Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.1 CrAccepted-AOC 142 SALAMANGALAM VILLAGE VANDALUR WALLAJABAD HIGH ROAD KANCHEEPURAM DISTRICT PADAPPAI 601301 | PADAPPAI | KANCHEEPURAM | TAMIL NADU | 601301 | L-1 | Accepted-AOC As per decision of PPC, order placed on L-1 firm. | |
| 2 | L-2₹1.1 Cr+₹10,999.99 (0.10%)Rejected-Finance 2ND ROSHAN TOWER S B SHOP BISTUPUR AREA EAST SINGHBHUM JHARKHAND | BISTUPUR | EAST SINGHBHUM | JHARKHAND | 831001 | L-2 | Rejected-Finance L-2 firm |
Tender Value
Refer Docs
EMD Value
₹3 L
Closing Date
30 Nov 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dy. CE/HPs.
Shed A-3, Shakti Vihar, PSPCL, Patiala.
DESIGN, MANUFACTURE, SUPPLY, ERECTION, TESTING AND COMMISSIONING OF C and R PANELS OF 132 KV FEEDERS, POWER TRANSFORMERS AND BUS COUPLER FOR THE REPLACEMENT OF EXISTING C and R PANELS AT UBDC POWER HOUSE NO.3 STAGE I.
2022_POWER_87545_1
289/HPs/ED-III/M-139
Open Tender
Electrical Goods/Equipment
Tender cum Auction
180 days
UBDC Hydel Project, Malikpur
Please refer Tender Documents
9 documents required · 9 mandatory
₹0
₹3 L
Yes
19 Jul 2023
7 Jul 2022
6 Dec 2022
7 Jul 2022
30 Nov 2022
7 Jul 2022
180 days
Amount
Part I : Supply
Design & Supply of 132/11 KV 20 MVA and 132/66Kv 40/50MVA Power transformer outgoing Feeder control and relay Panel with 220 Volts DC Control supply consisting of Over current protection, restricted earth fault protection relays, Differential protection relay, necessary auxiliary relays for alarm, indications and trippings ,supervision relays, trip and alarm facia, full control wiring inside panel for 132 KV SF6 spring closing spring tripping circuit breaker including any other item required for full operation of the C&R Panel all as per Technical specification Section III.1
Design & Supply of 132 kv Bus coupler control and relay Panel with 220 Volts DC Control supply consisting of Distance protection relay , Over current protection, earth fault protection relays, necessary auxiliary relays for alarm, indications and trippings ,supervision relays, trip and alarm facia, full control wiring inside panel for 132 KV SF6 spring closing spring tripping circuit breaker including any other item required for full operation of the C&R Panel all as per Technical specification Section III.2
Design & Supply of 132 KV outgoing Feeder control and relay Panel with 220 Volts DC Control supply consisting of Over current protection, earth fault protection relays, Distance protection relay, necessary auxiliary relays for alarm, indications and trippings, supervision relays , trip and alarm facia, full control wiring inside panel for 132 KV SF6 spring closing spring tripping circuit breaker including any other item required for full operation of the C&R Panel all as per Technical specification Section III.3
Part II : Erection and commissioning
Dismantlement, Erection, Testing and commissioning of the Panels of the above stated Panels all as per Technical Specification
Bidder Name
Amount in Words
GE T and D India Limited
SiemensLtd
GE T and D India Limited
stage.html
html • 0.04 MB
technical_187154.pdf
PDF • 0.25 MB
techsummary_187154.pdf
PDF • 0.56 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_187154.pdf
PDF • 0.68 MB
ppc2.pdf
PDF • 0.72 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .