Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC GURDASPUR ROAD OPP WAREHOUSE PATHANKOT 145 001 PB | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹32.0 L+₹1.3 L (4.38%)Rejected-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹33.3 L+₹2.7 L (8.83%)Rejected-AOC POST BOX NO 477 JUNGLIGHAT POST SRI VIJAYA PURAM SOUTH ANDAMAN 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹35.8 L+₹5.2 L (17.0%)Rejected-AOC BIRD LINE CALICUT POST SRI VIJAYA PURAM SOUTH ANDAMAN 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹37.0 L+₹6.3 L (20.7%)Rejected-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L5 | Rejected-AOC Being not L1 |
Tender Value
₹40.7 L
EMD Value
₹81,400
Closing Date
28 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander works Engineer
Commander Works Engineer Military Engineer Services Junlighat post Minniebay Port Blair 744103
80994 PROVISION OF HT RMU PANEL AND ALLIED WORKS AT CG TRV SUBSTATION UNDER GE HADDO PORT BLAIR
2022_MES_553635_1
80994 PRVN OF HT RMU PANEL GE HADDO
Open Tender
Civil Works - Others
Item Rate
180 days
Port Blair
Class D b ii
8 documents required · 8 mandatory
₹500
GE Haddo
₹81,400
Yes
2 Feb 2023
22 Sept 2022
3 Nov 2022
22 Sept 2022
28 Oct 2022
10 Oct 2022
Amount
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 Sq mm complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 185 Sq mm complete all as specified and directed.
Supply, laying cable in trenches, walls, structure LT UG cable XLPE insulated screened PVC sheathed bedded galvanised strip armoured electric cable heavy duty 1100 volts with standard aluminium conductor of 3.5 core 300 Sq mm size including taking down existing cables complete all as specified and directed.
Supply, laying cable in trenches, walls, structure LT UG cable XLPE insulated screened PVC sheathed bedded galvanised strip armoured electric cable heavy duty 1100 volts with standard aluminium conductor of 3.5 core x 240 Sq mm size including taking down existing cables complete all as specified and directed.
Supply, laying cable in trenches, walls, structure LT UG cable XLPE insulated screened PVC sheathed bedded galvanised strip armoured electric cable heavy duty 1100 volts with standard aluminium conductor of 3.5 core x 120 Sq mm size including taking down existing cables complete all as specified and directed. Note for Item 3 to 5 : Old retrieved cable to be deposited to MES store yard.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, AIuminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, AIuminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, AIuminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
Supply, installation, testing and commissioning of 11KV HT RMU panel 4 ways (01 No for incoming and 03 Nos for outgoing), extendible HT 11 KV outdoor type 21KA for 3 sec, rated voltage-12KV, operation voltage 11 KV, rated lightening withstand voltage-75KV, rated frequency 50Hz, 630 Amps copper bus bar, SF6 insulated compact switch gear, welded stainless steel enclosure with minimum 2.5mm thickness, totally enclosed Ring Main Unit IP-67 protection for SF-6 Tank and IP 55 protection for outdoor enclosure with self powered microprocessor based complete numerical over current & earth fault relay with specification / requirement with power backup 24 volts DC including interlocking system for incoming VCBs complete with all accessories comprising of following (VVVV+M configuration):- (Item No.9.00 Contd.../-)
(Item No.9.00 Contd.../-) (a) Fixed Vaccum circuit breaker (VCB), SF6 gas insulated-01 (One) No Vaccum circuit breaker unit as incomer, insulated in SF6 media as per latest IEC 62271-200 shall be comprising of the following for each set :- (i) Assembly of VCB interrupter complete with epoxy support insulator and self aligning isolating contacts with rating 11 KV, 630 Amp, 21 KA for 3 sec, 50 Hz. (ii) Manual charged and manual operated independent closing /triping, trip free operating mechanism and breaker closed/ open spring charged/ discharge indication. (iii) Mechanical operation counter - 01 No. (iv) One bus bar chamber including a set of three phase 630 Amps copper bus bar. (v) Strip heater 230 Volts AC single phase 80 watt. (vi) 3 0/C + 1 E/F self powered numerical protection relay with low and high set for over current and earth fault. Relay should have facility to display the maxim loaded phase current also. Relay shall record minimum 5 fault record with time stamping. (vii) Auxiliary Transformer relays and master trip relay. (Item 9.00 Contd.../-)
(Item No.9.00 Contd.../-) (viii) One No potential transformer (PT) three phase, dry type (resin cast) fixed type 11 KV/110 VOLTS, 25 VA burden, accuracy class 0.5 with HT. (ix) Current transformer chamber comprising of 3 Nos single phase resin cast CT of 100-50/5 and accuracy class 0.5 for metering and class 5P 1C for protection, burden 2.5 VA in VCB feeder - each set of all VCBs. (x) Multifunction meter indicating line/phase current, line/phase voltage, power factor , KVAR, KVA, frequency, maximum demand in KVA, maximum demand in KWH etc with accuracy class 0.5 - 01 No (for incoming VCB). (Item No.9.00 Contd.../-)
(b) Vaccum circuit breaker (VCB), SF6 gas insulated-03 Nos Vaccum circuit breaker unit insulated as outgoing in SF6 media as per latest IEC 62271-200 shall be comprising of the follwong for each set :- (i) Assembly of VCB interrupter complete with epoxy support insulator and self aligning isolating contracts with rating 11 KV, 630 Amp, 21 KA for 3 sec, 50 Hz. (ii) Manual charged and manual operated independent closing/tripping, trip free operating mechanism and breaker closed/open spring charged/discharge indication. (iii) Mechanical operation counter-01 No. (iv) One bus bar chamber including a set of 3 phase 630 Amps copper bus bar. (v) Strip heater 230 volts AC single phase 80 watt. (vi) 3 0/C + 1 E/F self powered numerical protection relay with low and high set for over current and earth fault. Relay should have facility to display the maxim loaded phase current also. Relay shall record minimum 5 fault record with time stamping. (vii) Auxiliary Transformer relays and master trip relay. (viii) One No potential transformer (PT) three phase, dry type (resin cast) fixed type 11 KV/110 volts, 25 VA burden, accuracy class 0.5 with HT. (ix) Current transformer chamber comprising of 3 Nos single phase resin cast CTs of 100-50/5 and accuracy class 0.5 for metering and class 5P 10 for protection, burden 2.5 VA in VCB feeder - each set of all VCBs. (x) Multifunction meter indicating line/phase current, line/phase voltage, power factor , KVAR, KVA, frequency, etc with accuracy class 0.5 - 3 Nos (for 03 outgoing VCBs)
(Item No.9.00 Contd.../-) Make for RMU :- Lucy Electric India Pvt Ltd./ABB/Schneider/L&T/C&S Electricals/Voltech System & Switchgear NOTE:- (i) The RMU shall be tested for high voltage Primary Injection test and second injection test individually at site after erection before commissioning and the same is deemed to be to included in the qouted rate.
Excavation in trenches n.exc 1.5 mtrs wide and not exc 1.5 M deep in soft/loose soil and getting out all as specified and as directed.
Returning, filling in including spreading, levelling and well ramming in layers not exc 25cm in soft / loose soil all as specified and directed.
Removing excavated soil to a distance not exc 50 M and depositing where directed at level not exc 1.5 m above starting point all as specified and as directed.
Supply and laying in trenches or in cable ducts, HDPE DWC pipe of size 120 mm (OD) X 103.5 mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT/HT cable protection complete all as specified and as directed by Engineer-in-Charge.
Supply and laying HDPE DWC pipe of size 77 mm (OD) x 63 mm (ID) along with connected accessories like couplers, bends, end caps etc., for LT cable protection complete all as specified and as directed by Engineer-in-Charge.
M & L, earthing complete with GI plate electrode of size 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below the normal ground level) with top edge of plate not less than 1.5 m below normal ground level connected to GI strip 32 X 6 mm as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No.5 of SSR Part-I connected to main board/distribution board complete all as specified and directed. Note :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC M-25 (design mix) cover 50 mm thick reinforced with 8 mm dia CTD bars @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe medium grade 40mm dia and wire mesh complete in addition to item No.1(a) to (e) of preamble (notes) under sub-heading earthing, specified on SI. Page No.347 of SSR Part-II.
Prasur Electricals & Engineering Co.
SWASTHIK ENTERPRISES
DELTA ELECTRICALS
vijay kumar gupta and co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .