Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹82.6 L+₹2.8 L (3.54%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹1.1 Cr+₹32.4 L (40.6%)Admitted-Finance LIG 172 BRIT COLONY NAYAPALLI NAYAPALLI BHUBANESWAR ODISHA 751012 | KHORDHA | ODISHA | 751012 | L3 | Admitted-Finance | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Mohapatra Cooling Systems L3 | M/S SUMITRA REFRIGERATION AND ELECTRICAL L2 | EA TECHNOLOGY L1 |
|---|---|---|---|---|---|---|
| 1.00Description | ||||||
| 2.00 | SITC of Full Inverter VRF System with Modular type outdoor units (Top Discharge) , all scroll DC Inverter compressors for Cooling & Heating applications along with different types of indoors compitable with VRF ODUs with R 410 A . All inverter capacity controlling compressors shall be suitable for 3 Phase, 50 Hz.. The outdoor fins should be with corrosion resistant chemical coating at factory only alongwith hydrophilic coating to shield it from Salt, Sand & other elements brought in by the air. The manufacturer must be OEM of its compressor, which is fitted in the VRF outdoor unit. It can work upto 53 Degree Celsius. All proposed outdoor unit should have minimum COP of 3.4 at 100% load condition for Cooling in standard AHRI test conditions (Ambient DBT-35 Deg C, Inside DBT 27 Def C/WBT 19 Deg C). Proposed outddor unit system should not have any deration in cooling capacity upto 39 Degree C ambient temepetrure -Make Mitsubishi Heavy Duty Industries(MHI) , Daikin , LG & O-General | 1 | nos | - | - | 1,001 ₹1,001 Lowest |
| 3.00 | Capacity: 14 HP | 1 | Nos. | 4,27,889.13 ₹4,27,889.13 | 3,15,112.15 ₹3,15,112.15 Lowest | 3,30,560.64 ₹3,30,560.64 |
| 4.00 | Capacity: 16 HP | 2 | Nos. | 4,54,345.74 ₹9,08,691.48 | 3,34,595.7 ₹6,69,191.4 Lowest | 3,51,800.58 ₹7,03,601.16 |
| 5.00 | Capacity: 20 HP | 2 | Nos. | 5,73,949.38 ₹11,47,898.76 | 4,22,675.9 ₹8,45,351.8 | 4,03,781.7 ₹8,07,563.4 Lowest |
| 6.00 | Capacity: 22 HP | 3 | Nos. | 5,90,260.14 ₹17,70,780.42 | 4,34,687.7 ₹13,04,063.1 | 4,21,644.9 ₹12,64,934.7 Lowest |
| 7.00 | ODU Kiit | 4 | Nos. | 14,616.99 ₹58,467.96 | 10,764.45 ₹43,057.8 Lowest | 11,300 ₹45,200 |
| 8.00 | SITC of The Indoor units suitable for operation on 220V-240V, Single Phase, 50 Hz AC electric supply and shall have shall have electronic control valves to control refrigerant flow with washable Filters,BLDC motors.Make: -Mitsubishi Heavy Duty Industries(MHI) , Daikin , LG & O-General | 1 | nos | - | - | 1,001 ₹1,001 Lowest |
| 9.00 | 1.0 TR - Hi Wall AC | 4 | Nos. | 31,992 ₹1,27,968 | 23,560 ₹94,240 Lowest | 23,743 ₹94,972 |
| 10.00 | 2.0 TR - Hi Wall AC | 1 | Nos. | 39,216 ₹39,216 | 28,880 ₹28,880 | 25,325 ₹25,325 Lowest |
Tender Value
₹1 Cr
EMD Value
₹1 L
Closing Date
15 Apr 2024, 5:00 pmClosed
SE(CIVIL)
CIVIL WORKS CIRCLE,OPTCL,BBSR
PROCUREMENT AND INSTALLATION OF AC FOR MS BUILDING AT BERHAMPUR
2024_OPTCL_102752_1
E-TENDER NOTICE NO- 18 OF 23-24
Open Tender
Civil Works - Buildings
Item Rate
60 days
BERHAMPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹12,000
SE(CIVIL),CIVIL WORKS CIRCLE,OPTCL
₹1 L
Yes
CIVIL WORKS CIRCLE,OPTCL,BBSR
5 Jun 2024
19 Mar 2024
16 Apr 2024
19 Mar 2024
15 Apr 2024
19 Mar 2024
19 Mar 2024 - 10 Apr 2024
10 Apr 2024
Amount
Description
SITC of Full Inverter VRF System with Modular type outdoor units (Top Discharge) , all scroll DC Inverter compressors for Cooling & Heating applications along with different types of indoors compitable with VRF ODUs with R 410 A . All inverter capacity controlling compressors shall be suitable for 3 Phase, 50 Hz.. The outdoor fins should be with corrosion resistant chemical coating at factory only alongwith hydrophilic coating to shield it from Salt, Sand & other elements brought in by the air. The manufacturer must be OEM of its compressor, which is fitted in the VRF outdoor unit. It can work upto 53 Degree Celsius. All proposed outdoor unit should have minimum COP of 3.4 at 100% load condition for Cooling in standard AHRI test conditions (Ambient DBT-35 Deg C, Inside DBT 27 Def C/WBT 19 Deg C). Proposed outddor unit system should not have any deration in cooling capacity upto 39 Degree C ambient temepetrure -Make Mitsubishi Heavy Duty Industries(MHI) , Daikin , LG & O-General
Capacity: 14 HP
Capacity: 16 HP
Capacity: 20 HP
Capacity: 22 HP
ODU Kiit
SITC of The Indoor units suitable for operation on 220V-240V, Single Phase, 50 Hz AC electric supply and shall have shall have electronic control valves to control refrigerant flow with washable Filters,BLDC motors.Make: -Mitsubishi Heavy Duty Industries(MHI) , Daikin , LG & O-General
1.0 TR - Hi Wall AC
2.0 TR - Hi Wall AC
1.0 TR - Compact Cassette AC
1.5 TR - Compact Cassette AC
2.0 TR - 4Way Cassette AC
2.5 TR - 4Way Cassette AC
3.0 TR - 4Way Cassette AC
3.5 TR - 4Way Cassette AC
4.0 TR - 4Way Cassette AC
4.5 TR - 4Way Cassette AC
8.0 TR - Hi Static Ductable AC
Cassette Pannel
IR-Receiver for Ductable AC
Wireless Remote
Supply of Y-Branches
SITC of 5 inch touch screen Central Controller with individual & group control, error check, scheduling, emergency stop, support minimum 64 units
SITC of the Cu. refrigerant pipes with 19mm/13mm with nitrile rubber tube insulation of following sizes Make: Nippon/ Ravi Tubes/ Mandev/ Total Line
Gas line with 19mm thick insulation
Liquid line with 13mm thick insulation
Control & Transmission Wiring
Supply Installation Testing and Commission of Control wiring of 2 core x 1.5 sqmm copper in suitable conduits between indoor and outdoor units. Make: Polycab/ Havells/ Anchor/ RR Cabel/ Finolex
Supply Installation Testing and Commission of PVC drain pipe with 6mm thick nytrile tube insulation.Make: Supreme/ Finolex or equivalent
SITC of fabricated G.S.S. rectangular ducting complete with neoprene rubber gaskets, elbow, splitter dampers, vanes, hangers, supports etc as per approved drawings and specifications of following sheet thickness complete as required. Make: Sail/ Jindal/ Tata
Acoustic Lining of Duct
SITC of Acoustic lining of supply air duct and plenum with 12mm thick resin bonded glass wool having density 32 Kg/CuM, with 25 mmX 25 mm GI section of 1.25 mm thick, at 600 mm center to center covered reinforced plastic Tissue paper & 0.5 mm thick perforated Aluminium sheet
Duct Insulation
SITC of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (class O) insulation on existing duct after applying two coats of cold setting adhesive (CPRX compoun) . The joint shall be sealed with 50 mm wide 3 mm thick self adhesive nitrile rubber tape insulation complete as per specification and as required.
Supply, installation, testing and commissioning of Powder Coated Extruded Aluminium Grill
Commissioning of VRF systems including topping R410A gas as per site requirements
Supply & Installation of Galvanised Steel Slotted Tray for copper piping for the safety of nytrile insulations over copper pipe. ( For the exposed Area only)
50mmx300mm X 50mm
50mmx450mm X 50mm
MS stand for Outdoor Unit
Lifting,shifting & scraffolding as required
SITC of Air Curtain for Main Entrance ( 900mm )
M/S SUMITRA REFRIGERATION AND ELECTRICAL
Mohapatra Cooling Systems
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .