Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance ROOM NO A 46 GALI NO 11 GANESH MURTHY NAGAR PART NO 3 CAPT PRAKASH PETHE MARG CUFFE PARADE COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | Admitted-Finance |
| 2 | Admitted-Finance 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | Admitted-Finance |
| 3 | Rejected-Technical ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | Rejected-Technical Enlisting authority un-enlisted the firm |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
29 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Asvini
AGE (I) Asvini
PROVISION OF CERTAIN SANCTIONED WORKS AT INHS ASVINI
2021_MES_475383_2
8330/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) Asvini
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
AGE (I) Asvini
₹20,000
Yes
10 Nov 2021
12 Oct 2021
1 Nov 2021
12 Oct 2021
29 Oct 2021
12 Oct 2021
60 days
Amount
SCHEDULE 'A' PART I ( B/R ITEMS) Excavation in post holes (or similar holes) each n.exc 0.65 cum getting out in soft/ loose soil, returning filling in, and ramming earth or broken rubble mixed with earth around in layers n.exc. 25 cm and removing surplus soil to a distance n.exc 50m and making good disturbed surfaces as per existing complete all as directed.
Excavating over areas n exc 1.5m in deep and getting out in hard/dense soil completes all as specified.
Returning filling in , including spreading, leveling, watering and well ramming in layers not exc 25 cm.
Removing excavated materials (soils) outside MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
M&L for hardcore of broken stone or boulders of gauge n. exc 63mm, deposited, spread and leveled in layers n. exc 15cm thick watered and rammed to true surface complete all as specified.
M&L for PCC 1:3:6 type C2 using (40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified.
M&L for PCC 1:2:4 type B2 using (40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified.
M&L for PCC 1:2:4 type B1 using (20 mm graded stone aggregate) in roof kerbs of mud stops, rounded or chamfered on edges complete all as specified.
M&L for RCC 1:1½:3 type A1 (using 20 mm graded stone aggregate) in foundations including rafts, footing, bases of columns, plinth beams etc. complete all as specified.
M&L for RCC 1:1½:3 type A1 (using 20 mm graded stone aggregate) in walls, retaining walls, basement walls, ballast walls and the like ; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified.
M&L for RCC 1:1½:3 type A1 (using 20 mm ground stone aggregate) in slabs supported on walls, beams and columns in floors, roofs ,landings ,balconies canopies ,deck slabs and in shelves and the like complete all as specified.
M&L for RCC 1:1½:3 type A1 (using 20 mm graded stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5 m span.
M&L for 100 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in ramp and finished even and smooth without using extra cement complete all as specified
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams etc, vertical or to batter for rough finished surfaces of concrete flat.
M&L for form work to faces of retaining walls, abutments, and vertical or to batter for rough finished surfaces of concrete flat.
M&L for form work to sides & sofits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exc 200mm thick ( horizontal or sloping) for rough finished surfaces of concrete flat.
M&L for form work to sides & soffits of beams for rough finished surfaces of concrete flat.
M&L for TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with the clips.
Ditto- all as per item No 18 above but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders.
S&F 80mm dia steel pipe for structural purpose as in vertical posts , cutting tops to shape including necessary drilling, bolting or riveting and embedding post in concrete fixed with angle cleats or other connceting plates of Gde Fe-410-Scomplete all as specified
M & L for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for siding doors; fixed with angle cleats or other connceting plates of Gde Fe-410-S
S&F mild steel plates ( plain or chequered ) channels, square cut or notched ( ordinary and counter sunk ) forming holes, without any attachment including all necessory drilling, bolting,riveting or welding conforming to Fe-290 (Gde E-165) complete all as specified.
M&L for rolled mild steel in framed work as in door or gate of angle or other section with gusset plates, rails, braces etc complete,drilled for fixing of steel sheeting or other covering. Doors/gates to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings( exclusive of steel sheating or other covering,running rails and guides) and hanging also fastening and fixing including welding and locking arrangement , handles complete conforming to Fe-410-0 or Fe 310-0.
M&L for collapsible steel gates,top hung,consisting of channel pickets,pivoted flat bars,top and bottom runners,brass handles etc.as specified,erected in position and securing runners with hold fasts and brackets complete
S&F MS framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors, ladders, framed balusters, walk ways, railings etc conforming to Fe 410-0 or Fe 310-0 complete all as specified
S & F pre-painted galvalume aluminium zinc coating corrugated steel sheet 0.5 mm thick of an approved colour having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws including taking down exiting roof sheet of any description etc complete all as specified and as directed
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) for frame and shutters of doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified. Note: - (i) Glass panes/ wire mesh will be measured & paid separately. (ii) The rate quoted shall be inclusive of the cost of neoprene beading, glazing pins, screws, handles etc however will not be weighed for arriving the weight.
S&F rotational moulded polyethylene water storage tank 2000 Ltr capacity, (cylindrical vertical with closed top) including all connections for inlet, outlet, overflow and washout etc hoisted and fixed in position all as specified in SSR Part-I including BMC approved PVC cover with locking arrangement complete all as specified.
S&F 15 mm bore GI tubing medium grade with all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc fixed to walls and ceilings or laid in floors with suitable size GI clamps complete all as specified.
Ditto- as per item No 29.00 above but 20mm bore.
Ditto- as per item No 29.00 above but 25mm bore.
Ditto- as per item No 29.00 above but 40mm bore.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:6) and finished even & smooth without using extra cement completed all as specified.
M&L for preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing debris out side MD land. Note: The place of disposal shall be find out by the contractor.
M&L for 12 mm thick plywood, grade BWP, type BB as in wall mounting cupboard, work station, partion wall, table top including drawers etc including fixing 0.9 mm thick decorative laminated type-I of surface finish, coloured and pattern as approved to exposed surfaces , fixed with adhesive as per makers instructions including providing 3 thick 1st class hard wood (Teak) beading to all exposed faces of the board complete all as specified.
M&L for 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination on both sides fixed with screws to timber frame work complete all as specified.
S & F brass drawer handles projecting drop 50mm to 65mm on screwed plate complete all as specified.
S & F brass multipurpose drawer lock of size 50mm x 35mm x 32mm complete all as specified.
S & F 75mm stainless steel handle complete all as specified.
S&F hasp and staples of 75 mm size, safety type, and aluminum anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws, ISI marked.
S&F extruded aluminium alloy handles, fabricated type, anodised 75 mm size, ISI marked.
S & F aluminium powder coated heavy duty telescopic sliding channel 30mm wide with rollers fixed with cadmium plated screws complete all as specified.
M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
S&F 6.3 mm thick sheet glass ordinary quality and glazing in squares exc 0.5 Sqm in each pane complete all as specified.
S&F 4.8 mm thick sheet glass ordinary quality frosted on one side and glazing in squares exc 0.5 Sqm in each pane complete all as specified.
M&L for 0.9 mm thick decorative laminate type I of surface finish, colour and pattern as approved fixed with approved adhesive as per maker's instructions.
M&L for second class hardwood (SAL) plain, solid straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified.
M&L for 25 mm thick second class hard wood (sal) plain, framed panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) and fitted to chowkat.
SCHEDULE 'A' PART II (E/M WORKS) Taking down carefully copper / aluminium point wiring (light, fan socket or power) through steel / PVC conduit / casing caping including complete fittings such as switches, ceiling roses, pendants, regulators, sockets, buzzer, bell, switch sockets, etc removing and making good to the disturbed surfaces of walls/ceiling etc, with its original specification complete all as specified and directed.
M & L for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLSH copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including suitable size surface PVC casing caping (ISI marked) with all accessories and terminated in and including surface PVC modular box with cover plate and frame of sutable size including 1.5 sqmm size PVC insulated, unsheathed, multistranded FRLSH copper conductor cable for continuous earth conductor (using green colour) and connecting to earth dolly for One light/ fan / bell point controlled by one switch 5 Amp, SP, one way 240 volts.
Ditto- all as per item No 9 above but One 3 pin 5 Amps switch socket on independent PVC modular box with cover plate and frame.
Ditto- all as per item No 53 above but One 3 pin 5 Amps socket outlet on same board with other switches
M & L for point wiring with 4 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLSH copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including suitable size surface PVC casing caping (ISI marked) with all accessories and terminated in and including surface PVC modular box including cover plate and frame of sutable size including 4 sqmm size PVC insulated, unsheathed, multistranded FRLSH copper conductor cable for continuous earth conductor (using green colour) and connecting to earth dolly for one industrial metal clad power socket on independent board for AC
S & F Ceiling rose , surface bakelite 65x50mm , two to three terminal. all as directed. Make: Anchor
S & F switch modular one way, 6 Amp, 1 module (ISI marked) complete all as specified.
S & F switch modular one way, 16 Amp, 1 module (ISI marked) complete all as specified.
S & F modular Socket 2/3 pin, 6 Amps, 2 module complete all as specified.
S & F modular Socket 6/16 Amps,6 pin, 2 module complete all as specified.
S & F modular stepped type fan regulator, 120 Watt, 2 module complete all as specified.
S & F MCB TPN DB 8 Way, (8+24) suitable for flush mounting and surface mounting, conforming to IP 43 - IK 09 with acrylic door with 100 Amp copper bus bar for each phase, complete with din rail, Neutral and Earthing bar complete all as specified Make:- Legrand cat part No. 507682 or Equivalent model of Havells/L&T/ C&S Electric Ltd/ABB.
S & F MCB 240V, 10KA 'C' curve, of Single Pole and 6Amp to 32Amp current carrying capacity and fixed in the DB complete all as specified
S & F MCB 240V, 10KA 'C' curve, SPN 40Amp to 63Amp current carrying capacity and fixed in MCB DB complete all as specified
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified. Make : Bajaj or equivalent Crompton/Philips.
S & F Sub main wiring with two single core (Red and Block Colour) PVC insulated unsheathed FRLS copper conductor 1100 volt grade multistandard cable of size 6.0 sqmm drawn through and including PVC casing capping of size 25x12mm/32x12mm as required including accesssories (ISI marks), one run of single core (Green colour) PVC insulated unsheathed FRLS copper conductor cable 1100 volt grade multistandard of size 6.0 sqmm for earth continuity wire and connected of common earth dolly complete all as specified. Note:- One run of PVC casing capping 25x12mm/32x12mm, three run of 6 sq mm copper conductor cable for phase/ neutral shall be measured and paid as one unit.
S&F exhaust fan 300mm sweep, heavy duty metalic body, Industrial, heavy duty, 1440 RPM suitable for working on 230 V, 50 HZ, AC supply complete with louvers, fixed with suitable size GI bolts, nuts and washers duly grouting new hanger fasteners of size 50mm x 10mm - 4 Nos including connecting up with 0.75 Sq.mm. size 3 core PVC insulated flexible cable with multi-stranded copper conductor from ceiling rose to connector of exhaust fan including making hole in brick wall of suitable size and making good disturbed surfaces as per existing complete all as specified. Make - Crompton Greaves,Almonard, Usha, Khaitan, Bajaj.
S & F ceiling fan 5 star rating, 230 Volts, 50 Hz, 1200 mm sweep including blades, down rod, modular regulator, and all accessories including connecting up with 0.75 Sq.mm. size 3 core PVC insulated flexible cable with multi-stranded copper conductor from ceiling rose to connectorcomplete all as specified and directed
Taking down carefully serviceable pump and motor of capacity 2 HP , starter, MCB box etc after disconnecting electrical connection and transporting within 1 KM and refixing in new location, making electrical connection with suitable size copper conductor cable PCC foundation, steel frame for mounting pump, nuts, bolts, washers and complete plumbing work as per existing and testing after installation complete all as specified.
Taking down carefully 1200 mm sweep ceiling fan after disconnecting electrical connections and refixing in new location, making electrical connection with suitable size copper conductor cable including providing down rod of 20mm dia of suitable length complete all as specified.
jkconstruction
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .