| 1.00Necessary arrangements for removing of chemical smell sprayed in sorrounding at passage area of anatomy department of H.B.T. Medical College Juhu Mumbai. | |||||
| 1.01 | Providing aluminium supply air diffusers & return air grills with volume control dampers | 10 | Sqm | 18,775 ₹1,87,750 | 18,585 ₹1,85,850 Lowest |
| 1.02 | Supply and installation of volume control dampers, bypass dampers. | 8 | Sqm | 14,207 ₹1,13,656 | 14,063 ₹1,12,504 Lowest |
| 1.03 | GSS Ducting:- 20 SWG | 388 | Sqm | 2,062 ₹8,00,056 | 2,041 ₹7,91,908 Lowest |
| 1.04 | Work of supply and Installation of blower/ exhaust fan assembly for capacity of blower will be approx. 18000 CuM / Hr. at 300mm to 400mm WG pressure the impeller and casing shall be fabricated from SS 304 material. The impeller shall be dynamically balanced. The blower shall be coupled with 3Ph, 440V, 50 Hz T.E.F.C. Squirrel cage inductions motor (Crompton/ABB/Siemens) of suitable capacity, as per ISI specification. The blower assembly shall have silencer with antivibration absorbed to reduce noise. The blower casing shall have inspection cover and separate drain plug at bottom to remove moisture entrapped. Including 1 set of rotating element of blower set. | 1 | Nos. | 6,97,314 ₹6,97,314 | 6,90,300 ₹6,90,300 Lowest |
| 1.05 | 415V Pump panel with 63A MCCB as incomer with phase indicator and ammeter & voltmeter with selector switches, 2Noss. Of 25A MPCB with DOL Starter, local push button station & contactor of required rating as outgoing. | 1 | Nos. | 91,092 ₹91,092 | 90,171 ₹90,171 Lowest |
| 1.06 | 1st category Cu armoured cables FRLSZ outer sheathed- 4C x 10 Sq.mm | 35 | Mtr | 695 ₹24,325 | 688 ₹24,080 Lowest |
| 1.07 | 1st category Cu armoured cables FRLSZ outer sheathed- 4C x 25 Sq.mm | 50 | Mtr | 1,387.98 ₹69,399 | 1,374 ₹68,700 Lowest |
| 1.08 | Cable End Termination For Copper Cables – 4C x 10 Sq.mm | 4 | Set | 195 ₹780 | 193 ₹772 Lowest |
| 1.09 | Cable End Termination For Copper Cables – 4C x 25 Sq.mm | 2 | Set | 328 ₹656 | 325 ₹650 Lowest |
Tender Value
₹25.0 L
EMD Value
₹25,000
Closing Date
5 Feb 2025, 4:00 pmClosed
Dean
H.B.T.Medical College and Dr.R.N.Cooper Mun.Gen. Hospital,Vile Parle (W),Mumbai
Necessary arrangements for removing of chemical smell sprayed in sorrounding at passage area of anatomy department of H.B.T. Medical College Juhu Mumbai.
2025_MCGM_1142301_1
HO/2583/RNCH/Dt.21.01.2025
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
H.B.T.Medical College and Dr.R.N.Cooper Mun.Gen. H
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,894
₹25,000
1 Jan 2026
29 Jan 2025
6 Feb 2025
29 Jan 2025
5 Feb 2025
29 Jan 2025
Amount
Necessary arrangements for removing of chemical smell sprayed in sorrounding at passage area of anatomy department of H.B.T. Medical College Juhu Mumbai.
Providing aluminium supply air diffusers & return air grills with volume control dampers
Supply and installation of volume control dampers, bypass dampers.
GSS Ducting:- 20 SWG
Work of supply and Installation of blower/ exhaust fan assembly for capacity of blower will be approx. 18000 CuM / Hr. at 300mm to 400mm WG pressure the impeller and casing shall be fabricated from SS 304 material. The impeller shall be dynamically balanced. The blower shall be coupled with 3Ph, 440V, 50 Hz T.E.F.C. Squirrel cage inductions motor (Crompton/ABB/Siemens) of suitable capacity, as per ISI specification. The blower assembly shall have silencer with antivibration absorbed to reduce noise. The blower casing shall have inspection cover and separate drain plug at bottom to remove moisture entrapped. Including 1 set of rotating element of blower set.
1st category Cu armoured cables FRLSZ outer sheathed- 4C x 10 Sq.mm
1st category Cu armoured cables FRLSZ outer sheathed- 4C x 25 Sq.mm
Cable End Termination For Copper Cables – 4C x 10 Sq.mm
Cable End Termination For Copper Cables – 4C x 25 Sq.mm
ELCB with 100 mA sensitivity 100 A , 4 pole
63A 4P MCB
40A FP MCB
Supply & installation of Main electrical panel with VFD(7.5KW-1Nos, 1.5KW-2 Nos) Recessed luminair,
Cubical Panel (Fabricated from CRCA sheet steel SWG 16, powder coated, rust protected enclosure, IP 52)
Providing and fixing M. S. black pipes for columns, including base plate & cap plate 6 mm. thick foundation bolts, nuts, etc., complete with 3 coats of approved synthetic paint etc., complete as directed. Pipes shall be of Tata or equivalent make. Dia of pole 75 mm. 'C' class
Providing, detailing, fabricating and fixing at desired location using M.S. chequered Plates of any thickness and of grade Fe250 as per specifications and approved fabrication drawings (which are to be prepared by Contractor and got approved from Engineer), including transporation of the same to site, erection at all heights and levels, provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, and all necessary operations like preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding and removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30 microns after fabrication including touching up with spray painting after erection etc complete as directed by Engineer In Charge.
OMEX CONTROL SYSTEM (BID ID -6469995)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .