Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC 01 18 19 ANANDVAN ROW HOUSE LAM ROAD NASHIK ROAD NASH IK ROAD SAUBHAGYA NAGAR NASHIK MAHARASHTRA 422101 | NASHIK | MAHARASHTRA | 422101 | L1 | Accepted-AOC SINCE L1 | |
| 2 | L2₹31.6 L+₹2.1 L (7.02%)Rejected-Finance | L2 | Rejected-Finance SINCENOT L1 | |
| 3 | L3₹32.3 L+₹2.8 L (9.34%)Rejected-Finance ALPHA HOUSE PLOT NO 29 AGP P10 ASHWIN SECTOR NEW CIDCO NASIK 422 009 | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance SINCENOT L1 | |
| 4 | L4₹32.7 L+₹3.1 L (10.6%)Rejected-Finance 10 SANJAY HSG SOCIETY RACCA COLONY SHARANPUR ROAD NASHIK 422 002 | NASHIK | MAHARASHTRA | 422002 | L4 | Rejected-Finance SINCENOT L1 | |
| 5 | L5₹33.9 L+₹4.3 L (14.7%)Rejected-Finance | L5 | Rejected-Finance SINCENOT L1 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
21 Oct 2021, 6:00 pmClosed
GE DEOLALI
GE DEOLALI, 422401
SPL REPAIR TO ROOF TREATMENT OF BLDG NO P 632 OR LIVING AT MUNRO LINE OF 6 FD REGT UNDER AGE B/R CENTRAL DEOLALI, PROVN OF INSTALLATION OF SOLAR PLANT AT SARVATRA OFFRS MESS AND CERTAIN MINOR WORKS UNDER THE AOR OF GE DEOLALI
2021_MES_477789_1
8021/E8
Open Tender
Civil Works
Item Rate
180 days
GE DEOLALI
CLASS D cat a i
9 documents required · 9 mandatory
₹500
Yes
GE DEOLALI
₹99,000
Yes
22 Dec 2021
25 Sept 2021
23 Oct 2021
25 Sept 2021
21 Oct 2021
9 Oct 2021
Amount
Taking up or down 25mm bore of pipe GI steel tubing and connections, including cleaning for refixing or removal outside MD land etc complete all as specified and directed.
Taking up or down 20mm bore of pipe GI steel tubing and connections, including cleaning for refixing or removal outside MD land etc complete all as specified and directed.
Refixing 25 mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
Refixing 20 mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
S&F for 25 mm bore of tube medium grade Galvanised steel water tubing with all fittings and fixed complete to walls, cutings or laid in floor including taking steel tubing with connections etc complete all as specified and directed.
S&F for 20 mm bore of tube medium grade Galvanised steel water tubing with all fittings and fixed complete to walls, cutings or laid in floor including taking steel tubing with connections etc complete all as specified and directed.
Dismantling of water tanks of capacity exc 250 ltrs but n. exc 500 ltrs including disconnecting all connections etc. complete
Dismantling of water tanks of capacity exc 500 ltrs but n. exc 1000 ltrs including disconnecting all connections etc. complete
Disconnecting existing tanks of capacity exc 250 ltrs but n. exc 500 ltrs , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc..
Disconnecting existing tanks of capacity exc 500 ltrs but n. exc 1000 ltrs , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
S&F 500 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 25mm bore dia Ball brass valves, high pressure, with polyethylene float and flynut complete,screwed for iron pipe or brass ferrule and fixed etc complete all as directed.
S&F 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 25mm bore dia Ball brass valves, high pressure, with polyethylene float and flynut complete,screwed for iron pipe or brass ferrule and fixed etc complete all as directed.
S&F in repairs 20mm bore gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe etc complete all as specified and directed.
S&F in repairs 25 mm bore gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Taking down carefully existing unserviceable bitumen felt(any number of layers) including plaster of any thickness,wire brushing and cleaning of the surface of roof terraces including flashing and junctions of parapets kerb wall,PCC fillets,benching etc and removing of the rubbish to a distance not exceeding 500 M from the building and depositing where complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for 15 mm thick rendering in CM 1:4 on brick/concrete external surfaces of walls finish etc complete all as specified and directed.
M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces
M & L for water proofing treatment to RCC roof slab as specified below and as directed by Engineer-in-Charge :- (a) 10 mm th cement plaster in CM 1:4 with integral WPC to be laid over the RCC roof slab when the concrete is green.(b) Applying a uniform coat of bitumen primer @ 0.70 kg/sqm over cement plaster. (c) 3 mm th plain texture and weighing not less than 4.00 kg/sqm Atactic Polypropylene Polymer (APP) modified bitumen based prefabricated five layer water proofing membrane reinforced with non woven polyster matt black finished over compatible primer at 0.4 Ltr / sqm of density at 25 degree centigrade 0.87 - 0.89 kg/ltr and viscosity 70-160 cps or cold sticker and torch application of membrane with overlap while torching shall be 150 mm on length side and 100 mm on width side. after necessary preparation of surface complete as per manufacturers instructions. (d) Apply two coats of bitumastic - aluminium paint over the membrane.
M&L for cement concrete type Bo 1:2:4 (using 12.5mm graded stone aggregate) 25 mm thick as in roof to achieve slope on existing roof surface all as directed.
Taking down of PVC pipes (any size or pattern including all fittings, heads, shoes, bends , swan-neck etc (measured overall as fixed along the centre line over fittings and accessories)
S&F 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and directed
S&F 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and directed
S&F PVC (SWR) bend any radius 110mm complete all as specified and directed
S&F PVC (SWR) bend any radius 75mm complete all as specified and directed
S&F PVC (SWR) branch piece 110 mm bore, single (single Y) equal or unequal complete all as specified and directed
S&F PVC (SWR) branch piece 75 mm bore, single (single Y) equal or unequal complete all as specified and directed
Demolition of brick work / stone boulders masonry built in cement mortar incl all Quoins, archeas, pillars etc bu exc cluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for Brickwork with fly ash Old size bricks, straight or curved on plan exc 6m mean radius, built in in CM 1:6 etc complete all as specified and directed.
Supply & installation ,testing and commissioning of 10 KW solar off grid solar system including solar panels Habells Solar module (monoperc panels) PV module 10 KW , solar off grid inverter 10 KW, Inverter battery 200 AH- 10 Nos- C10(5 year warranty), DC cable-150 mtrs, solar grade DC and AC Cable, earthing and suitable iron mounting and necessary civil works as required onsite structure all as specified and directed.
Supply & fix onload change over switch 100 amps, 3 phase and neutral 4 pole, front operated with sheet steel enclosure all as specified and directed.
M & L in repairs sub main wiring for 3 phase system with 4 single core, 10 Sqmm, PVC insulated unsheathed,multi stranded copper conductor FR cable 1100 Volts grade including 1 x 10 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire drawn through conduit /casing caping and connecting to common earth terminals to existing DBs complete all as specified and as directed. Note :- (i) four runs of copper cable and Two run of earth wire including conduit /PVC casing/caping shall be measured as one length.
Supply and install 1.5 ton Split AC with inverter compressor hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality energy efficient with 5 star rating.
M & L for sub main wiring with 2 single core, 4 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FRLS cable 1100 Volts grade incl 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor FRLS as continuous earth wire and connecting to common earth terminals complete all as specified and directed in conduits/ PVC capping- casing. Note :-(i) Two run of copper cable and one run of earth wire shall be measured as one length. (ii)Rate of casing-capping/ conduit deemed to be included in rate quoted.
All as Item No-35 above but with 2x 6.0 sqmm with 4.0 sqmm earth wire.
Supply and fix in repairs sheet metal enclosure DBs SPN, 240V with 200 Amps rated bus bars double door complete all as specified and as directed of following sizes:- (a) 4 Ways
Supply and fixing 40 to 63 Amps rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN in the MCB DB complete with connection testing and commissioning. Make L&T/ABB/SIEMENS/ LEGRAND
Supply and fixing 5 to 32 Amps rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP in the MCB DB complete with connection testing and commissioning. Make L&T/ABB/ SIEMENS / LEGRAND
S & F Plug & socket enclosure in sheet metal enclosure with 20A SP MCB complete all as specified and as directed.
Supply and fix wall mounted bracket for split AC outer unit duly powder coated and factory Made.
M&l for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including necessary excavation & earthwork in any type of starter.
Supply and fix aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point all as specified.
Supply and fix galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe.
Supply and fix single pointed air termination Aluminium rod 12mm dia, 300 mm long
M&L for test point terminal block made of gun metal or phosphorous bronge 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point completed all as specified.
M&L for Pre-cast cement concrete block masonry with solid blocks, type B1 1:2:4 (using 20mm graded stone aggregate) of approx size of 10x10x10CuCm for supporting Aluminium/ Iron Strips on the roof for lightening protection.
M&L for earthing complete with galvanized earth electro of size 600X600X6mm thick buried directly in ground, earth pit not less than 2.25m deep below normal GL with top edge of the earth plate not less than 1.25m below GL connected with earth strip 32 x 6 by means of check nuts, bolts, nuts, washers of GI all as shown in plate no. 3 of MES sch. Pt 0I, connected to earthing test point necessary excavation, earth work, PCC, RCC cover, watering by funnel etc., all as specified and directed by Engineer-in-Charge complete including testing on completion
Note: Amount of sch of credit of Rs.7,930.00/-will be deducted from total amount of BOQ.
M/s Nilesh Enterprises
Alpha Construction
M/S SAMEER SUBHASH PATANI
N K ASSOCIATES
M/s. JBSR ENTERPRISES.
M/S R.K.S. CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .