XLPE armoured aluminium conductor cable.
Supply and laying GI tubing, light grade, 100mm bore complete with all fittings for cable and earth continuity strip protection laid in trenches/fixed to poles/along wall/under road/across the drain complete.
M & L for making the hole under road and hard standing not less than 1 metre depth and suitable for laying and inserting pipe upto 100 mm dia any length by mechanical drill system or Auger system and making the surface good as per existing surface complete. Note: GI tubing shall be measured and paid separately.
Supply and erect in true vertical position of pre stressed concrete pole 11 M long of size 152 mm x 152 mm at top and 152 x 260 at bottom class 9, complying with requirements of IS-1678-1998 embeded in PCC foundation including painting of poles with two coats of synthetic enamel paint with black and white strips (03 No black and 2 No white each strip 30 cm high) upto 1.5 M height including applying two coats of cement base paint on PCC coping complete.
M&L for cable route / joint indicator fabricated from 40 x 40 x 6 mm angle iron 450 mm long, revetted or welded with 100 mm dia CI or MS round disc duly engraved 'HT CABLE JOINT' in letters including grouted into the ground with PCC (1:4:8), type D-2 with 40 mm graded stone aggregate minimum size of PCC 20 x 20 x 30 cm deep from ground level complete all as specified and directed by Engr-in-Charge..
S&F switch air break , gang operated, triple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 400 Amps, outdoor type (conforming to IS specifications) HT 11 KV, triple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse assembly, fuse carrier fitting, 12 insulator type mounted on MS channel operating rod with and including 7 lever pad lock (Godrej/ Harrison/ Link) arrangement complete.
M&L for lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp, suitable for working pressure for 11000 volts complete.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling & mass concrete for PCC poles complete.
M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in foundation of electrical poles including necessary formwork complete.
M & L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in coping for poles including necessary form work complete.
M&L for platform of size 2 mtr x 2 mtr x 1.2 mtr high (outer size) built with 150 mm thick PCC 1:4:8 D2 foundation extending 150 mm on both sides of wall 345 mm thick brick work built in cm 1:4 , 450 mm below GL & 1000 mm above GL and rendering 15mm thick in cm 1:4 and floor 50 mm thick PCC 1:2:4 type B-1 laid in bays over 100 mm thick hard core over approved earth filling, including chain link fencing 1.8 m high and span 5 x 5 M made out of 4mm dia GI wire 150 x 100 mm mesh, MS work of angle iron 50 x50 x 6 mm as fencing post embeded in PCC 1:2:4 type B-1 using 20 mm grade stone aggregates including excavation in post holes returning filling etc at 2 mtr interval each side as approved and 1 No steel gate (3.5 m clear) span with locking arrangement made out of 15 mm dia MS rod and 50x50x6 mm angle iron frame, painting with 2 coat of aluminium paint over a coat of red oxide primer and 3 coat of white washing on cement work including ISMB 100 channel 2 Nos for fixing transformer complete all as specified and directed.
Transporting, fixing & installation only transformer of any capacity upto 160 KVA and connecting with HT/LT side of existing system and testing complete all as specified and directed by Engr-in-Charge. Note:- (i) The T&P vehicles and minor parts/ nut bolts etc will be arranged by the contractor and the cost deemed to be included in the quoted rates. (ii) Transformer will be issued under Sch 'B' free for fixing and installation only. Shifting, transporting from yard & fixing charges deemed to be included in this item '
M&L for earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6.0mm buried directly in ground, vertically to depth not less than 2.25mtr below normal ground level with top edge of the earth plate at depth not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI strip of size 32x6mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe medium grade 20mm bore for watering, 40mm bore GI pipe medium grade for protection of GI strip upto test point including providing funnel and wire mesh GI frame and 10cm thick suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40mm graded stone aggregates complete including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exceeding 50 mtr, all as specified and shown in Electrical plate No. 3 of SSR Part-1 (PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit) including testing on completion complete. Note :- The rate quoted by the contractor shall be deemed to be included of earth strip 32 x 6 mm and pit protection pipe 40 mm dia light grade up to 7.5 mtr distance. Earth strip beyond 7.5 mtr will be measured and paid separately under relevant items.
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required with 32mm x 6mm galvanised iron strip.
Sandeep Enterprises
M/s Kataria Construction Company
Rasvinderpalandco
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .