Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹5,100
Closing Date
17 Dec 2020, 3:00 pmClosed
EXECUTIVE ENGINEER (SDW) IV STP Kondli Delhi
EXECUTIVE ENGINEER (SDW) IV STP Kondli Delhi
Electrification of newly build office and existing office of EE C Dr IX X at Jagriti
2020_DJB_197319_1
NIT-6 (2020-21)
Open Tender
Electrical Works
Works
60 days
EXECUTIVE ENGINEER (SDW) IV STP Kondli Delhi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
A/c No. 50448339804
₹5,100
29 Dec 2020
8 Dec 2020
17 Dec 2020
8 Dec 2020
17 Dec 2020
8 Dec 2020
Electrification of newly build office and existing office of EE( C) Dr. IX , X & Jagriti SPS by carrying out the following works:-Supply of Decorative ultra slim aluminium square profile24 watt LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. Make:- Bajaj/ Crompton/Philips/Havells
Supply of New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. 60 W Make:- Bajaj/ Crompton/Philips/Havells
Supply of heavy duty exhaust fan size 300 mm Make:- Bajaj/ Crompton/Philips/Havells
Supply of Ceiling fan 1200 mm Make:- Bajaj/ Crompton/Philips/Havells.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. DSR(E&M) No.- 1.33
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps DSR(E&M) No- 2.12.1
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required DSR(E&M) No -1.38
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole DSR(E&M) No.-2.10.1
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C, DSR (E&M ) No.-1.3.2
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR (E&M ) No.-1.5
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire. DSR (E&M)No. -1.14.5
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. DSR(E&M) No- 1.41
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep, DSR(E&M) No.- 1.50.1
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm0 with 1.5 sq mm FRLS PVC insulated, copper conductor, single core cable etc . as required. DSR(E&M) No.- 1.44
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door DSR 2018 E&M) No.-2.3.2
Bansal Engineers and Traders
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .