| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC 38 30 92 SAI NAGAR MARRIPALEM VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹27.3 L+₹1.6 L (6.42%)Rejected-Finance INDEX NO D 01 HQ CE SC PUNE SHOP NO 06 FIRST FLOOR OPP CHAMUNDA HOTEL AT BOKHIRA DIST PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹30.2 L+₹4.6 L (17.7%)Rejected-Finance HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹32.4 L+₹6.8 L (26.3%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹34.1 L+₹8.4 L (32.8%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
8 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER DAMAN
Garrison Engineer Daman, Tat RakshakVihar, Dalwada, Nani Daman Post, Daman (UT) PIN396210
ADDITIONAL ALTERATION AND SPECIAL REPAIRS TO UNIT SHOPS BUILDING NO P 125 AT TRV ICGAS DAMAN
2023_MES_631116_1
8722/E8
Open Tender
Civil Works
Works
180 days
DAMAN
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER DAMAN
₹62,000
20 Mar 2024
5 Dec 2023
10 Jan 2024
5 Dec 2023
8 Jan 2024
25 Dec 2023
Amount
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. and removal of debris out side from MD land etc complete all as specified and directed.
Demolition of plain cement concrete and pavings (unreinforced) in any position (below or above ground level) n exc 15 cm thick and removal of the same outside MD land etc complete all as specified and directed.
Dismantling stone sett / interlocking paver tiles of any description or thickness laid dry or laid dry and pointed.
Excavation over areas not exceeding 1.50m deep and getting out in soft/loose soil all as specified and as directed.
M&L for brickwork with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) etc complete all as specified and as directed.
Taking down door/ window shutter with frame without taking off shutters from frame of any description exc. 1.50 Sqm not exc 4.00 Sqm each etc complete all as specified and as direted.
Taking down cement plaster on brick masonry walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water and removal of debries out side from MD land etc complete all as specified and directed.
M&L for 15mm thick rendering in Cement Mortar 1:6, internal plaster on brick/concrete surfaces and surfaces finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for rendering in Cement Mortar 1:4, 20 mm thick in two coats (15 mm under coat + 5mm finishing coat) on brick/concrete surfaces with 3% water proofing compound in finishing coat and finishing the surface even and fair complete all as specified and directed. (Note :- WPC will be measured and paid seperately).
Supply only integral WPC all as specified & directed.
M&L for preparation of newly plastered surfaces of wall and applying one coat of wall primer to the surfaces and finally applying two coats of oil bound distemper, complete all as specified and as directed.
M&L for preparation on new plastered surface of wall, chajja, parapet etc and applying two coats of weather proof acrylic emulsion paint over a coat of acrylic primer etc complete all as specified and as directed.
M&L for preparation of existing painted surfaces of walls, chajjas, parapets etc and applying one coat of acrylic exterior paint (Brand Apcolite Apex manufactured by Asian Paints or equivalent as approved by GE), as per the manufactures instructions and as directed , removing the loose materials and filled with crack sealing compound of approved make if necessary including scaffolding etc complete all as specified and as directed.
M&L for complete removal of existing treatment and preparation of surfaces including filling of the holes/cracks on walls with plaster putty and applying two coats of oil bound distemper paint on walls over a coat of alkali resistant primer etc complete all as specified and as directed .
M&L for preparation of old decorated surfaces and applying one coat of white wash on walls complete all as specified and as directed.
M&L for preparation of old decorated surfaces and applying one coat of white wash on ceiling complete all as specified and as directed.
S&F for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured to match coloured tiles over 15 mm screed bedding in cement mortar 1:4, including dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
S&F for glazed ceramic coloured tiles 350x250x7mm/ 450x350x7mm thick in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 15 mm screed bedding in cement mortar 1:4 including dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
S&F for glazed ceramic coloured tiles 350x250x7mm/ 450x350x7mm thick on vertical surfaces such as skirting / dados set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick rendering in CM (1:4) as in backing coat including dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
S&F for vitrified coloured tiles of 9-10 mm thick (square / rectangular) area of each tiles not exc 0.36 sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured to match coloured tiles over 15 mm screed bedding in cement mortar 1:4 including dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
All as per item No 22 above but on vertical surfaces such as skirting / dados including 15 mm thick rendering in CM (1:4) as in backing coat complete all as specified and directed.
M&L for mirror polished Kota stone 20 to 25 mm thick hand cut to size 430mm x580mm in floors, set and jointed in neat cement slurry and pointed in coloured cement with and including 20 mm thick CM (1:6) bedding concrete etc inculding dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. and removal of debris out side from MD land etc complete all as specified and directed.
M&L machine cut and premirror polished kota stone slab 20 to 25mm thick as in vertical surfaces like risers, skirtings etc, fixed and jointed in neat grey cement slurry and pointed with cement and pigments to match the shade of slab including 20 mm thick screed bed in CM (1:6) inculding dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. and removal of debris out side from MD land etc complete all as specified and directed.
M&L for grinding & mirror polishing existing kota stone flooring
M&L black Cuddappa stone slab 20 to 25mm thick as in shelves, partitions etc, laid and jointed in neat cement slurry and pointed with cement and pigments to match the shade of slab including rubbing & polishing cutting of brick walls & making good with and including 15 mm thick screed bed in CM (1:6) including dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. and removal of debris out side from MD land etc complete all as specified and directed.
Dismantling of mud phuska or concrete bedding including Complete removal of existing water proofing treatment and cleaning of original roof by brooming, washing and roughening roof surface complete all as specified and directed
Material and labour PCC 1:2:4 type B-1 using 20mm gradeded mechanically crushed stone aggregate complete all as specified and directed
M&L for 15mm thick screed bed in CM (1:4) laid on roof surfaces mixed with itegral water proofing compound @ 3% by weight of cement, including finishing the surfaces even and smooth without using extra cement. (Note: WPC shall be measured and paid separately at supply ratesall as specified and directed.
M&L for WPT to non accessible RCC roof slab/chajja/canopy/parapet etc or accesible roof to be executed, surface thoroughly wire brushed, washed and dried up and cleaned of all foreign matter and dust to receive Shalitex primer @300 gms/sqm for laying 3.00 mm thick super thermolay (APP modified membrane with polyster reinforcement) 3.6 Kg/Sqm laid by torch application method and 75mm overlap in longitudinal direction and 100mm in transverse direction, a coat of silver shield (solar reflective aluminium paint) @ 0.12 Kg/Sqm all as per manufacturers instructions etc complete all as specified and as directed. Make- Tikitar, STP texas, Shivam Hyperplast, Pidilite all as specified and directed.
S&F in repairs 1.25mm thickness of laths steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete but gear operated type with chain wheel and hand chain complete all as specified and directed.
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide primer.
M&L for preparation of old painted steel surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for standard aluminium section "heavy grade" powder coated of approved colour as in sliding windows, Ventillators, partitions and doors frames, shutters of required sizes including, rubber gasket, PVC wheel with ball bearing, concealed type lock and fixing of glass complete all as specified and directed. Make of aluminium section - ''Jindal/ Indalco/ Hindalco. (Note: (i) The measurement shall be recorded weight of aluminium section only and rate quoted shall deemed inclusive of rubber gasket, rubber beading, PVC wheel with ball bearing, concealed type locks, handle etc (ii) Glass shall be measured and paid separately as supply only.
S&F 5.00 mm thick float glass fixed in aluminium sliding window shutters etc complete all sas specified and directed.
S&F Solar controlled film 50 micron reflective type sticked to glass as per instructions of manufacturers all specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and as directed.
S&F aluminium anodised XPM grill aluminium alloy DG 202 grill 4.8 mm thick (in the shape of expanded metal of aluminium XPM jalli) opening size 59mm (length expansion) and 45 mm (width expansion) fixed in and including E/H frame all as per manufacturers instruction and as directed.
S&F Aluminium (extruded section) body Door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 60 to 80 Kgs.
Hacking out old broken glass (any thickness, size quality or description from wooden/metal frames) glazed with putty or fixed with beads or screws etc complete all as specified and as directed.
S & F sheet glass 4 mm thick pin headed /figured glass fixed with rubber gaskets in aluminium ventilators or fixing with oil putty in steel/wooden ventilators in square not exc 0.5 Sqm in each pane (cost of using Jhulla system is included) fixed at any position including all necessary fittings etc complete all as specified and as directed.
S&F in repairs 15 mm dia bore medium grade galvanized steel tubing with all fittings fixed to walls, ceilings or laid under floors all as specified and directed.
S&F in repairs 20mm dia bore medium grade galvanised steel tubing with all fittings fixed to walls, ceilings or laid under floors complete all as specified and directed.
Disamantling of cast iron pipes of any description with fittings fixed to walls or laid in floors/trenches.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors including dismantling of cast iron pipes of any description with fittings complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls with fastners including dismantling of cast iron pipes of any description with fittings complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls with fastners including dismantling of cast iron pipes of any description with fittings complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm dia with access door
S&F PVC (SWR) bends any radius 110mm dia with access door
S&F PVC (SWR) vent cowl 75mm dia
S&F PVC (SWR) vent cowl 110mm dia
S & F in repairs PVC SWR floor trap with CP grating 75 mm dia of outlet including jointing with solvent cement etc complete all as specified and directed.
S&F in repairs waste coupling 32mm brass chromium plated ISI for WHB/sink complete all as specified and directed .
S&F in repairs standard size vitreous china EWC white colour with P/S trap white coloured with and including PVC white coloured seat cover,10 ltr capacity PVC valveless,syphonic action type, low level flushing cistern with inlet, ball valve, float valve and handle including brackets including all connecting to flushing cistern.
S&F in repair vitreous china WHB white, flat back size 550mm x 400 mm including cutting for and pinning in ends of CI brackets, pillar taps etc and making good wall or floor fitting to match existing surface complete all as specified and directed.
S&F in repair vitreous china, 1st quality urinal half stall type, white, with and including brass chromium plated flush pin, 40mm dia brass CP waste coupling and 40mm dia PVC HDPE waste pipe with all other necessary fittings etc complete all as specified and directed.
S&F in repairs Health Faucet with 1 meter CP flexible tube & hook and all necessary fittings all as specified and directed. (Make: Prayag or equivalent as peeroved)
S&F in repairs 2 way bib cock double handle with flange and all necessary fittings all as specified and directed.(Make: Prayag or equivalent as peeroved)
S&F in repairs chromium plated fancy type bib tap 15mm complete at any position etc complete all as specified and as directed.
S&F in repairs 15mm size Stop Valves fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends etc complete all as specified and as directed .
M&L for low density polythene pipes (LDPE) of pressure rating 6 Kgf/Sqcm outer dia of pipe 40 mm fixed in waste pipe and water closet in repairs all as specified and directed .
M&L for hardcore with broken stone or boulders of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified and directed.
M&L 100 mm thick cement concrete type C-2, 1:3:6 using 40 mm graded stone aggregate as sub base.
M&L Machine pressed precast conctete interlocking paver block rubber moulded, any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment over and including 50mm thick crushed stone sand filling complete all as specified and as directed.
M&L for cement concrete as in road kerbs or copings and the like of Type B1, 1:2:4 (using 20mm graded stone aggregate) round or chamfered on edge including necessary use and waste of formwork.
Removing excavated material outside MD land to a distance exceeding 1.5 Km but not exceeding 5Km and deposited where directed as in soil.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out soft loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed.
M&L Cement concrete Type C-2 1:3:6 (using 40mm graded stone aggregates) in foundations, filling and mass concrete all as specified and as directed.
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240 complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, fan socket or power ) point complete, including fixtures and fittings such as switches, ceiling rose, pendents, regulators, ceilling fan, Exhaust fan,sockets, tube light fitting,main switch,MCB and DB's etc complete all as specified and directed.
Material and labour for point wiring, in repairs complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked, conforming to IS-694/1990 unsheathed, concealed wiring multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC conduit size not less than 25 mm dia medium grade such as Tee, Corner, overlaping connector etc. along the concealed in walls/roofs/ ceilings/floors etc including concealed PVC box for fixing of and including modular plate as per no of switch modules flush mounted suitable for fixing modular switches, sockets, fan regulators etc. including modular plate cover of required size with necessary stainless steel cadmium plated screws and including 1.5 Sqmm PVC insulated, multistranded, FRLS type,unsheathed (Green colour), single core, copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed for One light point/ Fan Point controlled by one switch.
Material and labour for point wiring, in repairs complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, concealed wiring multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC conduit size not less than 25 mm dia medium grade such as Tee ,Corner, overlaping connector etc.along the concealed in walls/roofs/ ceilings/floors etc including concealed PVC box for fixing of and including modular plate as per no of switch modules flush mounted suitable for fixing modular switches , sockets,fan regulators etc. including modular plate cover of required size with necessary stainless steel cadmium plated screws and including 1.5 Sqmm PVC insulated, multistranded, FRLS type,unsheathed (Green colour),single core, copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed for One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
Material and labour for point wiring, in repairs complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, concealed wiring multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC conduit size not less than 25 mm dia medium grade such as Tee ,Corner, overlaping connector etc.along the concealed in walls/roofs/ ceilings/floors etc including concealed PVC box for fixing of and including modular plate as per no of switch modules flush mounted suitable for fixing modular switches , sockets,fan regulators etc. including modular plate cover of required size with necessary stainless steel cadmium plated screws and including 1.5 Sqmm PVC insulated, multistranded, FRLS type,unsheathed (Green colour),single core, copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed for One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
Material and labour for point wiring, in repairs complete with 2.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, concealed wiring multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC conduit size not less than 25 mm dia medium grade such as Tee ,Corner, overlaping connector etc.along the concealed in walls/roofs/ ceilings/floors etc including concealed PVC box for fixing of and including modular plate as per no of switch modules flush mounted suitable for fixing modular switches , sockets,fan regulators etc. including modular plate cover of required size with necessary stainless steel cadmium plated screws and including 1.5 Sqmm PVC insulated, multistranded, FRLS type,unsheathed (Green colour),single core, copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed for One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board.
Supply & fixing modular type switch 6 Amps ,1way,1 module.
Supply & fixing modular type switch 16 Amps ,1way,1 module .
Supply & fixing modular type socket 6 Amps, 2/3 Pin combined 2 module .
Supply & fixing modular type socket 6 A/16 Amps, 6 Pin combined 2 module.
Supply & fix ceiling rose, 3 terminal, PVC/polycarbonate body
Supply &fix modular type fan regulator stepped type 120 W- 2 module.
Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. with suitable size of GI bracket and clamp for wall fixing.
Supply & fix in repair recess mounting high lumen LED slim panel 2'X2' 36Watt, white powder coated CRCA housing with highpower LEDs , aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver,LED strip,connector block etc.and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and directed.
Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip 25 x 4 mm size by means of bolts, nuts, check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) and RCC 1:2:4, type B1 (using 20 mm graded stone aggregate) for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing of earthing on completion complete all as specified & directed. Note:- Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length.
Supply and fix sheet metal enclosure with two pin and earth plug and socket including MCB SP 20 Amp,10KA,'C' series inlcuding removing old unserviceable item complete all as specified and directed. .
Material and labour for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC conduit of size not less than 25mm dia above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed concealed in walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable item complete all as specified and directed. Note : - 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC conduit shall be measured as one unit.
Taking down and refixing of ceiling fan 1200 mm sweep to 1400 mm sweep of any make from its existing position after disconnecting of electric connection for carrying out repairs including servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent including renewal of spare parts such as split pins, cater pins, coupling bolt, capacitor, holder, terminal adoptor, screws, nuts and washers etc and replacement of spare parts/accessories such as ball bearings, gun metal bushes, capacitor, canopy top and bottom, shackle clip assembly, rewinding of fan motor, painting and including hanging/ fixing back in existing location and making cable connections and testing for its satisfactory performance complete all as specified and directed.
Taking down and refixing of exhaust fans 250 mm sweep to 300 mm sweep of any make from any height after disconnecting of electric connection for carrying out repairs including servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent and renewal of spare parts such as split pins,cater pins, capacitor holder, terminal adoptor, nuts, bolts and washers etc and replacement of components/accessories such as ball bearings, gun metal bushes, capacitor, rewinding of fan motor including fixing back in existing location and making cable connections and testing for its satisfactory performance complete all as specified and directed.
Taking down and refixing of ceiling fan 1200 mm sweep to 1400 mm sweep of any make from its existing position after disconnecting of electric connection for carrying out repairs including servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent including renewal of spare parts such as split pins, cater pins, coupling bolt, capacitor, holder, terminal adoptor, screws, nuts and washers etc and replacement of spare parts/accessories such as ball bearings, gun metal bushes, capacitor, canopy top and bottom, shackle clip assembly, painting and including hanging/ fixing back in existing location and making cable connections and testing for its satisfactory performance complete all as specified and directed.
Supply and fix copper conductor cable 3 core; 1.5 sqmm, PVC insulated, sheathed, flexible, multistranded,1100 volts grade for making connection to ceiling fan from ceiling rose complete all as specified and directed
AKANKSHA CONSTRUCTION
Harsh Infrastructure
KML CONSTRUCTION
Nakshatra Enterprises
Nilesh Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .