Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹14.1 L+₹50,874 (3.73%)Rejected-Finance 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-Finance BEING L1 | |
| 3 | Rejected-Technical 18TH FLOOR FL NO 1801 PANCHASHEEL HEIGHT MAHAVEER NAGAR KANDIVALI WEST MUMBAI 400067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | Rejected-Technical Ref to WLR of CESC Pune QE SEP 2024 due to Slow Progress and NO remarks vide Srl No 48.00 of Part-II |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
17 Dec 2024, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
PROVN OF SCREENING WALL IN DOMESTIC AREA, PROVISION OF AREA DRAINAGE AND FALSE CEILING WITH ADEQUATE LIGHTING IN CERTAIN LOCATIONS AT AFS MADH ISLAND UNDER GE AF THANE
2024_MES_684877_1
8405/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹30,000
Yes
13 Mar 2025
21 Nov 2024
24 Dec 2024
21 Nov 2024
17 Dec 2024
5 Dec 2024
Amount
M&L for Excavating over areas in soft / loose soil , n exc 1.5 m deep and getting out , complete all as specified.
M&L for Excavating over areas in hard / dense soil , n exc 1.5 m deep and getting out , complete all as specified.
M&L for Excavating over areas in soft/ disintegrated rock , n exc 1.5 m deep and getting out , complete all as specified.
M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundational filling, mass concrete of area drain all as specified and directed.
M&L for Precast cement concrete with PCC (1:3:6) as using 20mm graded stone aggregate in block masonry with solid blocks exc 10cm in width and setting in CM (1:6) all as specified and as directed.
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping including necessary form work and finishes the surfaces even without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick cement plaster over PCC block Masonary surface in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and as directed.
Extra for fair finished drain or channel 30cm inner girth in cement concrete using extra cement including form moulds mitrd/stopped ends etc all as directed.
S&F Reinforced concrete pipes of 450mm bore, class NP3, laid and jointed complete with collars, complete all as specified.
M&L for Concrete bed to 450mm drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested, in cement concrete 1:3:6 type C-2, complete all as specified.
M&L for hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface completed all as specified and directed.
M&L for 100mm thick cement concrete type B1 (1:2:4) by using 20mm graded stone aggregate as in paving and finishing concrete surface even and smooth without using extra cement, complete all as specified.
M&L for flat rough finished Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips completed all as specified and directed.
M&L for reinforced cement concrete type B1 (1:2:4) (nominal mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like completed all as specified and directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified.
M&L for Preparation of new steel surafces of any description & apply two coats of synthetic enemal paint over a coat of red oxide, complete all as specified.
Returning, filling in soft/loose soil, hard/dense soil including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified.
Removing excavated material outside the MD land exc 1.5km but not exc 5 km and depositing where directed as per local/ munciple corporations rules/directions , complete all as specified.
Supply and fix false ceiling with powder coated exposed GI grip suspension system (E-grip T-2430 of equivalent load carrying capacity with mid span deffection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross tee 1200mm/600mm long wall angle. The main runners to be placed @ 1200mm, the cross tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm from a modular grid of 1200mm X 600mm. Additional cross less of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally from a grip of 600mm X 600mm. Grip of modular size 600mm X 600mm shall be supported by 6mm dia GI wire from purlins/soffit with and including 6mm thick high pressure steam cured non asbestos fiber and fixed complete all as specified and as directed. Make : Armstrong or Equivalent
S&F for ceiling boards 600x600x15mm in size, fixed in snap grid false ceiling frame work of approved colour, type complete fixed in position all as specified and directed. Make : Armstrong Optra RH95/ FG Classic or Equivalent
Surface dressing in soft/ loose soil n.exc 15 cm deep, complete all as specified
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting ouf, returning, filing in and rarnming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in sof/disintegrated rock, complete all as specified.
M&L for Cement concrete type B-1(1:2:4) in foundations, filling and mass concrete, complete all as specified.
S&F Hand rails, for doors, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron filets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, elc., and similar work conforming to Fe-290 Gde E-165 complete all as specified.
S&F Rolled secions as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. confirming to Fe-290 (Gde-E-165), complete all as specified.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete ll as specified
M&L for flat formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.i vertical or to batter, complete all as specified
Dismantling posts or struts (wood, steel or R.C.C.) embeded in concrete any section, including taking out embedded portion and making good disturbed ground, complete all as specified.
Dismantling fencing wire mesh, any type, complete all as specified
M & L for point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC casing & caping , hooks , elbows, juction covers and junction boxes , after cutting in wall and sinking's for modular metal flush boxes suitable length and Min 1.6 mm thickness, Min 51 mm depth for mounting, switches, sockets,fan regulator with modular cover plate with frame and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and directed.
S & F modular socket 2/3 pin, type 5/6 Amps 5 in 1 flush type including modular cover plate and metal flush box with frame complete all as specified and directed.
S & F modular switch 5/6 Amps single pole one way,one module including modular cover plate with frame and metal flush box complete all as specified and directed.
Supply and Fixing LED luminaire 600mm x 600mm, 35/36 watt, 220AC recessed type with high efficiency PMMA diffuser soft glare free light complete with deiver, holder & LED lamp suitable for roof ceiling including connection up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S & F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 4 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof, IP 42 suitable for incorporation MCBs and isolators etc including making good disturbed surfaces of walls as necessary complete all as specified and directed.
S&F MCB ‘B’ series type suitable for 240 volts, AC supply 6 to 32 Amps, SP&N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S&F MCB ‘B’ series type suitable for 240 volts,10 KA, AC supply 6 to 32 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S & F for Sub Main wiring with two single core 6 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing caping conduit with and including PVC insulated 6 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed. Note :- Two length of 6 Sqmm cable and one length of 6 Sqmm earth cable along with PVC casing caping will be measured as one running length
Vishal Builders (BID ID -3185287)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .