Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹33.7 L+₹89,684 (2.73%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹33.9 L+₹1.0 L (3.15%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹40.0 L+₹7.2 L (21.9%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Nov 2022, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-41103
COMPREHENSIVE MAINTANANCE OF CEILING FANS EXHAUST FANS AIR CIRCULATORS AND APFC PANELS AT VARIOUS LOCATIONS UNDER AGE EM II IN GE CENTRAL KIRKEE
2022_MES_558919_1
8697/E8 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
512 ABW area
Class D Category b(i)
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹90,000
Yes
26 Nov 2022
20 Oct 2022
17 Nov 2022
20 Oct 2022
15 Nov 2022
3 Nov 2022
20 Oct 2022 - 2 Nov 2022
Amount
Comprehensive maintenance consisting of normal repairs and attending day-to-day complaints of following equipments at various loaction at 512 ABW, A park , Arsenal Depot ,B Park and Old Park all as directed by Engr-in-charge: (a) Exhaust fan single phase 250/280/300/380/450/600 mm sweep. (b) Air circulator fan 450/600 mm sweep single phase (c) Ceiling fan 1200/1400 mm sweep, (d) APFC panels of various capacity. (e) Wall mounting fan of any capacity. (f) Monitoring of APFC panel power factor reading and maintaining the power factor above 0.98. NOTE :- (a) Quoted rates are deemed to be inclusive of the cost of all materials and labour required for dismantling and assembling of equipment in whole or as a part thereof, cost of minor spares and material required such as grease, push button, LED indicating lamp, thimbles, different size of lugs, nuts, bolts,washers,clamp,cable gland,supporting clamp, insulation tapes etc., (b) Major defects such as motor rewinding, replacment of faulty bearings, condensor does not includes in this cost. In case of major problems beyond the scope of contract the same has to intimate to the department within 48 hours. (c) Inspection, repairing, monitoring and preparing inspection sheet of APFC panels located at various locations under AGE E/M-II GE (Central) Kirkee on alternate days per week per month. Contd....2
Contd,,from 1 The necessary shutdown to carry out the inspection and repairing of the panels will be arranged by the contractor.The format of the inspection sheet is included in the PS of this CA. In any case the power factor of each APFC panel must not be less than 0.99 (lag). The average power factor for the month for entire workshop load should be above 98 (lag) The contractor has to pin point the faults if any and reactify the same within 24 Hrs to maintain the desired power factor.The materials or (and) any kind of job required for the maintenance and rectification of the panels will be measured and paid in the relevant items of this schedule. If the contractor fails to maintain the desired power factor, and there is no any incentive for good power factor or any penality from MSEB due to low PF the same shall be borne by the contractor in addition Rs.10,000/- for each penalty/ non incentives. (d) The workers employed by the contractor will report to the concerned AGE/JE E/M every day. (e) The rate quoted by the contractor is deemed to be inclusive of the cost of dismantling/taking down however cost of Fixing of the items will be mesured and paid under relevant items of schedule. (f) The quoted rate deemed to be included the cleaning of ceiling/exahust/air circulator fan and APFC panels of any capacity. (g) Quoted rate is deemed to be inclusive all the safety equipment and other T & P required for carrying out the repairs / maintence. The contractor has to liase with the department in case of taking of electric shutdown of each machinery and has to make the machinery functional of the carrying out maintenance because maximum fans are installed at the height of more than 10 mtr. (h )Maximum fans are installed at the height of more than 10 mtr. Contracrors are adviced to inspect the site before quoting the rates.
Material and labour for removing of burnt winding of fans, cleaning of slots and rewinding of fans with super enamelled copper winding wire of suitable size, quality, quantity and providing with suitable insulation materials i.e varnish, sleeves, leathorised paper cotton tape etc to fan including replacement of worn out nuts, bolts, washers, split pin etc and testing complete all as specified and directed for the following type and size of fans :- NOTE :- Maximum fan are of old vintage.Contrators are adviced to inspect the fans before quoting the rates. (a) Ceiling fan 1200 mm sweep.
(b) Ceiling fan 1400 mm sweep.
(c) Exhaust fan single phase 250/280/300 mm sweep.
(d) Exhaust fan single phase 380/ 450 mm sweep.
(e) Exhaust fan single phase 600 mm sweep.
(f) Air circulator fan single phase 450 mm sweep.
(h) Air circulator fan single phase 600 mm sweep.
Supply only following components / parts of ceiling fans / exhaust fans / Air Circulators all as specified and as directed. (a) SKF bearings 6201 2Z or equivalent
(b) SKF bearings 6202 2Z or equivalent
(c) SKF bearings 6203 2Z or equivalent
(d) SKF bearings 6204 2Z or equivalent
(e) SKF bearings 6301 2Z or equivalent
(f) SKF bearings 6302 2Z or equivalent
(g) SKF bearings 6303 2Z or equivalent
(j) Terminal connector - Bakelite
(k) Bearing support plate
Supply only condenser / capacitor suitable for 440 volts single phase of capacity 2.5 Mfd, all as specified and as directed. MAKE :- Bajaj/Seimen/ Tibcon/Apco/Sagar
All as per Sl Item No. 19 here in before but for 3.15 Mfd.
All as per Sl Item No. 19 here in before but for 4.0 Mfd.
All as per Sl Item No. 19 here in before but for 6.0 Mfd.
All as per Sl Item No. 19 here in before but for 10.0 Mfd.
Supply only (brass) gun metal bush suitable for 1200 mm / 1400 mm sweep ceiling fan all as specified and As directed.
Supply only fan regulator, electronic eight step type, for 1200 mm /1400 mm sweep ceiling fan including necessary connection all as per Indo Asian (Shynora) or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Supply only top and bottom canopy of ceiling fan complete with tightening screws, set of two canopys all as specified and as directed.
Supply only fan blades suitable for any make of following sweep all as directed at site by Engr -in-charge. (a) Ceiling fan 1200 mm sweep.
(b) Ceiling fan 1400 mm sweep.
(c) Single phase exhaust fan 250/280/300 mm sweep.
(d) Single phase exhaust fan 380/450 mm sweep.
(e) Single phase exhaust fan 600 mm sweep.
(f) Single phase air circulator fan 450 mm sweep.
(g) Single phase air circulator fan 600 mm sweep.
Supply and fix ceiling fan down rod of 15 mm dia GI pipe medium grade with holes for nut, bolts, connectors, clamps etc for fixing ceiling fan duly screwed and painted to match the colour of andfor the following length pipe :- (a) 1.8 mtr length.
(b) 0.9 mtr length.
(c) 0.6 mtr length.
Supply only protection gaurd round shaped, made out with MS wires with suitable clamps, bolts and nuts etc complete suitable for old air circulators of Usha / AUE / Almonard make as existing at site for following sweep complete all as specified and directed. (a) Single phase air circulator fan 450 mm sweep.
(b) Single Phase Air Circulator Fan 600 mm Sweep
Supply only 1/12 HP fan motor suitable for 280/300 mm sweep exhaust fan of any Make and model or as per site requirement all as specified and as directed.
Supply only 1/2 HP fan motor suitable for 450 mm exhaust fan of any Make and model or as per site requirement all as specified and as directed.
Supply only 1/3 HP fan motor suitable for 600 mm exhaust fan of any Make and model or as per site requirement all as specified and as directed.
Supply only of mounting bracket of size 12"/300mm sweep including necessary clamps bolts and nut etc complete suitable for 1/35 HP exhaust fan motor as per existing shape /modle complete all as specified and as directed.
Supply only of mounting bracket of size 18"/450 mm sweep including necessary clamps bolts and nut etc complete suitable for 1/12 HP exhaust fan motor as per existing shape /modle complete all as specified and as directed.
Supply only of mounting bracket of size 24"/600 mm including necessary clamps bolts and nut etc complete suitable for 1/6 HP exhaust fan motor as per existing shape /modle complete all as specified and as directed.
Supply only fan motor 250 Watt capacity single phase 240 volts, 1400 RPM suitable for 600 mm sweep wall air circulator of Almonard Make any model or as per site requirement all as specified make Usha/AUE/Almonard
Supply only hot galvanised rigid steel conduit 20 mm dia, light grade at any height with and including all accessories like tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing, conduits etc. to walls,ceiling, steel joists etc. complete all as directed by Engr-in-Charge.
Material and labour for rolled mild steel as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolts, at any height, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint for mounting air circulator / exhaust fan / ceiling fan/ high bay lights etc for fixing arrangements complete all as specified and as directed.
Supply only sheet metal enclosures for TPN DBs (DPX 160 type ) for using MCCB as incommer suitable for triple pole and neutral, 8 way with having copper bus bars of suitable rating and MCBs as outgoing complete all as specified and as directed. MAKE :- Legrand Cat No. 5077 47 or techno commercially equivalent makes specified in PS.
Supply only sheet metal enclosures for TPN DBs (DPX 160 type ) for using MCCB as incommer suitable for triple pole and neutral, 4 way with having copper bus bars of suitable rating and MCBs as outgoing complete all as specified and as directed. MAKE :- Legrand Cat No. 5077 45 or techno commercially equivalent makes specified in PS.
Supply only sheet metal enclosures for SPN DBs for using MCBs / MCB isolators suitable for single pole and neutral, 8 way IP 43, IK 09 with double door complete all as specified and as directed. MAKE :- Legrand Cat No. 5076 11 or techno commercially equivalent makes specified in PS.
Supply only sheet metal enclosures for SPN DBs, DP enclosure for using MCBs / MCB isolators suitable for single pole and neutral, 4 way complete all as specified & directed. MAKE :- Legrand Cat No 5076 10 or techno commercially equivalent makes specified in PS.
Supply only dimmer controller 240 volts, 50 Hz, 400 Watts suitable for Air circulators all as specified and as directed. MAKE :- Anchor Cat No 38659 or techno commercially equivalent makes specified in PS.
Supply only switch 16 Amps, 240 Volts all as specified and as directed. MAKE :- Anchor penta or techno commercially equivalent makes specified in PS.
Supply only 1.6 mm thick 150x200 mm size with and including 3 mm thick hylum sheet suitable for mounting / fixing of two15 Amps piano type switch, one 5/15 Amps multi purpose socket and one 450 watt dimmer duly cutting, driling etc including fixing matarial complete all as specified and as directed. NOTE :- Maximun boxes are to be fixed on steel stucture by welding / driling of hoes etc., contractors are adviced to inspect the site before quoting the rates.
Supply only ceiling rose three terminals 240 Volt all as specified and as directed.
Supply only plug top 06 Amps, 3 Pin, 240 Volts, 50 Hz ISI Marked all as specified and as directed.
Supply only plug top 16 Amps, 3 Pin, 240 Volts, 50 Hz ISI Marked all as specified and as directed.
Supply only switch socket combined unit box type, two fixing holes, 240 volts, 50 Hz, 20 Amps & 10 Amps ISI Make all as specified and as directed. MAKE :- Anchor Code 39593 penta or techno commercially equivalent makes specified in PS.
Supply only of louver assembly of size 12"/300mm sweep exhaust fan made of steel or MS sheet complete as required at site all as specified and as directed.
Supply only of louver assembly of size 18"/450mm sweep exhaust fan made of steel or MS sheet complete as required at site all as specified and as directed.
Supply only automatic power factor control relay of 16 stage supply voltage - 415 volts, AC and current Input - 1A or 5 A all as per L&T Cat No CS90905OOOO or techno commercially equivalent makes specified in PS all as specified and as directed having following features:- (a). Intelligent control. (b). Self-optimizing control capability. (c). Automatic initialization. (d). Large voltage measuring range. (e). Powerful alarm output. (f). Large and multifunctional LCD with backlit display (2 x 16 characters). (g). Operating temperature : -20 to +60º C (h). Display and storage of maximum values, number of switching operations and operating time
Supply only capacitor 3 phase, super heavy duty rectangular box type as per existing, self standing units of modular construction with sheet metal enclosure, self healing property, including wire for use on 415V to 525V, 3 phase, 50 Hz, capacity 5KVAR, AC conforming to standards IEC 60831-1 2/96, IS 13340 with MPP film heavy edge of capacity including testing, commisioning as in repairs complete all as specified and as directed.
All as per Sl Item No. 62 above but 10 KVAR.
All as per Sl Item No. 62 above but 15 KVAR.
All as per Sl Item No. 62 above but 20 KVAR.
All as per Sl Item No. 62 above but 25 KVAR.
Supply only power capacitor duty contactor, 3 phase with auxilary switch block 415 volts suitable for 5 KVAR capacitor complete in various APFC panels all as specified and as directed.
All as per Sl Item No. 67 above but suitable for 10 KVAR capacitor
All as per Sl Item No. 67 above but suitable for 15 KVAR capacitor
All as per Sl Item No. 67 above but suitable for 20 KVAR capacitor
All as per Sl Item No. 67 above but suitable for 25 KVAR capacitor
Supply only side mounting add on aux contact 1 NO complete in various APFC panels all as specified and directed by Engr-in-Charge. MAKE :- L&T Cat No CS94120 or equivalent in C&S/HPL
Supply only side mounting add on aux contact 1 NC complete in various APFC panels all as specified and as directed by Engr-in-Charge. MAKE :- L&T Cat No CS94121 or equivalent in C&S/HPL
Supply only side mounting add on aux contact with 4 contact any combination of NO & NC complete in various APFC panels all as specified and directed by Engr-in-Charge. MAKE :- L&T Cat No CS94112 to 94115 or equivalent in C&S/HPL
Supply only 6 Amps control fuse link with base complete in various APFC panels all as specified and as directed by Engr-in-Charge.
Supply only 63 Amp control fuse link with base complete in various APFC panels all as specified and as directed by Engr-in-Charge.
Supply only add on aux control contactor 4 contact any combination of NO & NC complete in various APFC panels all as specified and directed by Engr-in-Charge. MAKE :- L&T Cat No CS91623 to 91625 or equivalent in C&S/HPL
Supply only ON delay timer 12-120 sec all as per L&T Cat No. ST80329OOOO or equivalent in C&S complete in various APFC panels all as specified and as directed by Engr-in-Charge.
Supply only emergency stop button complete in various APFC panels all as specified and as directed by Engr-in-Charge.
Supply only 1.1 KV tape insulated indoor current transformer of ratio 250/5 to 600/5 Amps and rated burden of 15 VA complete in various APFC panels all as specified and as directed by Engr-in-Charge. MAKE :- AE or equivalent.
All as per Sl Item No 80 above but ratio 800 to1200/5 Amps.
Supply only 1.5 sq.mm multistranded copper FR wire for control circuit gray in colour complete in various APFC panels all as specified and directed by Engr-in-Charge.
Supply only 6 sq.mm multistranded FRLSH copper flexible cable for capacitor connections complete in various APFC panels all as specified and as directed by Engr-in-Charge.
All as per Sl Item No. 83 above but 10 sq.mm.
All as per Sl Item No. 83 above but 16 sq.mm
All as per Sl Item No. 83 above but 35 sq.mm
All as per Sl Item No. 83 above but 50 sq.mm
All as per Sl Item No. 83 above but 70 sq.mm
Supply only 6-32 Amps SP MCB, 10 KA 'C' series, 240 Volts AC, 50 Hz complete all as specified and as directed by Engr-in-Charge.
All as per Sl Item No. 89 above but 6-32 Amps SPN.
All as per Sl Item No. 89 above but 6-32 AmpsTP
All as per Sl Item No. 89 above but 40 Amps TP.
All as per Sl Item No. 89 above but 63 Amps TP.
Supply only 2 way slector adaptor switch complete in various APFC panels all as specified and as directed by Engr-in-Charge.
Supply only plastic body instrument cooling axial fan of 120 x 120 x 38 mm size fitted complete within the panel including cutting of a suitable sized hole on the panel body and wiring with 1.5 sq.mm copper conductor cable and MCB SPN 6 Amps complete including disconnecting and dismantling the old one as per satisfaction of Engr-in-Charge.
Taking down existing unserviceable aluminum / copper point wiring of any description and in any position including all fittings and making good the disturbed surface to match with the existing surfaces complete all as specified and directed.
Material and labour for point wiring in PVC conduit of suitable size but not less than 20mm dia including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sq.mm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sq.mm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and including PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
All as per Sl Item No 99 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Sl Item No 99 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Sl Item No 99 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amps on independent board using 2.5 sq.mm two runs and one run 2.5 sq.mm (nominal area) stranded copper conductor cable.
Material and labour for point wiring in casing and caping of suitable size but not less than 20mm size including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sq.mm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sq.mm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and including PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
All as per Sl Item No 103 above but one bell/buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm size.
All as per Sl Item No 103 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Sl Item No 103 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Sl Item No 103 above but point wiring for one five pin socket outlet, 15 Amps and 5 Amps on independent board using 2.5 sq.mm two run and one run 2.5 sq.mm (nominal area) stranded copper conductor cable.
Supply and fix switch flush type, 5 Amps, single pole, one way, 230 volts AC circuit complete all as specified and as directed.
Supply and fix bell push, flush type, 5 Amps, 230 volts AC circuit complete all as specified and as directed.
Supply and fix socket outlet, five pin, 5 Amps, flush type, multi purpose, 230 volts AC circuit complete all as specified and as directed.
Supply and fix switch flush type, 15 Amps, single pole, one way , 230 volts AC circuit complete all as specified and as directed.
Supply and fix socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type 230 volts AC circuit complete all as specified and as directed.
Supply and fix ceiling rose, PVC/polycarbonate, isolated body, three terminals, complete all as specified and as directed.
Supply and fix in replacement eight stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50Hz supply, 100Watt complete all as specified and as directed. MAKE :- Indo Asian (Shynora) or Equivalent.
Dismantling and taking down unserviceable light fitting of any type from any location / height after disconnecting of electrical connections complete including all connected accessories all as directed.
Supply and fix LED tube light fitting suitable for and including 1x20 Watt 4 feet long tube with polycarbonate diffuser complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. MAKE :- Crompton Greaves Cat part No. Bright Linea CCS-100-20-65-HL2-DP-NWH or techno commercially equivalent makes specified in PS.
Supply and fix 36 Watt 2' X 2' LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size and all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. MAKE :- Crompton Greaves Cat Part No. Polaris Nio-I LCTLRNE-36-FO-CDL or or techno commercially equivalent makes specified in PS.
Supply and fix 36 Watt 2' x 2' LED surface mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size and all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. MAKE :- Crompton Greaves Cat Part no-Polaris Nio-III LCTLSNE-36-FO-CDL or or techno commercially equivalent makes specified in PS.
Supply and fix ceiling fan of 1200 mm sweep 3 star rating including provision of cable from ceiling rose or connector to fan,anchor bolt for fixing of ceiling fan,ceiling fan rod at any height Complete all as specified & directed by Eng-in charge. Make: Bajaj Cat part No. Sabse Tez EE03 251119 or or techno commercially equivalent makes specified in PS.
Supply and fix exhaust fan (metal body), AC, single phase, 230/240 volts of size 250 mm sweep with louvers and provision of flexible copper cord from ceiling rose to fan including making hole in wall without disturbing the good surfaces complete all as specified and as directed by Eng-in charge. MAKE :- Bajaj Cat part No: Bahar 70000 or techno commercially equivalent makes specified in PS.
Supply and fix wall mounted fan 400mm sweep 230 volts, AC, SP oscilating swing type with all acceessories and fixing arrengements complete all as specified and as directed. MAKE :- Bajaj Cat part No.Neo spectrum Grey 250890 or techno commercially equivalent makes specified in PS.
Supply only MCCB, FP 25 KA, 63Amps with thermal magnetic release, Ics = 100% Icu, adjustable over load setting: 0.8 -1.0 x In, adjustable short circuit for each phase from 5 - 10 x Ir including supply only of spreader terminals, disconnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand Cat No. 420073 or techno commercially equivalent makes specified in PS.
Supply only MCCB TP, 25KA, 100 Amps with thermal magnetic release, Ics = 100% Icu, adjustable over load setting: 0.8 -1.0 x In, adjustable short circuit for each phase from 5 - 10 x Ir including supply only of spreader terminals, disconnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand Cat No. 420075 or techno commercially equivalent makes specified in PS.
Supply only MCCB TP, 25KA, 160 Amps with thermal magnetic release, Ics = 100% Icu, adjustable over load setting: 0.8 -1.0 x In, adjustable short circuit for each phase from 5 - 10 x Ir including supply only of spreader terminals, disconnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand Cat No. 420057 or techno commercially equivalent makes specified in PS.
Supply only MCCB TP, 25KA, 200 Amps with thermal magnetic release, Ics = 100% Icu, adjustable over load setting: 0.8 -1.0 x In, adjustable short circuit for each phase from 5 - 10 x Ir including supply only of spreader Terminals, disconnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand Cat No. 420218 or techno commercially equivalent makes specified in PS.
Supply only MCCB TP, 25KA, 250 Amps with thermal magnetic release, Ics = 100% Icu, adjustable over load setting: 0.8 -1.0 x In, adjustable short circuit for each phase from 5 - 10 x Ir including supply only of spreader terminals, disconnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand Cat No. 420219 or techno commercially equivalent makes specified in PS.
Supply only MCCB TP, 36KA, 400 Amps with thermal magnetic release, Ics = 100% Icu, adjustable over load setting: 0.8 -1.0 x In, adjustable short circuit for each phase from 5 - 10 x Ir including supply only of spreader terminals, disconnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand Cat No. 422007 or techno commercially equivalent makes specified in PS.
metro electrical services
ASHWAMEDH ENGINEERS
AJ. Owners
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .