Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.3 L+₹2.5 L (14.7%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹20.4 L+₹3.6 L (21.6%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹23.4 L+₹6.6 L (39.2%)Rejected-AOC 79 B BLOCK SRI GANGANAGAR 335001 RAJASTHAN | GANGANAGAR | RAJASTHAN | 335001 | L4 | Rejected-AOC L4 | |
| 5 | L5₹25.5 L+₹8.7 L (51.8%)Rejected-AOC NO 133 RASHTRAPATHI ROAD SECUNDERABAD 500 003 | SECUNDERABAD | HYDERABAD | TELANGANA | 500003 | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | Haasith constructions L1 | THAKURJI ENTERPRISES L4 | SRI LAXMI SREENIVASA BUILDERS L2 | SRI SAI RAM ENTERPRISES L3 | THE DECAN ENGINEERING AND REFRIGERATION COMPANY L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00NOTES :- 1. Contractor need to purchase minimum 50% of all items mentioned in this CA within 20 days of getting sample approval and kept in custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of item/date. 2. Contractor should buy the exact items which are given with catalogue reference. Other makes will be approved only by submitting non availability Certificate Company. Contractor need to remove all the dismantled items without delay. 3. Rate quoted for demolition/dismantling /taking down is inclusive of removing the same from site and dumping at given locations anywhere inside station. 4. Contractor will make his own arrangement to store his items. 5. Some places in this contract where the vehicle will not reach the spot directly, the material will be moved manually in these places. The rate quoted will be considered all inclusive on this account. 6. All trade skilled labour required in this contract shall be present daily in working hours, irrespective of complaints received. 7. Complaint for a similar items may be in scattered / different area, quoted rate will be considered all inclusive on this account. | ||||||||
| 1.01 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials and making good disturbed surfaces of walls, floors etc. including paint touch up to match with the existing surface as per site requirement complete all as specified and directed by Engr-in-Charge. | 680 | Point | 5 ₹3,400 Lowest | 10 ₹6,800 | 8 ₹5,440 | 10 ₹6,800 | 37 ₹25,160 |
| 2.00 | Taking down existing unserviceable MCCB/main switch (any type and capacity) and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge. | 9 | Each | 5 ₹45 Lowest | 10 ₹90 | 10 ₹90 | 10 ₹90 | 47 ₹423 |
| 3.00 | Taking down existing unserviceable distribution board with MCBs, switch fuse unit, enclosure and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge. | 22 | Each | 5 ₹110 Lowest | 10 ₹220 | 50 ₹1,100 | 10 ₹220 | 47 ₹1,034 |
| 4.00 | Taking down Existing old unserviceable submain wiring of any description /type size and removal of UNSV material from site and making good the disturbed surface of walls / ceiling so as to match with the existing finishes all as specified and as directed by the Engineer -in- charge . | 240 | RM | 5 ₹1,200 Lowest | 10 ₹2,400 | 8 ₹1,920 | 10 ₹2,400 | 10 ₹2,400 |
| 5.00M&L for point wiring with 1.5 Sqmm (nominal area) multi stranded copper conductor, single core, FR-LSH PVC insulated & unsheathed cable with proper colour coding subjected to IS 732, 1100 volts grade drawn in ISI marked MMS non-metallic PVC conduit of size not less than 20mm dia conforming to IS 9537:latest, surface type terminated in sunken type GI sheet metal flush boxes of 16 Gauge including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FR-LSH PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- | ||||||||
| 5.01NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. If the building is stone masonry, diamond tools must be used to cut the surfaces. In case the box needs to be put on surface, prior approval must be taken from the Engineer-in-charge and high impact ABS plastic boxes with minimum 1mm thickness shall be used instead of metal boxes. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision and installation of conduits, covering sunken boards/terminal boxes / junction boxes of any shape and size modular white colour cover plate with frame and modular metal flush box. All metal boxes and plates to be of the same make as the switches mentioned in this schedule. Note: Inspection elbows, inspection Tees, self locking saddle clips shall be used as accessories for laying conduits as directed by the Engineer-in-charge. | ||||||||
| 5.02 | a) One light point controlled by one, 1 way switch | 100 | Point | 465 ₹46,500 Lowest | 650 ₹65,000 | 670 ₹67,000 | 650 ₹65,000 | 675 ₹67,500 |
| 5.03 | b) One 3 pin 6 Amps socket point controlled by one switch on same board | 30 | Point | 130 ₹3,900 Lowest | 500 ₹15,000 | 160 ₹4,800 | 180 ₹5,400 | 200 ₹6,000 |
| 5.04 | c) One 3 pin 6 Amps socket point controlled by one switch on independent board | 50 | Point | 465 ₹23,250 Lowest | 650 ₹32,500 | 670 ₹33,500 | 650 ₹32,500 | 675 ₹33,750 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
26 Jul 2025, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION AT AFS HAKIMPET UNDER GE (AF) HAKIMPET
2025_MES_717367_1
8801/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hakimpet
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (AF) Hakimpet
₹58,000
Yes
13 Sept 2025
28 Jun 2025
28 Jul 2025
28 Jun 2025
26 Jul 2025
12 Jul 2025
Amount
NOTES :- 1. Contractor need to purchase minimum 50% of all items mentioned in this CA within 20 days of getting sample approval and kept in custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of item/date. 2. Contractor should buy the exact items which are given with catalogue reference. Other makes will be approved only by submitting non availability Certificate Company. Contractor need to remove all the dismantled items without delay. 3. Rate quoted for demolition/dismantling /taking down is inclusive of removing the same from site and dumping at given locations anywhere inside station. 4. Contractor will make his own arrangement to store his items. 5. Some places in this contract where the vehicle will not reach the spot directly, the material will be moved manually in these places. The rate quoted will be considered all inclusive on this account. 6. All trade skilled labour required in this contract shall be present daily in working hours, irrespective of complaints received. 7. Complaint for a similar items may be in scattered / different area, quoted rate will be considered all inclusive on this account.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials and making good disturbed surfaces of walls, floors etc. including paint touch up to match with the existing surface as per site requirement complete all as specified and directed by Engr-in-Charge.
Taking down existing unserviceable MCCB/main switch (any type and capacity) and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge.
Taking down existing unserviceable distribution board with MCBs, switch fuse unit, enclosure and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge.
Taking down Existing old unserviceable submain wiring of any description /type size and removal of UNSV material from site and making good the disturbed surface of walls / ceiling so as to match with the existing finishes all as specified and as directed by the Engineer -in- charge .
M&L for point wiring with 1.5 Sqmm (nominal area) multi stranded copper conductor, single core, FR-LSH PVC insulated & unsheathed cable with proper colour coding subjected to IS 732, 1100 volts grade drawn in ISI marked MMS non-metallic PVC conduit of size not less than 20mm dia conforming to IS 9537:latest, surface type terminated in sunken type GI sheet metal flush boxes of 16 Gauge including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FR-LSH PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:-
NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. If the building is stone masonry, diamond tools must be used to cut the surfaces. In case the box needs to be put on surface, prior approval must be taken from the Engineer-in-charge and high impact ABS plastic boxes with minimum 1mm thickness shall be used instead of metal boxes. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision and installation of conduits, covering sunken boards/terminal boxes / junction boxes of any shape and size modular white colour cover plate with frame and modular metal flush box. All metal boxes and plates to be of the same make as the switches mentioned in this schedule. Note: Inspection elbows, inspection Tees, self locking saddle clips shall be used as accessories for laying conduits as directed by the Engineer-in-charge.
a) One light point controlled by one, 1 way switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan/exhaust fan point controlled by one 1way switch
e) One bell point controlled by one switch
f) One light point controlled by two two way switches
g) One light/buzzer point controlled by one; one way switch pertaining to inverter
h) One fan/exhaust fan point controlled by one, one way switch pertaining to inverter
All as per item No. 5 here-in-before but with 2.5 Sqmm for 3 pin 6 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
All as per item No. 5 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sq.mm FRLSH insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through existing PVC conduit/casing capping of suitable size but not less than 20 mm dia on surface of stone/concrete wall /roof etc all as per site requirement including FRLSH,PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made out of 1.6 mm thick MS sheet with sink into the wall for mounting including laminated sheet cover 3mm thick laminated hylam sheet fixed with cadmium plated screws/PVC gang box fully enclosed type for mounting switches,sockets,fan regulator, etc including all accessories and making good the disturbed surfaces of walls and paint touch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge. Note: Inspection elbows, inspection Tees, self locking saddle clips shall be used as accessories for laying conduits as directed by the Engineer-in-charge.
a) One light point controlled by one, 1 way switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan/exhaust fan point controlled by one 1way switch
All as per item No. 8 here-in-before but with 2.5 Sqmm for 3 pin 6 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
All as per item No. 8 here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5 Sqmm (nominal area) multi stranded copper conductor, single core, FR-LSH PVC insulated & unsheathed cable in accordance with IS 694 with proper colour coding, 1100 volts grade drawn in ISI marked MMS non-metallic PVC conduit of size not less than 20mm dia conforming to IS 9537:latest, concealed type terminated in sunken type GI sheet metal flush boxes of 16 Gauge (i.e. 1.6mm thickness) including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FR-LSH PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:-
NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. If the building is stone masonry, diamond tools must be used to cut the surfaces. In case the flush box needs to be installed on surface, prior approval must be taken from the Engineer-in-charge and surface modular boxes made of FR grade ABS of minimum 1mm thickness with rounded corners need to be used instead of metal flush boxes. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision and installation of conduits, covering sunken boards/terminal boxes / junction boxes of any shape and size modular white colour cover plate with frame and modular metal flush box. All metal boxes and plates to be of the same make as the switches mentioned in this schedule.
a) One light point controlled by one, 1 way switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan/exhaust fan point controlled by one 1way switch
e) One bell point controlled by one switch
f) One light point controlled by two two way switches
g) One light/buzzer point controlled by one; one way switch pertaining to inverter
h) One fan/exhaust fan point controlled by one, one way switch pertaining to inverter
All as per item here-in-before but with 2.5 Sqmm for 3 pin 6 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
All as per item here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sq.mm FRLSH insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through existing concealed PVC conduit upto 32mm including FRLSH, PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made out of 1.6 mm thick MS sheet box with 3mm thick laminated hylam sheet fixed with cadmium plated screws for mounting switches, sockets, fan regulator, etc including all accesories if required making good the disturbed surfaces of walls and paint tuch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge.
a) One light point controlled by one switch
b) One 3 pin 6 Amps socket point controlled by one switch on same board
c) One 3 pin 6 Amps socket point controlled by one switch on independent board
d) One ceiling fan point controlled by one switch and regulator
All as per item here-in-before but with 2.5 Sqmm for 3 pin 6 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
All as per item here-in-before but with 4 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of switch piano flush type, single pole one way 6 Amps 240 volts ISI marked complete all as specified and as directed.
S&F in replacement of bell push,flush type, 6 Amps ,240 Volts ISI marked complete all as specified and directed.
S&F in replacement of switch socket combination 2 in 1, 3 pin 6 Amps, flush type, universal ,240 volts complete all as specified and as directed
M & L in replacement of switch socket combination 2 in 1, 3 pin , 6 Amps/16 Amps, flush type,universal,240 volts complete all as specified and as directed
M & L in replacement of Call bell, ding dong, AC 240 Volts complete all as specified and as directed
S&F in replacement of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz 2 module size in 5 steps flush type complete all as specified and directed.
S&F in replacement of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz single module size in 5 steps flush type complete all as specified and directed.
S & F in replacement of batten/angle holder, PVC/Polycarbonate type with back plate, 240 V , 50 Hz suitable for batten fittings complete all as specified and directed.
S&F in replacement of ceiling rose 6 A, 3 plate,PVC/polycarbonate ,insulated body 240 Volt , 50 Hz all as specified and as directed.
M&L for submain wiring along with earth wire with 3 x 4.0 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through existing PVC Conduit in wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 4.0 Sqmm copper cable shall be measured as one unit length.
All as per item here-in-before but with 3 x 6.0 sqmm FRLSH PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 6.0 Sqmm copper cable shall be measured as one unit length.
M&L for submain wiring alongwith earth wire with 3 x 4.0 Sqmm FRLSH PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including MMS PVC Conduit and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 4.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length.
M&L for submain wiring alongwith earth wire with 3 x 4.0 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including Steel Conduit and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 4.0 Sqmm copper cable and one run of steel conduit shall be measured as one unit length.
M/L for Sub main wiring with 4 runs of PVC insulated unsheathed multi stranded single core copper conducter 6 Sqmm drawn through PVC conduit/casing capping including accessaries with 6 sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up ,all as directed. Note: 4 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length.
M/L for Sub main wiring with 4 runs of PVC insulated unsheathed multi stranded single core copper conducter 10 Sqmm drawn through PVC conduit/casing capping including accessaries with 10 sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up ,all as directed. Note: 4 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length.
Supply and fix in replacement factory made indoor type dust and vermin proof Feeder pillar panel board cubical double door hinged type compartmentalized of suitable size 415 volts, AC 50 Hz fabricated of CRCA sheet 3 mm thick machine pressed grouted in PCC 1:2:4 type B1 (20mm grade stone aggregated) powder coated inside and outside complete including 4 poles copper bus bar of suitable size mounted on porcelain insulators and enclosed in chamber made out of 2mm thick CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles / lugs cable gland with open able shutters and comprising complete all as specified and as directed. of the following :-
(i) incoming MCCB 100 Amp, 36 KA, 4 Pole 415 Volt - 01 Nos, 6A SP MCB-03 Nos (ii) Outgoing MCB SPN 6-32 Amp, 10 KA 4 Pole 415 Volt - 05 Nos (iii) Copper bus bar for 3 Ph & Neutral 200 Amp- 01 Set (iv) Panel should have provision and space to install 5No. no of 1 phase electric meters.Electric wiring from outgoing MCBs to Electric meters to be provided. Electric meters will be supplied by MES. Outgoing Supply from electric meter to main MCB DB Can be measured separately (vi) Multifunction meter 0-500V, 0-100A (viii) Phase indicator neon lamps for 1 Ph -01 Set
Supply, Install, testing & commissioning factory made indoor type dust and vermin proof Feeder pillar panel board cubical double door hinged type compartmentalized of suitable size 415 volts, AC 50 Hz fabricated of CRCA sheet 3 mm thick machine pressed grouted in PCC 1:2:4 type B1 (20mm grade stone aggregated) powder coated inside and outside complete including 4 poles copper bus bar of suitable size mounted on porcelain insulators and enclosed in chamber made out of 2mm thick CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles / lugs cable gland with open able shutters and comprising of the following :-
S& F distribution board double door type TPN 8 way sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge.
All as per item above but of TPN 4 way.
S& F distribution board double door type VTPN 8 way sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge.
S& F distribution board double door type VTPN 4 way sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge.
S& F MCB distribution board single door type SPN 12 way sheet steel powder painted with bus bar ,neutral link & earth bar etc.with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing circuit complete all as specified and directed by Engineer-in-Charge.
All as per item above but of SPN 8 way.
All as per item above but of SPN 4 way.
S& F sheet metal powder painted double pole enclosure with a two pin and earth plug and socket flushing in wall including 20 Amps rated double pole MCB 10 KA, "C" curve complete all as specified and directed by Engineer-in-Charge.
S& F sheet metal powder painted triple pole and neutral enclosure with a three pin and earth plug and socket flushing in wall including 32 Amps rated 415 V, three pole MCB 10 KA, "C" curve complete all as specified and directed by Engineer-in-Charge.
S&F MCB Triple pole and Neutral (TPN) of capacity 40-100 Amps 415 volts ,breaking capacity 10 KA,'C' series ,fixed in proper position all as directed by the Engineer in charge .
S& F MCB, SPN, 40-63 Amps, 240 Volts
S& F MCB , SP, 6 - 32 Amps, 240 Volts
S& F MCCB 125 Amp three pole 415 Volt , breaking capacity 16 KA, with fixed thermal & magnetic setting complete all as specified and as directed by the Engineer in charge.
S& F MCCB 25-100 Amp Three pole 415 Volt , breaking capacity, 16 KA, with fixed thermal & magnetic setting complete all as specified and as directed by the Engineer in charge.
S & F 4ft 20W LED batten tubelight surface/wall mounted with powder coated Aluminium housing, high optically efficient polycarbonate diffuser, inbuilt electronic driver duly wired upto terminal block, luminous efficiency > 100 lm/watt, surge protection upto 4kV, 440V High voltage protection, power factor > 0.95, CRI > 80 all as specified and directed. Model: Crompton Linea Pro or similar
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 240 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete, all as specified and directed.
S&F LED light fitting in replacement of 10 watt bulk head luminaries complete with all accessories and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S& F in replacement Deep recessed downlights, 18Watt, aluminium construction EMC/EMI compliant, Ripple<5% flicker free driver, including connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light to roof surface all as specified and directed. Model No. Havells VIBEFLRDDLR18WLED840S or similar
S& F in replacement Deep recessed downlights, 12Watt, aluminium construction EMC/EMI compliant, Ripple<5% flicker free driver, including connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light to roof surface all as specified and directed. Model No. Havells VIBEFLRDDLR12WLED840S / Philips / CG / Bajaj
S& F in replacement surface downlights, 18Watt, aluminium housing with heat sink including connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light to roof surface all as specified and directed. Model No. Havells INTEGRANXTRDDLRSURD18WLED840S / Philips / CG / Bajaj
S&F in replacement of Flexible Mono-color Mains Voltage NEON LED strips lights with Silicon housing suitable for outdoor applications. IP65 including giving electrical connection complete all as specified and directed by the Engineer-in-charge. ModelNo. Havells FLEXISTRIPNEON50MIP65AC7.5W/M830V1 / Philips / CG / Bajaj
S&F in replacement of high efficacy recess luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal 35/36 W LED (2ft X 2ft) complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Disconnecting ceiling fans of any sweep and from any height including electrical connections, bringing down, dismantling, opening up, cleaning internally and externally, overhauling by replacing unserviceable items such as split pins, bearings, bushes, copper flexible cord, cotter pins and check nuts etc, lubrication with approved lubricants, reassembling including replacement of worn-out /defective parts and refixing for smooth functioning and connecting cable from ceiling rose to fan including testing complete all as specified and directed by the Engineer-in-charge.
Description all as per above here-in-before but exhaust fan /wall mounting fan/Pedestal fan of sweep 230/300/375/450 mm complete all as specified and as directed by the Engineer-in charge.
Notes for item No 56 & 57:- Replacement of unserviceable spare part required for servicing/overhaulingand rewinding of fans shall be measured and paid separately under relevent items after testing and commissioning vide relevent Item of this schedule.
Supply only the following parts in replacement of Ceiling/ Exhaust Fans of existing makes and size complete all as specified and as directed by the Engineer-in Chargre :-
(a) Capacitor 2.5 mfd capacity 240 volts. (Make ) : CAPCO/TIBCON
(b) Ball bearing of suitable size. (Make ) : NBC/SKF/TATA.
(c) Gun metal bush
(d) Copper flexible cord 3 core of size 23/00076, 5m bundle
(e) Fan Clamp with rubber bush
(f) Down rod, 400 mm long
(g) Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. (M & L)
(h) Capacitor 4 mfd capacity 240 volts .(Make ) : CAPCO/TIBCON
(j) Ball bearing for exhaust fans of suitable size .(Make ) : NBC/SKF/TATA
Taking out burnt copper winding wire from fan, cleaning the rotor shaft properly and rewinding with new super enamelled copper winding wire as per existing size/ gauge including heating/ varnishing etc complete as per manufacturer's design for the following fans:-
(a) Ceiling fan of 1200/1400 mm sweep
(b) Exhaust fan of 230/300 mm sweep
(c) Exhaust fan of 375/450/305/380 mm sweep
(d) Wall mounting/Pedestal fan of 400/450 mm sweep
S & F in replacement of motor for plastic exhaust fan of any size and type complete all as specified and directed by the Engineer-in-Charge.
S & F in replacement of louvers with suitable frame work and fixing arrangements for exhaust fan of any size sweep complete including removing the existing unserviceable one all as specified and directed by the Engineer-in-Charge.
S & F in replacement of aluminium frame and SS mesh Grade 304 mosquito net ivory colour with stopper and screws suitable for exhaust fan of any size all as specified and directed by the Engineer-in-Charge.
Taking Down water heater (Electric Geyser) storage type of any make of 25 / 50 ltr capacity after disconnecting the existing electrical connection, water pipes and reassembling in all respects after replacing unserviceable parts/components and testing for proper working after repairs and refixing in the original place/position duly connecting up water supply and electric supply etc.complete all as specified and as directed by the Engineer-in-Charge.
Note :- Spare parts replaced shall be measured and paid separately under relevent items below. However labour cost of replacement is deemed to be included in the rate quoted.
Supply only the following parts in replacement of water heater (Electric Geyser) storage type of given make and size complete all as specified and as directed by the Engineer-in Chargre :-
(a) Thermostat ISI marked suitable for 25/50 litre capacity . Make -sphare hot /bajaj/ditz/picco/usha /racold .
(b) Heating element ISI marked 2000 watt push/thread type circular /triangular base suitable for any make and size. Make - bajaj / Racold
(c) Indicator bulb 240 V suitable for given make, type and model
S & F in replacement of pressure release valve suitable for 25/50 litre capacity geyser including taking out the existing unserviceable one all as specified and directed by Engineer-in-Charge. Make -Sphare hot /bajaj/ditz/Picco/usha .
S & F in replacement of gasket rubber suitable for geyser of capacity 25/50 litre including taking out the existing unserviceable one complete all as specified.
S & F in replacement of non return valve gunmetal ISI marked for 15 mm bore with suitable fittings.Make - Kirloskar / Leader /Kartar .
S & F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides for cold water connection.
S & F in replacement of PVC connection 15 mm dia 900 mm long with PTMT nuts on both sides for cold water connection.
S & F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides for hot water connection.
S & F in replacement of PVC connection 15 mm dia 900 mm long with PTMT nuts on both sides for hot water connection.
S & F in replacement of PVC insulated and PVS sheathed flexible Copper Cable 3 core x 4.0 Sq mm from Geysers to socket.
S & F in replacement of multi stranded flexible wire white, 7/42 AWG, 70RM bundle complete all as specified and directed by the Engineer-in-charge
Supply and fixing of Round sheet 5" complete all as specified and directed by Engineer-in-charge
Supply and fixing of Round sheet 6" all as specified and directed by Engineer-in-charge
Suppy only China nails 1kg all as specified and directed by Engineer-in-charge
Suppy only Insulation tape all as specified and directed by Engineer-in-charge
Suppy only 3/4" junction box all as specified and directed by Engineer-in-charge
Suppy and fixing of Heavy duty fan hook all as specified and directed by Engineer-in-charge
Suppy only Wooden gatti all as specified and directed by Engineer-in-charge
Suppy only Wooden screw 1.5" 100pc all as specified and directed by Engineer-in-charge
Suppy only Wooden screw 2" 100pcs all as specified and directed by Engineer-in-charge
Suppy only Bamboo nails 2.5" 1kg all as specified and directed by Engineer-in-charge
Suppy only 1" screw black 500pcs pack all as specified and directed by Engineer-in-charge
Suppy only Hacksaw blade all as specified and directed by Engineer-in-charge
Supply only electrical flexible conduit 25mm dia, dark grey/white, corrugated , standard length of 25m all as specified and directed by Engineer-in-charge
S & F in replacement of plug top 3 pin 6 Amps 240 volts. Make : Anchor/Leader/Havells.
S & F in replacement of plug top 3 pin 16 Amps 240 volts. Make : Anchor/Leader/Havells.
S&F in replacement 400mm swing wall fan, 4star, smooth oscillation, copper motor with remote control, 72 speeds, plastic body including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed
S&F in replacement 400mm oscillating pedestal fan with tilt mechanism,smooth oscillation, 240V, copper motor plastic body with telescopic arranagement including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed
S&F in replacement LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection with suitable no of nuts, bolts and clamps complete all as specified and directed by Engr-in-charge
S&F electric water heater, vertical storage type with ferroglass coated anti-rust inner container and heating element upto 2 KW capacity 25 litre, heavy duty anode rod, preset thermal cutout, BEE 5 Star rated as per latest BEE norms (i.e. standing losses ≤ 0.465 kWh/24 hour/45°C which is only valid till 31st Dec 2025, material shall be supplied as per latest revision at the time of supply with all accessories such as safety valve, thermostat, NRV, connection piece(hot and cold water connection pipe) etc including taking down the existing unserviceable geyser and depositing it to MES E/M Store complete complete all as specified and directed by Engr-in-charge.
S&F Ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor, Non-BLDC, power consumption not to exceed 40W, BEE 3 star rated as per latest BEE norms including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed by Engr-in-charge. Model: Havells ES40/ Bajaj Sabse Tezz/similar
S&F in replacement of flame proof exhaust fan 12" including connecting it to the ceiling rose including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed by the Engineer-in-charge
S&F in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed
All as per item here-in-before but with 200mm sweep complete all as specified and directed
S&F in replacement heavy duty exhaust fan 300mm sweep, double ball bearings with bird protective guard, wall mounted, metallic body with minium noise level including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed
S&F in replacement Exhaust fan, steel body AC Single phase 230 V of size 300 mm sweep with blades, and frame and louvers including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed by Engr-in-charge
S&F in replacement Exhaust fan, steel body AC Single phase 230 V of size 225 mm sweep with blades, and frame and louvers including taking down the existing unserviceable fan and depositing it to MES E/M Store complete all as specified and directed by Engr-in-charge
S&F in replacement electronic energy meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH including taking down the existing unserviceable meter and depositing it to MES E/M Storecomplete all as specified and directed by Engineer-in-charge
S&F exhaust fan, steel body AC single Phase. 230V of size 450mm sweep heavy duty with, blades, and frame and louvers complete all as specified and directed
Supply 12" gold life smart down rod (Anti suicide fan rod) MS pipe zinc plated, 19mm OD, 1.8+/- 0.05mm thick, spring set grade 3 carbon steel material zinc plated, MSME tested for performance test and opening at impact load of 22 kgf + and spring hidden in pipe will expand to about 1 mtr or more, powder coated white colour for ceiling fans of any size with all accessories complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Weather proof flat twin core service cable size 16 Sq mm aluminium conductor PVC insulated and PVS sheathed.
S&F in replacement of Weather proof flat twin core service cable size 10 Sq mm aluminium conductor PVC insulated and PVS sheathed.
S & F in replacement of apparatus plate (bottom plate in which element and thermostat are fixed) complete suitable for 25 ltr capacity geyser including taking out existing unserviceable one all as specified and directed.
Maintenace of solar water heater of capacity 200/300/500 Ltr Capacity and checking the FPC collector,tank insulation and flanges all defective parts to be replaced and paid separately.
S&F in replacement of the following parts of solar water heater storage type of existing make and size complete all as specified and as directed by the Engineer-in Chargre :-
(a) Aluminium dummy gasket
(b) EPDM Hole gasket
(c) brass flange
(d) Threaded Flange
S & F in replacement of apparatus plate (bottom plate in which element and thermostat are fixed) complete suitable for 50 ltr capacity geyser including taking out existing unserviceable one all as specified and directed.
Repairing/overhauling of TPN/SPN DBs of any size/type fixed on building wall incl cleaning with compressed air, tightening of all electric connection to the bus bar & switch gears , refixing of loosed doors with proper fixing & locking arrangement & necessary welding work as required and replacement of wornout/ burnt/rusted/ loose lugs , door lock, nut bolt,hing, washers,internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire ,repair to plaster work as require at site and including disconnection of all cable/ sub main from the bus bar and insulating the naked portion of Al/Cu conductor and re-connect the same after repair of panel and proper connection of main earth wire/lead with panel body using lugs complete all as specified and directed.
S&F concealed meter box with isolator made from minimum 0.7mm thick CRCA sheet, to accommodate 1No. Single phase energy meter complete all as specified and directed.
S&F concealed meter box with isolator made from minimum 0.7mm thick CRCA sheet, to accommodate 1No. Three phase energy meter complete all as specified and directed.
S&F in replacement of Flame proof weather proof LED Tube light fitting CMRI certified recommended for gas/ vapor group IIA and IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass suitable for 2 x 16 Watt (4 feet) LED tube lights, including all accessories such as drivers, tub lights, connector etc complete all as specified.
M&L for porcelain vitreous white seperators and fixing screws etc to be refixing along with the pole and wall with existing copper strip all as directed by Engr in Charge.
M&L for cutting round holes suitable for fixing of exhaust fan any size and shape into through stone/brick walls built in cement mortar or cement lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required and plastering in CM 1:4 external / internal surfaces and finished to match with the existing surfaces complete all as specified and directed by Engr-in-charge.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried 6cm dept in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing including porcelain vitreous white seperators and fixing screws with brazing at each possible joint etc. as required 32X6mm GI strip all as directed by Engr in Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron or steel earth lead strip 32x6 mm size upto 7.5 mtr long in single length by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part I including necessary excavation in hard/dense soil and earth work GI pipe 20mm dia medium grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to LT panel board as indicated including testing complete all as specified and as directed.
M&L for earthing pit display boards made out of 3mm thick MS sheet of size 30 x 35cm welded to 75cm long 25 x 25 x 5 mm thick MS angle iron grouted in PCC 1:3:6 (with 20mm stone aggregate) to a depth of 20 cm and applying two coats of synthetic enamel paint of approved color over a coat of red oxide primer and writing the letters on plate for showing the following details: 1. EARTHING PIT NO : 2. DATE OF MEASUREMENT : 3. NEXT DUE DATE : 4. STANDARD VALUE : 5. VALUE OBTAINED : Note : Shape, size and colour of display board should be approved by Engr in Charge before fixing at site.
Measurement of earth resistance in presence of user, recording the values in Earth resistance test register, obtaining signature from user at locations and as per timelines prescibed by Engineer-incharge. Note: The necessary T&P shall be provided by the contractor to the person carrying out the job.
S&F in replacement of switch Modular type single pole one way 6 Amps 240 volts complete all as specified and as directed.
S&F in replacement of switch Modular type single pole one way 16 Amps 240 volts complete all as specified and as directed.
S&F in replacement of bell push,modular type, 6 Amps ,240 Volts ISI marked complete.
S&F in replacement of socket 2 in 1, 3 pin 6 Amps, modular type, universal ,240 volts complete all as specified and as directed
S&F in replacement of socket 2 in 1, 3 pin 16 Amps, modular type, universal ,240 volts complete all as specified and as directed
S&F in replacement of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz 2 module size in 5 steps modular type complete all as specified and directed.
S&F in replacement post top lanterns, 25W , IP65 long life aesthetically designed with symmetrical light distribution with high power LED , clear/opaque cover as per site requirement complete all as specified and directed.
S&F in replacement of existing Reading lights with 3W, 240V AC, 4000K flexible reading lights complete all as specified and directed (Philips Model No. 30975 equivalent make Havells/ CG/ Bajaj.
S&F in replacement new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED 8 Watts as light source with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size and fixing arrangements such as grouting with suitable nuts bolts and washers in PCC base complete all as specified and directed by Engineer-in-Charge. Make:- Havells Model No BAMBOOBLS8WLED830PSYMTOPC or equivelent make Bajaj/ Crompton/ Philips.
S&F in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed
S&F in replacement LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed
S&F in replacement 12W LED T bulbs, cool day white, energy efficient, no visible flickering, glare reduction technology complete all as specified and directed
S&F of heavy duty hanging bolts set for electric geysers of any size and type, 8mm thick, high quality iron material complete all as specified and directed
S&F of GI bar saddle clamps 3/4" complete all as specified and directed
M & L in replacement of Electric Gong bell, with 12 inch Dia metal body, AC 240 Volts from site all as specified and directed.
SRI LAXMI SREENIVASA BUILDERS (BID ID -3372191)
SRI SAI RAM ENTERPRISES (BID ID -3363807)
THAKURJI ENTERPRISES (BID ID -3372366)
THE DECAN ENGINEERING AND REFRIGERATION COMPANY (BID ID -3362019)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .