Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹36.0 L+₹1.1 L (3.21%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹36.7 L+₹1.8 L (5.28%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹36.8 L+₹1.9 L (5.53%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹37.1 L+₹2.2 L (6.25%)Rejected-AOC N A | NEW DELHI | DELHI | 110001 | L5 | Rejected-AOC Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
2 Jan 2025, 6:00 pmClosed
GE GOMANTAK
GE Gomantak Vasco Da Gama Pin 403802
Repair Replacement of overhead tank including cleaning and marking at Zone A and Zone B and Repair maintenance to footpath drain culvert and Misc works under AGE BR II in GE Gomantak Vasco
2024_MES_686904_1
8678/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
VASCO DA GAMA
As per tender documents
8 documents required · 8 mandatory
₹500
GE GOMANTAK
₹70,000
Yes
12 Mar 2025
4 Dec 2024
4 Jan 2025
4 Dec 2024
2 Jan 2025
19 Dec 2024
Amount
Demolition of cement concrete unreinforced in ground floors and pavings n.exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed.
Cleaning and removing all scale and dirt, etc. using bleaching powder and from mouths of circulating pipes from tanks of 500 Ltr capacity including removing stored water writing TANK CLEANED ON _______ (Date) complete all as specified and directed.
Cleaning and removing all scale and dirt, etc. using bleaching powder and from mouths of circulating pipes from tanks of 1000 Ltr capacity including removing stored water writing TANK CLEANED ON _______ (Date) complete all as specified and directed.
Disconnecting existing water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside (or lowering of required) for repairs, cleaning etc. and hoisting, reconnecting and refixing in position on roof complete all as specified and directed.
Disconnecting existing water tank of capacity exc. 500 ltr but not exc. 1000 ltr, setting aside (or lowering of required) for repairs, cleaning etc. and hoisting, reconnecting and refixing in position on roof complete all as specified and directed.
Dismantling water tank capacity exc. 500 ltr but n.exc. 1000 ltr complete all as specified and directed.
Dismantling water tank capacity exc. 250 ltr but n.exc. 500 ltr complete all as specified and directed.
S&F Rotational moulded Polyethylene (HDPE) Water Storage Tank 1000 Litre Capacity (Cylindrical Vertical with Closed Top), hoisted and fixed in Position all specified in MES Schedule Part-I, fixed complete all as specified and directed.
S&F Rotational moulded Polyethylene (HDPE) Water Storage Tank 500 Litre Capacity (Cylindrical Vertical with Closed Top), hoisted and fixed in Position all specified in MES Schedule Part-I, fixed complete all as specified and directed.
Taking up or down existing GI tubing and connections, including making good the disturbed surface for 20 mm dia pipes complete all as specified and directed.
Taking up or down existing GI tubing and connections, including making good the disturbed surface for 25 mm dia pipes complete all as specified and directed.
Refixing old 20 mm dia steel tubing in walls, ceilling, floors etc.and connection in new or old positions including new or old fittings and cleaning of old pipe (walls, ceilling, floors etc.) complete all as specified and directed.
Refixing old 25 mm dia steel tubing in walls, ceilling, floors etc.and connection in new or old positions including new or old fittings and cleaning of old pipe (walls, ceilling, floors etc.) complete all as specified and directed.
Supply, fixing, laying & testing CPVC pipes 20 mm SDR 11 including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Supply, fixing, laying & testing CPVC pipes 25 mm SDR 11 including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S&F in repairs 20 mm diameter Ball brass valves high pressure with polythene float screwed for iron pipe or brass ferrule and fixed as specified.
S&F in repairs 25 mm diameter Ball brass valves high pressure with polythene float screwed for iron pipe or brass ferrule and fixed as specified.
S&F in repair 10 Ltrs capacity, PVC valveless, syphonic action type, low level flushing cistern moulded from virgin poly propylene, white, with inlet, ball valve, float and handle complete with all internal accessories and fixed to wall complete all as specified and directed.
S&F in repair PVC (SWR) pipes 110 mm single socketed in any length with rubber ring joints fixed to walls or in floors in clean or foul condition including clamps complete all as specified and directed.
S&F in repair PVC (SWR) bends 110 mm bore any radius with rubber ring complete all as specified and directed.
S&F in repair 20 mm bore gun metal gate or globe valve with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F in repair 25 mm bore gun metal gate or globe valve with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F in repair PVC tank cover with locking arrangement for 500/1000 ltrs water tank complete all as specified and directed.
S&F in repair PVC tank cover with locking arrangement for 250/300 ltrs water tank complete all as specified and directed.
Demolition of Brick Work/ stone work / concrete block wall built in Cement Mortar including all quoins, arches, pillars, etc. of any descriptions, complete all as specified and as directed.
M&L for precast cement concrete block masonry, type C-1 (1:3:6) (20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in CM 1:4 complete all as specified and as directed.
All as per item No. 27 but except blocks Note:- Old blocks retrieved from item No. 26 shall be reused
M&L for Cement concrete concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping etc. including necessary form work complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
Add or deduct to Item No. 31 above for each 25 mm girth or part thereof over or under 30cm.
Taking down cement plaster on walls/ceiling of any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work/ block masonary or concrete surfaces in cement mortar 1:4 finished even and fair complete all as specified and directed.
M&L for applying three coats of white wash on wall including preparation of new surface complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/dense soil for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out complete all as specified and as directed.
Removing excavated material (Soils/Rock) to a distance exceeding 250 m but not exceeding 500 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
M&L for fixing in repair 300 mm bore reinforced concrete pipes, class NP3, complete with collars, laid and jointed in cement mortar 1:1 as in drains and similar works complete all as specified and directed.
M&L for fixing in repair 600 mm bore reinforced concrete pipes, class NP3, complete with collars, laid and jointed in cement mortar 1:1 as in drains and similar works complete all as specified and directed.
M&L for 75 mm thick cement concrete type C-1 1:3:6 (using 20 mm stone graded crushed stone aggregate) as in plinth protection surface finished even and smooth without using extra cement including forming construction (dummy) joints 6 mm wide & 10 mm deep and filled with filler at an interval not exceeding 3 metre and at change of direction and necessary formwork complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in saucer drain and the like slightly rounded or chamfered angles, depth of saucer drain upto 45 cm, thickness minimum 50 mm and width of drain min 25-30 cm all as required at site to ease flow of rain water and flow of water from damping ground area to the nearest area including necessary earthwork, form work and demolition of old concrete surface/ road surface complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for reinforced precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs ( for manholes etc.) and similar articles with plain faces including necessary form work, set in cement mortar 1:4 complete all as specified and directed. (Reinforcement shall be measured and paid for separately under respective item of Schedule 'A').
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Demolition of un reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as kerb stone, PCC block for footpath including necessary formwork complete all as specified and directed.
M&L for preparation of new or previously untreated plastered surfaces or concrete surface exceeding 10 cm width or girth and applying two coats of synthetic enamel paint in two different colour over a coat priming paint complete all as specified and directed.
M&L for preparation of old painted plastered surfaces or concrete surface exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Hardcore of broken stone or boulder gauge n. exc. 63 mm, deposited, spread & levelled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) 75 mm thick as in sub base, finishing the surface even and rough to receive floor complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:2:4 type B-2 using 40 mm graded stone aggregate as in floor/ hard standing finished fair and even including necessary formwork and strip to divide the area into panels complete all as specified and directed.
M&L for 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping etc. including necessary form work complete all as specified and directed.
M&L for machine pressed rubber moulded coloured chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, with grey pigment cement and pigment, set, jointed and pointed in neat cement slurry in floors with & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
M&L for preparation of old painted concrete/tile/floor/MP roof tiles surfaces and applying one or more coats of tile guard paint of premium quality complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
S&F rolled mild steel in framed work as in doors or gates (Ornamental type where required) of angle or other section with gusset plates, rails, braces etc., complete, drilled for fixing of steel sheeting or other covering doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Removing building materials by truck or tractor with using of if necessary JCB machine and trolly including loading, unloading and stacking at the destination and depositing out side defence land complete all as specified and directed.
Leela Enterprises (BID ID -3196799)
CVS CONSTRUCTIONS (BID ID -3198741)
SHIVRAJ CONSTRUCTIONS (BID ID -3199256)
Deepti Engineering Works (BID ID -3196982)
STAR FABRICATION (BID ID -3198054)
M/S jvsr constructions (BID ID -3198814)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .