Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹47.7 LAdmitted-Finance REWARI HARYANA 123501 INDIA UDYAM HR 15 0008586 | REWARI | HARYANA | 123501 | -18.60% | ₹47.7 L | L1 | Admitted-Finance |
| 2 | L2₹50.6 LAdmitted-Finance PLOT NO 733 SPRINGVILLA GREEN HOUSE NO 2 BIJIPUR TAMANDO BHUBANESWAR 752054 | KHORDHA | ODISHA | 752054 | -10.52% | ₹50.6 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | - | Rejected-Technical Technically Not Acceptable |
| 4 | Rejected-Technical BHILAI | - | - | - | Rejected-Technical Technically Not Acceptable |
Tender Value
₹54.4 L
EMD Value
₹14,000
Closing Date
18 Feb 2026, 4:00 pmClosed
DGM T
Indian Oil Corporation Limited Pipelines Division South Eastern Region Pipelines E3 4th Floor, Infinia Tower, Infocity Area Bhubaneswar Odisha 751024
Annual Rate Contract for Upkeep, Maintenance, Yearly Testing and Calibration of Electrical Facilities (including 33/6.9 kV Outdoor Switchyard) at SERPL Bhubaneswar PS, for a period of 02 Years
2026_ERBBS_188757_1
9320C26A12
Open Tender
Electrical Works
730 days
Jatni Bhubaneswar
Please refer Tender documents.
6 documents required · 6 mandatory
₹14,000
Yes
1 Apr 2026
4 Feb 2026
19 Feb 2026
4 Feb 2026
18 Feb 2026
4 Feb 2026
VARIABLE-Yearly Maint, Testing & Oil Fil
Preventive Maintenance visits for various HT equipment and HT Panels(VCB) in 33kV Switch Yard, 33kV Substation and HT/LT Room at SERPL Bhubaneswar Pump Station as per Scope of Work
Testing & Calibration of Transformer Oil, Numerical & Electromechnical Relays, Panel Meters and Measuring Instruments at SERPL Bhubaneswar Pump Station as per Scope of Work
FILTRATION OF TRANSFORMER OIL Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength as per specification given below and as per Scope of Work (excluding the supply of oil). a) Filtration of transformer oil till desired bdv is attained as per is. b) Topping up of oil. c) Releasing all the air from air release plug & bucholz relay. d) To and fro transportation of filter machine and equipments.
Supply of new Transformer Oil (As per IS:335:2017) of reputed make as per direction of EIC.
VARIABLE - General
Supervision Charges on Fixed Portion. The quantity of this item shall be considered as landed monthly fixed amount.
PPE and Uniform (Quantity <H>Each</> implies Personal Protective Equipment (1 Set of Safety Shoes & Safety Helmet), 2 sets of Inherent Flame-Retardant Suit and 12 sets of Hand Gloves)
Light fittings: Industrial LED Flood Light/High Mast Fixture, Rating: 350W
Light fittings: 2 feet x2 feet with all fitting/fixtures as per technical specification- nominal 36W
Rewinding and Overhauling of 1-ph AC / 3-ph AC / DC Electrical Motors: Motors Upto and including 5 kW
Rewinding and Overhauling of 1-ph AC / 3-ph AC / DC Electrical Motors: Motors Above 10 kW and upto and including 20 kW
Overhauling of 1-ph AC / 3-ph AC / DC Electrical Motors of Voltage Grades up to 500V (AC/DC) and of ALL Makes/Types and of following capacities. Job includes a. Varnishing with Minimum 'F' Class ISI Marked Motor Varnishb. Stator baking to required temperaturec. Sl eeving with sleeves on connection wires d. Repair/Replacement of new terminal plate, studs, bushings. etc.wherever necessary e. Repl acement of bearings (DE & NDE), Oil Seals and Greasing of Bearing f. Frame Painting using Red Oxide Primer (01 Coat) and Synthetic E namel Paint (02 Coats)g Motor disconnection, removal, to and from transportation of motor between site and overhauling workshop, re- installation, re-connection,testing, handing over i. All other activities required for overhauling of the motor All Materials, Labor , Tools, Equipment required for this item is in thescope of CONTRACTOR" : Motors Upto and including 5 kW
Overhauling of 1-ph AC / 3-ph AC / DC Electrical Motors of Voltage Grades up to 500V (AC/DC) and of ALL Makes/Types and of following capacities. Job includes a. Varnishing with Minimum 'F' Class ISI Marked Motor Varnishb. Stator baking to required temperaturec. Sl eeving with sleeves on connection wires d. Repair/Replacement of new terminal plate, studs, bushings. etc.wherever necessary e. Repl acement of bearings (DE & NDE), Oil Seals and Greasing of Bearing f. Frame Painting using Red Oxide Primer (01 Coat) and Synthetic E namel Paint (02 Coats)g Motor disconnection, removal, to and from transportation of motor between site and overhauling workshop, re- installation, re-connection,testing, handing over i. All other activities required for overhauling of the motor All Materials, Labor , Tools, Equipment required for this item is in thescope of CONTRACTOR" : Motors Above 10 kW and upto and including 20 kW
TP&N Switch: Upto and including 63 Amps
MCCBs: 4P MCCB, SCBC upto 36 kA, Upto and including 200 Amps
HRC Fuse-HRC Fuse up to and including 16 Amps
HRC Fuse: HRC Fuse above 16 Amps and upto and including 80 Amps
HRC Fuse: HRC Fuse above 80 Amps and upto and including 160 Amps
HRC Fuse Base: HRC Fuse Base and Carrier up to and including 16 Amps
HRC Fuse Base: HRC Fuse Base and Carrier above 16 Amps and upto and including 80 Amps
HRC Fuse Base: HRC Fuse Base and Carrier above 80 Amps and upto and including 160 Amps
LED indicating lamps: Red / Green / White / Amber Color
LED indicating lamps: Yellow Color
LED indicating lamps: Blue Color
CABLES
Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvani AL,3.5CX150 mm²,A2XFY
Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvani AL,3.5CX240 mm²,A2XFY
Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized CU,3CX4 mm²,2XWY
Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized CU,2CX2.5 mm²,2XWY
Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized CU,3CX2.5 mm²,2XWY
Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized CU,2CX4 mm²,2XWY
Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized CU,2CX10 mm²,2XWY
HT 66kV, 33 KV, 11 KV & 6.6 KV cables. Screened, XLPE insulated, extruded PVC type ST-2 inner sheat AL 3CX400 mm² 6.6KV
HT 66kV, 33 KV, 11 KV & 6.6 KV cables. Screened, XLPE insulated, extruded PVC type ST-2 inner sheat AL 3CX240 mm² 6.6 KV
LIGHTNING ARRESTOR : Supply of lightning arrestors with insulating base fittings etc. as per specifications For 30 kV rated voltage (Highest system voltage 36 KV) , 10 KA lightening arrestors
Supply of discharge rod with earthing arrangement suitable for 33 KV voltage level
AIR CONDITIONING WORKS
Annual Maintenance Contract of Split Air Conditioners of capcity upto 2 tonne. The job includes: 1. Quarterly routine service of the unit i.e., a) Quarterly Inspection and Maintenance of AC Units b) Cleaning of Filter, Coils and other essential components c) Checking and topping up of refrigerant levels R-32/R-410A/R-22 2. Overhauling of the unit once in a year for better performance of the unit. 3. To Repair or to replace electrical controls of the machines such as relay, overload protectors, capacitors, thermostat, refrigera nt gas, motors are covered under AMC. 4. Attending break down calls free of charge during our normal working hour. 5. Arranging the required spare parts which are not covered above to make the unit operational. Payment shall be made elsewhere in S oR upon proof of submission of original bills from the OEM for the respective spare.
Annual Maintenance Contract of Cassette Air Conditioners of capcity upto 2 tonne. The job includes: 1. Quarterly routine service of the unit i.e., a) Quarterly Inspection and Maintenance of AC Units b) Cleaning of Filter, Coils and other essential components c) Checking and topping up of refrigerant levels R-32/R-410A/R-22 2. Overhauling of the unit once in a year for better performance of the unit. 3. To Repair or to replace electrical controls of the machines such as relay, overload protectors, capacitors, thermostat, refrigera nt gas, motors are covered under AMC. 4. Attending break down calls free of charge during our normal working hour. 5. Arranging the required spare parts which are not covered above to make the unit operational. Payment shall be made elsewhere in S oR upon proof of submission of original bills from the OEM for the respective spare.
Dismantling & shifting of Split Air Conditioning Unit 1.0TR / 1.5TR / 2.0TR capacity including indoor and outdoor unit, refrigerant tubing etc. complete to new location or A/C workshop as per direction of Engineer-in-charge.
Installation of split type wall Mounted Air Conditioner indoor, outdoor unit fitted with rotary compressor, copper condenser and fir st charge refrigerant R410A/R22/Other, including connection of copper pipe and material supplied with complete unit etc. as required (Excluding cost of copper pipe) within Station premises as per direction of Engineer-in-charge.
ADDITIONAL COPPER TUBE FOR SPLIT AC Supply & fixing of additional length of copper tube for split A/C commissioning including all ac cessories.
GAS CHARGING OF AIR CONDITIONER UPTO Gas charging of air conditioner upto 1.5ton capacity with job involved transportation of machin e to vendors' works. Checking of all components for leak by charging co2 gas & finally evacuating the compressor completely & charge s of refrigerant gas - 22. A
Providing salt and charcoal for pipe earth electrode as required.
64 kg charcoal and 5 kg salt
160 kg coke and 5 kg salt
Supply, fixing and connection of 250 V flush type / tumbler Anchor make or approved equivalent switch, socket bell push etc. on perp ex sheet on MS box inlcuding supply and fixing of nuts, bolts, etc. but excluding the perpex sheet all complete with labour and mate rials as per direction of the Engineer-in-Charge.
3 pins 5 / 6 amps. Penta flush socket outlet
3 pins flush type 15 / 16 amps. socket outlet
Supply, fixing and connection of 250 V below given mosaic modular wiring accessories of M/s Supply, fixing and connection of 250 V b elow given mosaic modular wiring accessories of M/s MDS or approved equivalent inlcuding supplying and fixing of nuts, bolts, etc. c omplete with labour
6 amps. - 1 way - SP - 1 module switches
6 amps. - 2 way - SP - 1 module switches
10 amps. - 1 way - SP - 2 module switches
6 amps. - 2 / 3 pins combined 2 module shutterred socket
16 amps. - 3 pins - 3 module switch socket
Supply and fixing of below given white cover plate with frame for mosaic wiring accessories of M/s MDS or approved equivalent inlcud ing supply and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
6 module
12 module (6 x 2)
Supply, installation, testing & commissioning of following Ex-e/ weather proof junction boxes of F Supply, installation, testing & c ommissioning of following Ex-e/ weather proof junction boxes of FCG/Baliga make, suitable for lighting distribution including supply of steel structure, Elemax termi
300 x 300 x 125 with IP 66 protection
Supply, fixing in position, installation, connection, testing and commissioning of the following LE Supply, fixing in position, inst allation, connection, testing and commissioning of the following LED Light Fittings rated for 240V, 50Hz, 1-ph AC fo the make of Phi lips/Osram/Havells/Wipro/Bajaj/Ever
FLAMEPROOF LED FLOOD LIGHT FITTING 45 W, Supply, installation, testing & commissioning of Ex'd' (Flameproof) Flood Light Fixture wit h provision of Cable Entries: 2 Nos. x 3/4" ET, Cable Glands: 2 Nos. x 3/4" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), Double Compression t ype, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), and as per attached detailed technical specification.
FLAMEPROOF LED FLOOD LIGHT FITTING 90 W, Supply, installation, testing & commissioning of Ex'd' (Flameproof) Flood Light Fixture wit h provision of Cable Entries: 2 Nos. x 3/4" ET, Cable Glands: 2 Nos. x 3/4" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), Double Compression t ype, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), and as per attached detailed technical specification.
FLAMEPROOF LED WELL GLASS FITTING 125 W, Supply, installation, testing & commissioning of Ex'd' (Flameproof) Well Glass Light Fixtur e with provision of Cable Entries: 2 Nos. x 3/4" ET, Cable Glands: 2 Nos. x 3/4" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), Double Compress ion type, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware : SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), and as per attached detailed technical specification.
Supply, fixing and connection of Philips/approved equivalent make LED Slim Panel Round /Square suit Supply, fixing and connection of Philips/approved equivalent make LED Slim Panel Round /Square suitable for Recessed / Surface mounting made of diecast alluminium b ody with powder coating, ac
HARD STONE LAYING (SW YARD) Providing and spreading 40mm size approved hard stone chips around transformer yard in one layer of 100m m thick. job includes dressing of soil surface and laying the aggregate in uniform laying and density as per direction of site engin eer aggregate shall be measured in boxes of size 1.1/2m x 1.1/2m x 1.1/2m which shall be taken as 1CUM. the boxes will be supplied b y contractor free of charge for measuring purpose.
Supply of 40mm size stone chips per CUM.
Spreading the stone chips per CUM
Removal of rubbish/debris/brickbats, laterite boulders, earth, plaster flakes etc. including carriage by mechanical transport includ ing packing stacking the rubbish in regular stacks at loading points at different places before loading the same in the trucks and u nloading the same at directed places upto a lead of 2 KM, including local carriage of rubbish at loading and unloading point etc. co mplete as per direction of the Engineer-in-charge. (Payment will be made by stack measurement after deducting 20% for voids from sta ck measurement).
Cleaning of surface, rust removing of foreign matter, rubbing down thoroughly with emery paper, wire brush, washing with degreasing solvent (white spirit) to remove grease etc. and preparation of surface for application of enamel paint by spray painting on bus duc ts, transformers/motors/ or any other metallic surface with one coat of ready mixed primer and two coats of Approved quality/APCOLIT E ASIAN synthetic enamel paint including supply of paint suitable for a temperature of 100 Degree Celsius. All complete with labour and materials as per directions of the Engineer-in- Charge.
PAINTING OF ELECTRICAL EQUIPMENTS: Cleaning of surface, rust removing of foreign matter, rubbing down thoroughly with emery paper, w ire brush, washing with degreasing solvent (white spirit) to remove grease etc. and preparation of surface for application of paint by spray painting on electrical equipment/ structures/ poles or any other metallic surface with two coats of approved brand and manu facturer Aluminium paint including supply of paint suitable for a temperature of 100 Degree Celsius. All complete with labour and ma terials as per directions of the EIC.
Lettering with black Japan paint of approved brand and manufacture including supply of all material & labour and transportation etc Note : Unit of measurement is considered EACH which is equal to per cm height per letter.
Supply of accessories for transformers
Supply & replacement of OTI as per direction of Engineer-in- Charge.
Supply & replacement of Buchholz relay as per direction of Engineer-in-Charge.
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1000gm silicagel as per direction of Engineer-in-C harge.
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1500gm silicagel as per direction of Engineer-in-C harge.
Supply & Replacement of silica gel in transformers as per direction of Engineer-in-Charge.
SAFETY EQUIPMENT - Supply and installation of 11/6.6 KV Discharge Rod
INSULATING MATS - Supply & installation of 2000 mm X 1000 mm and of thickness as mentioned below, approved quality insulating Elasto mer mats as per specifications: Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2 mm (Class A)
INSULATING MATS - Supply & installation of 2000 mm X 1000 mm and of thickness as mentioned below, approved quality insulating Elasto mer mats as per specifications: Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2.5 mm (Class B)
SAFETY EQUIPMENT - Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges: Supply of fully charged CO2 fire extinguishers as per specifications (4.5 kg capacity as per IS: 28
CABLE TRENCH: Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres includi ng shoring, strutting etc. (if necessary), backfilling the trench, job complete in all respects, including all labour and materials complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
WBM ROAD / CONCRETE BREAKING: WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road/dyke to original condition and disposing off excess materials (within the work site) job complete in all respects including the cost of labour, tools, materials, load, lift hire charges of equipments, if any, complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable r acks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and install ation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the co nduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tool s, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engin eer / Engineer-in-Charge:
Power cables LT : OD upto 20 mm
Power cables LT : OD above 20 mm and upto 40 mm
Power cables LT : OD above 40 mm and upto 60 mm
Power cables LT : OD above 60 mm
Power Control cables LT : OD upto 20 mm
Power cables HT
GI CABLE TRAY: Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, con sumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
SAND FILLING: Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, load and lift charges, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
BRICK SOLING: Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable trenches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles etc , a s per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
CABLE MARKER: Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concret e grouting, backfilling, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Si te Engineer / Engineer-in-Charge.
HT CABLE JOINT: Making straight-through joint on 6.6 / 11 KV Aluminium/Copper XLPE/PVC insulated armoured screened cable, including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem / M-seal / 3M), materials, la bour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge: For cables of size upto 3 core x 400 sqmm
LT Cable joint (1.1 KV) - Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply o f required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge:
Power cables LT : OD upto 20 mm
Power cables LT : OD above 20 mm and upto 40 mm
Power cables LT : OD above 40 mm and upto 60 mm
Power cables LT : OD above 60 mm
HT Cable of size above 3Cx240 sq. mm
HT Cable of size upto 3Cx240 sq. mm
EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earth ing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing elect rodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-char ge, including the cost of all labour, tools, materials, etc. complete in all respect:
50 mm X 6 mm G.I. earthing strip
40 mm X 5 mm G.I. earthing strip
25mm x 4 mm copper flat
25mm x 3 mm copper flat
GI wire (8 SWG)
GI wire / rope 35 sq. mm
GI wire / rope 10 mm diameter
Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (a lready made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of sit e engineer / Engineer-in-Charge:
Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (a lready made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of sit e engineer / Engineer-in-Charge: 150 mm
STEEL STRUCTURAL WORKS Supply, fabrication, erection, installation of steel structural works of any type and shape such as cable rak s, cable trays, push button control posts etc., as required job complete in all respects including the cost of all labour, tools, ma terial etc., complete.and as per specifications and directions of site engineer/ Engineer-in-Charge.
FLP/WP EXHAUST FANS: Flame proof, weather proof, single phase, 12" exhaust fan, IP65, LM6 type EF1001 of FCG or equivalent alongwith supporting frame, bolts, louvers, flame proof motor, including supply & installation of double compression cable glands & flame pro of plugs for sealing all spare entries, complete in all respects
FLP/WP ROTARY SWITCH: Supply, installation, testing & commissioning of Flame proof weather proof ON/OFF Rotary Switch , IP65, LM6, i ncluding including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc., complete in all respects.
FLP/WP SWITCH CUM SOCKET - Supply, erection, installation, testing and commissioning of flameproof /weatherproof switch cum socket / welding receptacle of approved makes to be installed on walls, coloumns, structures, including supply & installation of double compr ession cable glands & flame proof plugs for sealing all spare entries etc., including connection and termination of earthing wire an d conduits., etc. complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, too ls, consumable materials etc. complete in all respect: 250V, 63 A Plug & welding receptacle
SHOCK TREATMENT CHART: Supply and installation of shock treatment chart framed in good quality glass in English / Hindi / Local Lang uage.
CAUTION BOARD: Supply and installation of vitreous enamel caution boards suitable for 440 V/11KV/6.6 KV as per IS
Point wiring - Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade including earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installa tion of PVC conduit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes ,junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC c opper wire from D.B. to switchboard as required is also in the scope of the contractor:
1 light point controlled by 1 switch
2 light points controlled by 1 switch
3 light points controlled by 1 switch
4 light points controlled by 1 switch
Ceiling fan wiring: Wiring with PVC insulated 2.5 sqmm copper conductor wire for fan points (1 fan point controlled by 1 modular swi tch) including providing space for electronic regulator in switch box, providing and fixing fan hook in the ceiling as per specifica tions and drawings.
Exhaust fan / wall bracket fan wiring: Wiring with PVC insulated 2.5 sqmm copper conductor wire for phase & neutral , 650 V grade in cluding earthing , the third pin with 1.5 sqmm copper conductor earthing insulated continuity wire for exhaust/ wall bracket fan inc luding providing and fixing of 5 pin 6 A modular socket and 10 A modular switch near the door or as as per specifications and drawin gs. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st exhaust fan for multiple exhaust fans in one c ircuit.
16 A power plug point wiring: Wiring for 250 V single phase and neutral 16 amps modular power plug point with PVC insulated 4 sq. mm . copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 2.5 sq. mm copper conductor earthin g insulated continuity wire, complete with providing and fixing of 6 pin 16/6A modular socket and 20/10 A modular switch (1 plug poi nt per circuit) as per specifications and drawings
6 A plug point wiring: Wiring for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. copper con ductor wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 5 pin 6A modular socket and 10 A modular switch (1 plug point per circuit) as per specifications and drawings.
AC point wiring: ,,Point wiring for power plug point with 4 sq.mm stranded PVC insulated copper wire including earthing the third pin with 2.5 sq. mm copper insulated earthing wire complete with supply and fixing of recessed mounted industrial type 3 pin 32 A metal clad socket and plug, 20A MCB (Motor duty) housed in a 16 gauge M.S. Box
Swan neck lighting pole with LED well glass light: Supply, installation, testing and commissioning of swan neck lighting pole of 100 mm nominal Diameter B class MS pipe (Height of bottom of light fitting shall be 5 meters from FGL), having base Plate 200mmx200mmx5m m along with Flameproof and Weatherproof 2x18W LED well glass light fitting complete with lamp and builtin control gear and choke of approved make, including supply and installation of earthing conductor of 8 SWG GI wire, nuts, bolts, Neck portion of lighting pole shall made up be of 50mm diameter GI pipe (radius of neck shall be 250mm). The pole shall be painted with 01 coat of primer and 02 coats of aluminium paint. The job shall also include supply and installation of 4 way Flameproof/weather proof junction box (with 4 cable entries) having 8 Nos., 6A, 440V shrouded terminal, with double compression FLP glands/lugs with looping arrangement and suppl y and termination of 3C X 2.5 sq. mm. armoured copper PVC/XLPE insulated cable from JB to light fitting The job complete in all resp ects as per specifications, drawings and instructions of EIC / Site engineer.
PVC Conduit pipes - Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providi ng necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including makin g good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge includin g cost of all labour, materials etc.: 25 mm
Supplying and laying reinforced cement concrete light duty hume pipe, non pressure type (NP3), centrifugally cast conforming to I.S. 458 with 1:3:6 concrete casing at joints as required with necessary slope including excavation, backfilling, supply of collars, join ting of pipes with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand), testing of joints, complete in all respects as per specifications, drawing and the direction of the EIC/Site Engineer: 300 mm dia
EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earth ing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing elect rodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-char ge, including the cost of all labour, tools, materials, etc. complete in all respect: Copper cable as per specifications - 10 Sq.mm
LED light fittings, Batten with 2XTLED-TMC501-2X TLED-36 W P3242 or equiavlent approved make with LEDs: Supply and fixing of wall mo unted/ suspended type weather proof light 2XTLED-TMC501-2X TLED or equiavlent approved make with LEDs, 36 W or more. LED Fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector block s etc including installation with LED of approved make.
ACB SERVICING AND TESTING (Make: ABB, Model: SACE E1N 08, Iu = 800A,Ue = 690 V, 50 kA for 1 sec) 1- Complete Servicing of ACB which shall include General Inspection of the Arcing and Main Contacts, Arcing Chamber, Main circuit – Busbars, Earthing Contacts, Geared Motor, Undervoltage release, Shunt release and Maintenance of Operating Mechanism, etc. complete in all aspects for healthy functioning of Air Circuit Breaker as per OEM recommendations. 2- Testing and Calibration of available alarms and protection functions i.e., (L, S, I and G) using compatible test kit of ABB as per OEM recommendations. 3-IR Test, Contact Resistance Measurement, Open/Close Timing, etc. any other tests required for healthy operation of ACB as per OEM recommendations. 4- Mobilization of testing kits and testing/maintenance personnel. 5- Workfront will be provided on the same day for both the air circuit breakers.
FIXED
Deployment of Semi Skilled Manpower During Schedule/ Breakdown / Maintenance of electrical equipments (2 Semi-skilled labour for Electrical at site). The rate is inclusive of Basic+VDA, EPF & ESI
Semi Skilled - Bonus @ 8.33% of Basic+VD
Semi Skilled - Retrenchment Compensation @ 4.5% of Basic+VDA This Line Item shall be paid as per Statutory Acts
Semi Skilled - Leave with Wages @ 5% of Basic+VDA This Line Item shall be paid as per Statutory Acts
Insurance Scheme (PMJBY @ Rs. 20.00 & PMSBY @ Rs. 436.00
Overtime calculation of Semi-Skilled Workers (2*Normal Wage per Hour) Hours Expected Per Month= 6 hrs
Providing Skilled Manpower as on when du
Providing Unskilled Manpower as on when during Scheduled Major Preventive / Breakdown Maintenance as per instructions of Engineer-In-Charge
Arrear Reimbursement Note: This line item shall be operated only in case of wage revision w.e.f 01.04.2026
Reimbursement for supplying spare parts of Air Conditioners to replace defective parts that are not included in Variable Part of SOR and their scope of work, as per direction of Engineer-in-Charge and scope of work. Note: This item shall be paid as per actuals, based on invoiced value of spare part from Original Equipment Manufacturer/Authorised Dealer
Reimbursement for supply of consumables mentioned in Annexure-B7of Special Conditions of Contract (Technical). These consumables are for usage in general upkeep and maintenance jobs. Consumables required for executing works as per variable part of SoR shall be supplied by the contractor as per SoR/Scope of Work. Note: This line item shall be operated as per directions of Engineer-in-Charge
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.31 MB
TenderDoc.pdf
Tender Documents • 18.07 MB
Newfolder.rar
Additional Documents • 1.05 MB
BOQ_199020.xls
BOQ • 0.45 MB
Tender-Acceptance-Format.pdf
Additional Documents • 0.08 MB
FAQs-IOCL-Online-EMD.pdf
Additional Documents • 0.55 MB
Special_Instructions_to_the_Bidders_Version_5_dated_30_June_2025.pdf
Additional Documents • 2.80 MB
Download all tender documents and submit your bid