Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.9 L+₹1.6 L (8.11%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹26.0 L+₹6.6 L (34.1%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹29.9 L+₹10.6 L (54.7%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹34.1 L+₹14.7 L (76.0%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Aug 2020, 6:00 pmClosed
GE (AF) PALAM
GE (AF) PALAM, DELHI CANITT-10
GENP-19/2020-21 REPAIR/MAINTENANCE OF LT CABLES, LT OH LINES, LT PANELS AND CONNECTED ITEMS IN ROCK VIEW AND PINTO PARK AREA UNDER GE (AF) PALAM
2020_MES_359038_1
GENP-19/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) PALAM
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE (AF) PALAM
₹90,000
Yes
6 Oct 2020
7 Jul 2020
5 Aug 2020
7 Jul 2020
4 Aug 2020
21 Jul 2020
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep n.exc 10 Sqm on plain and getting out for taking out/laying cable etc complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and to be achieved 18cm thickness after punning..
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat.
Laying only old serviceable bricks (retrieved under item 01 of Sch ‘A’).
Taking out old unserviceable LT under ground cable any type from trenches, pipes & poles complete all as directed by Engr-in-Charge.
Relaying of old serviceable LT cables in trenches, pipes and on poles as obtained from item No. 7 above
Supply and laying XLPE insulated LT 1100 Volt grade, armoured under ground cable with stranded aluminium conductor of 16 Sqmm 2 Core in trenches /passing through pipes/ on poles etc complele all as specified and directed.
All as item No 9 above but 16 sqmm 4 core
All as item No 9 above but 25 sqmm 3.5 core
All as item No 9 above but 35 sqmm 3.5 core
All as item No 9 above but 70 sqmm 3.5 core
All as item No 9 above but 95 sqmm 3.5 core
All as item No 9 above but 120 sqmm 3.5 core
All as item No 9 above but 185 sqmm 3.5 core
All as item No 9 above but 240 sqmm 3.5 core
Supply, installation, testing and commissioning in replacement of out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general construction conforming to IS : 8623/93 and the panel duly supported with suitable size of MS angle iron. The LT panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer ACB/MCCB. The LT panel to be incorporated with Digital Multi functional meter VAFPP (Voltage,current,frequency,power factor)- 01 No., Phase indicator lamp (LED type) - 1 Set (set of three). The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (The cost of provn of PCC foundation for fixing the panel is deemed to be included in the quoted rate). INCOMING : (i) MCCB 400A 4 pole, 36 KA with adjustable thermal & adjustable magnetic setting - 1 No. OUT GOING : (i) MCCB 320, 3 pole, 36 KA with adjustable thermal & magnetic setting -01 No. (ii) On load change over switch 400 Amps Four pole. Make: Havells Cat No. IHCNFO0400 - 01 No. (iii) MCCB 63 Amps, 3 pole, 10 KA with adjustable thermal & fixed magnetic setting - 08 Nos. (iv) Digital type time switch 32 Amps 3P module, DIN 24 hours programmable every 1 minutes with 28 memory complete with contactor and other accessories-01 No.
Supply, installation, testing and commissioning in replacement of out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general construction conforming to IS : 8623/93 and the panel duly supported with suitable size of MS angle iron. The LT panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer ACB/MCCB. The LT panel to be incorporated with Digital Multi functional meter VAFPP (Voltage,current,frequency,power factor)- 01 No., Phase indicator lamp (LED type) - 1 Set (set of three). The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (The cost of provn of PCC foundation for fixing the panel is deemed to be included in the quoted rate). INCOMING : (i) MCCB 250A 4 pole, 36 KA with adjustable thermal & adjustable magnetic setting - 1 No. OUT GOING : (i) MCCB 63 Amps, 3 pole, 10 KA with adjustable thermal & fixed magnetic setting - 10 Nos (ii) Digital type time switch 32 Amps 3P module, DIN 24 hours programmable every 1 minutes with 28 memory complete with contactor and other accessories-01 No.
Supply, installation, testing and commissioning in replacement of out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general construction conforming to IS : 8623/93 and the panel duly supported with suitable size of MS angle iron. The LT panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer ACB/MCCB. The LT panel to be incorporated with Digital Multi functional meter VAFPP (Voltage,current,frequency,power factor)- 01 No., Phase indicator lamp (LED type) - 1 Set (set of three). The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (The cost of provn of PCC foundation for fixing the panel is deemed to be included in the quoted rate). INCOMING : (i) MCCB 200A 4 pole 36 KA with adjustable thermal & adjustable magnetic setting - 1 No. OUT GOING : (i) MCCB 63 Amps, 3 pole, 10 KA with adjustable thermal & fixed magnetic setting - 08 Nos (ii) Digital type time switch 32 Amps 3P module, DIN 24 hours programmable every 1 minutes with 28 memory complete with contactor and other accessories-01 No.
Supply & jointing heat shrinkable straight through joint suitable for LT 1100 Volt grade XLPE cable of size 400/500 Sq mm 3.5 core complete with treating of cable to make ready for jointing etc all as specified and as directed by Engr-in-Charge. Make : 3M / Denson/Reychem
All as per srl item No. 21 here in before but suitable for cable size 240 to 300 sq mm Make : 3M / Denson/Reychem.
All as per item No. 21 here in before but suitable for cable size 150-185 sq mm.Make : 3M / Denson/Reychem
All as per Srl item No. 21 here in before but suitable for cable size 70-120 sq mm Make : 3M / Denson/Reychem
All as per Srl item No. 21 here in before but suitable for cable size 25-50 sq mm Make : 3M / Denson/Reychem
All as per Srl item No. 21 here in before but suitable for cable size 6-16 sq mm Make : 3M / Denson/Reychem
Supply & jointing heat shrinkable end termination joint kit suitable for LT 1100 Volt grade XLPE cable of size 400/500 Sq mm 3.5 core complete with treating of cable to make ready for jointing etc all as specified and as directed by Engr-in-Charge. Make : 3M / Denson/Reychem
All as per srl item No. 27 here in before but suitable for cable size 240 to 300 sq mm Make : 3M / Denson/Reychem
All as per item No. 27 here in before but suitable for cable size 150-185 sq mm.Make : 3M / Denson/Reychem
All as per Srl item No. 27 here in before but suitable for cable size 70-120 sq mm Make : 3M / Denson/Reychem
All as per Srl item No. 27 here in before but suitable for cable size 25-50 sq mm Make : 3M / Denson/Reychem
All as per Srl item No. 27 here in before but suitable for cable size 6-16 sq mm Make : 3M / Denson/Reychem
M&L for galvanised steel tube, light grade with all fitting complete laid in trenches/on floors of 150 mm bore of make : .
All as per item No 33 above but 100 mm bore.
All as per item No 33 above but 80 mm bore.
All as per item No 33 above but 50 mm bore.
All as per item No 33 above but 40 mm bore.
Taking down and dismantling cross arms bracing supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, any shape or size as indicated or directed by Engr-in-Charge
Dismantling insulators any type, any size complete all as spefied and as directed by Engineer in charge
Dismantling stay assembly complete including demolition of concrete etc complete all as specified and as directed by Engineer in charge.
Dismantling concrete poles/steel tubular poles, struts of any size all as specified and as directed by Engineer-in-Charge.
Dismanting earth wire or service feeder or distributor span complete all as specified and as directed by Engineer-in-charge.
Dismantling ACSR conductor from poles of any height complete all as specified and as directed by Engineer-in -charge.
M&L in repalcement of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9.00 meter long complete all as specified and as directed by Engineer-in -charge.
M&L for cross arms bracing supports, clamps, and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot drilling holes for bend in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint (for brackets, MS clamps) complete all as specified and as directed by Engr-in-Charge.
Straightening and Stringing only of aluminum conductor steel reinforced (ACSR) conductor upto 3 to 6 wire on existing pole and binding with the new aluminium wire binding wire 2 mm dia (the new ACSR conductor to be measured and paid separately) conductor as per site requirement all as specified and as directed by Engr-in-Charge.
M&L ACSR conductor any size/any type drawn on fixed to insulator on the pole of any height complete as with permissible sags for OH Conductor all as specified and directed by Engr-in-Charge.
M&L Galvanised steel wire 4.0 mm dia for continuous earth wire and Cradles hexagonal/rectangular shall be provided and securely fastened to each pole and connected with earth ordinarily and cradle guarding where required complete all as specified and directed.
M&L in replacement of pin type, porcelain, vitreous, brown insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed by Engr-in-charge
M&L shackle type, porcelain, vitreous, brown, 75 mm in height and 90 mm maximum dia for 1100 volts grade working pressure insulator including galvanized mild steel straps, washers, insulators bolts, washers and nuts complete all as specified and directed by Engr-in-charge
M&L stay assembly complete with 16 mm stay rod and as in electrical plate No.1 complete (loop type insulator ,stay clamps,excavation and concrete mesured separately.
M&L loop type insulator ,vitreous porcelain white ,brown or green of size 65x90mm complete all as specified and as directed by Engineer -in-charge
M&L in replacement of galvanised stay strand of size 7/4mm complete all as specified and as directed by Engineer-in-charge
M &L in replacement of lugs/thimbles at termination of LT cable by cutting the end portion and removing insulation and fixing new aluminium lugs /thimble properly with crimbing tool of size 185 -400 sq mm complete.
All as per srl item No. 55 here in before but for cable size 50-120 sq mm
All as per srl item No. 55 here in before but for cable size upto 35 sq mm .
Cutting and trimming of tree branches on any type of surface and height to clear OH lines in the area of LT OH lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of tree) and removal of the trimmed branches of trees and depositing the same where directed including providing the necessary ropes/cutting tools, safety equipment like helmet etc as per safety norms (IE Rules) all as specified and directed by Engr-in-Charge.
Material and labour for preparation of old painted / rusted surfaces of steel tubular LT poles 9 mtrs long type 410 SP-31 and applying one coat of aluminum paint (1st quality) incl cross arms and channel, angle fitted on the pole incl wiriting pole numbers and cutting vegetation growth all around and on the poles up to 1 mtr radius complete all as specified and directed.
M&L for painting to PCC/steel poles of any type and any size with a coat of synthetic enamel paint with white /blue30 cm wide strip upto the height of 1.5 mtr above ground level and marking the pole No in 4” dia yellow paint circle complete all as specified and directed by Engr-in-Charge.
M&L for augering of holes in true horizontal position under road /pavement by means of mechanical rig after doing ultrasound technique to prevent any damage to existing cables/pipe lines coming in route 1.5 Mtr deep and not exceeding 50 Mtrs long including laying HDPE pipe of 150mm dia complete.
Supply and fix in replacement MCCB 400 Amps 4 pole 36 KA 415 Volts 50 Hz with thermal and magnetic adjustable settings including taking out old existing unserviceable MCCB from panels etc complete all as directed. Make : Havells / Legrand/ Seimens
All as per srl item No. 61 here in before but 320 Amps 36 KA Make : Havells / Legrand/ Seimens
All as per srl item No. 61 here in before but 250 Amps 36KA Make : Havells / Legrand/ Seimens
All as per srl item No. 61 here in before but 200 Amps 36 KA Make : Havells / Legrand/ Seimens
All as per srl item No. 61 here in before but 160 Amps 25 KA Make : Havells / Legrand/ Seimens
All as per srl item No. 61 here in before but 125 Amps 25 KA Make : Havells/ Legrand/ Seimens
M&L for defect rectification LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 400 Sq mm 3.5 core. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggre gate as in foundation/post hole complete all as specified.
M&L for PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of pole, stay incl frame work where reqd all as specefied and directed.
PCC (1:2:4) type B-I coping with 20 mm graded aggregate for poles complete all as specified and directed.
Supply and fixing in replacement of Vertical type load line distribution board, double door, 8 ways, AC 3 Phase, 415 volts, TPN, bus bar 200 Amps rating and earth bus & din rail suitable for MCCB as incomer complete including cutting chasing the existing wall for fixing the DB and making good the disturbed surface of wall and matching with existing surface of wall and making cable connection with suitable size lugs, making electrical connections of existing submain/circuit wiring, earth wire all as specified and directed by Engr-in-Charge. Make : Havells Cat No. DHDLVDRWGOFO08 and equivalent in Legrand/C&S
Supply and fixing in replacement of MCCB, 3 pole, 100A, 10 KA with fixed thermal & magnetic settings including making electrical connections with suitable size aluminium/copper lugs etc all as specified and directed by Engr-in-Charge. Make: Havells/Legrand/C&S
Supply and fixing in replacement of ACB 1000 A, 4 Pole, LT 415 V, 65 KA breaking capacity with Electrical draw out, Micro processor release (IPR2 04 Pole) with auxiliary switch 6NO+6NC, Main CTs, safety shutters, 36 way auxiliary isolating contacts and horizontal terminal type complete including disconnecting and taking down the existing unserviceable ACB any type and making necessary electrical connections including making necessary fixing arrangements in the existing panel complete all as specified and directed by Engr-in-Charge. Make:- C&S Cat Pt No. WM10S4P*MP3.1(S) or equivalent in L&T/Legrand.
Supply and fixing in replacement MCCB 63 Amps, 4 pole, 10 KA with fixed thermal & magnetic settings including making electrical connections with suitable size aluminium/copper lugs etc all as specified and directed by Engr-in-Charge. Make: Havells/Legrand/C&S.
Supply and fixing in replacement MCB TP 40A, 10KA, 415 Volts 50 Hz 'C' series. Make : Havells / Legrand/ C&S
Supply and fixing in replacement MCB SPN 40A, 10KA, 230 Volts 50 Hz 'C' series. Make : Havells / Legrand/ C&S
Supply and fixing in replacement MCB SP 6-32A, 10KA, 230 Volts 50 Hz 'B' series. Make : Havells / Legrand/ C&S
M&L for LT line separator/spacer 4 ways made out of heavy duty PVC suitable for 1100 V grade complete with fixing on OH line all as specified and directed by Engr-in-Charge.
Same as item No. 78 above but 3 ways
Same as item No. 78 above but 2 ways
M&L Junction box outdoor in replacement type, 3 phase 415 Volts of size 350x250x150 mm made out of hot press moulded SMC front openable hinged type including 4 Nos. Al bus bars mounted on insulators heavy duty of rating 32 Amps with necessary fixing arrangements to pole with MS calmps, nuts, bolts etc of size 25 x 4 mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. Make : Sintex/Hensel/L&T
M&L in replacement Junction box outdoor type, single phase 230 Volts of size 300x200x105 mm made out of hot press moulded SMC front openable hinged type including 2 Nos. Al bus bar mounted on insulators heavy duty of rating 32 Amps with necessary fixing arrangements to pole with MS calmp, nuts, bolts etc of size 25 x 4 mm duly painted with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. Make : Sintex/Hensel/L&T
Supply and fixing in replacement bus bar chamber of 400 Amps rating 4 ways, 3 phase 4 wire 440 volts, 50 Hz, 10KA grading made up of sheet steel (CRCA) of not less than 1.6mm thick duly powder coated including suitable size and length of 04 Nos aluminium/copper bus bars, duly colour coded for 03 phases and 01 nuetral and duly mounted on insulators, with front openable door with locking arrangement (door to be provided with rubber gasket) and including earth bar/terminal including necessary fixing arrangements like PCC foundation, grouting, MS angle, clamps, nuts, bolts etc for fixing the same on wall/floor as directed by Engr-in-Charge. Make: Havells/L&T/Legrand
M&L for welding hinges to existing panel board with existing shutters and fixing to panel board complete all as specified and directed.
M&L for replacement of shutter of with 3 mm thick CRCA sheet as per exisitng size to match with the existing panel and welding hinges and fixing complete all as directed by Engr-in-Charge.
M&L for painting of existing LT panel board with spray gun with paint to match with the existing colour/surface complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement glands for cable upto 240 Sqmm size double compression type complete including removing and refixing cables from LT panel for fixing the glands all as specified and directed.
Supply and fixing in replacement LED street light fitting of 90 Watt, 5700K complete including all fixing accessories complete made up of pressure die cast aluminium housing with high power LED as lighting source and lens with heat resistant toughened glass & IP 66 protection with 10 KV Built-in Surge Protection Devicecomplete complete with driver and all accessories fixed on and including GI bracket of sufficient length and size with all nuts, bolts, washers etc duly connection with & including three core flexible copper cable including taking down the existing light fitting complete all as specified and directed. Make: Havells Cat No. ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or equivalent in C&S/Wipro.
Supply and laying in replacement or fixing or passing through pipe, 1100 volts 2 core PVC insulated solid aluminium flat conductor for service connections of size 6 sq. Mm complete all as specified and directed.
All as per item No 91 above but of size 10 sqmm 2 core.
M&L for earthing in replacement of with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I of 2009 and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed by Engr-in-Charge.
M/s Adhikari construction co.
Commercial Traders
J B Electricals
H.B. Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .