RequiredExperience with Government
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate Bid to RA enabled Yes Surgical Operating ENT Microscope ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Conformity to Certification US FDA US FDA
RequiredEuropean CE
RequiredBIS Certification number and date - * Confirmity to Manufactures Certification ISO 9001 & ISO 13485 ISO 9001 & ISO 13485 Confirmity to electrical safety Standards IEC 60601-1 or BIS equivalent * 1/6 Performance Parameters Purpose Surgical Operating ENT Microscope with heavy sturdy floor stand with H base design with 4 easily ground cleared movable castors * Zooming Ratio 1:06 * Magnification (5 Step) 2.5 X 2.5 X Manually adjustable magnification changer 1.6 X
Required2.0 X
Required2.5 X 1.6 X
Required2.0 X
Required2.5 X Type of Camera 1 CCD Video Camera * Resolution of camera in pixels 1920 x 1080 px 1920 x 1080 px Wide field push in eye pieces 10 X 10 X Provision of integrated eye cups Yes Yes Type of Binocular tube Straight Straight
RequiredTilt
RequiredInclinable 45 degree viewing
RequiredInclinable 60 degree viewing
Required0 degree to 240 degree Inclinable Beam splitter with co- observation tube Yes * Provision of built in IR Filter Yes Yes Provision of built in UR Filter Yes Yes Adjustable friction of all joints Yes Yes Provision of integerated handles for positioning of microscope Yes Yes Swivel angle of carrier arm in degrees 300 * Movements of Microscope Moved to & fro
Requiredup & down
Requiredand side to side * Provision of knob for manually adjusting interpupillary distance Yes * Microscope should be mounted on a mobile floor with locking facility Yes * 2/6 Maximum height of Microscope in meters 1.35 or less * Focal length of Binocular tube in mm 300 mm 170 mm
Required200 mm
Required300 mm
Required400 mm Provision of sterilizable rubber caps for control knobs Yes * Camera system Separate camera through beam splitter mounted and monitor * Type of monitor (medical grade) LED LED Monitor resolution 1920 x 1080 px 1920 x 1080 px Size of monitor screen in inch 21 17
Required21
Required27 Availability of CCD digital camera attachment Yes Yes Facility of video recording facility with video trolley with isolating transformer No Yes (capacity 1 TB with 4.5 inch or more touch screen)
RequiredYes (capacity 500 GB with 4.5 inch or more touch screen)
RequiredNo Availability of dust cover for microscope Yes Yes Dimensional Parameters Objective lens in mm 250 mm
Required300 mm 250 mm
Required300 mm Field of view in mm 52 mm to 8 mm 52 mm to 8 mm Fine Focusing range (manual) in mm 13 * Arm length in mm Not less than 1000 mm on maximum stretching * Weight of the Microscope in kg 110 * Illumination LED (with no backup) LED (with no backup) Power Requirements Power Supply 220-240 Volt/50 HZ Single Phase * Light source LED LED Facility of stand for bulb change No Yes
RequiredNo Power Back Up Provided Not provided Online UPS System
Required2 KVA
RequiredNot provided Back up time NA if back up not provided 15 Minutes
RequiredNA if back up not provided Facility of spike protection for 30 No Yes
RequiredNo 3/6 minutes Additional Parameters On screen display to be provided Yes Yes
RequiredNo ON Screen display showing total magnification
Requiredscale projection
Requiredworking distance etc NA if no screen display is provided Yes
RequiredNA if no screen display is provided All the cables should be inside the stand for protection Yes * Microscope should have excellent design quality Yes * Warranty in Years 5 5 Reports Number of installations in Central/State/PSU Govt Hospitals >3 <3
Required>3 OEM/Reseller ( if supplied by reseller shall ensure uninterrupted availability of all spares for 10 years) Yes * Availability of toll free facility for technical support maintened by OEM or authorized agencies Yes * During the warranty period it shall be ensured that all the break down calls are attended with in 24 hrs and the complete details of service agents/contact details should be furnished to buyer and consignee at time of supplies Yes * User/Technical/Mainten ance manuals to be supplied in English in hard and soft copy Yes * Details of equipments and procedures required for local calibration and routine maintenance to be supplied and advanced maintenance task Yes * 4/6 documentation also to be furnished List of important spares and accessories
Requiredwith their part numbers to be supplied to the buyer at the time of supplying the equipment Yes * Demonstration of equipment and training to be provided after completing supplies before acceptance Yes * The Principal Manufacturer must have direct Presence/approved service center In India Yes * Copies of reports and certifications to be furnished to buyer on demand at time of supplies Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.