Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | LI₹38.5 LAccepted-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | LI | Accepted-AOC BEING L1 | |
| 2 | L2₹39.7 LRejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹40.4 LRejected-Finance 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹41.7 LRejected-Finance 88 197 B CHAMAN GANJ KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹42.2 LRejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹87,680
Closing Date
15 Nov 2024, 6:00 pmClosed
GE (AF) UDHAMPUR
GE (AF) STN UDHAMPUR
GE/AFU-45/2024-25 SPECIAL REPAIR TO LT PANEL FEEDER PILLAR BOXES ALONGWITH CERTAIN E/M WORK AT 901 SU AF STN NATHATOP UNDER GE (AF) UDHAMPUR
2024_MES_680206_1
GE/AFU-45/2024-25
Open Tender
Civil Works
Works
270 days
GE (AF) STN UDHAMPUR
GE/AFU-45/2024-25 SPECIAL REPAIR TO LT PANEL FEEDER PILLAR BOXES ALONGWITH CERTAIN E/M WORK AT 901 SU AF STN NATHATOP UNDER GE (AF) UDHAMPUR
8 documents required · 8 mandatory
₹500
GE (AF) UDHAMPUR
₹87,680
12 Dec 2024
18 Oct 2024
18 Nov 2024
18 Oct 2024
15 Nov 2024
1 Nov 2024
18 Oct 2024 - 25 Oct 2024
Amount
Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA SHEET & suitable frame work/ support made out of MS Section of size 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete with color coded & Suitable tag and PCC (1:3:6) type C-2 foundation of size including connections of all out going/in coming existing cables of any size by drawing /digging out cable inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size of copper lugs for terminal connections of cables, where as necessary and taking out of old skelton type panel with control switches complete all as specified and as directed by Engr-in-Charge. including the following items incorporated in the same panel and removed old unserviceable panel.The scope of work also comprising of the following:-
BUS BAR CHAMBER :- (a) 400 Amp insulated copper bus bar of length not less than 60 cm, 03 phase and neutral, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER :- (i) Multi function meter - 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-250A, with Amp meter push button type- 01 Set. (iii) C.T's 250/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)(iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).B8Make of Metering Accessories :-L&T/ AE/ Schneider. INCOMING SUPPLY :- (i) MCCB 250 Amps 25 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50 Hz,=01 OUTGOING SUPPLY :- (i) MCCB 100 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos.,(ii) MCCB 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos.,(ii) MCB TPN 40 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos. (iv) Astroncmical timer switch for security light -01 Set Make of MCCB:-L&T/ Siemens / Legrand/Havells The panel manufacturer should have CPRI certified 1. Panel shall be installed at least 45 cm above ground . 2. All civil/electrical work & material is deemed to be included in the quoted rates. 3. Drawing of panel shall be got approved from GE.
Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA SHEET & suitable frame work/ support made out of MS Section of size 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete and PCC (1:3:6) type C-2 foundation of size including connections of all out going/in coming existing cables of any size by drawing /digging out cable inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size of copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board and taking out of old skelton type panel with control switches complete all as specified and as directed by Engr-in-Charge. including the following items incorporated same panel and removed old unserviceable panel.The scope of work also comprising of the following:-
BUS BAR CHAMBER :- (a) 400 Amp insulated copper bus bar of length not less than 60 cm , 03 phase and neutral, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Multi function meter - 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-250A, with Amp meter push button type- 01 Set. (iii) C.T's 250/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).B8 Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider.
Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 400 Amps 25 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50 Hz,=01 OUTGOING SUPPLY :- (i) MCCB 150 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., (ii) MCCB 100 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., (ii) MCCB 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos. (iv) MCB TPN-40Amps -02 (v) Timer switch for security light - 01 Set Make of MCCB:-L&T/ Siemens / Legrand /Havells The panel manufacturer should have Govt. Approved Certificates: 1. Panel shall be installed at least 45 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates
3. Drawing of panel shall be got approved from GE. :- (i) MCCB 400 Amps 25 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50 Hz,=01 OUTGOING SUPPLY :- (i) MCCB 150 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., (ii) MCCB 100 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., (ii) MCCB 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos. (iv) MCB TPN-40Amps -02 (v) Timer switch for security light - 01 Set Make of MCCB:-L&T/ Siemens / Legrand /Havells The panel manufacturer should have Govt. Approved Certificates: 1. Panel shall be installed at least 45 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE.
Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA SHEET & suitable frame work/ support made out of MS Section of size 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete and PCC (1:3:6) type C-2 foundation of size including connections of all out going/in coming existing cables of any size by drawing /digging out cable inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size of copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board and taking out of old skelton type panel with control switches complete all as specified and as directed by Engr-in-Charge. including the following items incorporated same panel and removed old unserviceable panel.The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 600 Amp insulated copper busbar of length not less than 60 cm,03 phase and neutral, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.
INSTRUMENT CHAMBER :- (i) Multi function meter - 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-250A, with Amp meter push button type- 01 Set. (iii) C.T's 250/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).B8 Make of Metering Accessories :-L&T/ AE/ Schneider. INCOMING SUPPLY :- (i) MCCB 400 Amps 25 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50 Hz,=01 OUTGOING SUPPLY :- (i) MCCB 200 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=01 Nos., (ii) MCCB 100 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=03 Nos., (ii) MCCB 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=01 Nos. Make of MCCB:-L&T/ Siemens / Legrand/Havells The panel manufacturer should have Govt. Approved Certificates: 1. Panel shall be installed at least 45 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE.
Supply and fixing testing and commissioning outdoor type LT cubical panel Factory fabricated CRCA Sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 3.15 mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 400 Amp duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched/tied, ferruled for proper identification and crimpled with adequate size of lugs. BUS BAR CHAMBER :- (a) 400 Amp insulated copper busbar of length not less than 60 cm,03 phase and neutral, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.
INSTRUMENT CHAMBER :- (i) Multi function meter - 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-250A, with Amp meter push button type- 01 Set. (iii) C.T's 250/5 A CL 1.0 Tape Wound- 01 Set. (Set of three). (iv) Red,Yellow,Green Phase indicating Lights LED type220 Vot - 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Schneider. INCOMING SUPPLY :- (i) MCCB 125 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=01 Nos., (ii) MCCB 100 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., (ii) MCB TPN 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=01 Nos. (ii) MCB SPN 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=01 Nos. (iv) Astroncmical timer switch for security light -01 Set OUTGOING SUPPLY :- (ii) MCB TPN 40 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=03 Nos. (iv) Anlog timer switch for security light -01 Set, Make of MCCB:-L&T/ Siemens / Legrand/Havells The panel manufacturer should have Govt. Approved Certificates: 1. Panel shall be installed at least 45 cm above ground. 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE.
Supply and fixing of testing and commissioning outdoor type LT cubical panel Factory fabricated CRCA Sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 3.15 mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 400 Amp duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched/tied, ferruled for proper identification and crimpled with adequate size of lugs. The coubical will have a support of angle size 50x50x5 mm &04Nos duly Grouted 30cm below the GL in pcc including a detachable pre-drillind gland plate of thickness 3.15 mm the auxillary support of suitable spd Protactived shall provided. INSTRUMENT CHAMBER :- (i) Multi function meter - 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-250A, with Amp meter push button type- 01 Set. (iii) C.T's 250/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).B8 Make of Metering Accessories :-L&T/ AE/ Schneider.
INCOMING SUPPLY :- (i) MCCB 250 Amps 25 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50 Hz,=01 (ii)Copper Busbar 4 pole (three phase and one for neutral) suitable 400 Amps . (III) Anlog timer switch for security light -01 Set OUT GOING SUPPLY :- (i) MCCB 200 Amps 25 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50 Hz,=01 (ii) MCCB 100 Amps 25 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50 Hz,=01 (iii) MCB TPN 40 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos. (v) MCB SPN 40 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos. (ivI) Anlog timer switch for security light -01 Set Make of MCCB:-L&T/ Siemens / Legrand/Havells The panel manufacturer should have Govt. Approved Certificates: 1. Panel shall be installed at least 45 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates3. Drawing of panel shall be got approved from GE.Make of MCCB:-L&T/ Siemens / Legrand/Havells
Supply and fixing of testing and commissioning outdoor type LT cubical panel Factory fabricated CRCA Sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 3.15 mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 600 Amp duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched/tied, ferruled for proper identification and crimpled with adequate size of lugs. BUS BAR CHAMBER :- (a) 600 Amp insulated copper busbar of length not less than 60 cm,03 phase and neutral, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.
INSTRUMENT CHAMBER :- (i) Multi function meter - 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-250A, with Amp meter push button type- 01 Set. (iii) C.T's 250/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).B8 Make of Metering Accessories :-L&T/ AE/ Schneider. INCOMING SUPPLY :- (i) MCCB 400 Amps 25 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50 Hz,=01 OUTGOING SUPPLY :- (i) MCCB 200 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=01 Nos., (ii) MCCB 100 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=03 Nos., (ii) MCCB 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=01 Nos. Make of MCCB:-L&T/ Siemens / Legrand/Havells The panel manufacturer should have Govt. Approved Certificates: 1. Panel shall be installed at least 45 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE.The cubical will have a support of angle size 50x50x5mm, & -04 Nos duly grouted 30 Cm below the GL in PCC including a detachabale pre-drilled gland plate of thickness 3.15 mm The auxilary support of suitable SPD (surge protation Device ) protected shall be provided Note:-Design /Drawing of L.T. Panel shall be approved by Garrison Engineer.
Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415 V, 3 phase 50 Hz , AC supply system, dust,weather & vermin proof, made of 3.15 mm thick CRCA sheet, TPN copper busbars of rating 200 Amp Cap.Bottom base channel of MS section not less then 45mmx45mmx5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x5mm at the rear with 2 no earth stud,double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers. cable entry with glands, foundation/grouting on & including PCC as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 200 Amp,4 pole, not less then 45 CM long mounted on insulators for incoming supply - 1 Set (Set of 4 strips) (b) Phase indicator lamp RYB LED type - 1 Set (Set of three). (c) Digital Voltmeter & Ammeter - 02 Nos (d) CT Ration 100/05 CL 1.0 Tape Wound - 01 Set (Set of three) Incoming: (a) MCCB 160 Amp, 415V, 50 Hz, FP, ,25 KA 01 No, Ics= 100% Icu fixed type, complete all as specified and directed by Engr-in-Charge. Outgoing (a) MCCB 100 Amp, 415V, 50 Hz, FP, ,16 ka, Ics= 100% Icu fixed type, complete all as specified and directed by Engr-in-Charge. (b) MCCB 63 Amp, 415V, 50 Hz, FP, ,25 ka, Ics= 100% Icu fixed type, complete all as specified and directed by Engr-in-Charge. Note :- 1. Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. All MCCBs shall be ICS=100% ICU Fixed Type.
Supply, installation, testing, commissioning & electrically connected feeder pillar outdoor type, single door compartmentized with looking arrangement canopy at top weather proof, verman/dust proof of suitable size cubical type factory made of CRCA MS sheet 3.15 mm thick machine pressed of size 60x60x40 cm & angle iron frame 40x40x6 mm for legs and including grouted in PCC 1:2:4 type B1 (20 mm graded stone aggregate) suitable 440 volts AC 3 phase 4 wire bus bar 4 pole made out of suitable size copper strip capacity 400 Amps with 01 No MCCB 415 Volt ,50HZ ,200 Amps,25KA bracking cap ,adjustable thermal setting ics=100% icuFully mounted on procelain insulator enclosed chamber with open able shutter both sides comprising with following complete all as specified.
Supply, installation, testing, commissioning & electrically connected feeder pillar outdoor type, single door compartmentized with looking arrangement canopy at top weather proof, verman/dust proof of suitable size cubical type factory made of CRCA MS sheet 3.15 mm thick machine pressed of size 60x60x40 cm & angle iron frame 40x40x6 mm for legs and including grouted in PCC 1:2:4 type B1 (20 mm graded stone aggregate) suitable 440 volts AC 3 phase 4 wire bus bar 4 pole made out of suitable size copper strip capacity 200 Amps with 01 No MCCB 415 Volt ,50HZ 100 Amps,25KA bracking cap ,adjustable thermal setting ics=100% icuFully mounted on procelain insulator enclosed chamber with openable shutter both sides complete all as specified and directed by Engr-in-Charge
Supply, installation, testing, commissioning & electrically connected feeder pillar outdoor type, single door compartmentized with looking arrangement canopy at top weather proof, verman/dust proof of suitable size cubical type factory made of CRCA MS sheet 3.15 mm thick machine pressed of size 60x60x40 cm & angle iron frame 40x40x6 mm for legs and including grouted in PCC 1:2:4 type B1 (20 mm graded stone aggregate) suitable 440 volts AC 3 phase 4 wire bus bar 4 pole made out of suitable size copper strip capacity 250 Amps with 01 No MCCB 415 Volt ,50HZ ,250 Amps,25KA bracking cap ,adjustable thermal setting ics=100% icuFully mounted on procelain insulator enclosed chamber with open able shutter both sides complete all as specified and directed by Engr-in-Charge.
M&L for Aluminium Lugs of size 16 to 25 qmm complete all as per specified and directed.
M&L for Aluminium Lugs of size 35 to 70 sqmm complete all as per specified and directed.
M&L for Aluminium Lugs of size 90 to 120 sqmm complete all as per specified and directed.
M&L for Aluminium Lugs of size 120 to 185 sqmm complete all as per specified and directed.
M&L for Aluminium Lugs of size 185 to 240 sqmm complete all as per specified and directed.
Supply and fix heat shrinkable End termination kits and accessories of following capacities and type:- Note for item No 16.01 to 16.04 :- Rate for the execavation, returing filling and removing of the earth work and provide labour and Electrician shall deemed to be included in the quoted price, not extra be paid for this items.
Outdoor/indoor 185 to 240 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 120 to 150 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 95 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 35 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Supply and fix heat shrinkable straight through joint kit and accessories of following capacities and type:-Note for item No 17.01 to 17.04 :- Rate for the execavation, returing filling and removing of the earth work and provide labour and Electrician shall deemed to be included in the quoted price, not extra be paid for this items.
Straight through joint kit indoor/outdoor al conductor cable of size 185 to 240 Sqmm and 3.5/4 core
Straight through joint kit indoor/outdoor al conductor cable of size 120 to 150 Sqmm and 3.5/4 core
Straight through joint kit indoor/outdoor al conductor cable of size 35 to 50 Sqmm and 3.5/4 core
Straight through joint kit indoor/outdoor al conductor cable of size 95 Sqmm and 3.5/4 core
M&L for brazing work with copper brazing alloy rod with help of oxygen and LPG cylinder using required copper strip of size 20mmx3mm upto 2.5 feet length alongwith cleaning work of strip with descaling solution/ emery paper upto building height 15mtr complete all as specified and directed
M&L for brazing work with aluminium/GI brazing alloy rod with help of oxygen and LPG cylinder using required GI strip of size 25mmx3/4 mm upto 2.5 feet length alongwith cleaning work of strip with descaling solution/ emery paper upto buildinh height 15 mtr complete all as specified and directed
Supply and fixing of DWC HDPE tubing 40 mm including all fitting/fixtures such as Tee/Elbow/Socket/ Nipple etc.Conforming to IS 16205 bore for laying cable, cut to size and making the tubing for cable protection along with drawn in cable into the HDPE tubing on the surface/on the wall /along drainage etc cutting of road etc cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note :- (a) The using of GI Clamp in the wall/drainage,etc rate are deemed to be included in the quoted rate and nothing shall extra paid to contractor.
Supply and fixing of DWC HDPE tubing 50 mm including all fitting/fixtures such as Tee/Elbow/Socket/ Nipple etc.Conforming to IS 16205 bore for laying cable, cut to size and making the tubing for cable protection along with drawn in cable into the HDPE tubing on the surface/on the wall /along drainage etc cutting of road etc cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note :- (a) The using of GI Clamp in the wall/drainage,etc rate are deemed to be included in the quoted rate and nothing shall extra paid to contractor.
Supply and Laying XLPE Cable insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls complete including taking down all as specified and directed of following sizes :- (Note 1.: Earth work, excavation shall be measured & paid separately under respective item of Schedule and wherever cable laying on walls and uses of thimbles etc rates shall deemed to be included in the quoted rates).
10 Sqmm, 4 core cable
16 Sqmm,4 core cable
25 Sqmm, 3½ core cable
35 Sqmm, 3½ core cable
50 Sqmm, 3½ core cable
95 Sqmm, 3½ core cable
120 Sqmm, 3½ core cable
150 Sqmm, 3½ core cable
185 Sqmm, 3½ core cable
240 Sqmm, 3½ core cable
Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using GI earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion.
Supply and fixing Earth continuity conductor main4 mm Galvanised iron wire fixed to wall on batten or recess or chases including drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. Complete all as specified and as directed
Earth continuity conductor 25 x 3.00 mm aluminium strip main earthing lead fixed to walls on batten or recess or chassis or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by Engr-in-Charge
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil, complete all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and as directed by Engineer-in-Charge.
M & L for Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
Supply and replacement of GI tube light grade of bore 50 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building height completen all as specified and directed by Engr in charge
Supply and replacement of GI tube light grade of bore 80 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building height complete all as specified and directed by Engr in charge
M&L for drilling hole through machine under hard standing /road in different location as per site requirement (between 03 mtr to 40mtr maximum) for laying of pipe for protection of cable etc by means of bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified.
Material and Labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping etc for pole/panel including necessary form work for fair finished exposed concrete surfaces complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (40 mm graded aggregate) cement concrete in foundation and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
M & L for CRCA MS Sheet of 3.15 mm thick alongwith fixing arrangement through nut, bolts or welding etc suitable for panel base plate or panel canopy all as specified and directed by Engineer-in-Charge. Note :- (i) Rate include for making the hole in the gland according to the size of cable and re-connecting the cable in the existing panel etc. (ii) Size of sheet shall be as decided and directed by Engineer-in-Charge.
Supply and fixing of surge protection device single phase Type I (SPD) Class B-3 Phase pluggable with serviceability indicator single phase with neutral for protection of equipment against lightning and switching surges with daettachable type,of phase description Un 275 volts,Iin 5 kA , voc 6kv Imax 10 kA ,Iimp 12.5 kA and neutral Uc 275 volts,I imp 30,voc 6kv kA,In 30 kA ,Imax 60 kA including protected IP20 complete Confiring to IEC/EN 61643-II all as specified make : Havells/schneider electric/L&T/ABB /JMV all as specified
Supply, fixing and installation of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts , nuts and screws as specified type 410 SP-31 (9 metres long) complete all as specifidedc and directed by Engr-in-Charge
Supply & Fix LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, PF>= 0.90, lumen efficacy >= 100 lumen/watts, 5700 K,SPD of voltage rating > 10kv including new lights to be fixed in existing bracket at existing pole/bldg or other extra welding works complete all as specified Make : HPL cat part No HPLLEDSL9060Eor its equivalent /Havells/Bajaj/C&S/Crompton/Polycab as approved by GE
S&F in repairs 2.5 Sqmm 2 core cable, PVC insulated and PVC round sheathed, copper conductor(flexible) industrial cable, 1100 volt, confirming to IS :694 Note- (i) Cable is reqd to be connected from street light to junction box with proper lugs wiht pvc conduite .
Supply and fixing of Cable junction box outdoor shall be made out of Polycarbonate with glass fiber reinforced than 205mm x 255mm x 112 mm(the cable size upto 25 sqmm). The polycarbonate junction box shall be environmental friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66 in accordance with IEC 60529.Weatherproof, UV resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998. The Junction Box with 25Amp Connectors or Terminal Trip or Bus Bar. The Junction Box / Enclosure shall be tested as per IEC including one No. 4 pole connector and chromium plated clamps and nut bolts, cable glands with lock nuts of 2 Nos for each box complete all as per manufacturer’s
Supply and fixing of High galvanized mast LEd light suitable for 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steelwire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation as up to height 15 mtr complete all as specifed and as directedalong with undermentioned desciption (a) Mast Construction: The highmast shaft is in polyonal shape, coninously tapered sections having dimensions and thickness as required in the design made from high tensile steel confirming to BSEN 10025 grade S 355. The plate plasma cut and folded to form polygon of required shape and then welded along longitudinal seams. section lengths are typically designed and are such that transverse welding is not required. The details welding procedure and procedure qualifications are done as per the requirements of standard through renowned third party agency. The partial panetration welds done through GMAW and SAW are proven over a period of time in masts of heights and for all applications.The taper fit friction joints are assembled at site with equipements usually available at construction sites and site fabrication work is not required during assembly. The overlap required is 1.5 times the diameter at the joint. The edge of the door opening is reinforced to guard against buckling and is provided with vandal resistant locking device. The shaft is attached to the flange using full strenth butt welds with supplementary gussets provided between bolt holes. All steel work is generally galvabuzed other standards agreed in contract.
(b) Mast Head Assembly: The mast head assembly is fitted with a three-six pulley system which can accommodate wire ropes and electric cables as per the requirements. The pulley is of non-corrodible material and run on self lubricating bush bearing with stainless steel spindle of diamtere appropriate for wire rope and miulti core flexible cable. Arrangement is provided to separate electric cables and steel wire ropes and also to prevent ropes and cables leaving the pulleys grooves. Pulleys are housed in a chssis intergral with a sleeve which slips over the top of the mast and is secured axially and in azimuth. Guides and stops are provided for docking the luminary carriage. The complete assembly is hot dip galvanized after fabrication. The pulley assembly is protected with a weatherproof hot dip galvanized canopy. Depending on the requirement we can provide 3 ropes and cables. We can also provide pulley arrangement for special application.
(c) Luminaires Carriages: The luminariage is fabricated from ERW steel pipes designed to act as electric conduit with holes for cable entry. It is fitted with junction box mounting breaket(s) and is in two halves joined by bolted flanges to permit removal from an erected mast. Luminaires fixing arms and plates are welded to the carriage. Carriage is fitted with buffer arrangements to prevent damage to the mast finish during movement. Rollers or other moving parts are not required. (d) Winches: Winches are completely self sustaining, self lubricating by means of oil bath, grooved double drum with a grear ratio of 53:1. Single gear and double gear design of winches are available in BEL range. Winches can be operated by a motor or maually. Power tools for operating the winch are available in integral or common versions. BEL winches have been rigorously type tested based on the relevant standards under the guidance and presence of experts from Indian Institute of Technology, Bombay- Mubai.(e) Suspension System: Suspension wires are stainless steel grade 316/304 of 7/19 (6/19 WSC) construction and are provided with stainless steel thimble and terminals. Normal suspension systems are with two continuous wire ropes without any intermediate joints. Suspension systems supplied by BEL are property designed with suitable clamps to prevent entangling of wire ropes and cables. This unique arrangement increases the life of the wire ropes and cables. Other types of suspension systems are also offered against specific requirements.
(f) Electrical System: Multi core flexible power cables are provided for power supply, Cables are with EPR insulation, PCP sheathing and cotton braiding to get the required strength and flexibility. PVC insulated and PVC sheathed cables are also supplied in economy and popular systems. These cables terminate in the base compartment through specially designed metal cload plugs and sockets. At the mast head cables are connected to weather proof cast aluminum/HDG junction box on the luminaires carriage. The power cables are factory cut for ease of installation. A box is provided inside the base compartment of the mast for local MCB isolation of the power supply. Masts shall have facility for testing the luminaires at the bottom level for premium operating system (this facility is not provided for masts located in hazardous area). Masts in hazardous areas are with a flame proof plug socket unit at the bottom. (g) Earth point and Lightning Finial: A 12mm diameter GI bolt is provided on door stiffener in the base compartment as earth point. All standard masts are provided with a sighle spike lightning finial on the head frame at the top most point. The mast body acts as couductor and earth strip is connected to the mast door stiffener.
(h) Foundation : Foundation bolt set comprises anchor plate with hight tensile studs. Mechanical properties ot the studs are given in the data sheet. As foundation bolts are very important in the structural safety of the system.supply these bolts as part of the total system. Exposed portion of the stud/nuts and washers are hot dipped galvanized to increase resistance corrosion. Note : Foundation shall be suitable for highmast and enverionment wind of 200km/hr &Temp -20' C to 45' C and snowfall and shallbe properly mainufacture desigined for as per direction of GE Make : Bajaj / Crompton / Philips / Surya
Supply and fix 250 watt LED flood light, with IP 66 protection, PF>=0.90, lumen efficiency >=110 Lm/Watt, 5700 k SPD of voltage rating > 10kv luminaire engergy saving, environmental friendly long life with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation complete as specified and directed
Supply and fixing of Automatic High mast light switch NATURE SWITCH for automatic switching of High mast lights based on lux level of natural light. The sensor (nature switch ) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compund (sintex make SMC Junction Box or equivalent as approved by GE ) conforming to IP-54. The contactor, MCB and circuit wiring 16 sqmm copper shall be suitable enough to take load of 25 KW single phase load /8 KW load equally distributed over 3-phase (8 KW/phase), contactor rating 40 Amps(2 pole)and 40 amps 4 pole and MCB (single pole) rating 63 amps (SP-3 Nos) complete including sheet metal enclosure with stand made of suitable size angle iron and grouting of enclosure using cement concrete 1:2:4 type B-I (using 20mm graded crushed stone aggregate) all as specified and directed by Engineer-in-Charge Make : Hensel / Swddep / Healer or its equivalent.
PROACH ASSOCIATES BUILDERS & ENGINEERS (BID ID -3160959)
M/S M P Construction Co (BID ID -3160739)
ASIA BUILDER (BID ID -3160894)
PAWAN KUMAR GOVT. CONTRACTORS (BID ID -3166419)
DAVINDER SINGH (BID ID -3166343)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .