| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest tender | |
| 2 | L2₹17.9 L+₹2.2 L (14.1%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹19.4 L+₹3.7 L (23.9%)Rejected-Finance 01 TIWARI BAZAAR GONDA ROAD TIWARI BAZAAR GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L3 | Rejected-Finance Not being lowest tender |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
3 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA
GE AF TA GWALIOR-474020
PROVN OF E/M RELATED CERTAIN SANCTIONED WORKS IN TECH AREA AT AF STN GWALIOR
2021_MES_491993_1
8900/1356/GWL/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) TA Gwalior
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF TA GWALIOR
₹36,000
Yes
11 Feb 2022
2 Dec 2021
11 Jan 2022
2 Dec 2021
3 Jan 2022
20 Dec 2021
60 days
Amount
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 1.5 TR (4500 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , minimum 3 star rating EER of 3.2 and above complete comprising of following :- Make : Blue Star, Model No- VLTU Fixed Speed AC 3 star or equivalent make as per Appendix 'A' to PS. (a) Indoor unit copper coil with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising of Compressor with motor, air cooled copper condenser with fan and motor and unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 1.5 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 2 TR (6000 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , minimum 3 star rating EER of 3.2 and above complete comprising of following :- Make:- Blue Star, Model No- AATX Fixed Speed AC 3 star or equivalent make as per Appendix 'A' to PS. (a) Indoor unit copper coil with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising of compressor with motor, air cooled copper condenser with fan and motor and unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 2 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.
Supply, install, commissioning and testing of split type Air conditioner of capacity 3 TR (9000 K Cal/hr) Three phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , minimum 3 star rating EER of 3.2 and above complete comprising of following :- Make:-Blue Star, Model No- FMA36MUP3 or equivalent make as per Appendix 'A' to PS. (a) Indoor unit copper coil with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising . Compressor with motor, air cooled copper condenser with fan and motor and unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wallas per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 3 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.
M & L for sub main wiring with two runs of single core 4 Sq.mm for phase conductor and one run of single core 4 Sq.mm as earth continuity conductor of multi stranded copper conductor FR-LSH PVC insulated unsheathed cable conforming to IS : 694 drawn through in & including PVC casing & capping with fixing accessories on wall/roof surface as per relevent IS standard not less than 25 mm width and all as complete specified and directed. Note: Two run of main wire one run, one run of earth wire and one run PVC caping/casing shall be measure as one unit.
M & L for sub main wiring with two runs of single core 6 Sq.mm for phase conductor and one run of single core 6 Sq.mm as earth continuity conductor of multi stranded copper conductor FR-LSH PVC insulated unsheathed cable conforming to IS : 694 drawn through in & including PVC casing & capping with fixing accessories on wall/roof surface as per relevent IS standard not less than 25 mm width and all as complete specified and directed. Note: Two run of main wire one run, one run of earth wire and one run PVC caping/casing shall be measure as one unit.
M & L for sub main wiring with three runs of single core 4 Sq.mm for phase conductor and one run of single core 4 Sq.mm as earth continuity conductor of multi stranded copper conductor FR-LSH PVC insulated unsheathed cable conforming to IS : 694 drawn through in & including PVC casing & capping with fixing accessories on wall/roof surface as per relevent IS standard not less than 25 mm width and all as complete specified and directed. Note: Three run of main wire one run, one run of earth wire and one run PVC caping/casing shall be measure as one unit.
Supply and Fixing industrial type socket with plug top, Single pole and netural and earth plug 240V, 20 Amps with steel enclosure and one MCB SPN 20 Amps complete all as specified and directed.
Supply and Fixing industrial type socket with plug top, tripple pole and netural and earth plug 415V, 32 Amps with steel enclosure and one MCB TPN 32 Amps complete all as specified and directed.
Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 150 V to 285 V with output voltage stablized at 200V to 245 V with accuracy of + 1% and of capacity 5.0 KVA complete all as specified and directed Make:- V-Guard, Model No-VND-500, or equivalent make as per Appendix 'A ' to PS.
Supply & Installation of hot dip galvanized steel high mast lighting system of 16 meter in two section suitable for 55 m/sec wind speed, soil bearing capacity not less than 10T/Sqmtr at 2 metre depth with rising & lowering system comprising, head frame, luminaries carriage suitable for 08 Nos luminaries in symmetrical arrangement, double drum winch, 5mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, complete lightening protection system alongwith all wiring materials like PVC insulated sheathed flexible cable of suitable copper conductor of 2.5 Sqmm, Lugs for connecting the luminarie from the Junction box to individual luminari & MCB in base compartment, the rates also includes 4 X 16 Sqmm AL armoured XLPE and 3 X2.5 Sqmm copper cable for Motor and power supply from the panel to bottom of High Mast. Note :- (1) The rate quoted against the item is inclusive of necessary earth work PCC/RCC with required reinforcement as recommended by OEM. (2) The contractor will submit detailed drawings of PCC/RCC foundation and obtain prior approval of the accepting officer before commencement of work
Supply, fixing, installation, commissioning and testing aviation obstruction lights ( on and over hangers / high rise buildings) comprising of integral LED aviation light comprising of die-cast aluminium alloy housing , with polycarbonate enclosure and including lamp and necessary connection with electric source complete all as specified and directed Make :- Bajaj Cat part No. BGAV 302 LED or equivalent in Havells/Philips
Supply and fixing LED flood light fittings model specially design for High Mast lighting purpose to focus proper light from 16 Mtr height High Mast. Fitting should be Matt black polyster powder coated pressure-dia cast aluminium housing frame with heat resistant toughened clear glass fixed with SS screws. LEDs to be provided with secondary lens optic to get optimum optical performance, built in surge protection alongwith external surge protection for additional safety. Luminarie is to be provided with MS mounting bracket fixed on pressure die-cast aluminium housing for aiming adjustment. System wattage should be 300W, required luminous flux should be minimum 33000 Lm, Luminarire efficacy should be at least 110L/W, correlated colour temperature should be 5700K, required colour rendering Index should be greater than or equal to 80, Maintenance of lumen output-50,000hrs, operating temperature range should be between -20 degree celcious to + 45 degree celcious. Beam angle of luminarie should be 33 degree. Power factor greater than 0.95 complete all as specified and directed by Engr-in-Charge. Make :- Havells/Bajaj/Philips
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor cross sectional area 16 Sqmm , 4 core laid in trenches / duct / pipe/pole including required lugs etc complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized iron strip of 25 x 4mm as earth continuity conductor by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electric plate No 5, of SSR Part - I, 2009 & all as specified, testing on completion including provision of earth lead protected by 40 mm dia GI pipe medium grade & watering pipe 20 mm medium grade including all excavation and earth work in any type of soil, PCC pit (1:3:6) type C1 with RCC cover, charcoal, salt, funnel etc including making good disturbed surfaces of wall, floor complete all as specified and directed. Note : ( i ) The rate is inclusive of cost of earthing lead of 25 x 4mm and GI protection pipe 40mm size upto 7.5 m length from the top edge of the GI plate electrode.. (ii) Irrespective of what is shown on plate No 5 of SSR Part-I /2009, the earthing pit shall be precasted PCC (1:3:6) type C1 and the cover of earthing pit shall be of precast RCC (1 :2 : 4) type B1 with suitable handle fushed with surface all as specified. (iiii) The rates quoted by the contractor is deemed to be inclusive of cost of MS sheet of size 300mmX 300mmX3mm size, fixed with necessary nuts and bolts on angle iron of size 40X40x5mm & length 60cm and grouted in the ground with PCC (1:3:6) using 20mm grade stone masonery of size 200mmX200mmX250mm embedded below ground level including necessary earth work.for marking the result and its purpose of use
Supply and fixing of DWR double wall corrugated pipes 40 mm dia for cable protection complete all as specified and directed.
Design, fabricate, supply, install, test and commissioning of factory made floor mounted LT cubical panel board outdoor type (double door) made out of 3.15mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opening and locking arrangement 415Volts, 3 phase, 50 Hz having aluminium bus bar of capacity 200 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit current with stand minimum 85 KA for one second complete connection from bus bar to breakers with suitable copper cable , panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc. The panel board shall be powder coated and red oxided primed. The panel board shall be fabricated from the reputed CPRI approved firm and shall be suitable to accommodate and supply and fixing of the following complete all as specified and directed :- (A) Incoming :- (a) MCCB 4P, 63 AMP, 16KA -01 No (b) The following items are provided in one compartment :- (i) Digital Voltmeter - 01 No (ii) Digital Ameter - 01 No (iii) Three Indiaction LED Lamp with wiring - Set of 03 (B) Out going :- (a) MCCB TPN 4 Pole 32 A - 02 Nos (b) Power Contractor 45 Amps - 1 Nos. (c) Power contractor 15 Amps-01 Nos (d) Digital Type GIC Astro Timer Switch 230 Volts -2 (Make :- Havells/L&T/Indoasian) (e) MCB SP 06 Amp - 04 Nos
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out forming bottom surface for laying cables/ Protection pipes etc. complete all as specified and directed.
Returning, filling in trenches with excavated soil in layers not exceeding 25cm including watering well ramming complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50m and depositing where directed at a level n.exc 1.50 m above the starting point complete all as specified and directed
Disconnecting , dismantling and taking out old existing underground air field lighting cable of any description and in any position from the trenches/ducts with protection pipe etc if any complete all as specified and directed.
Laying only airfield lighting cable of any description and any size in trenches/duct including connecting, jointing and testing etc. complete all as specified and directed Note :- Old retrieved cables in serviceable condition from taking down shall be used in the work
Supply and fixing epoxy straight through joint suitable for single core cable upto 35 sqmm, 3.3 KV complete all as specified and directed.
Taking down and refixing isolation transformer including tapping the joints with self amargamating high tension insulating tape and setting the direction of light and testing complete all as specified and directed.
Material and labour for point wiring for one Light and fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including conceled/Surface PVC conduit (Medium grade) of size not less than 20mm dia with sunken type pressed steel terminal box 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
One light /Fan point controlled by one way switch .
All as per item No.24.01 here in before but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch / socket point as directed .
Supplying & fixing switch flush type, 5/6 Amps, single pole, one way, 230 volts, AC circuit complete all as specified and directed.
Supplying & fixing for switch socket outlet combination, five pin, 5 Amps and 15 Amps multipurpose (3 pin 15 Amps and one pin 5 Amps controlled by one switch )
Supply & fixing ceiling rose , surface backelite 65mm x 50mm size with three terminals all as specified and as directed by Engineer-in - charge.
Supply and fixing ceiling fan 1200mm sweep heavy duty of make Havells /Crompton Greaves/Bajaja complete all as specified and directed.
Supplying & fixing LED batten fitting 20 watt complete with roumd block etc , incl PVC gutties and flexible wire and connecting to ceiling rose complete .Model Wipro Garnet 20 W , D 532065 OF Wipro or equivalent model of philips /Bajaj /Havells .
Supplying, fixing in repair & testing decorative recess mounting 36 watt LED full out put luminaries suitable for Armstrong ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed. Make :Bajaj cat part No BZRSQL 36W GZ1 NW "SKYLUX' Racess mounted 2x2 LED or equvivalent in make Philips/CG
Supply & fixing sheet metal enclosure for double door MCB DBs phosphatised power coated , single pole & Neutral (SPN) Suitable for 8 Way , 240 volts IP 43 & IK 09 fixed on wall with din rail , neutral and earth bar , in proper position all as directed by the Engineer -in - Charge . (Make - Legrand Cat No. 6077 11or equivalent siemens / ABB )AMCB Single Pole and Neutral (SPN) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position all as directed by the Engineer-in-Charge.
Supply and fixing MCB/Isolator SPN 40 Amps having current rating 10 KA complete all as specified and directed.
Supplying & fixing in repair MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.
M& L for sub main wiring with two runs of single core 6 sq mm for main wire and one run of single core 6 sq mm as earth wire multi stranded copper conductor FR PVC insulated unsheathed cable conforming to IS :694 drawn through and including in surface/recessed as required in PVC conduit conforming to IS : 9537 (Part-3 ) and ISI marked not less than 25 mm dia and all accessories all coforming to IS specification complete. Note: Two run of main wire one run, one run of earth wire and one run of conduit shall be measure as one unit. Cost for cutting chases shall be included in quoted rate.
Uma engineers
M/s A.K. Trading Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .