Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance S 37 KHATIPURA ROAD JHOTWARA JAIPUR RAJASTHAN 302012 | JAIPUR | RAJASTHAN | 302012 | Admitted-Finance |
| 2 | Not Admitted-Finance G 3 248 PADMAWATI COLONY B KINGS ROAD NIRMAN NAGAR JAIPUR RAJASTHAN 302019 | JAIPUR | RAJASTHAN | 302019 | Not Admitted-Finance Not qualified for AOC |
| 3 | Not Admitted-Finance 21 FIRST FLOOR CLUB ROAD NEW DELHI WEST PUNJABI BAGH WEST DELHI DELHI 110026 | WEST DELHI | DELHI | 110026 | Not Admitted-Finance Not qualified for AOC |
| 4 | Not Admitted-Fee/PreQual/Technical 552 8TH C ROAD BEHIND SATSANG BHAWAN SARDARPURA JODHPUR RAJASTHAN 342001 | JODHPUR | RAJASTHAN | 342001 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical 3526 TIMBER MARKET AMBALA CANTT HARYANA 133001 | AMBALA | HARYANA | 133001 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
8 Jul 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Principal and controller
Govt. Engg. College, Barmer
Lab equipments and Softwares for different labs Petroleum Engg., Civil Engg., Electrical Engg., Mechanical Engg., Electronics and Communication Engg.
2020_ECBMR_187836_14
NIT_No_04_2020_2021
Open Tender
Laboratory and scientific equipment
Turn-key
30 days
BARMER
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
PRINCIPAL, ENGINEERING COLLEGE, BARMER
₹50,000
Yes
19 Oct 2020
26 Jun 2020
9 Jul 2020
26 Jun 2020
8 Jul 2020
26 Jun 2020
90 days
Amount
To perform O.C. and S.C. test on a 1-phase transformer and to determine the parameters of its equivalent circuit its voltage regulation and efficiency. To determine the efficiency and voltage regulation of a single-phase transformer by direct loading.
To perform sumpner’s test on two identical 1-phase transformers and find their efficiency & parameters of the equivalent circuit.
To perform the heat run test on a delta/delta connected 3-phase transformer and determine the parameters for its equivalent circuit.
To perform the parallel operation of the transformer to obtain data to study the load sharing.
Separation of no load losses in single phase transformer.
To study conversion of three-phase supply to two-phase supply using Scott Connection.
Speed Control of DC Shunt Motor by Field current Control method & plot curve for speed versus field current. Speed Control of DC Shunt Motor by Armature Voltage Control method & plot curve for speed versus Armature Voltage.
To determine the efficiency at full load of a DC Shunt motor by performing Swineburne’s test.
To perform Hopkinson’s test on two similar DC shunt machines and hence obtain their efficiencies at various loads.
Study of Various Types of Starters for Induction Motor
To connect two 3-phase induction motor in cascade and study their speed control.
To Perform Load Test on3 phase induction motor and calculate input power , output power , torque, efficiency, input power factor, and slip for various load settings.
To perform No load and blocked rotor test on a 3 phase induction motor & determine parameters of equivalent circuits. Draw the circle diagram and compute the following 1) Max. Torque 2) Currrent 3) Slip 4) PF 5) Efficiency
To plot OCC and SCC of an Alternator To determine regulation using potier reactance method To determine voltage regulation using direct loading To determine voltage regulation of alternator using synchronous impedance method
To Synchronize an alternator across the infinite bus and control sharing .
To study effect of variation of field current upon the stator current and power factor of synchronous motor and plot V curves and inverted V curves of Synchronous motor For different values of loads
Speed control of 3- Φ Induction Motor
Xq and Xd of Alternator
DC Rectifier Unit - COMMON for both sem
Electrical Distribution and Control Panel - COMMON for both sem
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .