| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹11.5 L+₹20,637 (1.79%)Accepted-AOC | L2 | Accepted-AOC Rejected | |
| 3 | L3₹12.3 L+₹96,552 (8.38%)Accepted-AOC | L3 | Accepted-AOC Rejected | |
| 4 | L4₹12.6 L+₹1.3 L (11.7%)Accepted-AOC | L4 | Accepted-AOC Rejected |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
9 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Leh
GE (AF) Leh C/O 56 APO
CERTAIN PETTY REPAIRS MAINTENANCE TO INTERNAL ELECTRIC SERVICES IN DOMESTIC AREA AT AF STN LEH
2022_MES_537310_1
GE(AF)/LEH-18/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Leh
As Per Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Leh
₹30,000
Yes
18 Oct 2022
12 Jul 2022
11 Aug 2022
12 Jul 2022
9 Aug 2022
26 Jul 2022
Amount
Taking down carefully copper/Aluminium point wiring (Light,fan,socket or power) complete including fitting such as switches, socket, bell pushes, ceiling roses, pendants/batten holder, call bell, regulators etc, complete all as specified and directed by Engineer-in-Charge.
Point wiring with multi stranded FRLS PVC indulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC casing caping (medium grade) of suitable size, fixed on wall / ceiling surface, terminated in pressed steel sunken box as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/ fan bell point controlled by one way switch using proper colour coding, complete all as specified and as directed by Engineer-in- Charge. Note : (a) wiring shall be done by using proper colour coding.
All as per Sl item no.2 above but for one socket outlet point 5 amps on independent board controlled by one, one way switch.
All as per Sl item no.2 but for one socket outlet point on same the baord with other switches.
Point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge. Note : (a) wiring shall be done by using proper colour coding.
Switch piano flush type , SP,5/6 Amps, one way ,complete all as specified and as directed by Engineer-in- Charge.
Bell push, flush type 5 Amps One Way 230 volts ,complete all as specified and as directed by Engineer-in- Charge.
Socket out let 2 in 1 socket 3 pin , 6 & 16 Amps flush type controlled by one switch ,complete all as specified and as directed by Engineer-in- Charge.
Socket out let 2 in 1 socket 3 pin , 6 Amps flush type controlled by one switch ,complete all as specified and as directed by Engineer-in- Charge.
Switch piano flush type , SP,15 Amps, one way ,complete all as specified and as directed by Engineer-in- Charge.
Ceiling rose 3 terminal size 50x65mm surface type 230 volts ,complete all as specified and as directed by Engineer-in- Charge.
Bell ding dong AC SP 230 volts ,complete all as specified and as directed by Engineer-in- Charge.
Lamp Holder insulated body with back plate for batten fitting suitable for LED lamp complete all as specified and directed by Engineer-in-Charge.
S&F Crystal glass LED tube light of 18W T8 , 4ft. (double side connection with LED driver) with very high efficacy suited for installation in existing tubelight G13 lamp holders to give glare free light complete all as specified and directed by Engineer-in-Charge.
S&F universal Regal batten for LED tube Double side connection Complete 1x22 Watt.
LED Adore Lamp 9/10W, B22 base 6500K CDL type ,complete all as specified and directed by Engineer-in-Charge.
Sub main wiring with two single core 2.5 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including PVC casing caping and accessories including one single core 2.5 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete in and including taking down of old unservicable sub main wiring, complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 2.5 Sqmm ,1 run of PVC casing caping & 1 run of 2.5 Sqmm earth cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Sub main wiring with two single core 4 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including PVC casing caping and accessories including one single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete in and including taking down of old unservicable sub main wiring, complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 4 Sqmm ,1 run of PVC casing caping & 1 run of 4 Sqmm earth cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Sub main wiring with two single core 6 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including PVC casing caping and accessories including one single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete in and including taking down of old unservicable sub main wiring, complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 6 Sqmm ,1 run of PVC casing caping & 1 run of 6 Sqmm earth cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
MCB SPN, 32 Amps, 240 Volts ,10 KA to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
MCB SP, 6 to 32 Amps, ,240 Volts ,10 KA to be housed in DBs of Proper and suitable size cable lugs to be fixed with MCBs ,complete all as specified and directed by Engineer-in- Charge.
Taking down old unserviceable main switches/ Distribution board any type including fuses MCB etc after removing all connection and making good the disturb surface all as directed by Engineer-in-charge.
Distribution box Double door type , SPN 8 way,with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door ,epoxy powder coated in and including taking down of old unservicable main switches /Distribution board including fuses MCBs after removing all connection and making good the disturb surfaces ,complete all as specified and as directed by Engineer-in- Charge.
Distribution box Double door type , SPN 4 way,with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door ,epoxy powder coatedin and including taking down of old unservicable main switches /Distribution board including fuses MCBs after removing all connection and making good the disturb surfaces ,complete all as specified and as directed by Engineer-in- Charge.
Distribution box Double door type , TPN 4 way,with required rated bus bar, 415/430 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door ,epoxy powder coated in and including taking down of old unservicable main switches /Distribution board including fuses MCBs after removing all connection and making good the disturb surfaces ,complete all as specified and as directed by Engineer-in- Charge.
MCB TPN, 63 Amps, 415 Volts ,50 Hz ,25 KA to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Lumiline LED 10/9W LED 6000K (2 ft.) tube light fitting Wall mounted LED batten with rod, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver with polycorbonate housing complete with accessories internally pre wired and including connecting up with twin core twisted copper conductor cable with suitable size in and including taking down of old unservicable fitting, complete all as specified and directed by Engineer-in-Charge.
Energy saving new generation Endura Rugby Neo - IP65, 10W LED IP65 bulkhead luminaire with opal diffuser, etc complete with all accessories rewired electrically connected in and including taking down of old unservicable fitting, complete all as specified and directed by Engineer-in-Charge.
ENDURA Slim Pro Plus PANEL 36W LED 5700K LED fitting with LED prisumatic optival modular luminaire suitable for Reccesses mounting complete with HF electronic driver in and including taking down of old unservicable fitting, complete all as specified and directed by Engineer-in-Charge.
Moduler switch 1 way 6A, 1 modules square white mechanisms as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Moduler socket 6 Amps, 2/3 Pin combined, 2 module as in replacement,complete all as specified and as directed by Engineer-in- Charge.
Moduler socket 6/16 Amps, 2/3 Pin combined, 2 module as in replacement,complete all as specified and as directed by Engineer-in- Charge.
36W LED 4000K, Symmetrical Distribution flood light Energy saving IP65 luminaire with high power for bldg security light in and including taking down of old unservicable fitting, complete all as specified and directed by Engineer-in-Charge.
Earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 4 dia G I wire by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, reinforced XPM of weight not less than 4 kg/ Sq.m and MS frame etc. including taking down of old unserviceable earthing, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
Attending the complaints of electrification nature rectification of the fault as per the complaint lodged by the user in respect of main distribution board having switch fused, MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan/bell/light or power socket complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, suck boxes, juction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty sotres such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tap, screws, nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantledat to the entire satisfaction of Engr-in-charge/users ,complete all as specified and directed by Engineer-in-Charge. NOTE : (a) Items replaced shall be measured seprately. (b) All the necessary T&P and transport required for repair shall be provided by the contractor. (c) The complaints of internal electric of one qtr will be considered one Job. (d) The penalty shall be applicable to the contractor if the delay is noticed by Engineer-In Charge more than 12 Hrs after handing over the work of urgent nature to the contractor. (e) Please not that this penalty is exculsively other than conditions 56 IAFW-2249 & shall be treated as interim condition of the contract & Shall inforceable as an delay in individual job is noticed & no cliam whatever on his account shall be entertained by the dept. The decision of the accepting officer in this regard shall be final & binding.
Supply only MCB SPN 32A, 240 V -10 KA complete with all accessories as required on site ,complete all as specified and directed by Engineer-in-Charge.
Supply only MCB SP 6-32A, 240 V -10 KA complete with all accessories as required on site ,complete all as specified and directed by Engineer-in-Charge.
Supply only MCB 32 Amp TPN 415 volts 50 Hz 25 KA, complete with all accessories as required on site & as directed by engineer-in-charge.
Supply only MCB 63 Amp TPN 415 volts 50 Hz 25 KA, complete with all accessories as required on site ,complete all as specified and directed by Engineer-in-Charge.
Supply only Sheet metal enclosure double door for DB's SPN 8 way 240 V having 200 A rated bus bar complete with all accessories as required on site ,complete all as specified and directed by Engineer-in-Charge.
Supply only Sheet metal enclosure double door for DB's SPN 4 way 240 V having 200 A rated bus bar ,complete all as specified and directed by Engineer-in-Charge.
Supply only Sheet metal enclosure double door for DBs TPN 4 way 415 Volt having 200 A rated bus bar ,complete all as specified and directed by Engineer-in-Charge.
Supply only Lamp Holder insulated body with back plate for batten fitting suitable for LED lamp ,complete all as specified and directed by Engineer-in-Charge.
Supply only Crystal glass LED tube light of 18W T8 , 4ft. (double side connection with LED driver) with very high efficacy suited for installation in existing tubelight G13 lamp holders to give glare free light ,complete all as specified and directed by Engineer-in-Charge.
Supply only universal Regal batten for LED tube Double side connection Complete 1x22 Watt ,complete all as specified and directed by Engineer-in-Charge.
Supply only LED tube light 1x20 watt T-8, epoxy powder coated CRCA sheet housing with reflector cover channel, prewired with 3 core copper cable of size-23/.0076 from ceiling tube rod of 18/20 watt fixed on wall/ ceiling for surfaced pendant mounting in and including taking down of old unserviceable light fitting, complete all as specified and directed by Engineer-in-Charge.
Supply only Switch piano, flush type 5 Amps One Way 230 volts complete all as specified.
Supply only Socket outlet 2-in-1 3 pin 6 Amps flush type 230 volts ,complete all as specified and directed by Engineer-in-Charge.
Supply only switch socket combination with PVC box 2-in-1 3 pin 6 & 16 Amps flush type 230 volts ,complete all as specified and directed by Engineer-in-Charge.
Supply only switch socket combination with PVC box 2-in-1 3 pin 6 Amps flush type 230 volts ,complete all as specified and directed by Engineer-in-Charge.
Supply only LED Adore Lamp 9/10W, B22 base 6500K CDL type ,complete all as specified and directed by Engineer-in-Charge.
Supply only switch socket combination 2-in-1 3 pin 5 & 15 Amps flush type 230 volts ,complete all as specified and directed by Engineer-in-Charge.
Supply only switch socket combination 2-in-1 3 pin 5 Amps flush type 230 volts ,complete all as specified and directed by Engineer-in-Charge.
Supply only service wire of 10 sqmm 2 core, 1100 volts with multistranded aluminium conductor, complete all as specified and directed by Engineer-in-Charge.
Supply only FRLS PVC insulated unsheathed stranded copper conductor wire single core of size 1.50 sqmm, complete all as specified and directed by Engineer-in-Charge.
Supply only FRLS PVC insulated unsheathed stranded copper conductor wire single core of size 2.50 sqmm ,complete all as specified and directed by Engineer-in-Charge.
Supply only FRLS PVC insulated unsheathed stranded copper conductor wire single core of size 4.00 sqmm ,complete all as specified and directed by Engineer-in-Charge.
Supply only FRLS PVC insulated unsheathed stranded copper conductor wire single core of size 6.00 sqmm ,complete all as specified and directed by Engineer-in-Charge.
Supply only hylem sheet cover 3mm thick of size 4" x 4" ,complete all as specified and directed by Engineer-in-Charge.
Supply only hylem sheet cover 3mm thick of size 6" x 4" ,complete all as specified and directed by Engineer-in-Charge.
Supply only hylem sheet cover 3mm thick of size 8" x 4" ,complete all as specified and directed by Engineer-in-Charge.
Supply only PVC Casing & Caping of size 1.0" (ISI Marked) including all fixing accessories, complete all as specified and directed by Engineer-in-Charge.
Supply only PVC Casing & Caping of size 1.5" (ISI Marked) including all fixing accessories ,complete all as specified and directed by Engineer-in-Charge.
Supply only Insulation tape of size 1.8cm x 8 mtr x 0.125mm, best quality (30 rolls in a box) ,complete all as specified and directed by Engineer-in-Charge.
Note : Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents
osho traders
J K Sales and Construction Corporation
Hitech Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .