Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | Admitted-Finance |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
4 Apr 2020, 6:00 pmClosed
AGE (I) Asvini
AGE (I) Asvini
REPAIR / REPLACEMENT OF CERTAIN PARTS OF VRF PLANTS (OFFICERS WARD, OFFRS FAMILY WARD AND SAILORS FAMILY WARD AT TERRACE OF BLDG NO P-72 AT INHS ASVINI
2020_MES_333532_1
8256/E8
Open Tender
Miscellaneous Works
Item Wise
180 days
AGE (I) Asvini
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
AGE (I) Asvini
₹19,200
Yes
9 Jun 2020
12 Mar 2020
6 Apr 2020
12 Mar 2020
4 Apr 2020
18 Mar 2020
Amount
Disconnecting carefully all electrical connections of VRF plant of any make and capacity, discharging gas from out door unit and taking out VRF plant from existing place & shifting to new location as directed, removing the dust from body with blower, servicing condensor coils and compressor, reservoir areas completly and wet servicing by using approved chemicals by OEM manufacturer and re assembling setting all parameters by using softwares through an OEM Engineer, checking all the connections and after reparing of roof leakege work refixing the VRF plant to its original place including testing commissioning of out door unit complete all as specified & directed by Engineer-in-charge. Note :Spare Parts and Refrigerant gas will be measured & paid saperately under respective items
Supply, fixing, testing & commissioning of 32 to 42mm dia refrigerant copper pipes including all fittings like bends, elbows, tees with all internal joints type fittings laid in GI trays with mirror finish inside /outside including thermal insulation suitable for VRV system with 19mm class "0" Armaflex nitrile rubber insulation and tested for requisite pressure and supported at every 2.4mtrs of intervals complete all as specified and directed by Engineer-in-Charge.
- Ditto- all as per item no 2 above but 19-25 mm dia pipe.
M&L for charging of refrigerator gas R-410A after vaccuming / pressure and leaking testing complete all as specified.
S & F inverter board suitable for out door unit of Model No : PUHY-P450YHM-A
S & F fan board suitable for out door unit of Model No : PUHY-P450YHM-A
S & F noise filter suitable for out door unit of Model No : PUHY-P450YHM-A
S & F MNET board suitable for out door unit of Model No : PUHY-P450YHM-A
Supply and fixing control board for out door unit Model No PUHY-P450YHM-A
S & F motor suitable for out door unit of Model No PUHY-P450YHM-A
S & F indoor unit controller board suitable for indoor unit of Model No: PLFY-P80 VBM-E.
S & F indoor coil thermistor suitable for indoor unit of Model No: PLFY-P80 VBM-E.
S and F PVC indoor grill suitable for indoor unit of Model No: PLFY-P80 VBM-E
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .