Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹46.2 L
EMD Value
₹92,500
Closing Date
6 Aug 2020, 6:00 pmClosed
MR ARJUN PATRO
GE U ELECTRIC SUPPLY DELHI CANTT-10
Repair replacement and maintenance of LT Panel LT Poles earthing capacitor bank and connected works of Tigris MAP Sumran Line MAP Shekhawati Line Aahwan Sanyat Line Hazipeer Line NPG Line Maude Line Panchwati DAD NSB III CASD 60 Bde 20 Punjab 255 Tra
2020_MES_356033_1
GE ELECT/D-39/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹92,500
Yes
11 Aug 2020
17 Jul 2020
8 Aug 2020
18 Jul 2020
6 Aug 2020
1 Aug 2020
Amount
OUTGOINGS:- (i) MCCB 4 pole, 400 Amps, 50 Hz, 415 Volts, 36 KA microprocessor release - 1 Nos (ii) MCCB 4 pole, 250 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermo and Magnetic release - 1 No (iii) MCCB 4 pole, 100 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermo and Magnetic release - 2 No Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note : (i) Location : DAPS sub stn, Sanyat line, 406 Lt AD, 255 sub stn, 6 Engr Regt. (ii) Location cantnot be changed without permission of GE, approval of GE is mandetory for any changing in Location
(b) Outgoing :-(i) MCCB 4 pole, 250 Amps, Thermal megnatic release, 50 Hz, 415 Volts, 36 KA - 01 Nos. (ii) MCCB 4 pole, 100 Amps, Thermal megnatic release 50 Hz, 415 Volts,36 kA - 3 No Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note:(i) Location : Offrs Mess 60 Bde, JCO Mess 255 TC, Near CO office 218 Med, Mandir 147 Fd Wksp, ECHS back side 147. (ii) Location cantnot be changed without permission of GE, approval of GE is mandetory for any changing in Location
Outgoing :- (i) MCCB 4 pole, 100 Amps, Thermal magetic release, 50 Hz, 415 Volts, 36 KA -2 Nos. (ii) MCCB 4 pole, 63 Amps, Thermal magetic release, 50 Hz, 415 Volts, 36 KA - 2 Nos. Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note : (i) Location : 6 Engr Regt, MT 629 TPT, 15 Grenadiers offrs mess, Office area (ii) Location cantnot be changed without permission of GE, approval of GE is mandetory for any changing in Location
Outgoing :- (i) MCCB 4 pole, 100 Amps, Thermal magetic release, 50 Hz, 415 Volts, 36 KA -1 Nos. (ii) MCCB 4 pole, 63 Amps, Thermal magetic release, 50 Hz, 415 Volts, 36 KA - 2 Nos. (iii) Onload Change over switch disconnectors, motorised open execution, 125 A - 01 Nos Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Note: (i) Location : Main office 20 Pb, JCO Mess 20 Pb, Offrs Mess 20 Pb, ORs Instechuite 20 Pb, Main office 629 TPT, AAWAHAN (ii) Location cantnot be changed without permission of GE, approval of GE is mandetory for any changing in Location
Material and Labour for disconnecting burnt end or portion of cable removing the cable from loop including necessary excavation & earth work in soft/loose soil relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals including fixing of new lugs for 50 Sqmm 3½ / 4 to 400 Sqmm of LT cable to pole / main switch including taping of XLPE cables complete all as specified and directed.
Material and labour in replacement of Voltmeter 0-500 V digital type as per existing size complete all as per specified and directed.
Material and labour in replacement of Ammeter 0-400/800 Amp digital type per existing size complete all as per specified and directed
Supply and fixing in replacement of indicator lamp for RYB phases complete all as specified and directed.
Earthing complete in replacement with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in soft/loose soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in soft/loose Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply & fixing in replacement of Air circuit breaker 4 pole ET6G Trip System, Masterpact mvs08N, UI 1000V, Uimp 12 kV ICW-50 kAawout Adjustable type including dismantling & taking out old unserviceable ACB from panels & fabrication works to BUS bar for proper fitting . Make: Schneider electric.
S&F (in replacement) capacitor capacity 5 KVAR complete with all electric connection complete all as specified and directed.
S&F (in replacement) capacitor capacity 10 KVAR complete with all electric connection complete all as specified and directed.
S&F (in replacement) capacitor capacity 25 KVAR complete with all electric connection complete all as specified and directed.
S&F (in replacement) capacitor capacity 50 KVAR complete with all electric connection complete all as specified and directed.
Supply and fixing MCCB 4 pole 100 Amps rupturing capacity 16 KA on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 160 Amps rupturing capacity 16 KA on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 200 Amps rupturing capacity 25 KA on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 250 Amps rupturing capacity 25 KA on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 315 Amps rupturing capacity 36 KA on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 400 Amps rupturing capacity 36 KA on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 630 Amps rupturing capacity 50 KA on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Material and labour for painting of LT panel boards out door/in door of size up to 3.00 Sqm floor mounted installed at different locations including preparation of exposed surface by removing old paint from the body, cleaning the surface with thinner and applying two coats of synthetic enamelled smoke grey paint complete all as specified and directed.
Material and labour for painting of LT panel boards out door/in door of size above 3.00 Sqmm and up to 10 Sqmm floor mounted installed at different locations including preparation of exposed surface by removing old paint from the body, cleaning the surface with thinner and applying two coats of synthetic enamelled smoke grey paint complete all as specified and directed.
M&L for painting with two coats of superior aluminium paint including necessary preparation of surfaces of steel fencing by brushing/cleaning complete steel structure/frame/ gate for 11 KV transformer/2 pole to 8 pole structure/ HT & LT panels/Sub Station up to 20 Sqmm arera complete all as specified and directed.
M&L for painting with two coat of superior aluminium paint including necessary preparation of surfaces of steel fencing by brushing/cleaning complete steel structure/frame/ gate for 11 KV transformer/2 pole to 8 pole structure/ HT & LT panels/Sub Station above 20 Sqmm arera complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel/feeder pilar up to 50 Sqmm cable complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel/feeder pilar for 70 sqmm cable to 240 Sqmm cable complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel for 300 sqmm cable to 400 Sqmm cable complete all as specified and directed.
Supply and fixing in replacement of galvanised iron strip 32 X 6 mm for additional earthing lead beyond 7.5 meter.
M & L for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel/Four Pole structure/Sub Stations and removing all rubbish to a distance not exceeding 50 m as directed.
Material and labour for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) complete all as specified and directed by Engr in charge.
Material and labour for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) including necessary form work and finished the surface complete all as specified and directed.
Supply & fixing of SMC Junction box for street light having side hinged, outside dimention 333x233x120mm and inside dimention 300x200x105mm including 4 Nos aluminium bus bar of 63 Amps rating and connecting of existing LT power cable complete all as directed.
Supplying & Errecting in replacement of PCC pole to Steel Tubular Pole in 410 SP-31 (9 metres long) complete with cast iron base plate, finial taper plug, nuts, bolts and washers all as specified in IS including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 m from the starting points. (b) Providing PCC (1: 4:8) type D-2 using 40 mm graded stone aggregate as in foundations up to ground level all as specified and directed. (c) Providing PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including necessary form work for plinth block/collar above GL all as specified and directed. (d) Providing PCC (1:2:4) type B-2 using 20 mm graded stone aggregate as in coping including necessary form work all as specified and directed. (e) Painting of Poles with one coat of red oxide primer and one coat of aluminum paint before fixing and one coat of aluminum paint after fixing. The complete embedded portion shall be painted with two coats of black bituminus paint.
Preparation of old painted surfaces of Steel tubular LT/HT poles, any height including cross arms, MS strap, nuts, bolts, washers, cable protection pipe wherever provided etc and painting of complete poles with one coat of aluminium paint from 2.1 m above ground level to top of pole including cross arms and protection pipe and painting of bottom area of pole upto 2.1 m from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including writing pole numbers in white letter of approved size on black ground complete all as specified and directed.
Preparation of old painted surfaces of LT/HT PCC poles for cross arms, MS strap, nuts, bolts, washers, cable protection pipe wherever provided etc and painting with one coat of aluminium paint and painting of bottom area of pole upto 2.1 m from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including writing pole numbers in white letter of approved size on black ground complete all as specified and directed.
Supply, Laying jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, cross sectional area 10 Sqmm 2 Core PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed.
All as per item No 39 above but cross sectional area 16 Sqmm 4 core.
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified. Note : Measurement shall be taken after punning down.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Returning filling in,. Including spreading, levelling, Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 50 to 100 mm bore and making good both ends all specified and directed
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore of sizes 100 mm bore.
All as per item No 47 but size 50mm
Supply and fix (in replacement) 8 stage APFC relay
Supply and fix (in replacement) 5 stage relay
Supply and fix (in replacement) contractor mnx 45
Supply and fix (in replacement) contractor mnx 70
Supply and fix (in replacement) LED indicator lamp
Supply and fix (in replacement) push buttorn
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
M/s Adhikari construction co.
Rajindera Enterprises
MV Engineers And Contractors
M/s Sohanil Construction
Vijay Electricals
ALLIED CONSTRUCTION
Buddham Builders
Ridhi engineers and builders
M/s Birja Nand
DS CONSTRUCTION
M/s ELECTROSHINE ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .