| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAdmitted-Finance | ₹5.5 L | L1 | Admitted-Finance |
| 2 | L2₹74,300Admitted-Finance | ₹74,300 | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | A.K.CONSTRUCTION CO. L1 | M/s PARAG ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00To Carry out periodic servicing, maintenance & repair of AC including replacement of all spare parts, supply and charging of fresh refrigerent and other items (i.e. AMC charges per year) for maintenance services of all Cassette ACs of various types and tonnage and complete with all materials & Labour existing in offices/buildings of Nagar Nigam Greater situated at Jaipur on comprehensive Basis, as under & all as specified & stipulated as per detailed scope of services or as directed by authorized representative of NNGJ. | |||||
| 2.002.5/3.0 Ton | |||||
| 3.00 | Cassette AC | 6 | Nos. | 7,200 ₹43,200 | 1,450 ₹8,700 |
| 4.004.0~5.5 Ton | |||||
| 5.00 | Cassette AC | 4 | Nos. | 15,300 ₹61,200 | 1,700 ₹6,800 |
| 6.00 | Providing & Fixing of New Compressor suitable for 4.0~5.5 Ton New Compressor | 2 | Nos. | 27,000 ₹54,000 | 7,200 ₹14,400 |
| 7.007.0~7.5 Ton | |||||
| 8.00 | Cassette AC | 5 | Nos. | 29,700 ₹1.5 L | 1,700 ₹8,500 |
| 9.00 | Providing & Fixing of New Compressor suitable for 7.0~7.5 Ton New Compressor | 2 | Nos. | 60,300 ₹1.2 L | 8,100 ₹16,200 |
| 10.00 | Replacement of defective PCB of suitable make for 1.5/2.0 TR AC. | 35 | Nos. | 2,970 ₹1.0 L | 400 ₹14,000 |
Tender Value
₹37.2 L
EMD Value
₹74,420
Closing Date
26 Feb 2026, 6:00 pmClosed
EXECUTIVE ENGINEER LIGHT
JAIPUR NAGAR NIGAM PANDIT DEENDAYAL UPPADHYAY BHAWAN LALKOTHI TONK ROAD JAIPUR
Maintenance work (with accessories) of AC related to Murlipura, Vidhadhar Nagar, Jhotwara, Vaishali Nagar, Mansarovar, Sanganer, Jagatpura, Jhalana and Malviya Nagar zone All fire stations, all community centers, all garage offices and headquarters
2026_DLB_539221_1
141 EXECUTIVE ENGINEER LIGHT
Open Tender
Electrical and Maintenance Works
365 days
JAIPUR
As Per Bid Documents
3 documents required · 3 mandatory
₹500
ONLINE PAY IN JAIPURMC WEBSITE
₹74,420
6 Mar 2026
17 Feb 2026
27 Feb 2026
17 Feb 2026
26 Feb 2026
17 Feb 2026
To Carry out periodic servicing, maintenance & repair of AC including replacement of all spare parts, supply and charging of fresh refrigerent and other items (i.e. AMC charges per year) for maintenance services of all Cassette ACs of various types and tonnage and complete with all materials & Labour existing in offices/buildings of Nagar Nigam Greater situated at Jaipur on comprehensive Basis, as under & all as specified & stipulated as per detailed scope of services or as directed by authorized representative of NNGJ.
Cassette AC
Cassette AC
Providing & Fixing of New Compressor suitable for 4.0~5.5 Ton New Compressor
Cassette AC
Providing & Fixing of New Compressor suitable for 7.0~7.5 Ton New Compressor
Replacement of defective PCB of suitable make for 1.5/2.0 TR AC.
Providing of remote as per model of existing of suitable make for 1.5/2.0 TR AC.
Percentage BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (Part-B) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) (BSR Items 2023)
NUMBER #
(71.38) Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATCdrain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Un Armoured
(71.38.1.3) 2 core x 2.5 Sq.mm
(71.39) Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(71.39.8) 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
(71.39.10) 9.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
(71.4) Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(75.42) Supplying and charging of fresh refrigerant and testing of performance of air conditioner/ fridge/ water cooler of following capacity including capillary and strainer/ filter.
(75.42.2) 1.5 TR Window/ Split A.C.
(75.42.3) 2.0 TR Window/ Split A.C.
(75.43) Replacement of defective compressor by company repaired compressor as per OEM recommendations of following gadgets including testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
(75.44) P & Replacement of condensing/ cooling coil of copper fins for following capacity A.C./ Water cooler/ Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
(75.45) Servicing of 1.0/1.5/2.0 TR capacity Split/ Window type air conditioner
(75.46) P & Replacement of overload protection of A.C./ Water cooler as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
(75.47) P & Replacement of thermostat of A.C./ Water cooler/fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
(75.49) P & Replacement of starting relay of A.C/water cooler/fridge compressor as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
(75.71) P & Replacement of fan motor of evaporator/ condensor complete as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
(75.72) S & F of capacitor of 230V/ 275V, 50Hz rating of plastic casing and terminals -Lugs or copper wire.
(75.72.1) Starting capacitor
(75.72.1.3) 60-80 micro farad
(75.72.1.4) 80-100 micro farad
(75.72.2) Running capacitor
(75.72.2.3) 6.0 micro farad
(75.72.2.4) 8.0 micro farad
(61.5) Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
(61.5.1) 100mm x 50mm x 1.6mm
(61.5.2) 150mm x 50mm x 1.6mm
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
EPROC141XENLIGHT.pdf
Tender Documents • 5.46 MB
BOQ_961950.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid