Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹33.9 LAccepted-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | 1 | Accepted-AOC BEING LOWEST TENDERER AND FULFILLING ALL THE REQUISITE CRITERIA | |
| 2 | 2₹35.6 L+₹68,509.30 (1.96%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | 2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | 3₹43.1 L+₹8.2 L (23.6%)Rejected-Finance OLD NO 338 NEW NO 17 19TH NEDUMANEHLIAN STREET G K M COLONY CHENNAI 600 082 | CHENNAI | CHENNAI | TAMIL NADU | 600082 | 3 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 4 | 4₹43.9 L+₹9.0 L (25.9%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | 4 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 5 | Rejected-Technical 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | - | Rejected-Technical CONTRACTOR IS NOT FULFILLING ALL THE CRITERIA |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
25 Dec 2024, 6:00 pmClosed
GARRISON ENGINNER
GE CHENNAI Fort Saint George Chennai- 600009
REPAIRS/REPLACEMENT OF LT PANEL BOARDS / DISTRIBUTION FEEDER PILLAR BOXES AND CONTROL PANELS AT A, B AND D AREA UNDER GE CHENNAI
2024_MES_685891_1
8776
Open Tender
Civil Works
Item Rate
273 days
GE CHENNAI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE CHENNAI
₹70,000
Yes
4 Feb 2025
27 Nov 2024
1 Jan 2025
27 Nov 2024
25 Dec 2024
11 Dec 2024
Amount
Excavation in trenches not exc 1.5m in width and 1.5 m in depth and getting out excavated soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and as directed.
Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply and lay fine sieved excavated dry soil cushioning spreading levelling for cable trenches complete all as specified and directed. (Note: Punned thickness only shall be measured and paid.)
Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable complete all as specified and directed.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 95 sqmm x 3.5 core from trenches/ walls (or) passing through pipes/in floor, removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing complete all as specified and directed. Note:- Excavation and Earth work shall be measured and paid separately under appropriate item.
All as per item No.6 above but 150sqmm 3.5 core
All as per item No.6 above but 185 sqmm 3.5 core
All as per item No.6 above but 240 sqmm 3.5 core
Laying only the under ground cable any type obtained from Items No -06 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 95 sqmm 3.5 core complete all as specified and directed .
Laying only the under ground cable any type obtained from Items No -07 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 150 sqmm 3.5 core complete all as specified and directed .
Laying only the under ground cable any type obtained from Items No -08 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 185 sqmm 3.5 core complete all as specified and directed .
Laying only the under ground cable any type obtained from Items No -09 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc, size 240 sqmm 3.5 core complete all as specified and directed .
Supply & Lay in trenches, fixed on wall (or) passing through pipes/in floors, connecting up, testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 95 sqmm 3.5 core complete all as specified and as directed.
All as per item No. 14.00 above but 150sqmm 3.5 core
All as per item No. 14.00 above but 185sqmm 3.5 core
All as per item No. 14.00 above but 240sqmm 3.5 core
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable including taking down old existing one of size 95 sqmm 3.5 core complete all aspspecified and as directed.
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable including taking down old existing one of size 150 to 185 sqmm 3.5 core complete all aspspecified and as directed.
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable including taking down old existing one of size 240 to 300 sqmm 3.5 core complete all aspspecified and as directed.
M & L for GI pipe light grade of size 100mm in trenches /fixed on walls by suitable clamps and jointing including taking down existing old pipes complete all as specified and as directed.
S&F for PCC type C1 1:3:6 (20mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Fabrication and installation of cable route indicator made out of 10 mm thick CI plate , oval shape of suitable size and embossed with Mark of "MES LT Cable " including 30 cm length angle iron support and embedded in and including PCC,including taking down existing old one complete all as specified and as directed.
S& F for GI earthing strip 25x4 mm with nut and bolts complete including taking down old one all as specified and directed.
S&F of GI Strip ISI marked of size 32 x6 mm complete with nuts, bolts and washers, buried in ground including excavation and taking down existing old ones complete and all as specified and directed.
S & F Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 2 KVAR including MCCB and taking down existing old ones complete all as specified and directed
S & F Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 5 KVAR including MCCB and taking down existing old ones complete all as specified and directed
S & F Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 10 KVAR including MCCB and taking down existing old ones complete all as specified and directed
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar of outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. Including taking down the old panel required at site and comprising following:- Note :- (i) The rate deemed to be inclusive of disconnecting the LT cable and reconnecting the same with suitable size of cable glands and connecting complete. (ii) LT danger notice with conventional skull and bones indication written with English and local language.
Incoming (a) S&F for Electrolytic grade high conductivity solid 4 Nos Alu bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable PVC sleeves. The bars shall be colour coded at required intervals for identification - 04 Nos (b ) S&F for LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (C ) S&F Digital Multi Function meter Nos -01 (d ) S&F for MCCB 400 Amp 36 KA 4 pole Thermal magnetic setting complete - N0s -01 Outgoing (a ) S&F MCCB of 4 pole of capacity 100 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 04 Nos (b ) S&F MCCB of 4 pole of capacity 125 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 04 Nos
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar of outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. Including taking down the old panel required at site and comprising following:- Note :- (i) The rate deemed to be inclusive of disconnecting the LT cable and reconnecting the same with suitable size of cable glands and connecting complete. (ii) LT danger notice with conventional skull and bones indication written with English and local language.
Incoming (a) S&F for Electrolytic grade high conductivity solid 4 Nos Alu bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable PVC sleeves. The bars shall be colour coded at required intervals for identification - 04 Nos (b ) S&F for LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (C ) S&F Digital Multi Function meter Nos -01 (d ) S&F for MCCB 350 Amp 36 KA 4 pole Thermal magnetic setting complete - N0s -01 Outgoing (a ) S&F MCCB of 4 pole of capacity 63 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 02 Nos (b ) S&F MCCB of 4 pole of capacity 160 amps, with breaking capacity of 36 KA with fixed thermal & fixed magnetic setting - 03 Nos (c ) S&F MCCB of 4 pole of capacity 200 amps, with breaking capacity of 36 KA with fixed thermal & fixed magnetic setting - 03 Nos
M&L for Repair to LT Panel board, dismantling the door and attending repair works to Hinges by providing suitable welding work, including repairs to Locking arrangement, complete including replacement of worn-out rubber beadings and covering the cable incoming and outgoing entry points with suitable MS sheets etc, and scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work over a corroded portion and coat of red oxide primer and black for base frame complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground( earth pit not less than 2.25 m deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machinery/equipments installed power house/sub station all as specified including testing on completion complete all as specified and as directed. Note: The unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.
RK ENTERPRISES (BID ID -3197030)
GK ENTERPRISES (BID ID -3192411)
EVEREST ENGINEERING WORKS (BID ID -3192397)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .