Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Lowest Bid |
| 2 | L2₹1.3 Cr+₹7.4 L (5.91%)Rejected-Finance | ₹1.3 Cr+₹7.4 L (5.91%) | L2 | Rejected-Finance Higher Bid |
| 3 | L3₹1.3 Cr+₹8.0 L (6.35%)Rejected-Finance | ₹1.3 Cr+₹8.0 L (6.35%) | L3 | Rejected-Finance Higher Bid |
Tender Value
₹1.5 Cr
EMD Value
₹1.5 L
Closing Date
2 Sept 2023, 11:00 amClosed
Executive Engineer, Yingkiong Division, PWD
O/o the Executive Engineer, Yingkiong Division, PWD
Construction of BDO CDPO and BEO Office at Payindem Upper Siang
2023_PWDAP_1363_1
YA/NIT/SIDF/2023-24/04
Open Tender
Civil Works
Item Rate
365 days
At Payindem
Please refer to tender documents
2 documents required · 2 mandatory
₹0
₹1.5 L
Yes
8 Jan 2024
23 Aug 2023
4 Sept 2023
23 Aug 2023
2 Sept 2023
24 Aug 2023
23 Aug 2023 - 2 Sept 2023
Amount
COST FOR 3 UNITS SH: SITE DEVELOPMENT
Earth work in excavationin all kinds of soil (excluding soil containing 50% or more os shingle or small size boulders upto 30cm size, saturated soil and rock) including banking in 20cm layera and braking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 50 m and lift upto 1.50m
Excavation in decomposed or soft rock without blasting i/c disposal of the same lead upto 50m and lift upto 1.50m
SH: BUILDING PORTION
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Providing and laying in foundations and plinth cement concrete 1:3:6(1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) excluding the cost of centering and shuttering.
Providing and laying cement concrete 1 : 2 : 4 (1 cement : coarse sand : 4 graded stone shingle 40 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth
Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.
b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
c) Column, pillars, posts and struts etc.
d) Lintels, beams, girders, bressumers and cantilevers etc.
e) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. c) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a)1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Masonry with pre-cast cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) blocks in cement mortar 1 : 4 (1 cement : 4 fine sand)for percast cement block masonary in super structure above plinth upto floor two level.
Extra for pre-cast cement concrete block masonry in superstructure above plinth level up to floor two level.
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 35mm thick
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill.
Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position.
Steel work in single section including cutting, hoisting fixing in position and applying a priming coat of red leap paint. a) In RSs Joist
Providing and fixing bolts above 300 mm in length including nuts and washers complete.
Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses. a) 0.63mm thick
Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. a) 0.63mm thick
Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately).
Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.
Extra for making chamfered edges of beading.
12 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. Long Pan patten WC Pan
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone shingle 40 mm nominal size).
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100 mm dia SW pipes
Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design. a) 100 mm dia SW pipes
Providing and fixing Aluminium sliding door bolts anodised transperent or dyed to requred colour or shade with nuts and scrows etc complete. a) 300 x 16 mm
Providing and fixing Aluminium tower bolts anodised or transperent or dyed to requred colour or shade with necessary screws etc complete. a) 250 x 10 mm
Providing and fixing Aluminium handels anodised or transperent or dyed to requred colour or shade with necessary screws etc complete. a) 100 mm
Providing and fixing MS Hooks and Eyes. a) 300 mm
White washing with lime on new work (two or more coats) to give an even shade.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). a) 20 mm nominal bore
Providing and fixing brass bib cock of approved quality. b)15 mm nominal bore
Providing and fixing brass stop cock of approved quality. b)15 mm nominal bore
Providing and fixing sand cast iron single equal plain junction of required degree. a) 100 x 100 x 100 mm
Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality).
Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers.
ELECTRICAL INSTALLATIONS (Details for 3 Unit) POINT WIRING
Wiring for light point /fan point /exhaust fan point /wall fan/call bell point with 1.5 sq. mm. FRLS PVC insulated, copper conductor single core cable in surface/recessed medium class PVC Conduite with piano type switch, phenolic laminated sheet, suitable size MS box and Earthing point with 1.5 mm FRLS PVC insulated copper conductor single core cable required: Group -B
Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 no. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 no. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / sub mains wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a)2x2.5 sq.mm + 1x2.5 sq.mm earth wire.
b)4x10sq.mm + 2x10 sq.mm earth wire.
Supplying and fixing metal box of 150 mm x 75 mm x 60 mm deep ( nominal size ) on surfance or in recess with suitable size phenolic laminated sheet cover in the front including provinding and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connections, painting etc. as required. ( For light plugs to be used only in non- residential buildings).
Supplying and fixing metal box of following size (nominal sizes) on surfance or in recess with suitable size phenolic laminated sheet cover in the front including painting etc. as required. ( For power plugs). a)150mm x 75mm x 60mm deep
Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required : 25 mm dia.
Installation, testing and commissioning of prewired, flourescent fittings/ CFL of all types, complete with all accessories and tube etc. directly on ceiling/wall, including connections with 1.5 sq.mm. PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down roads of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Numbering of ceiling fan/exhaust fan/air circulator/flourescent fitting as required
Upto 450mm sweep.
Supplying and making end terminations with brass compression gland for PVC insulated and PVC sheathed Aluminium Conductor cable of 1.1 KV grade of the following sizes as required including providing crimping heavy duty copper lugs a)1.1 KV 4 x 16 sq. mm AYFY Cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq. mm on surface as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) complete as required.
Supplying and laying 25mm x 5mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt and spring washer spaced at 50mm).
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supply the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. a)1 x 40 watts Flourescent Light Fixture as per Bajaj Cat No. BJIE 136/140
b)12" dia (1400 r.p.m) Exhaust Fan with bird guard screen and gravity louvers complete.
c)48 " dia ( 1200 mm sweep ) ceiling fan .
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
M/s Gesar Enterprises
Er. Miss Purnima Nangkar
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1490.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .