Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder. | |
| 2 | L2₹23.6 L+₹1.0 L (4.53%)Rejected-Finance | L2 | Rejected-Finance Not Lowest. | |
| 3 | L3₹23.7 L+₹1.1 L (4.80%)Rejected-Finance | L3 | Rejected-Finance Not Lowest. | |
| 4 | L4₹24.5 L+₹1.9 L (8.25%)Rejected-Finance | L4 | Rejected-Finance Not Lowest. | |
| 5 | L5₹25.6 L+₹3.0 L (13.2%)Rejected-Finance SAI VILLA C 65 EKTA NAGAR BAREILLY UTTAR PRADESH 243 122 | BAREILLY | UTTAR PRADESH | 243122 | L5 | Rejected-Finance Not Lowest. |
Tender Value
₹23.3 L
EMD Value
₹46,600
Closing Date
18 Jan 2020, 6:00 pmClosed
GE Kamptee
Garrison Engineer, Military Engineer Services, Kamptee Cantt - 441 001
SPECIAL REPAIRS TO SEWAGE LINE, SEPTIC TANK NEAR BLDG NO P-09, P-13 AND P-14 OF 414 ASC BN TA AND CERTAIN SANCTIONED WORKS OF VARIOUS UNITS UNDER AGE B/R-II AT KAMPTEE.
2019_MES_308874_1
8139/E8
Open Tender
Civil Works
Item Rate
180 days
Kamptee
Class E, Cat a (i)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹46,600
Yes
28 Jan 2020
23 Dec 2019
20 Jan 2020
24 Dec 2019
18 Jan 2020
8 Jan 2020
24 Dec 2019 - 7 Jan 2020
Amount
Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, pillars etc and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 50m complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation over areas not exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
All as per item No. 4 above but depth exc 1.5m and not exc 3.0m deep complete all as specified and directed.
Excavation over areas not exc 1.5m deep and getting out in hard / dense soil complete all as specified and directed.
All as per item No. 6 above but depth exc 1.5m and not exc 3.0m deep complete all as specified and directed.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc not exc 10 sqm on plan and not exc 1.5m in depth and getting out in hard/dense complete all as specified and directed.
All as per item No. 8 above but depth exc 1.5m and not exc 3.0m deep complete all as specified and directed.
Excavating in post holes (or similar holes) each not exc 0.5 cum getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm, watering and removing surplus soil to a distance not exc 50m and making good to surface complete all as specified and directed.
M&L for hardcore of gauge not exc 63mm deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface, broken stones or boulders complete all as specified and directed.
M&L for 75mm thick cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base to floors finished fair and even complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for brick work with fly ash brick, old size, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and as directed.
All as per item No 14 above but half brick thick wall in CM 1:4 complete all as specified and directed.
M&L for brick work with fly ash bricks, old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with sub class ‘B’ common burnt clay bricks, old size, in one brick thick honey comb walling, built in cement mortar (1:4) complete all as specified and directed.
Taking down cement or cement lime plastering including roots of trees and trees of any girth, desription on brick or stone wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on brick work or concrete sufaces, finished even and smooth without using extra cement complete all as specified and directed.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landing horizontal or slopping similar work not exc 200mm thick and flat fair finished surfaces complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breakes in floor, window cills, concrete railings, opening in concrete walls, floors and roofs not exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide complete all as specified and directed.
M&L for loose filling with aggregates of guage 80 to 150mm with broken bricks in soakage pits / soakage wells complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping including weathering, throating and necessary formwork complete all as specified and directed.
Demolition of RCC in suspended work and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
M&L for precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, mangers, shelves and similar articles with plain faces and set in CM 1:6 complete all as specified and directed. Note:- Reinforcement shall be measured and paid separately.
M&L for providing reinforcement cement concrete 1:1.5:3, type A1 (Nominal Mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likes complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending and binding with mild steel (anneal) wire not less than 0.90mm dia complete all as specified and directed.
M&L for mild steel TMT bars of 8mm dia, cut to length, bent to shape required, including cranking, bending and binding with mild steel (anneal) wire not less than 0.90mm dia complete all as specified and directed.
Demolition and breaking up of 150mm dia drain pipes of any type (SGSW/AC or reinforced concrete pipe) set in cement mortar complete all as specified and directed.
M&L for laying 150mm dia salt glazed stone ware drain pipes of grade ‘A’ and jointed in cement mortar and tested on completion, complete all as specified and directed.
M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 for 150mm dia pipe complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft / loose soil complete all as specified and directed.
Removing excavated material (soil) not exc 50m and deposited where directed at a level not exc 1.5m above the strating point complete all as specified and directed.
Dismantling PVC pipes 110/75mm jointed in cement mortar and taking out of trenches/ from walls including fittings as bends, branch pieces, traps etc complete all as specified and directed.
M&L for 75mm PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S&F 75mm dia PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) 110mm bore vent cowl complete all as specified and directed.
Cutting into exisiting manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching and forming branch channel, half round or 3/4 section in cement concrete 1:2:4 type 'B' smooth finished and reforming benching as required, internal dia of pipe 150mm complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
M&L for 40mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) for flooring finished even & smooth using extra cement complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate), finished even & smooth without using extra cement as in plinth protection including bitumen/ mast filling in the joint complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in flooring/ hardstanding/ footpath finished even and fair, laid in alternate panels complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in flooring/ hardstanding finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces of wall including cornices, pilasters etc and applying two coats of white wash complete all as specified and directed.
M&L for preparation of new plastered white washed surfaces and applying with three coats of white wash over wall surfaces complete all as specified and directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other coveing, door etc to be prepared for hanging or sliding and with and inclduing either hooks and hinges or steel handing door fitting (exclusive of steel, sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe 290 (Gde E-165) complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tube conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410-W(Gde E-250) quality-A complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth & applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws / J hooks complete all as specified and directed.
M&L for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for 11 to 15mm mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 but not exc 10cm long complete all as specified and directed.
Point wiring 1100 volt grade single core FRLSH PVC insulated & unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marking medium grade on surface of wall/ceilling including FRLSH PVC insulated unsheathed earth wire with copper conductor of size 1.50 sqmm pressed steel terminal modular boxes sunk on wall for mounting of switches switch sockets fan regulator etc including modular white cover plate suitable for mounting modular switches, sockets, fan regulator etc complete all as specified and making good to distrubed surfaces for one light point controlled by one, one way switch. Note: Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, cieling roses and holders shall be connected to common earth dolly.
All as per item No 57 above but one ceiling /exhaust/ wall mounted fan point controlled by one switch and regulator complete all as specified and directed.
All as per item No 57 above but one 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
S&F modular switch 1 way, 6 amp 250 volts AC ,1 module complete all as specified and directed.
S&F modular socket 6A- 2/3 pin combined, 2 module, 250 volts, AC complete all as specified and directed.
S&F ceiling rose surface type, 2/3 terminal, 5 amps complete all as specified and directed.
S&F modular fan regulator, step type, 120 W, 2 module complete all as specified and directed.
S&F 18/22 watts LED tube light fittings complete with aluminium body including tube rod, driver with not less than 2000lumen output and input rated voltage 240 V, connecting with 2 core 1 sqmm copper conductor cable complete all as specified and directed. Make:- Philips Cat part No Astra line 20W, CG Cat No LCTL-18-CDL, Surya Cat No SLE BT 20.
S&F building security light LED 20-25 watt with lumen output 200 with driver, rated voltage 240V, 50 Hz including mounting GI, made out of 25mm dia light grade pipe, 0.8m bent to shape including FI clamps, nut bolts etc complete all as specified and directed. Make:- Philips Cat No BRP022 LED 20CW, CG Cat No LSTS-25-CDL.
S&F LED light fitting surface mounted bulk head luminaries 9-12W with min 800 lumen, IP 65, aluminium housing, surge protection including drivers etc complete with all accessories and including connecting up with twin core twisted flexible cable suitable size of 230V, 50Hz complete all as specified and directed. Make:- Philips Cat No Endura LED 10W, Luker LBKOVSL04, C&S Sirus 10W, CG LBH 10CDL.
S&F ceiling fan 1200 mm sweep, single phase, 230V AC 50Hz with clamp set complete all as specified and directed.
S&F sheet metal enclosure, single pole & neutral for 240 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.
S&F MCB single pole, 240 volt, 6 to 40 amps, 10 KA complete all as specified and directed.
S&F sheet metal enclosure, single pole and neutral, with two pin and earth plug and socket with one single pole MCB's, 20 Amps, 240V, returning capacity 10 KA, 'C' series complete all as specified and directed.
M&L for earthing complete with galvanised steet earth plate electrode 600 x 600 x 6mm thick burried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr below the normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts nuts check nuts & washer of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for:- (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm. (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminium lugs etc all as specified. (e) 15mm nominal bore meduim grade GI protection pipe upto 7.50 metre long for protection of earthing lead. (f) Reguisite quantity of charcoal and common salt. (g) Connection to earthing test point and testing on completion.
S&F double wall corrugated high density polymer ethyl (HDEP) pipe for laying of electric cable of size 50mm outer dia and 38mm inner dia with IS 14930 (part 2) 2001 and 6mm thickness laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
M&L for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volt grade laid in trenches, passing through pipes / ducts including testing for cable of 2 core 6 sqmm cross sectional area complete all as specified and directed.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.30,250.00]
M/s DS Khekde
DE PRETTY AND CO
Meet Road Lines
North India Pest Control
Bidder Name
Meet Road Lines
North India Pest Control
DE PRETTY AND CO
SHUB CONSTRUTION
M/s DS Khekde
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .