EXECUTIVE ENGINEER
Executive Engineer PWD Buildings C and M Division Thiruvallur
Special repairs to leaky roof and painting in PHC at Nemam
2024_PWD_509558_2
22/DB/JDO-1/F-6/2024-25
Open Tender
Civil Works - Buildings
Item Wise
60 days
nemam
Please refer tender document
6 documents required · 6 mandatory
₹0
₹19,400
27 Dec 2024
10 Dec 2024
12 Dec 2024
10 Dec 2024
12 Dec 2024
10 Dec 2024
Amount
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls Floor finish and dadooing walls in cement mortar with mosaic tiles / glazed tiles / cuddapah slabs.
Supplying and filling in foundation, basement, etc with Crushed Stone sand filling in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Relaying of Standardised Concrete Mix M-20 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite store jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ration of 0.55, including admixture (plasticiser/Super plasticiser) in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improveworkability without impairing strength and durability with about (5 cu.m.) 7730 kg of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing etc., and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of mateials).
S.S. in Ground Floor
Renewing and refixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed.
75mm thick slab (using 20mm HBGS Jelly)
Renewing the damaged flooring with Self design colour Ceramic Tiles of size 305 x 305 x 6mm laid over 20mm thick cement mortar 1:3 (One cement and Three M-sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK or Equivalent which has to be got approved by executive Engineer before use on works)
Renewing and repointing roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
Renewing the damaged top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
Relaying of Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Replastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Replastering with Cement Mortar 1:5 (One cement and Five sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Repainting two coats of newly plastered wall surface with ready mixed Interior plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Repainting the water proofing coating for terraces with ready mixed water proofing paint two coats over one coat of crack paste over one coat cement paint including through scrapping clean removal of dirt, etc., complying with standard specifications and as directed by the departmental officers. (The colour and shade of the ready mixed water proofing paint shall be got approved by the Executive Engineer before use of work)
Repainting old iron works such as steel doors, windows, ventilators, window bars, balustrades etc. with two coats of best approved first quality and colour in all floors etc., including cost of scrapping charges complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works).
Renewing and refixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works).
Renewing and refixing in position of aluminium natural colour matt finish louvered ventilator in all floors made with extruded aluminium section of following size with necessary accessories such as rubber beading, best quality of handle including supplying and fixing of 4 mm thick plain glass including cost of all materials, labour power consumption required for fabrication drilling holes in RCC column/floor slab/ masonry wall wherever necessary with power drills to the required extent and making good to the original condition after fixing etc., and as directed by the departmental officers etc. complete. The aluminium frames to be anodised under electrically controlled condition in accordance with ISI 1868/ 1962 specification for an average anodic film thickness of not less 15 microns and all the materials should be got approved by the Executive Engineer before use on work.
Sub Total Amount for above all items (excluding GST)
GST 18% for above SubTotal Amount
MANIKANDAN (BID ID -1206719)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_606057.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .