Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Qualified | Qualified |
| 2 | Qualified | Qualified |
| 3 | Qualified 1ST FLOOR MAYUR APPARTMENTS 3A LOUDON STREET LOUDON STREET KOLKATA WEST BENGAL 700017 | KOLKATA | WEST BENGAL | 700017 | Qualified |
Tender Value
Refer Docs
EMD Value
₹54.3 L
Closing Date
5 Sept 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ramit Anand
Power Grid Corporation of India Limited, 3rd Floor, Contract Services, Saudamini, Plot No. 2, Sector-29, Gurgaon-122001, Haryana, India
Transmission line package TL01 for Part-A: Construction of 220 kV D/C Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part-B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5
Open
Power/Energy Projects/Products
Works
Sikkim
₹25,000
₹54.3 L
7 Sept 2022
27 Jul 2022
7 Sept 2022
29 Jun 2022
5 Sept 2022
29 Jun 2022
7 Jul 2022
Name of Package Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Package No : TL-01
Specification No. : 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5
Completion Period 16 Months
: Transmission Line Package -TL-01 : General guidelines for filling up the Attachments : Transmission Line Package -TL-01 : ORIGINAL
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Specification No.: 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(JV), 3(QR), QR, 4, 4(A), 4(B), 5, 5(A), 6, 7, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 25, 26, 27 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufacture proposed to supply main items.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14-IP.
7 Attachment 20 KMP Declaration : Format enclosed in Volume-III of the Bidding Documents.
8 Attachment 21 Authorization certificate issued by Domestic Manufacturer for selling Domestically Manufactured Iron & Steel Products : Format enclosed in Volume-III of the Bidding Documents.
9 Attachment 22: Affidavit of Self certification regarding Domestic Value Addition in Iron & Steel Products : Format enclosed in Volume-III of the Bidding Documents.
10 Attachment 23 Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
11 Attachment 24: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
12 Attachment 25: Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA : Format enclosed in Volume-III of the Bidding Documents.
13 Attachment 26: Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
14 Attachment 27: Certification by the Bidder per DoE Order in line with ITB Clause 2.1
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Sole Bidder 1 YES
JV (Joint Venture) 2 or More NO
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 0
Whether the bidder is an MSE (Micro & Small Enterprise)
Enter the Name of Registration Authority
Name of Sole Bidder
Address of Sole Bidder
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-3(JV) TL-01 Sole Bidder TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
This Attachment is Not Applicable
Name(s) and Addresse(s) of other partner(s)
Address : #REF!
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
Date : Printed Name : 0
Place : Designation : 16
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-3(QR) TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Qualifying Requirement Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
For our Qualifying Requirements Data, please refer Attachment-QR of this volume.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-4 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby certify that equipment and materials to be supplied are produced in [Enter the name of country where from equipments & material shall be supplied] eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Enter the name of country where from equipments & material shall be supplied] eligible source country.
Date : Printed Name :
Place : Designation :
country. country. [Enter the name of country where from equipments & material shall be supplied] [Enter the name of country where from equipments & material shall be supplied]
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-4(A) TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-4(B) TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-5 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of the items/ sub-assemblies of supply or services i.e. items, whose price is more than 10% of the Bid Price, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Annexure I to Attachment-5 TL-01
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Annexure I to Attachment-5 TL-01
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Details of the proposed sub-contractor/sub-vendor Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-5(A) TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1. We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package:
S.No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name & Address Category
2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract. .
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-6 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Annexure I toAttachment-6 TL-01
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-7 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Details of Alternative Bid)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
No Alternative Bid
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-9 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Work Completion Schedule)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Period in months from the effective date of Contract
Transmission Line Package - TL01
1 Detailed Engineering and drawing submission
a) commencement
2 Procurement of equipment/ components & assembly
a) commencement
a) commencement
4 Manufacturing
a) commencement
5 Shipments & Delivery
a) commencement
6 Establishment of site office
7 Installation at Site
a) commencement
8 Testing & Pre-commissioning
a) commencement
9 Trial Operation
a) commencement
Date : Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-10 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Guarantee Declaration)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that the equipments offered shall have minimum performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-11 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly, we hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : Printed Name :
Place : Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-12 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.The necessary documentary evidence are enclosed :
Sl. No. Name of Materials Value of co-efficient Name of the published index Value of index
I For Ex Works Price Components of Transmission Line Portion
A For Fabricated Tower Parts (including bolts & nuts)
a Steel Blooms, co-efficient a = Steel Blooms of size 150 mm x 150 mm, as published by IEEMA
b. Electrolytic High Grade Zinc, co-efficient b = IEEMA
c. Labour, Co-efficient l= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
Coefficient ‘a’ shall be between 0.51 to 0.57 and coefficient ‘b’ shall be between 0.08 to 0.10 and coefficient ‘l’ shall be between 0.20 to 0.24 and sum of Coefficients ‘a’, ‘b’ and ‘l’ shall be 0.85
B. Line Materials
B1. AL59 Conductor
1 EC grade aluminium ingots, co-eifciant a = 0.80 Monthly average of “Aluminum LME SELLER Settlement Price including Premium of Al Ingots and Customs duty converted in RS./MT” as published by IEEMA
2 Labour, Co-efficient l= 0.05 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
i) Raw Material
A High Tensile Steel Galvanized Wire, coefficient a = CACMAI/ Nationally recognized published index
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
Coefficient ‘a’ shall be between 0.69 to 0.71 and coefficient ‘l’ shall be between 0.09 to 0.11 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
B1. Hardware Fittings
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
B Electrolytic High Grade Zinc, coefficient b = IEEMA
C Manufacture of Basic Metals, coefficient c= Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2001 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.35 to 0.45 and coefficient ‘b’ shall be between 0.04 to 0.06 and coefficient ‘c’ shall be between 0.18 to 0.22 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’, ‘b’, ‘c’ and ‘l’ shall be 0.80
B2 Conductor Accessories
1 Mid Span Compression Joint for Conductor
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
2 Repair Sleeve for Conductor
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
3(c) Bundle Spacer for Conductor
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
ii) Labour, coefficient l = 0.80 Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
3 Rigid Spacer for Jumper
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
4 Spacer Damper for Conductor
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
B4 Earthwire Accessories
4(a) Mid Span Compression Joint for Earthwire
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
B Electrolytic High Grade Zinc, coefficient b = IEEMA
C Manufacture of Basic Metals, coefficient c = Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.35 to 0.45 and coefficient ‘b’ shall be between 0.04 to 0.06 and coefficient ‘c’ shall be between 0.18 to 0.22 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ , 'b' , 'c' and ‘l’ shall be 0.80
4(b) Vibration Damper for Earthwire
i) Raw Material
B Electrolytic High Grade Zinc, coefficient b = IEEMA
C Manufacture of Basic Metals, coefficient c = Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘b’ shall be between 0.06 to 0.08 and coefficient ‘c’ shall be between 0.55 to 0.61 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients 'b' , 'c' and ‘l’ shall be 0.80
4(c) Suspension Clamp for Earthwire
i) Raw Material
B Electrolytic High Grade Zinc, coefficient b = IEEMA
C Manufacture of Basic Metals, coefficient c = Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘b’ shall be between 0.06 to 0.08 and coefficient ‘c’ shall be between 0.55 to 0.61 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients 'b' , 'c' and ‘l’ shall be 0.80
4(d) Tension Clamp for Earthwire
i) Raw Material
B Electrolytic High Grade Zinc, coefficient b = IEEMA
C Manufacture of Basic Metals, coefficient c = Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘b’ shall be between 0.06 to 0.08 and coefficient ‘c’ shall be between 0.55 to 0.61 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients 'b' , 'c' and ‘l’ shall be 0.80
5 Flexible Copper Bond Firm
a EC grade aluminium ingots, co-eifciant a = 0.65 IEEMA
c High Tensile Galvanised Steel wires , co-efficient b = 0.15 IEEMA FALSE FALSE
IEEMA High Carbon Steel Rods , co-efficient b = High Tensile Galvanised Steel wires , co-efficient b =
High Grade Electrolytic Zinc , co-efficient c =
l Labour, Co-efficient l= 0.05 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
II For Ex-works price component of Substation Portion
A AIS Equipment
1 Capacitive VoltageTransformer
a) Raw Material
b) Labour, l= Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
a) Raw Material
b) Labour I= l= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
2 Surge Arrester
a) Raw Material
b) Labour, l= Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
3 PVC/XLPE Insulated Power and Control Cable
a) a=PVC Compound 0.15
b) Published Price of Metal IEEMA
i) Aluminium per MT IEEMA
ii) Copper per MT IEEMA
c) Weight in MT of Metal per kM (Size wise)
4 Substation Structures
i) Lattice Steel Structures & Pipe Structures (including bolts & nuts, washers & foundation bolts)
a) Raw Materials
i) a=Structural steel 0.58 JPC Market Price (Retail) for average Price of Steel Angles of size 50 x 50 x 6 mm of all cities in Rs./MT as published by Joint Plant Committee(JPC).
ii) b=Electrolytic Zinc 0.16 IEEMA
b) Labour 0.11 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
III For Erection Price Component (Transmission Line portion)
1 Installation Price Component [including Civil Works but excluding ‘Supply & Placement of Reinforcement Steel’, ‘Concreting’, Survey, Soil investigation and aviation signal for river crossing towers (if any)]
A High Speed Diesel, coefficient a = Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in)
L Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
Coefficient ‘a’ shall be between 0.20 to 0.24 and coefficient ‘l’ shall be between 0.56 to 0.60 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
2 Supply & Placement of Reinforcement Steel
A High Speed Diesel, coefficient a = Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
L Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
B Manufacture of Basic Metals, coefficient b = Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
Coefficient ‘a’ shall be between 0.09 to 0.11 and coefficient ‘b’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.04 to 0.06 and sum of Coefficients ‘a’, ’b’ and ‘l’ shall be 0.80
3 For Concreting
A High Speed Diesel, coefficient a = Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
L Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
B Manufacture of cement, lime and plaster, coefficient b = Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
C Cutting, shaping and finishing of stone, coefficient c = Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
Coefficient ‘a’ shall be between 0.18 to 0.22 and coefficient ‘b’ shall be between 0.25 to 0.35 and coefficient ‘c’ shall be between 0.18 to 0.22 and coefficient ‘l’ shall be between 0.09 to 0.11 and sum of Coefficients ‘a’, ’b’, 'c' and ‘l’ shall be 0.80
IV Installation price component of Substation Portion
1 Installation price component (including Civil works but excluding ‘supply & placement of reinforcement steel’ and ‘concreting’)
i Labour I= 0.80 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
Invalid Entry !
2 Supply and Placement of Reinforcement Steel
i HSD 0.10 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii Labour I= 0.05 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
iii Manufacture of Basic Metals 0.65 Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
i HSD 0.20 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii Labour I= 0.10 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
iii Manufacture of cement, lime and plaster 0.30 Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in)
iv Cutting, shaping and finishing of stone 0.20 Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-13 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-14 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Integrity Pact is annexed herewith this Volume.
Date : Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (o).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as
having its Registered Office at
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. Package and Specification Number 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 .POWERGRID values full compliance with all relevant laws of the land, rules, regulations, economic use of resources, and of fairness / transparency in its relations with its Bidders/ Contractors.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity, fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personal interest in the Companies/Agencies participating in the Bidding/Tendering process and all known prejudiced persons.
(2) If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC / PC Act , or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID’s Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles during its participation in the tender process and during the contract execution:
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or during the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC / IPC Act.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/information in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
g) The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may, after following due procedures, ban /blacklist the Bidder/Contractor in line with POWERGRID’s policy for “Black-Listing of Firms / Banning of Business”. The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for forfeiture of the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country, that may impinge on the Anti-corruption principle.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID’s policies.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or its subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of the IEMs have been indicated in the Bidding Documents.
(2) The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings, at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He / She reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his / her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEMs information as sought by him / her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on ’Non-Disclosure of Confidential Information’ and of ‘Absence of Conflict of Interest’. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and recuse himself/herself from that case
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he / she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC / IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) While representing any matter in relation to the Integrity pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter.
(10) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing. Side agreements have not been made.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
(6) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(7) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Integrity Pact Page 8 of 8
Specification No.: 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-15 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Initial Advance
Supply Portion:
Services Portion:
Interest Bearing Engineering Advance
Supply Portion:
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
10. PF Regional Office covered (with Address)
11. Name of Contact Person
12. Contact Details
13. Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
14. 9 digit MICR code printed at bottom in middle, next to cheque no.
15. IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
Date : ……………. Printed Name : …………………….
Place : ………………. Designation : ……………………
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-16 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Additional Information)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder)
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
(iii) Details of Provident Fund Code Number of the Bidder
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-16
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Additional Information)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : #REF! Power Grid Corporation of India Ltd.,
Address : #REF! "Saudamini", Plot No. 2, Sector 29
#REF! Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 OTHER INFORMATION
3.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
3.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-16
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Additional Information)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference): Reference ITB clause 9.3(p)(ii)
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3 (p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Name of Banker `
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid.
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 OTHER INFORMATION
3.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
3.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-17 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-17 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. "Saudamini", Plot No. 2, Sector 29
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-17 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-18 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Safety Pact is annexed herewith this Volume.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-19 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : Printed Name :
Place : Designation :
Specification No 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contract Services 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
"Saudamini", Plot No. 2, Sector 29 11 eleven 11 th 11 November
Gurgaon (Haryana) - 122001 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
(a) Attachment 1(TL-01) : Bid Security or Online Payment Acknowledgement towards Bid Security (if required) or documentary evidence in support of exemption of Bid Security (submission of Hard Copy in “Original‟ for Bid Security and in “Copy‟ for documentary proof in support of exemption and Online Payment Acknowledgement towards Bid Security ) Bank Guarantee INR 250 Banks certified Cheque twenty 20 twenty 20 th
Online Payment Acknowledgement towards Bid Security for a sum of INR Enter details here.
OR documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 13.1 of ITB, Section-II Online Payment INR
(b) Attachment 2(TL-01) : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee (250) 21 st
(c) Attachment 3(TL-01) : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). Sole Bidder Online Payment 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). 0 #REF! Applicable 23 th
Further the required deed of Joint Undertaking signed by us and Tower Manufacturer has also been furnished as per your format. Not Applicable 24 th
(d) Attachment 4(TL-01) : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5(TL-01) : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A(TL-01) : (Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises): The details of the items, components, raw material, services which is proposed to bought/availed from Micro and Small Enterprises for the purpose of completion of works.
(g) Attachment 6(TL-01) : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7(TL-01) : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 28 th
(i) Attachment 8(TL-01) : Manufacturer’s Authorisation Forms. 29 th
(j) Attachment 9(TL-01) : Work Completion Schedule. 30 th
(k) Attachment 10(TL-01) : Guarantee Declaration. 31 st
(l) Attachment 11(TL-01) : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12(TL-01) : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13(TL-01) : Declaration regarding Social Accountability.
(o) Attachment 14(TL-01) : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15(TL-01) : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16(TL-01) : Additional Information.
(r) Attachment 17(TL-01) : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18(TL-01) : Safety Pact
(t) Attachment 19(TL-01) : Declaration.
(u) Attachment 20(TL-01) : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 21(TL-01) : Authorization certificate issued by Domestic Manufacturer for selling Domestically Manufactured Iron & Steel Products
(w) Attachment 22(TL-01) : Affidavit of Self certification regarding Domestic Value Addition in Iron & Steel Products
(x) Attachment 23(TL-01) : Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
(y) Attachment 24(TL-01) : Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
(z) Attachment 25((TL-01) : Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA.
(aa) Attachment 26(TL-01) : Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
(bb) Attachment 27(TL-01) : Certification by the Bidder as per DoE Order in line with ITB Clause 2.1
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
3.0 A * (applicable for MSE only) We are a Micro and Small Enterprise (MSE) registered with................................, a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012, Notification dated 01/06/2020 and 26/06/2020 including subsequent amendments read in conjunction with related notifications issued from time to time for such enterprises. Delete if not applicable
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, insurance, unloading, storage, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 5.1 Contractor’s Responsibilities
(d) GCC 8 Terms of Payment
(e) GCC 9.3 Performance Security
(f) GCC 10 Taxes and Duties
(g) GCC 21.2 Completion Time Guarantee
(h) GCC 22 Defect Liability
(i) GCC 23 Functional Guarantee
(j) GCC 25 Patent Indemnity
(k) GCC 26 Limitation of Liability
(l) GCC 38 Settlement of Disputes
(m) GCC 39 Arbitration
(n) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of Six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:-
Name and address of agent Amount and Currency Purpose of Commission or gratuity
(If none, state “none”)
13.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
#REF! Printed Name :
#REF! Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2(TL-01) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2(TL-01) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Package Name Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Package Code TL01 Bought-out
Specification No. 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3, Sch-5, Sch-7 and Bid Form 2nd Envelope.
2 All the cells in Sch-4 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● Fill up applicable rate of Excise Duty. The amount of Excise Duty on the items mentioned as Direct in the mode of transaction in Schedule-1 shall be calculated automatically at the rate mentioned by the bidder here.
● Segregate and fill up the amount on which Sales Tax shall be applicable out of Ex-works supply items mentioned as direct in the mode of transaction in Schedule-1. Applicable Excise Duty on this amount will be calculated automatically at the rate mentioned by the bidder. Further, fill up the rate of applicable Sales Tax. Amount of Sales Tax shall be automatically calculated on the amount mentioned by the bidder as subjected to Sales Tax plus applicable Excise Duty at the rate mentioned by the Bidder.
● Difference of total amount quoted by the bidder as Direct Transaction and the amount mentioned by him subjected to Sales Tax shall be considered as the amount on which VAT shall become applicable and the same shall be calculated & displayed automatically. Applicable Excise Duty on this amount at the rate mentioned by the bidder shall also be calculated & displayed automatically. Fill up the rate of applicable VAT. The amount of VAT shall be calculated automatically on the amount considered to be subjected to VAT plus applicable Excise Duty at the rate mentioned by the bidder here.
● Amount as per details filled up by the bidder in the work sheets Entry Tax, Octroi and other Taxes & Duties shall be displayed in this work sheet Sch-5 but will not be added to the grand total and shall be considered as applicable.
● Click at the links to go to the work sheets Entry Tax, Octroi and other Taxes & Duties one by one.
● Fill the description, amount and rate of applicable Entry Tax. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Fill the description, amount and rate of applicable Octroi. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
Other Taxes & Duties :
● Fill the description, amount and rate of applicable Other Taxes & Duties. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid form 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Sole Bidder 1
JV (Joint Venture) Other Partner
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 1 0
Name of Sole Bidder
Address of Sole Bidder
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule-1
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : Contract Services 0
Name : Power Grid Corporation of India Ltd., #REF!
Address : "Saudamini", Plot No.-2 #REF!
Gurgaon (Haryana) - 122001
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted.
(All Prices are in Indian Rupees)
SI. No. PR No PR Line Item No Activity Description Material Code HSN Code Whether HSN in column ‘6’ is confirmed. If not indicate applicable the HSN code # Rate of GST applicable ( in %) Whether rate of GST in column ‘8’ is confirmed. If not indicate applicable rate of GST # Item Description Unit Qty. Unit Ex-Works Price (excluding GST) Total Ex-Works Price (excluding GST)
A 220KV RANGIT IV-NEW MELLI TL
1 7000018805 10 FABRICATION AND SUPPLY 1000013391 73082011 18 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-HTSteel for Normal Towers MT 226 INCLUDED 0 0 0.00 0.00 0.00 0.00
2 7000018805 20 FABRICATION AND SUPPLY 1000015274 73082011 18 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-MSSteel for Normal Towers MT 89 INCLUDED 0 0 0 0.00 0.00 0.00
3 7000018805 30 FABRICATION AND SUPPLY 1000013393 73082011 18 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-HT Steel for Normal Towers MT 13 INCLUDED 0 0 0 0.00 0.00 0.00
4 7000018805 40 FABRICATION AND SUPPLY 1000015276 73082011 18 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-MS Steel for Normal Towers MT 1.5 INCLUDED 0 0 0 0.00 0.00 0.00
5 7000018805 50 FABRICATION AND SUPPLY 1000013472 73181500 18 Supply of Hexagonal Bolts & Nuts for towers including Step Bolts, SpringWashers etc. MT 17 INCLUDED 0 0 0 0.00 0.00 0.00
6 7000018805 60 FABRICATION AND SUPPLY 1000007847 73181500 18 Supply of Bolts & Nuts for Stubs including Spring Washers etc. MT 0.5 INCLUDED 0 0 0 0.00 0.00 0.00
7 7000018805 70 EARTHING OF TOWERS 1000010003 73082011 18 Supply of Counterpoise type (120 m length) EA 7 INCLUDED 0 0 0 0.00 0.00 0.00
8 7000018805 80 EARTHING OF TOWERS 1000045872 73082011 18 COUNTERPOISE TYPE CHEMICAL EARTHING EA 5 INCLUDED 0 0 0 0.00 0.00 0.00
9 7000018805 90 EARTHING OF TOWERS 1000019717 73082011 18 Supply of Shieldwire Earthing includingPG clamps, downlead clamps butexcluding Earthwire bits forCounterpoise type earthing EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
10 7000018805 100 EARTHING OF TOWERS 1000010005 73082011 18 Counterpoise type (280 m length) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
11 7000018805 150 TOWER ACCESSORIES 1000010538 73082011 18 Danger Plate for 220kV EA 14 INCLUDED 0 0 0 0.00 0.00 0.00
12 7000018805 140 TOWER ACCESSORIES 1000015970 73082011 18 Number Plate for 220kV EA 14 INCLUDED 0 0 0 0.00 0.00 0.00
13 7000018805 110 TOWER ACCESSORIES 1000017508 73082011 18 Phase Plate (Set of three) SET 28 INCLUDED 0 0 0 0.00 0.00 0.00
14 7000018805 120 TOWER ACCESSORIES 1000009119 73082011 18 Circuit Plate (Set of two) SET 14 INCLUDED 0 0 0 0.00 0.00 0.00
15 7000018805 130 TOWER ACCESSORIES 1000006779 73082011 18 Supply of Anti-Climbing Devices ofBarbed Wire Type SET 14 INCLUDED 0 0 0 0.00 0.00 0.00
16 7000018805 160 CONDUCTOR 1000030860 76141000 18 ACSR MOOSE CONDUCTOR KM 47 INCLUDED 0 0 0 0.00 0.00 0.00
17 7000018805 170 INSULATOR 1000009322 85469090 18 Composite long rod Insulators for 220kV Transmission Line-120 KN (Length-2175 mm, Creepage-7595 mm) EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
18 7000018805 180 INSULATOR 1000048899 85469090 18 COMPOSITE LONGROD INSULATOR - 220KV - 160KN (L2550) EA 360 INCLUDED 0 0 0 0.00 0.00 0.00
19 7000018805 190 HARDWARE FITTINGS 1000032564 73082011 18 HARDWARE FITTINGS FOR 220KV AC WITH TWIN ACSR MOOSE CONDUCTOR-DOUBLETENSION STRING SET 180 INCLUDED 0 0 0 0.00 0.00 0.00
20 7000018805 200 HARDWARE FITTINGS 1000032565 73082011 18 HARDWARE FITTINGS FOR 220KV AC WITH ACSR MOOSE CONDUCTOR-SINGLE ISUSPENSION PILOT SET 6 INCLUDED 0 0 0 0.00 0.00 0.00
21 7000018805 210 CONDUCTOR ACCESSORIES 1000015503 76169990 18 Mid Span Compression Joint for Conductor-ACSR Moose EA 23 INCLUDED 0 0 0 0.00 0.00 0.00
22 7000018805 220 CONDUCTOR ACCESSORIES 1000018443 76169990 18 Repair Sleeve for Conductor-ACSR Moose EA 7 INCLUDED 0 0 0 0.00 0.00 0.00
23 7000018805 230 CONDUCTOR ACCESSORIES 1000022431 73082011 18 Vibration Damper for Conductor-ACSR Moose EA 720 INCLUDED 0 0 0 0.00 0.00 0.00
24 7000018805 240 CONDUCTOR ACCESSORIES 1000007935 76169990 18 Bundle Spacer for Conductor-Twin ACSR Moose EA 630 INCLUDED 0 0 0 0.00 0.00 0.00
25 7000018805 250 CONDUCTOR ACCESSORIES 1000018569 76169990 18 Rigid Spacer-450mm suconductor spacing Twin Moose as per specificationand drawing EA 270 INCLUDED 0 0 0 0.00 0.00 0.00
26 7000018805 330 SPARE - INSULATOR 1000048899 85469090 18 COMPOSITE LONGROD INSULATOR - 220KV - 160KN (L2550) EA 36 INCLUDED 0 0 0 0.00 0.00 0.00
27 7000018805 340 SPARE - HARDWARE FITTINGS 1000032564 73082011 18 HARDWARE FITTINGS FOR 220KV AC WITH TWIN ACSR MOOSE CONDUCTOR-DOUBLETENSION STRING SET 4 INCLUDED 0 0 0 0.00 0.00 0.00
28 7000018805 350 SPARE - CONDUCTOR ACCESSORIES 1000015503 76169990 18 Mid Span Compression Joint for Conductor-ACSR Moose EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
29 7000018805 360 SPARE - CONDUCTOR ACCESSORIES 1000018443 76169990 18 Repair Sleeve for Conductor-ACSR Moose EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
30 7000018805 370 SPARE - CONDUCTOR ACCESSORIES 1000022431 73082011 18 Vibration Damper for Conductor-ACSR Moose EA 15 INCLUDED 0 0 0 0.00 0.00 0.00
31 7000018805 380 SPARE - CONDUCTOR ACCESSORIES 1000007935 76169990 18 Bundle Spacer for Conductor-Twin ACSR Moose EA 13 INCLUDED 0 0 0 0.00 0.00 0.00
32 7000018805 390 SPARE - CONDUCTOR ACCESSORIES 1000018569 76169990 18 Rigid Spacer-450mm suconductor spacing Twin Moose as per specificationand drawing EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
33 7000018805 400 SPARE - FABRICATION AND SUPPLY 1000013391 73082011 18 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-HTSteel for Normal Towers MT 2.26 INCLUDED 0 0 0 0.00 0.00 0.00
34 7000018805 410 SPARE - FABRICATION AND SUPPLY 1000015274 73082011 18 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-MSSteel for Normal Towers MT 0.9 INCLUDED 0 0 0 0.00 0.00 0.00
35 7000018805 420 SPARE - FABRICATION AND SUPPLY 1000013393 73082011 18 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-HT Steel for Normal Towers MT 0.13 INCLUDED 0 0 0 0.00 0.00 0.00
36 7000018805 430 SPARE - FABRICATION AND SUPPLY 1000015276 73082011 18 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-MS Steel for Normal Towers MT 0.015 INCLUDED 0 0 0 0.00 0.00 0.00
37 7000018805 440 SPARE - FABRICATION AND SUPPLY 1000013472 73181500 18 Supply of Hexagonal Bolts & Nuts for towers including Step Bolts, SpringWashers etc. MT 0.17 INCLUDED 0 0 0 0.00 0.00 0.00
38 7000018805 450 SPARE - FABRICATION AND SUPPLY 1000007847 73181500 18 Supply of Bolts & Nuts for Stubs including Spring Washers etc. MT 0.005 INCLUDED 0 0 0 0.00 0.00 0.00
39 7000018805 480 OPGW & Accessories 1000030940 85447090 18 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE KM 4.2 INCLUDED 0 0 0 0.00 0.00 0.00
40 7000018805 490 OPGW & Accessories 1000033144 82057000 18 TENSION ASSEMBLY - DEAD END FOR 24 FIBER OPGW SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
41 7000018805 500 OPGW & Accessories 1000031039 82057000 18 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
42 7000018805 510 OPGW & Accessories 1000033146 82057000 18 TENSION ASSEMBLY - DOUBLE TENSION PASS THROUGH ASSEMBLY FOR 24 FIBEROPGW SET 11 INCLUDED 0 0 0.00 0.00 0.00 0.00
43 7000018805 520 OPGW & Accessories 1000022417 82057000 18 Vibration Damper for 24 fibre OPGW EA 52 INCLUDED 0 0 0 0.00 0.00 0.00
44 7000018805 530 OPGW & Accessories 1000010817 82057000 18 Down Lead clamp Assembly for 24 fibre OPGW EA 80 INCLUDED 0 0 0 0.00 0.00 0.00
45 7000018805 540 OPGW & Accessories 1000014198 85353090 18 Joint Box for 24 fibre OPGW EA 3 INCLUDED 0 0 0 0.00 0.00 0.00
46 7000018805 550 OPGW & Accessories 1000023471 85372000 18 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
47 7000018805 560 OPGW & Accessories 1000037545 85447090 18 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
48 7000018805 570 OPGW & Accessories 1000006437 85446090 18 APPROACH CABLE INSTALLATION HARDWARE SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
49 7000018805 580 Spares : OPGW & accessories 1000030940 85447090 18 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
50 7000018805 590 Spares : OPGW & accessories 1000033144 82057000 18 TENSION ASSEMBLY - DEAD END FOR 24 FIBER OPGW SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
51 7000018805 600 Spares : OPGW & accessories 1000031039 82057000 18 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
52 7000018805 610 Spares : OPGW & accessories 1000033146 82057000 18 TENSION ASSEMBLY - DOUBLE TENSION PASS THROUGH ASSEMBLY FOR 24 FIBEROPGW SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
53 7000018805 620 Spares : OPGW & accessories 1000022417 82057000 18 Vibration Damper for 24 fibre OPGW EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
54 7000018805 630 Spares : OPGW & accessories 1000010817 82057000 18 Down Lead clamp Assembly for 24 fibre OPGW EA 3 INCLUDED 0 0 0 0.00 0.00 0.00
55 7000018805 640 Spares : OPGW & accessories 1000014198 85353090 18 Joint Box for 24 fibre OPGW EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
56 7000018805 650 Spares : OPGW & accessories 1000037545 85447090 18 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 0.5 INCLUDED 0 0 0 0.00 0.00 0.00
57 7000018805 660 Spares : OPGW & accessories 1000006437 85446090 18 APPROACH CABLE INSTALLATION HARDWARE SET 0.5 INCLUDED 0 0 0 0.00 0.00 0.00
B 220 KV New Melli (PG) GIS S/s extn
1 7000018777 10 220kV, 40kA GIS Equipment 1000001571 85359030 18 245kV,1600A, 40kA,Single phase, SF6 Gas Insulated Bus Duct(GIB) outside GIS Hall alongwith associated support structure M 350 INCLUDED 0 0 0 0.00 0.00 0.00
2 7000018777 20 220kV, 40kA GIS Equipment 1000032764 85389000 18 245KV, 1600A, 40KA SINGLE PHASE SF6 TO AIR BUSHING SET 6 INCLUDED 0 0 0 0.00 0.00 0.00
3 7000018777 30 220kV, 40kA GIS Equipment 1000001679 85359030 18 245kV, 1600 A, 40 kA, SF6 GIS Linefeeder bay module as perSection-Project, Technicalspecification SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
4 7000018777 40 220kV, 40kA GIS Equipment 1000032783 85359030 18 245 KV, 3000 A, 40 KA, SF6 GIS BUS BAR MODULE EXTENSION AS PERSECTION-PROJECT, TECHNICAL SPECIFICATION SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
5 7000018777 50 245kV, 40kA AIS EQUIPMENT 1000001772 85359090 18 245 kV, 4400pf Capacitive Voltage Transformer (1- Phase) EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
6 7000018777 60 245kV, 40kA AIS EQUIPMENT 1000020417 85354010 18 216kV Surge Arrester (1-phase) EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
7 7000018777 70 245kV, 40kA AIS EQUIPMENT 1000001695 85462040 18 245 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
8 7000018777 80 245kV, 40kA AIS EQUIPMENT 1000001694 85462040 18 245 kV ,1 phase Bus Post Insulators for Line Traps EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
9 7000018777 90 Erection Hardware for 220 kV GIS 1000011246 72169990 18 Erection Hardware for 220kV DM-type layout for GIS terminationarrangement-Line bay as per technical specification SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
10 7000018777 100 Earthmat 1000032055 72159090 18 40 MM MS ROD FOR MAIN EARTHMAT KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
11 7000018777 110 CRP for 220kV Bays with SAS at New Melli 1000001167 85371000 18 Augmentation of existing 220kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
12 7000018777 120 CRP for 220kV Bays with SAS at New Melli 1000001330 85371000 18 220kV Line Protection Panel (with Automation) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
13 7000018777 130 CRP for 220kV Bays with SAS at New Melli 1000001170 85371000 18 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
14 7000018777 140 SAS-AUG 1000001333 85371000 18 Augmentation of Substation automation System for 220kV bay as perTechnical Specification EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
15 7000018777 150 PLCC Equipment at New Melli 1000001567 85176210 18 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
16 7000018777 160 PLCC Equipment at New Melli 1000010014 85176210 18 Coupling device for PLCC SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
17 7000018777 170 PLCC Equipment at New Melli 1000000046 85176210 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
18 7000018777 180 PLCC Equipment at New Melli 1000017887 85176210 18 Analog Protection Coupler for PLCC EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
19 7000018777 190 PLCC Equipment at New Melli 1000010638 85176210 18 Digital Protection Coupler EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
20 7000018777 200 PLCC Equipment at New Melli 1000001104 85176210 18 2wire telephone equipment EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
21 7000018777 210 PLCC Equipment at New Melli 1000025769 85176210 18 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
22 7000018777 220 PLCC Equipment at New Melli 1000036908 85446020 18 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
23 7000018777 230 PLCC Equipment at Rangit(NHPC) 1000036908 85446020 18 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
24 7000018777 240 PLCC Equipment at Rangit(NHPC) 1000025769 85176210 18 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
25 7000018777 250 PLCC Equipment at Rangit(NHPC) 1000001104 85176210 18 2wire telephone equipment EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
26 7000018777 260 PLCC Equipment at Rangit(NHPC) 1000010638 85176210 18 Digital Protection Coupler EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
27 7000018777 270 PLCC Equipment at Rangit(NHPC) 1000017887 85176210 18 Analog Protection Coupler for PLCC EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
28 7000018777 280 PLCC Equipment at Rangit(NHPC) 1000000046 85176210 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
29 7000018777 290 PLCC Equipment at Rangit(NHPC) 1000010014 85176210 18 Coupling device for PLCC SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
30 7000018777 300 PLCC Equipment at Rangit(NHPC) 1000001567 85176210 18 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
34 7000018777 340 POWER & CONTROL CABLE 1000031908 85446020 18 1.1KV GRADE 19CX2.5 SQMM CONTROL CABLE KM 0.8 INCLUDED 0 0 0 0.00 0.00 0.00
35 7000018777 350 POWER & CONTROL CABLE 1000031887 85446020 18 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 0.5 INCLUDED 0 0 0 0.00 0.00 0.00
36 7000018777 370 POWER & CONTROL CABLE 1000031964 85446020 18 1.1KV GRADE 3CX2.5 SQMM CONTROL CABLE KM 0.4 INCLUDED 0 0 0 0.00 0.00 0.00
37 7000018777 380 POWER & CONTROL CABLE 1000031985 85446020 18 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 0.8 INCLUDED 0 0 0 0.00 0.00 0.00
38 7000018777 360 POWER & CONTROL CABLE 1000031987 85446020 18 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE KM 1.5 INCLUDED 0 0 0 0.00 0.00 0.00
39 7000018777 390 POWER & CONTROL CABLE 1000031927 85446020 18 1.1KV GRADE 27CX2.5 SQMM CONTROL CABLE KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
40 7000018777 400 POWER & CONTROL CABLE 1000031976 85446020 18 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 0.5 INCLUDED 0 0 0 0.00 0.00 0.00
41 7000018777 410 POWER & CONTROL CABLE 1000031953 85446020 18 1.1KV GRADE 3.5CX35 SQMM (PVC) POWER CABLE KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
42 7000018777 420 ILLUMINATION SYSTEM 1000014547 85371000 18 Lighting Panel type ACP-2 as per technical specification EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
43 7000018777 430 ILLUMINATION SYSTEM 1000017485 94059900 18 Lighting panel SLP for Street Lighting EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
44 7000018777 440 ILLUMINATION SYSTEM 1000004952 94059900 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
45 7000018777 450 ILLUMINATION SYSTEM 1000038387 94051090 18 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
46 7000018777 460 ILLUMINATION SYSTEM 1000038325 94059900 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
47 7000018777 470 220 kV Towers 1000015954 73082011 18 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 39 INCLUDED 0 0 0 0.00 0.00 0.00
48 7000018777 480 220 kV Towers 1000011713 73082011 18 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 2.4 INCLUDED 0 0 0 0.00 0.00 0.00
49 7000018777 490 220 kV Towers 1000012373 73082011 18 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 6.5 INCLUDED 0 0 0 0.00 0.00 0.00
50 7000018777 500 220kV Equipment support structures 1000017562 73045930 18 Standard Pipe Structure for 220kV BPI (excluding wave trap) EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
51 7000018777 510 220kV Equipment support structures 1000020188 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CVT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
52 7000018777 520 220kV Equipment support structures 1000020190 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
53 7000018777 530 220kV Equipment support structures 1000012366 73082011 18 Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 108 INCLUDED 0 0 0 0.00 0.00 0.00
54 7000018777 540 220kV Equipment support structures 1000020191 73045930 18 Fabrication, galvanising and supply of Std Pipe Structure - 220 kV WTincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 12 INCLUDED 0 0 0 0.00 0.00 0.00
55 7000018777 550 SPARES FOR 245kV CVT 1000025934 85359090 18 Spare-245kV CVT SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
56 7000018777 560 SPARES FOR 216kV Surge Arrester 1000025930 85354010 18 Spare-216kV Surge Arrester SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
57 7000018777 570 SPARES FOR 220V BPI 1000027480 85462040 18 Spares-Bus Post Insulator for 765 kV and 400kV system LOT 1 INCLUDED 0 0 0 0.00 0.00 0.00
58 7000018777 580 SPARES FOR CRP 1000019912 85371000 18 Relay & protection Panels (with automation) LS 1 INCLUDED 0 0 0 0.00 0.00 0.00
59 7000018777 590 SPARES FOR SAS 1000019927 85389000 18 Spares-Substation Automation System LS 1 INCLUDED 0 0 0 0.00 0.00 0.00
60 7000018777 600 SPARES FOR PLCC 1000025950 85176210 18 Spare-PLCC SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
61 7000018777 750 Spares for 220kV GIS 1000058295 85359030 18 220KV GIS- CABLE CONNECTION ENCLOSURE WITH MAIN CIRCUIT SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
62 7000018777 760 Spares for 220kV GIS 1000058300 85359030 18 220KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
63 7000018777 770 Spares for 220kV GIS 1000049816 85359030 18 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-220KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00 0.00
64 7000018777 780 Spares for 220kV GIS 1000049752 85359030 18 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-220KV GIS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
65 7000018777 790 Spares for 220kV GIS 1000049761 85359030 18 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-220KV GIS SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
66 7000018777 800 Spares for 220kV GIS 1000058298 85359030 18 220KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
67 7000018777 810 Spares for 220kV GIS 1000049749 85359030 18 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-220KV GIS SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
68 7000018777 820 Spares for 220kV GIS 1000058299 85359030 18 220KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 INCLUDED 0 0 0 0.00 0.00 0.00
69 7000018777 830 Spares for 220kV GIS 1000049782 85359030 18 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES (AS APPLICABLE) IN CLOSE OR OPENPOSITION IN CASE OF REMOVAL OF THE DRIVING MECHANISM-220KV GIS SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
70 7000018777 840 Spares for 220kV GIS 1000049504 85359030 18 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 245KV GIS EA 3 INCLUDED 0 0 0 0.00 0.00 0.00
71 7000018777 850 Spares for 220kV GIS 1000058302 85359030 18 220KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED 0 0 0 0.00 0.00 0.00
72 7000018777 860 Spares for 220kV GIS 1000058297 85359030 18 220KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED 0 0 0 0.00 0.00 0.00
73 7000018777 870 Spares for 220kV GIS 1000058301 85359030 18 220KV GIS- 1600A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
74 7000018777 880 Spares for 220kV GIS 1000049497 85359030 18 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-220kV GIS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
75 7000018777 890 Spares for 220kV GIS 1000058284 85359030 18 220KV GIS-ONE POLE OF 1600A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
76 7000018777 900 Spares for 220kV GIS 1000021871 85389000 18 Trip coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED 0 0 0 0.00 0.00 0.00
77 7000018777 910 Spares for 220kV GIS 1000009185 85389000 18 Closing coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED 0 0 0 0.00 0.00 0.00
78 7000018777 920 Spares for 220kV GIS 1000058292 85359030 18 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 220KV GIS CIRCUIT BREAKER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
79 7000018777 930 Spares for 220kV GIS 1000007066 85389000 18 Auxiliary switch assembly of each type for 245kV GIS Circuit Breaker SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
80 7000018777 940 Spares for 220kV GIS 1000058291 85359030 18 220KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
81 7000018777 950 Spares for 220kV GIS 1000058288 85359030 18 220KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
82 7000018777 960 Spares for 220kV GIS 1000049758 85359030 18 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
83 7000018777 970 Spares for 220kV GIS 1000058272 85359030 18 220KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
84 7000018777 980 Spares for 220kV GIS 1000058290 85359030 18 220KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
85 7000018777 990 Spares for 220kV GIS 1000049834 85359030 18 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
86 7000018777 1000 Spares for 220kV GIS 1000049794 85359030 18 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
87 7000018777 1010 Spares for 220kV GIS 1000049807 85359030 18 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
88 7000018777 1020 Spares for 220kV GIS 1000049804 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
89 7000018777 1030 Spares for 220kV GIS 1000058289 85359030 18 220KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
90 7000018777 1040 Spares for 220kV GIS 1000049798 85359030 18 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
91 7000018777 1050 Spares for 220kV GIS 1000058293 85359030 18 220KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
92 7000018777 1060 Spares for 220kV GIS 1000058287 85359030 18 220KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
93 7000018777 1070 Spares for 220kV GIS 1000049797 85359030 18 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC-SPRING OPERATEDMECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREAKER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
94 7000018777 1080 Spares for 220kV GIS 1000049801 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
95 7000018777 1090 Spares for 220kV GIS 1000058371 85359030 18 220kV GIS- Three phase of 1600Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
96 7000018777 1100 Spares for 220kV GIS 1000058282 85359030 18 220KV GIS- THREE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
97 7000018777 1110 Spares for 220kV GIS 1000058278 85359030 18 220KV GIS - THREE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
98 7000018777 1120 Spares for 220kV GIS 1000058273 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS DISCONNECTORSWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
99 7000018777 1130 Spares for 220kV GIS 1000058280 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS MAINTENANCE EARTHSWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
100 7000018777 1140 Spares for 220kV GIS 1000058276 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS FAST EARTHINGSWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
101 7000018777 1150 Spares for 220kV GIS 1000049773 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-220KV GIS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
102 7000018777 1160 Spares for 220kV GIS 1000049775 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-220KV GIS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
103 7000018777 1170 Spares for 220kV GIS 1000049774 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-220KV GIS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
104 7000018777 1180 Spares for 220kV GIS 1000058274 85359030 18 DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
105 7000018777 1190 Spares for 220kV GIS 1000058281 85359030 18 DRIVE MECHANISM FOR 220KV GIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
106 7000018777 1200 Spares for 220kV GIS 1000058277 85359030 18 DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
107 7000018777 1210 Spares for 220kV GIS 1000058275 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
108 7000018777 1220 Spares for 220kV GIS 1000058283 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 220KVGIS MAINTENANCE EARTH SWITCH EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
109 7000018777 1230 Spares for 220kV GIS 1000058279 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
110 7000018777 1240 Spares for 220kV GIS 1000058294 85359030 18 220KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (4 CORES) WITHASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALL RESPECT EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
111 7000018777 1250 Spares for 220kV GIS 1000058296 85359030 18 220KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
112 7000018777 1260 Spares for 220kV GIS 1000058303 85359030 18 220KV GIS- SINGLE PHASE GAS INSULATED SURGE ARRESTER WITH ASSOCIATEDENCLOSURE AND INSULATOR COMPLETE IN ALL RESPECT EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
113 7000018777 1270 Spares for 220kV GIS 1000058304 85359030 18 220KV GIS- SURGE COUNTER/ MONITOR EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
114 7000018777 1280 Telecom Eqpt for New Melli 1000028251 85176260 18 Base Equipment STM-4 MADM upto 5 MSP SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
115 7000018777 1290 Telecom Eqpt for New Melli 1000023721 85176260 18 SFP S4.1 EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
116 7000018777 1300 Telecom Eqpt for New Melli 1000023719 85176260 18 SFP L4.1 EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
117 7000018777 1310 Telecom Eqpt for New Melli 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
118 7000018777 1320 Telecom Eqpt for New Melli 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
119 7000018777 1330 Telecom Eqpt for New Melli 1000026228 85176290 18 Equipment Cabinets For SDH EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
120 7000018777 1340 Telecom Eqpt for New Melli 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
121 7000018777 1360 Telecom Spare at New Melli 1000023721 85176260 18 SFP S4.1 EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
122 7000018777 1370 Telecom Spare at New Melli 1000023719 85176260 18 SFP L4.1 EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
123 7000018777 1380 Telecom Equipment at Rangit(NHPC) 1000028251 85176260 18 Base Equipment STM-4 MADM upto 5 MSP SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
124 7000018777 1390 Telecom Equipment at Rangit(NHPC) 1000023721 85176260 18 SFP S4.1 EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
125 7000018777 1400 Telecom Equipment at Rangit(NHPC) 1000023719 85176260 18 SFP L4.1 EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
126 7000018777 1410 Telecom Equipment at Rangit(NHPC) 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
127 7000018777 1420 Telecom Equipment at Rangit(NHPC) 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
128 7000018777 1430 Telecom Equipment at Rangit(NHPC) 1000026228 85176290 18 Equipment Cabinets For SDH EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
129 7000018777 1440 Telecom Equipment at Rangit(NHPC) 1000028495 84715000 18 NMS- CRAFT TERMINAL-HARDWARE EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
130 7000018777 1450 Telecom Equipment at Rangit(NHPC) 1000028265 85238020 18 Software for Craft Terminal EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
131 7000018777 1460 Telecom Equipment at Rangit(NHPC) 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
132 7000018777 1480 Telecom Spares at Rangit(NHPC) 1000031371 85176260 18 SDH EQUIPMENT (STM-4 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
133 7000018777 1490 Telecom Spares at Rangit(NHPC) 1000023721 85176260 18 SFP S4.1 EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
134 7000018777 1500 Telecom Spares at Rangit(NHPC) 1000023719 85176260 18 SFP L4.1 EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
135 7000018777 1510 Telecom Spares at Rangit(NHPC) 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
136 7000018777 1520 Telecom Spares at Rangit(NHPC) 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
137 7000018777 1530 Telecom Spares at Rangit(NHPC) 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
138 7000018777 1540 Telecom Spares at Rangit(NHPC) 1000031398 85171890 18 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
Total Ex-Works Price 0.00 0.00 0.00 0.00 0.00
Total Type Test charges as per Schedule-7 0.00
Total Ex-Works Price including Type Test charges 0.00
# In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date Printed Name
Place Designation
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 2
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Local Transportation, In-transit Insurance, Loading and Unloading
(All Prices are in Indian Rupees)
SI. No. PR No PR Line Item No Activity Description Material Code Description Unit Quantity Unit Freight, In-transit Insurance, loading & Unloading Charges Total Freight, In-transit Insurance, loading & Unloading Charges
A 220KV RANGIT IV-NEW MELLI TL
1 7000018805 10 FABRICATION AND SUPPLY 1000013391 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-HTSteel for Normal Towers MT 226 INCLUDED
2 7000018805 20 FABRICATION AND SUPPLY 1000015274 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-MSSteel for Normal Towers MT 89 INCLUDED
3 7000018805 30 FABRICATION AND SUPPLY 1000013393 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-HT Steel for Normal Towers MT 13 INCLUDED
4 7000018805 40 FABRICATION AND SUPPLY 1000015276 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-MS Steel for Normal Towers MT 1.5 INCLUDED
5 7000018805 50 FABRICATION AND SUPPLY 1000013472 Supply of Hexagonal Bolts & Nuts for towers including Step Bolts, SpringWashers etc. MT 17 INCLUDED
6 7000018805 60 FABRICATION AND SUPPLY 1000007847 Supply of Bolts & Nuts for Stubs including Spring Washers etc. MT 0.5 INCLUDED
7 7000018805 70 EARTHING OF TOWERS 1000010003 Supply of Counterpoise type (120 m length) EA 7 INCLUDED
8 7000018805 80 EARTHING OF TOWERS 1000045872 COUNTERPOISE TYPE CHEMICAL EARTHING EA 5 INCLUDED
9 7000018805 90 EARTHING OF TOWERS 1000019717 Supply of Shieldwire Earthing includingPG clamps, downlead clamps butexcluding Earthwire bits forCounterpoise type earthing EA 1 INCLUDED
10 7000018805 100 EARTHING OF TOWERS 1000010005 Counterpoise type (280 m length) EA 2 INCLUDED
11 7000018805 150 TOWER ACCESSORIES 1000010538 Danger Plate for 220kV EA 14 INCLUDED
12 7000018805 140 TOWER ACCESSORIES 1000015970 Number Plate for 220kV EA 14 INCLUDED
13 7000018805 110 TOWER ACCESSORIES 1000017508 Phase Plate (Set of three) SET 28 INCLUDED
14 7000018805 120 TOWER ACCESSORIES 1000009119 Circuit Plate (Set of two) SET 14 INCLUDED
15 7000018805 130 TOWER ACCESSORIES 1000006779 Supply of Anti-Climbing Devices ofBarbed Wire Type SET 14 INCLUDED
16 7000018805 160 CONDUCTOR 1000030860 ACSR MOOSE CONDUCTOR KM 47 INCLUDED
17 7000018805 170 INSULATOR 1000009322 Composite long rod Insulators for 220kV Transmission Line-120 KN (Length-2175 mm, Creepage-7595 mm) EA 6 INCLUDED
18 7000018805 180 INSULATOR 1000048899 COMPOSITE LONGROD INSULATOR - 220KV - 160KN (L2550) EA 360 INCLUDED
19 7000018805 190 HARDWARE FITTINGS 1000032564 HARDWARE FITTINGS FOR 220KV AC WITH TWIN ACSR MOOSE CONDUCTOR-DOUBLETENSION STRING SET 180 INCLUDED
20 7000018805 200 HARDWARE FITTINGS 1000032565 HARDWARE FITTINGS FOR 220KV AC WITH ACSR MOOSE CONDUCTOR-SINGLE ISUSPENSION PILOT SET 6 INCLUDED
21 7000018805 210 CONDUCTOR ACCESSORIES 1000015503 Mid Span Compression Joint for Conductor-ACSR Moose EA 23 INCLUDED
22 7000018805 220 CONDUCTOR ACCESSORIES 1000018443 Repair Sleeve for Conductor-ACSR Moose EA 7 INCLUDED
23 7000018805 230 CONDUCTOR ACCESSORIES 1000022431 Vibration Damper for Conductor-ACSR Moose EA 720 INCLUDED
24 7000018805 240 CONDUCTOR ACCESSORIES 1000007935 Bundle Spacer for Conductor-Twin ACSR Moose EA 630 INCLUDED
25 7000018805 250 CONDUCTOR ACCESSORIES 1000018569 Rigid Spacer-450mm suconductor spacing Twin Moose as per specificationand drawing EA 270 INCLUDED
26 7000018805 330 SPARE - INSULATOR 1000048899 COMPOSITE LONGROD INSULATOR - 220KV - 160KN (L2550) EA 36 INCLUDED
27 7000018805 340 SPARE - HARDWARE FITTINGS 1000032564 HARDWARE FITTINGS FOR 220KV AC WITH TWIN ACSR MOOSE CONDUCTOR-DOUBLETENSION STRING SET 4 INCLUDED
28 7000018805 350 SPARE - CONDUCTOR ACCESSORIES 1000015503 Mid Span Compression Joint for Conductor-ACSR Moose EA 1 INCLUDED
29 7000018805 360 SPARE - CONDUCTOR ACCESSORIES 1000018443 Repair Sleeve for Conductor-ACSR Moose EA 1 INCLUDED
30 7000018805 370 SPARE - CONDUCTOR ACCESSORIES 1000022431 Vibration Damper for Conductor-ACSR Moose EA 15 INCLUDED
31 7000018805 380 SPARE - CONDUCTOR ACCESSORIES 1000007935 Bundle Spacer for Conductor-Twin ACSR Moose EA 13 INCLUDED
32 7000018805 390 SPARE - CONDUCTOR ACCESSORIES 1000018569 Rigid Spacer-450mm suconductor spacing Twin Moose as per specificationand drawing EA 6 INCLUDED
33 7000018805 400 SPARE - FABRICATION AND SUPPLY 1000013391 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-HTSteel for Normal Towers MT 2.26 INCLUDED
34 7000018805 410 SPARE - FABRICATION AND SUPPLY 1000015274 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-MSSteel for Normal Towers MT 0.9 INCLUDED
35 7000018805 420 SPARE - FABRICATION AND SUPPLY 1000013393 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-HT Steel for Normal Towers MT 0.13 INCLUDED
36 7000018805 430 SPARE - FABRICATION AND SUPPLY 1000015276 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-MS Steel for Normal Towers MT 0.015 INCLUDED
37 7000018805 440 SPARE - FABRICATION AND SUPPLY 1000013472 Supply of Hexagonal Bolts & Nuts for towers including Step Bolts, SpringWashers etc. MT 0.17 INCLUDED
38 7000018805 450 SPARE - FABRICATION AND SUPPLY 1000007847 Supply of Bolts & Nuts for Stubs including Spring Washers etc. MT 0.005 INCLUDED
39 7000018805 480 OPGW & Accessories 1000030940 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE KM 4.2 INCLUDED
40 7000018805 490 OPGW & Accessories 1000033144 TENSION ASSEMBLY - DEAD END FOR 24 FIBER OPGW SET 2 INCLUDED
41 7000018805 500 OPGW & Accessories 1000031039 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 1 INCLUDED
42 7000018805 510 OPGW & Accessories 1000033146 TENSION ASSEMBLY - DOUBLE TENSION PASS THROUGH ASSEMBLY FOR 24 FIBEROPGW SET 11 INCLUDED
43 7000018805 520 OPGW & Accessories 1000022417 Vibration Damper for 24 fibre OPGW EA 52 INCLUDED
44 7000018805 530 OPGW & Accessories 1000010817 Down Lead clamp Assembly for 24 fibre OPGW EA 80 INCLUDED
45 7000018805 540 OPGW & Accessories 1000014198 Joint Box for 24 fibre OPGW EA 3 INCLUDED
46 7000018805 550 OPGW & Accessories 1000023471 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 2 INCLUDED
47 7000018805 560 OPGW & Accessories 1000037545 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 1 INCLUDED
48 7000018805 570 OPGW & Accessories 1000006437 APPROACH CABLE INSTALLATION HARDWARE SET 1 INCLUDED
49 7000018805 580 Spares : OPGW & accessories 1000030940 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE KM 1 INCLUDED
50 7000018805 590 Spares : OPGW & accessories 1000033144 TENSION ASSEMBLY - DEAD END FOR 24 FIBER OPGW SET 1 INCLUDED
51 7000018805 600 Spares : OPGW & accessories 1000031039 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 1 INCLUDED
52 7000018805 610 Spares : OPGW & accessories 1000033146 TENSION ASSEMBLY - DOUBLE TENSION PASS THROUGH ASSEMBLY FOR 24 FIBEROPGW SET 1 INCLUDED
53 7000018805 620 Spares : OPGW & accessories 1000022417 Vibration Damper for 24 fibre OPGW EA 2 INCLUDED
54 7000018805 630 Spares : OPGW & accessories 1000010817 Down Lead clamp Assembly for 24 fibre OPGW EA 3 INCLUDED
55 7000018805 640 Spares : OPGW & accessories 1000014198 Joint Box for 24 fibre OPGW EA 1 INCLUDED
56 7000018805 650 Spares : OPGW & accessories 1000037545 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 0.5 INCLUDED
57 7000018805 660 Spares : OPGW & accessories 1000006437 APPROACH CABLE INSTALLATION HARDWARE SET 0.5 INCLUDED
B 220 KV New Melli (PG) GIS S/s extn
1 7000018777 10 220kV, 40kA GIS Equipment 1000001571 245kV,1600A, 40kA,Single phase, SF6 Gas Insulated Bus Duct(GIB) outside GIS Hall alongwith associated support structure M 350 INCLUDED
2 7000018777 20 220kV, 40kA GIS Equipment 1000032764 245KV, 1600A, 40KA SINGLE PHASE SF6 TO AIR BUSHING SET 6 INCLUDED
3 7000018777 30 220kV, 40kA GIS Equipment 1000001679 245kV, 1600 A, 40 kA, SF6 GIS Linefeeder bay module as perSection-Project, Technicalspecification SET 2 INCLUDED
4 7000018777 40 220kV, 40kA GIS Equipment 1000032783 245 KV, 3000 A, 40 KA, SF6 GIS BUS BAR MODULE EXTENSION AS PERSECTION-PROJECT, TECHNICAL SPECIFICATION SET 2 INCLUDED
5 7000018777 50 245kV, 40kA AIS EQUIPMENT 1000001772 245 kV, 4400pf Capacitive Voltage Transformer (1- Phase) EA 6 INCLUDED
6 7000018777 60 245kV, 40kA AIS EQUIPMENT 1000020417 216kV Surge Arrester (1-phase) EA 6 INCLUDED
7 7000018777 70 245kV, 40kA AIS EQUIPMENT 1000001695 245 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 6 INCLUDED
8 7000018777 80 245kV, 40kA AIS EQUIPMENT 1000001694 245 kV ,1 phase Bus Post Insulators for Line Traps EA 6 INCLUDED
9 7000018777 90 Erection Hardware for 220 kV GIS 1000011246 Erection Hardware for 220kV DM-type layout for GIS terminationarrangement-Line bay as per technical specification SET 2 INCLUDED
10 7000018777 100 Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 1 INCLUDED
11 7000018777 110 CRP for 220kV Bays with SAS at New Melli 1000001167 Augmentation of existing 220kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED
12 7000018777 120 CRP for 220kV Bays with SAS at New Melli 1000001330 220kV Line Protection Panel (with Automation) EA 2 INCLUDED
13 7000018777 130 CRP for 220kV Bays with SAS at New Melli 1000001170 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 2 INCLUDED
14 7000018777 140 SAS-AUG 1000001333 Augmentation of Substation automation System for 220kV bay as perTechnical Specification EA 2 INCLUDED
15 7000018777 150 PLCC Equipment at New Melli 1000001567 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED
16 7000018777 160 PLCC Equipment at New Melli 1000010014 Coupling device for PLCC SET 1 INCLUDED
17 7000018777 170 PLCC Equipment at New Melli 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED
18 7000018777 180 PLCC Equipment at New Melli 1000017887 Analog Protection Coupler for PLCC EA 2 INCLUDED
19 7000018777 190 PLCC Equipment at New Melli 1000010638 Digital Protection Coupler EA 2 INCLUDED
20 7000018777 200 PLCC Equipment at New Melli 1000001104 2wire telephone equipment EA 1 INCLUDED
21 7000018777 210 PLCC Equipment at New Melli 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED
22 7000018777 220 PLCC Equipment at New Melli 1000036908 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED
23 7000018777 230 PLCC Equipment at Rangit(NHPC) 1000036908 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED
24 7000018777 240 PLCC Equipment at Rangit(NHPC) 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED
25 7000018777 250 PLCC Equipment at Rangit(NHPC) 1000001104 2wire telephone equipment EA 1 INCLUDED
26 7000018777 260 PLCC Equipment at Rangit(NHPC) 1000010638 Digital Protection Coupler EA 2 INCLUDED
27 7000018777 270 PLCC Equipment at Rangit(NHPC) 1000017887 Analog Protection Coupler for PLCC EA 2 INCLUDED
28 7000018777 280 PLCC Equipment at Rangit(NHPC) 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED
29 7000018777 290 PLCC Equipment at Rangit(NHPC) 1000010014 Coupling device for PLCC SET 1 INCLUDED
30 7000018777 300 PLCC Equipment at Rangit(NHPC) 1000001567 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED
31 7000018777 310 LT SWITCHGEAR 1000004304 415V ACDB (Extn.) SET 1 INCLUDED
32 7000018777 320 LT SWITCHGEAR 1000001145 220V DCDB (Extn.) SET 1 INCLUDED
33 7000018777 330 LT SWITCHGEAR 1000004755 48V DCDB (Extn.) SET 1 INCLUDED
34 7000018777 340 POWER & CONTROL CABLE 1000031908 1.1KV GRADE 19CX2.5 SQMM CONTROL CABLE KM 0.8 INCLUDED
35 7000018777 350 POWER & CONTROL CABLE 1000031887 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 0.5 INCLUDED
36 7000018777 370 POWER & CONTROL CABLE 1000031964 1.1KV GRADE 3CX2.5 SQMM CONTROL CABLE KM 0.4 INCLUDED
37 7000018777 380 POWER & CONTROL CABLE 1000031985 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 0.8 INCLUDED
38 7000018777 360 POWER & CONTROL CABLE 1000031987 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE KM 1.5 INCLUDED
39 7000018777 390 POWER & CONTROL CABLE 1000031927 1.1KV GRADE 27CX2.5 SQMM CONTROL CABLE KM 1 INCLUDED
40 7000018777 400 POWER & CONTROL CABLE 1000031976 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 0.5 INCLUDED
41 7000018777 410 POWER & CONTROL CABLE 1000031953 1.1KV GRADE 3.5CX35 SQMM (PVC) POWER CABLE KM 1 INCLUDED
42 7000018777 420 ILLUMINATION SYSTEM 1000014547 Lighting Panel type ACP-2 as per technical specification EA 1 INCLUDED
43 7000018777 430 ILLUMINATION SYSTEM 1000017485 Lighting panel SLP for Street Lighting EA 1 INCLUDED
44 7000018777 440 ILLUMINATION SYSTEM 1000004952 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 1 INCLUDED
45 7000018777 450 ILLUMINATION SYSTEM 1000038387 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 2 INCLUDED
46 7000018777 460 ILLUMINATION SYSTEM 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 2 INCLUDED
47 7000018777 470 220 kV Towers 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 39 INCLUDED
48 7000018777 480 220 kV Towers 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 2.4 INCLUDED
49 7000018777 490 220 kV Towers 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 6.5 INCLUDED
50 7000018777 500 220kV Equipment support structures 1000017562 Standard Pipe Structure for 220kV BPI (excluding wave trap) EA 6 INCLUDED
51 7000018777 510 220kV Equipment support structures 1000020188 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CVT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 6 INCLUDED
52 7000018777 520 220kV Equipment support structures 1000020190 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 6 INCLUDED
53 7000018777 530 220kV Equipment support structures 1000012366 Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 108 INCLUDED
54 7000018777 540 220kV Equipment support structures 1000020191 Fabrication, galvanising and supply of Std Pipe Structure - 220 kV WTincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 12 INCLUDED
55 7000018777 550 SPARES FOR 245kV CVT 1000025934 Spare-245kV CVT SET 1 INCLUDED
56 7000018777 560 SPARES FOR 216kV Surge Arrester 1000025930 Spare-216kV Surge Arrester SET 1 INCLUDED
57 7000018777 570 SPARES FOR 220V BPI 1000027480 Spares-Bus Post Insulator for 765 kV and 400kV system LOT 1 INCLUDED
58 7000018777 580 SPARES FOR CRP 1000019912 Relay & protection Panels (with automation) LS 1 INCLUDED
59 7000018777 590 SPARES FOR SAS 1000019927 Spares-Substation Automation System LS 1 INCLUDED
60 7000018777 600 SPARES FOR PLCC 1000025950 Spare-PLCC SET 1 INCLUDED
61 7000018777 750 Spares for 220kV GIS 1000058295 220KV GIS- CABLE CONNECTION ENCLOSURE WITH MAIN CIRCUIT SET 1 INCLUDED
62 7000018777 760 Spares for 220kV GIS 1000058300 220KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 1 INCLUDED
63 7000018777 770 Spares for 220kV GIS 1000049816 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-220KV GIS SET 2 INCLUDED
64 7000018777 780 Spares for 220kV GIS 1000049752 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-220KV GIS SET 1 INCLUDED
65 7000018777 790 Spares for 220kV GIS 1000049761 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-220KV GIS SET 2 INCLUDED
66 7000018777 800 Spares for 220kV GIS 1000058298 220KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 INCLUDED
67 7000018777 810 Spares for 220kV GIS 1000049749 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-220KV GIS SET 2 INCLUDED
68 7000018777 820 Spares for 220kV GIS 1000058299 220KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 INCLUDED
69 7000018777 830 Spares for 220kV GIS 1000049782 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES (AS APPLICABLE) IN CLOSE OR OPENPOSITION IN CASE OF REMOVAL OF THE DRIVING MECHANISM-220KV GIS SET 2 INCLUDED
70 7000018777 840 Spares for 220kV GIS 1000049504 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 245KV GIS EA 3 INCLUDED
71 7000018777 850 Spares for 220kV GIS 1000058302 220KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED
72 7000018777 860 Spares for 220kV GIS 1000058297 220KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED
73 7000018777 870 Spares for 220kV GIS 1000058301 220KV GIS- 1600A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 INCLUDED
74 7000018777 880 Spares for 220kV GIS 1000049497 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-220kV GIS SET 1 INCLUDED
75 7000018777 890 Spares for 220kV GIS 1000058284 220KV GIS-ONE POLE OF 1600A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT SET 1 INCLUDED
76 7000018777 900 Spares for 220kV GIS 1000021871 Trip coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED
77 7000018777 910 Spares for 220kV GIS 1000009185 Closing coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED
78 7000018777 920 Spares for 220kV GIS 1000058292 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 220KV GIS CIRCUIT BREAKER SET 1 INCLUDED
79 7000018777 930 Spares for 220kV GIS 1000007066 Auxiliary switch assembly of each type for 245kV GIS Circuit Breaker SET 1 INCLUDED
80 7000018777 940 Spares for 220kV GIS 1000058291 220KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 1 INCLUDED
81 7000018777 950 Spares for 220kV GIS 1000058288 220KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
82 7000018777 960 Spares for 220kV GIS 1000049758 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
83 7000018777 970 Spares for 220kV GIS 1000058272 220KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
84 7000018777 980 Spares for 220kV GIS 1000058290 220KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 INCLUDED
85 7000018777 990 Spares for 220kV GIS 1000049834 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
86 7000018777 1000 Spares for 220kV GIS 1000049794 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
87 7000018777 1010 Spares for 220kV GIS 1000049807 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
88 7000018777 1020 Spares for 220kV GIS 1000049804 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
89 7000018777 1030 Spares for 220kV GIS 1000058289 220KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
90 7000018777 1040 Spares for 220kV GIS 1000049798 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
91 7000018777 1050 Spares for 220kV GIS 1000058293 220KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 INCLUDED
92 7000018777 1060 Spares for 220kV GIS 1000058287 220KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
93 7000018777 1070 Spares for 220kV GIS 1000049797 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC-SPRING OPERATEDMECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREAKER SET 1 INCLUDED
94 7000018777 1080 Spares for 220kV GIS 1000049801 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
95 7000018777 1090 Spares for 220kV GIS 1000058371 220kV GIS- Three phase of 1600Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 INCLUDED
96 7000018777 1100 Spares for 220kV GIS 1000058282 220KV GIS- THREE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED
97 7000018777 1110 Spares for 220kV GIS 1000058278 220KV GIS - THREE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED
98 7000018777 1120 Spares for 220kV GIS 1000058273 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS DISCONNECTORSWITCH SET 1 INCLUDED
99 7000018777 1130 Spares for 220kV GIS 1000058280 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS MAINTENANCE EARTHSWITCH SET 1 INCLUDED
100 7000018777 1140 Spares for 220kV GIS 1000058276 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS FAST EARTHINGSWITCH SET 1 INCLUDED
101 7000018777 1150 Spares for 220kV GIS 1000049773 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-220KV GIS SET 1 INCLUDED
102 7000018777 1160 Spares for 220kV GIS 1000049775 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-220KV GIS SET 1 INCLUDED
103 7000018777 1170 Spares for 220kV GIS 1000049774 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-220KV GIS SET 1 INCLUDED
104 7000018777 1180 Spares for 220kV GIS 1000058274 DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH SET 1 INCLUDED
105 7000018777 1190 Spares for 220kV GIS 1000058281 DRIVE MECHANISM FOR 220KV GIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED
106 7000018777 1200 Spares for 220kV GIS 1000058277 DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH SET 1 INCLUDED
107 7000018777 1210 Spares for 220kV GIS 1000058275 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH EA 1 INCLUDED
108 7000018777 1220 Spares for 220kV GIS 1000058283 MOTOR FOR DRIVE MECHANISM FOR 220KVGIS MAINTENANCE EARTH SWITCH EA 1 INCLUDED
109 7000018777 1230 Spares for 220kV GIS 1000058279 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH EA 1 INCLUDED
110 7000018777 1240 Spares for 220kV GIS 1000058294 220KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (4 CORES) WITHASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALL RESPECT EA 1 INCLUDED
111 7000018777 1250 Spares for 220kV GIS 1000058296 220KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT EA 1 INCLUDED
112 7000018777 1260 Spares for 220kV GIS 1000058303 220KV GIS- SINGLE PHASE GAS INSULATED SURGE ARRESTER WITH ASSOCIATEDENCLOSURE AND INSULATOR COMPLETE IN ALL RESPECT EA 1 INCLUDED
113 7000018777 1270 Spares for 220kV GIS 1000058304 220KV GIS- SURGE COUNTER/ MONITOR EA 1 INCLUDED
114 7000018777 1280 Telecom Eqpt for New Melli 1000028251 Base Equipment STM-4 MADM upto 5 MSP SET 1 INCLUDED
115 7000018777 1290 Telecom Eqpt for New Melli 1000023721 SFP S4.1 EA 6 INCLUDED
116 7000018777 1300 Telecom Eqpt for New Melli 1000023719 SFP L4.1 EA 2 INCLUDED
117 7000018777 1310 Telecom Eqpt for New Melli 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED
118 7000018777 1320 Telecom Eqpt for New Melli 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED
119 7000018777 1330 Telecom Eqpt for New Melli 1000026228 Equipment Cabinets For SDH EA 1 INCLUDED
120 7000018777 1340 Telecom Eqpt for New Melli 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED
121 7000018777 1360 Telecom Spare at New Melli 1000023721 SFP S4.1 EA 1 INCLUDED
122 7000018777 1370 Telecom Spare at New Melli 1000023719 SFP L4.1 EA 1 INCLUDED
123 7000018777 1380 Telecom Equipment at Rangit(NHPC) 1000028251 Base Equipment STM-4 MADM upto 5 MSP SET 1 INCLUDED
124 7000018777 1390 Telecom Equipment at Rangit(NHPC) 1000023721 SFP S4.1 EA 2 INCLUDED
125 7000018777 1400 Telecom Equipment at Rangit(NHPC) 1000023719 SFP L4.1 EA 2 INCLUDED
126 7000018777 1410 Telecom Equipment at Rangit(NHPC) 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED
127 7000018777 1420 Telecom Equipment at Rangit(NHPC) 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED
128 7000018777 1430 Telecom Equipment at Rangit(NHPC) 1000026228 Equipment Cabinets For SDH EA 1 INCLUDED
129 7000018777 1440 Telecom Equipment at Rangit(NHPC) 1000028495 NMS- CRAFT TERMINAL-HARDWARE EA 1 INCLUDED
130 7000018777 1450 Telecom Equipment at Rangit(NHPC) 1000028265 Software for Craft Terminal EA 1 INCLUDED
131 7000018777 1460 Telecom Equipment at Rangit(NHPC) 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED
132 7000018777 1480 Telecom Spares at Rangit(NHPC) 1000031371 SDH EQUIPMENT (STM-4 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 INCLUDED
133 7000018777 1490 Telecom Spares at Rangit(NHPC) 1000023721 SFP S4.1 EA 1 INCLUDED
134 7000018777 1500 Telecom Spares at Rangit(NHPC) 1000023719 SFP L4.1 EA 1 INCLUDED
135 7000018777 1510 Telecom Spares at Rangit(NHPC) 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 INCLUDED
136 7000018777 1520 Telecom Spares at Rangit(NHPC) 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 INCLUDED
137 7000018777 1530 Telecom Spares at Rangit(NHPC) 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 INCLUDED
138 7000018777 1540 Telecom Spares at Rangit(NHPC) 1000031398 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 INCLUDED
TOTAL FOR Local Transportation, In-transit Insurance, Loading and Unloading 0.00
Date Printed Name
Place Designation
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 3
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Installation Charges : (All Prices are in Indian Rupees)
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘8’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable ( in %) Whether rate of GST in column ‘10’ is confirmed. If not indicate applicable rate of GST # Description Unit Quantity Unit Erection Charges Total Erection Charges GST Before Discount Discount Total Price after discount GST After Discount
A 220KV RANGIT IV-NEW MELLI TL
2 7000018805 260 100 20 SURVEY 100002672 998344 18 Detailed Survey including profiling & tower spotting KM 3.85 INCLUDED 0 0 0.0000000000 0 0 0.00
4 7000018805 270 110 10 SOIL INVESTIGATION 100001245 998342 18 Detailed soil investigation: Fissured Rock EA 10 INCLUDED 0 0 0.0000000000 0 0 0.00
5 7000018805 270 110 20 SOIL INVESTIGATION 100001246 998342 18 Detailed soil investigation: Hard Rock EA 4 INCLUDED 0 0 0.0000000000 0 0 0.00
6 7000018805 310 120 10 WORK ASSOCIATED WITH TOWER FOUNDATION 100001257 995433 18 Excavation: Dry Fissured Rock M3 2576 INCLUDED 0 0 0.0000000000 0 0 0.00
7 7000018805 310 120 20 WORK ASSOCIATED WITH TOWER FOUNDATION 100001258 995433 18 Excavation: Wet Fissured Rock M3 1267 INCLUDED 0 0 0.0000000000 0 0 0.00
8 7000018805 310 120 30 WORK ASSOCIATED WITH TOWER FOUNDATION 100001259 995433 18 Excavation: Hard Rock M3 76 INCLUDED 0 0 0.0000000000 0 0 0.00
9 7000018805 310 120 40 WORK ASSOCIATED WITH TOWER FOUNDATION 100001260 995454 18 Concreting (including all associated works related to foundation not covered in excavation and reinforcemt steel works : concreting(1:1.5:3) M3 709 INCLUDED 0 0 0.0000000000 0 0 0.00
10 7000018805 310 120 50 WORK ASSOCIATED WITH TOWER FOUNDATION 100001261 995454 18 Concreting (including all associated works related to foundation not covered in excavation and reinforcemt steel works : LeanConcrete (1:3:6) M3 74 INCLUDED 0 0 0.0000000000 0 0 0.00
11 7000018805 310 120 60 WORK ASSOCIATED WITH TOWER FOUNDATION 100001262 995454 18 Reinforcement Steel : Supply and placement MT 65 INCLUDED 0 0 0.0000000000 0 0 0.00
12 7000018805 310 120 70 WORK ASSOCIATED WITH TOWER FOUNDATION 100001263 995455 18 Installation of stub including bolts and nuts : For Normal Towers MT 14 INCLUDED 0 0 0.0000000000 0 0 0.00
13 7000018805 320 130 10 ERECTION 100001248 995455 18 Erection of various types of towers, tower extensions (complete), bolts & nuts, hangers, d-shackles, step bolts, pack washers etc.including tack welding & supply & application of zinc rich paint : Normal towers MT 333 INCLUDED 0 0 0.0000000000 0 0 0.00
14 7000018805 280 150 10 INSTALLATION OF EARTHING OF TOWERS 100001270 995468 18 Installation of earthing of towers: Counterpoise type (120 m length) EA 7 INCLUDED 0 0 0.0000000000 0 0 0.00
15 7000018805 280 150 20 INSTALLATION OF EARTHING OF TOWERS 100008105 995468 18 Installation of Chemical earthing of towers: Counterpoise Type (120m length). EA 5 INCLUDED 0 0 0.0000000000 0 0 0.00
16 7000018805 280 150 30 INSTALLATION OF EARTHING OF TOWERS 100002203 995468 18 Installation of Shieldwire Earthingincluding PG clamps, Downlead clampsand Earthwire bits i.e Shield wireearthing (Pipe Type/counterpoise type)shall be an addition to earthing oftowers (Pipe type/counterpoisetype)-Counterpoise type EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
17 7000018805 280 150 40 INSTALLATION OF EARTHING OF TOWERS 100001272 995468 18 Installation of earthing of towers: Counterpoise type (280 m length)* EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
18 7000018805 290 160 10 INSTALLATION OF TOWER ACCESSORIES 100001274 995444 18 Installation of tower accessories : Danger Plate EA 14 INCLUDED 0 0 0.0000000000 0 0 0.00
19 7000018805 290 160 20 INSTALLATION OF TOWER ACCESSORIES 100001275 995444 18 Installation of tower accessories: Number Plate EA 14 INCLUDED 0 0 0.0000000000 0 0 0.00
20 7000018805 290 160 30 INSTALLATION OF TOWER ACCESSORIES 100001276 995444 18 Installation of tower accessories: Phase Plate (Set of three) SET 28 INCLUDED 0 0 0.0000000000 0 0 0.00
21 7000018805 290 160 40 INSTALLATION OF TOWER ACCESSORIES 100001278 995444 18 Installation of tower accessories: Circuit Plate (Set of two) SET 14 INCLUDED 0 0 0.0000000000 0 0 0.00
22 7000018805 290 160 50 INSTALLATION OF TOWER ACCESSORIES 100001277 995444 18 Installation of tower accessories: Anti-Climbing Devices EA 14 INCLUDED 0 0 0.0000000000 0 0 0.00
23 7000018805 300 180 10 STRINGING 100002302 995468 18 220kV AC Double circuit with twin conductor / installation of insulator strings complete with arcing horns and necessary hardware,installing and stringing of conductor including fixing of conductor accessories, installing and stringing of OPGW accessories forthe line. KM 3.85 INCLUDED 0 0 0.0000000000 0 0 0.00
24 7000018805 460 290 10 PROTECTION OF TOWER FOOTING 100001264 995456 18 Protection of tower footing (supply and installation): ' Random rubble stone masonary including excavation (1:5 cement mortar) M3 2421 INCLUDED 0 0 0.0000000000 0 0 0.00
25 7000018805 460 290 20 PROTECTION OF TOWER FOOTING 100001265 995456 18 Protection of tower footing (supply and installation): Stone Bound in Galvanising wire netting including excavation M3 612 INCLUDED 0 0 0.0000000000 0 0 0.00
26 7000018805 460 290 30 PROTECTION OF TOWER FOOTING 100001268 995456 18 Protection of tower footing (supply and installation): Backfilling and gap levelling of volumes enclosed by revetment M3 300 INCLUDED 0 0 0.0000000000 0 0 0.00
27 7000018805 460 290 40 PROTECTION OF TOWER FOOTING 100001267 995456 18 Protection of tower footing (supply and installation): M 15 (1:2:4) mixed concrete for top seal cover of revetment M3 18 INCLUDED 0 0 0.0000000000 0 0 0.00
28 7000018805 460 290 50 PROTECTION OF TOWER FOOTING 100004392 995454 18 Plum concrete with 50% hard stone of grade 1:2:4 (stone size not more than 150mm) M3 500 INCLUDED 0 0 0.0000000000 0 0 0.00
29 7000018805 470 300 10 BENCHING 100001252 995432 18 Benching: All kinds of soils except fissured rock,hard rock and sandy soil M3 2317 INCLUDED 0 0 0.0000000000 0 0 0.00
30 7000018805 470 300 20 BENCHING 100001253 995432 18 Benching: Fissured Rock M3 4245 INCLUDED 0 0 0.0000000000 0 0 0.00
32 7000018805 670 330 10 Installation of OPGW 170000265 998716 18 Installation of Joint box above ground (Including Splicing & Testing) : 24 fibres EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00
33 7000018805 670 330 20 Installation of OPGW 170000356 998336 18 Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19" rack or slimline rack: Type 2 (96 Fibre) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
34 7000018805 670 330 30 Installation of OPGW 100002882 998336 18 Fibre Optic Approach cabling: Including installation hardware like ties/clips/cleats, conduits, ducts, supports, fittings,accessories etc.: 24 Fibre KM 1 INCLUDED 0 0 0.0000000000 0 0 0.00
35 7000018805 680 340 10 PILE FOUNDATION 100024536 995451 18 Boring, providing and installation of bored Cast-in-situ RCC vertical piles of specified diameter and of any length below the pilecap with M25 grade of cement concrete, excluding the cost of reinforcement steel but including the cost of boring with temporaryGuide casing, bentonite solution and the length of pile to be embeded in the pile cap (length of pile for payment shall be measuredfrom bottom of pile cap), all necessary labour, materials, plants, tools & tackles etc., complete, as necessary for proper executionof the job. (Boring in all types of rocks excluded). : 1200mm diameter R.C.C.vertical bored pile upto 40 m from bottom of pile cap.. M 208 INCLUDED 0 0 0.0000000000 0 0 0.00
36 7000018805 680 340 20 PILE FOUNDATION 100024549 995451 18 Extra rate over item (1200mm diameter R.C.C.vertical bored pile upto 40 m from bottom of pile cap.) for boring including socketing,anchoring (if required) with required size,nos. & depth of Reinforcement in all types of rocks other than hard rock upto any depthtill founding level M 32 INCLUDED 0 0 0.0000000000 0 0 0.00
37 7000018805 680 340 30 PILE FOUNDATION 100024563 995451 18 Extra rate over item (1200mm diameter R.C.C.vertical bored pile upto 40 m from bottom of pile cap.) for boring including socketing,anchoring (if required) with required size,nos. & depth of Reinforcement in hard rock upto a maximum depth of 10m M 16 INCLUDED 0 0 0.0000000000 0 0 0.00
38 7000018805 680 340 40 PILE FOUNDATION 100001314 995451 18 Excavation where ever required for pile cap /tie etc. (other than boring) for all depth and size, in all types of soils includingdisposal of excavated materials for all lifts and leads,decent etc.as directed by Engineer - In -charge, together with all labour,tools & tackles, sheeting, sheet piling, dewatering etc. complete as required for proper execution of the job. M3 6.9 INCLUDED 0 0 0.0000000000 0 0 0.00
39 7000018805 680 340 50 PILE FOUNDATION 100001315 995451 18 Back filling with available excavatedearth for all leads and lifts in sidesof foundations and other under groundfacilities in horizontal layers notexceeding 20 cm. in depth consolidatingeach deposited layer by ramming andwatering etc. as per specification andinstruction of Engineer -in-charge. M3 10 INCLUDED 0 0 0.0000000000 0 0 0.00
40 7000018805 680 340 60 PILE FOUNDATION 100001316 995451 18 Form work for placing plain or reinforced cement concrete of any type including blockout and section at any elevationshoring,shuttering,strutting,propping, scaffolding,tieing,nailing,including all labour, materials, equipments, waste for form,caulking,dismantling & removal of forms etc. complete. M2 102 INCLUDED 0 0 0.0000000000 0 0 0.00
41 7000018805 680 340 70 PILE FOUNDATION 100001317 995451 18 Supply and placing of steelreinforcement of specified grade forR.C.C. work in pile, pile cap, pedestal/chimney, tie beam (if required)including cost of all labours ,materials, straightening, cleaning,cutting, bending, binding etc. allcomplete as per construction drawingand as per instruction ofEngineer-In-Charge. MT 18 INCLUDED 0 0 0.0000000000 0 0 0.00
42 7000018805 680 340 80 PILE FOUNDATION 100001318 995451 18 Providing and laying in position M25Grade reinforced cement concrete forpile caps, pedestal/chimney and tiebeam(if required), excludingreinforcement steel and form work butincluding cement, all necessary toolsand tackles,labour, materials,equipments for handling,transportation,batching, mixing,placing, vibrating,dewatering, curing etc.all complete asper specification and as perinstruction of Engineer-In- Charge(excluding cost of concrete in pileswhich is included in boring of cast insitu RCC vertical piles in therelevent line item. ) M3 100 INCLUDED 0 0 0.0000000000 0 0 0.00
43 7000018805 680 340 90 PILE FOUNDATION 100001319 995451 18 Providing and laying plain cementconcrete 1:4:8 (1cement : 4 coarsesand: 8 graded stone aggregate 40mmnominal size) including cement, allnecessary tools and tackles,labour,materials, equipments forhandling,transportation,mixing,placing,vibrating,dewatering etc.all completeas per Specification . M3 6.5 INCLUDED 0 0 0.0000000000 0 0 0.00
44 7000018805 680 340 100 PILE FOUNDATION 100001320 998346 18 Conducting Standard Penetration Test (SPT) at various elevations in pile bore holes in all kind of soils including all labour,materials, tools and tackles, equipments etc. required for successful completion of the job. EA 32 INCLUDED 0 0 0.0000000000 0 0 0.00
45 7000018805 680 340 110 PILE FOUNDATION 100001321 995451 18 Supply and Providing M.S. liner of 6mm. thick in piles upto 10m. Depth (maxm.) from bottom of pile cap, limited to the approveddrawing, including supply, straightening, bending, welding,all supports, labours, tools and tackles, plants & equipments, withprimer and paintinting etc. (complete) as required for successful completion of the job MT 15 INCLUDED 0 0 0.0000000000 0 0 0.00
46 7000018805 680 340 120 PILE FOUNDATION 100001322 998346 18 Conducting integrity test on pile usingelectronic control unit,hand heldhammer, accelerometer, computer withrequired software to assessas-installed pile characteresticsincluding mobilisation of necessarymanpower, equipments, materials etc.required for successful completion ofthe job EA 16 INCLUDED 0 0 0.0000000000 0 0 0.00
47 7000018785 10 350 10 Labour Camp 100023085 995455 18 ESTABLISHMENT OF LABOUR CAMPS AS PER PROVISION UNDER FACILITIES TO BE INCORPORATED FOR LABOURERS IN TECHNICAL SPECIFICATION LS 1 INCLUDED 0 0 0.0000000000 0 0 0.00
B 220 KV New Melli (PG) GIS S/s extn
1 7000018777 610 1260 20 220kV, 40kA GIS Equipment 100000428 998736 18 220KV, 1600 Amps, Single phase GIS bus duct M 350 INCLUDED 0 0 0.0000000000 0 0 0.00
2 7000018777 610 1260 30 220kV, 40kA GIS Equipment 100003589 998736 18 245kV, 1600A, 40kA Single phase SF6 to Air Bushing SET 6 INCLUDED 0 0 0.0000000000 0 0 0.00
3 7000018777 610 1260 40 220kV, 40kA GIS Equipment 100000382 998736 18 245kV, 1600 A, 40 kA, SF6 GIS Line feeder bay module as per Section-Project, Technical specification SET 2 INCLUDED 0 0 0.0000000000 0 0 0.00
4 7000018777 610 1260 50 220kV, 40kA GIS Equipment 100003583 998736 18 245 kV, 3000 A, 40 kA, SF6 GIS Bus bar module Extension as per Section-Project, Technical specification SET 2 INCLUDED 0 0 0.0000000000 0 0 0.00
5 7000018777 620 1350 10 245kV, 40kA AIS EQUIPMENT 100000448 998736 18 245 kV, 4400pf Capacitive Voltage Transformer (1- Phase) EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
6 7000018777 620 1350 20 245kV, 40kA AIS EQUIPMENT 100000484 998736 18 216kV Surge Arrester (1-phase) EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
7 7000018777 620 1350 30 245kV, 40kA AIS EQUIPMENT 100001907 998736 18 245 kV,1 phase Bus Post Insulator (except for Line Traps) EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
8 7000018777 620 1350 40 245kV, 40kA AIS EQUIPMENT 100000884 998734 18 245 kV ,1 phase Bus Post Insulators for Line Traps EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
9 7000018777 630 1431 10 Erection Hardware for 220 kV GIS 100000512 998731 18 Erection Hardware for 220kV DM-type layout for GIS termination arrangement-Line bay as per specification SET 2 INCLUDED 0 0 0.0000000000 0 0 0.00
10 7000018777 640 1451 10 Earthmat 100003103 998731 18 40 mm MS rod for Main Earthmat KM 1 INCLUDED 0 0 0.0000000000 0 0 0.00
11 7000018777 650 1490 10 CRP for 220kV Bays with SAS at New Melli 100000743 998736 18 Augmentation of existing 220kV bus bar protection scheme.(No. of bays as per specification)-(with Automation) SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00
12 7000018777 650 1490 20 CRP for 220kV Bays with SAS at New Melli 100000738 998736 18 220kV Line Protection Panel (with Automation) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
13 7000018777 650 1490 30 CRP for 220kV Bays with SAS at New Melli 100000736 998736 18 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
14 7000018777 660 1513 10 SAS-AUG 100002070 998736 18 Augmentation of Substation automation System for 220kV bay as per Technical Specification EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
15 7000018777 670 1530 10 PLCC Equipment at New Melli 100000878 998734 18 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
16 7000018777 670 1530 20 PLCC Equipment at New Melli 100000886 998734 18 Coupling device for PLCC EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
17 7000018777 670 1530 30 PLCC Equipment at New Melli 100000888 998734 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
18 7000018777 670 1530 40 PLCC Equipment at New Melli 100000890 998734 18 Protection Coupler (Analog) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
19 7000018777 670 1530 50 PLCC Equipment at New Melli 100000891 998734 18 Digital Protection Coupler EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
20 7000018777 670 1530 60 PLCC Equipment at New Melli 100002762 998734 18 PLCC-Equipments-Telephone Instruments (2 wire) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
21 7000018777 670 1530 70 PLCC Equipment at New Melli 100003517 998734 18 HF CABLE FOR PLCC-75 OHM (KM) KM 1 INCLUDED 0 0 0.0000000000 0 0 0.00
22 7000018777 680 1531 10 PLCC Equipment at Rangit(NHPC) 100003517 998734 18 HF CABLE FOR PLCC-75 OHM (KM) KM 1 INCLUDED 0 0 0.0000000000 0 0 0.00
23 7000018777 680 1531 20 PLCC Equipment at Rangit(NHPC) 100002762 998734 18 PLCC-Equipments-Telephone Instruments (2 wire) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
24 7000018777 680 1531 30 PLCC Equipment at Rangit(NHPC) 100000891 998734 18 Digital Protection Coupler EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
25 7000018777 680 1531 40 PLCC Equipment at Rangit(NHPC) 100000890 998734 18 Protection Coupler (Analog) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
26 7000018777 680 1531 50 PLCC Equipment at Rangit(NHPC) 100000888 998734 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
27 7000018777 680 1531 60 PLCC Equipment at Rangit(NHPC) 100000886 998734 18 Coupling device for PLCC EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
28 7000018777 680 1531 70 PLCC Equipment at Rangit(NHPC) 100000878 998734 18 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
32 7000018777 700 1591 10 POWER & CONTROL CABLE 100002930 998736 18 1.1kV grade 19Cx2.5 sqmm Control Cable KM 0.8 INCLUDED 0 0 0.0000000000 0 0 0.00
33 7000018777 700 1591 20 POWER & CONTROL CABLE 100002927 998736 18 1.1kV grade 14Cx2.5 sqmm Control Cable KM 0.4 INCLUDED 0 0 0.0000000000 0 0 0.00
34 7000018777 700 1591 40 POWER & CONTROL CABLE 100002920 998736 18 1.1kV grade 10Cx2.5 sqmm Control Cable KM 0.5 INCLUDED 0 0 0.0000000000 0 0 0.00
35 7000018777 700 1591 50 POWER & CONTROL CABLE 100003000 998736 18 1.1kV grade 7Cx2.5 sqmm Control Cable KM 0.2 INCLUDED 0 0 0.0000000000 0 0 0.00
36 7000018777 700 1591 60 POWER & CONTROL CABLE 100002994 998736 18 1.1kV grade 5Cx2.5 sqmm Control Cable KM 1.5 INCLUDED 0 0 0.0000000000 0 0 0.00
37 7000018777 700 1591 70 POWER & CONTROL CABLE 100002977 998736 18 1.1kV grade 3Cx2.5 sqmm Control Cable KM 0.4 INCLUDED 0 0 0.0000000000 0 0 0.00
38 7000018777 700 1591 80 POWER & CONTROL CABLE 100002958 998736 18 1.1kV grade 2Cx6 sqmm (PVC) Power Cable KM 0.2 INCLUDED 0 0 0.0000000000 0 0 0.00
39 7000018777 700 1591 90 POWER & CONTROL CABLE 100002992 998736 18 1.1kV grade 4Cx6 sqmm (PVC) Power Cable KM 0.8 INCLUDED 0 0 0.0000000000 0 0 0.00
40 7000018777 710 1620 10 ILLUMINATION SYSTEM 100001021 995461 18 Lighting Panel type ACP-2 as per technical specification EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
41 7000018777 710 1620 20 ILLUMINATION SYSTEM 100001024 998731 18 Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
42 7000018777 710 1620 30 ILLUMINATION SYSTEM 100001052 998731 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) as per technical specifications EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
43 7000018777 710 1620 40 ILLUMINATION SYSTEM 100004852 998731 18 Lighting Fixture LED Luminaires type FL-1 as per tech. specifications EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
44 7000018777 710 1620 50 ILLUMINATION SYSTEM 100004926 998731 18 Lighting Fixture LED Luminaires type FL2 as per tech. specifications EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
45 7000018777 740 1670 10 Civil Works 100004518 995433 18 Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 1962 INCLUDED 0 0 0.0000000000 0 0 0.00
46 7000018777 740 1670 20 Civil Works 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 134 INCLUDED 0 0 0.0000000000 0 0 0.00
47 7000018777 740 1670 30 Civil Works 100001326 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 5 INCLUDED 0 0 0.0000000000 0 0 0.00
48 7000018777 740 1670 40 Civil Works 100001328 995454 18 Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) M3 23 INCLUDED 0 0 0.0000000000 0 0 0.00
49 7000018777 740 1670 50 Civil Works 100001754 995454 18 Providing and laying of Reinforced Cement Concrete 1:1.5:3 including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 500 INCLUDED 0 0 0.0000000000 0 0 0.00
50 7000018777 740 1670 60 Civil Works 100001329 995454 18 Steel Reinforcement MT 35 INCLUDED 0 0 0.0000000000 0 0 0.00
51 7000018777 740 1670 70 Civil Works 100001331 995455 18 Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 9 INCLUDED 0 0 0.0000000000 0 0 0.00
52 7000018777 740 1670 80 Civil Works 100001714 995428 18 Stone spreading in switchyard excluding PCC M2 300 INCLUDED 0 0 0.0000000000 0 0 0.00
53 7000018777 740 1670 90 Civil Works 100001713 995424 18 Antiweed treatment M2 300 INCLUDED 0 0 0.0000000000 0 0 0.00
54 7000018777 740 1670 100 Civil Works 100001736 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as perspecification. M 20 INCLUDED 0 0 0.0000000000 0 0 0.00
55 7000018777 740 1670 110 Civil Works 100001735 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as perspecification. M 20 INCLUDED 0 0 0.0000000000 0 0 0.00
56 7000018777 740 1670 120 Civil Works 100001412 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section A-A M 150 INCLUDED 0 0 0.0000000000 0 0 0.00
57 7000018777 740 1670 130 Civil Works 100001413 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section B-B M 50 INCLUDED 0 0 0.0000000000 0 0 0.00
58 7000018777 740 1670 160 Civil Works 100004507 995421 18 3.75m wide Cement Concrete road with PCC shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS.However, reinforcement steel and all type concrete shall be paid separately under relevant items M2 375 INCLUDED 0 0 0.0000000000 0 0 0.00
59 7000018777 740 1670 170 Civil Works 100001737 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as perspecification. M 20 INCLUDED 0 0 0.0000000000 0 0 0.00
60 7000018777 740 1670 180 Civil Works 100004463 995456 18 Random Rubble masonry for Retaining wall with locally available stone in cement sand mortar 1:6 (1 Cement: 6 coarse sand) includinglevelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size), Raised and Cutpointing on exposed surface, weep holes/PVC pipe sleeves of 100 mm dia (medium class) @ 1 metre C/C staggered . The top of theretaining wall to be provided with cement concrete 1:2:4. However items of excavation, concrete (1:2:4) shall be payable underrespective items of BPS M3 100 INCLUDED 0 0 0.0000000000 0 0 0.00
61 7000018777 740 1670 190 Civil Works 100003295 995429 18 Dismantling of RCC in foundation including disposal of debris and reinforcement bars of dismantled RCC works within substationboundaries as per direction of enginner incahrge M3 20 INCLUDED 0 0 0.0000000000 0 0 0.00
62 7000018777 720 1680 10 220kV Equipment support structures 100001225 995455 18 Erection of Pipe Structure - 220 kV 1-Phase BPI including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
63 7000018777 720 1680 20 220kV Equipment support structures 100001221 995455 18 Erection of Pipe Structure - 220 kV 1-Phase CVT including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
64 7000018777 720 1680 30 220kV Equipment support structures 100001224 995455 18 Erection of Pipe Structure - 220 kV 1-Phase SA including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
65 7000018777 720 1680 40 220kV Equipment support structures 100003521 995455 18 Erection of Pipe Structure - 220 kV 1 - PH BPI for WT including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts SET 12 INCLUDED 0 0 0.0000000000 0 0 0.00
66 7000018777 720 1680 50 220kV Equipment support structures 100001674 995455 18 Erection of 28mm dia foundation bolts including nuts, checknuts, washers and packplates. EA 108 INCLUDED 0 0 0.0000000000 0 0 0.00
67 7000018777 730 1690 10 220 KV TOWERS 100001210 995455 18 Erection of Lattice Structures (MS Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts MT 39 INCLUDED 0 0 0.0000000000 0 0 0.00
68 7000018777 730 1690 20 220 KV TOWERS 100001681 995455 18 Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 6.5 INCLUDED 0 0 0.0000000000 0 0 0.00
69 7000018777 730 1690 30 220 KV TOWERS 100001680 995455 18 Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 2.4 INCLUDED 0 0 0.0000000000 0 0 0.00
70 7000018777 1350 20 30 Telecom Service at New Melli 170000643 998336 18 Installation of STM-4 ADM Base Equipment EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
71 7000018777 1350 20 40 Telecom Service at New Melli 170000427 998734 18 Optical Interface Cards/SFP# -S4.1 SDH Equipment -STM-4 EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
72 7000018777 1350 20 50 Telecom Service at New Melli 170000428 998734 18 Optical Interface Cards/SFP# -L4.1 for SDH Equipment-STM-4 EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
73 7000018777 1350 20 60 Telecom Service at New Melli 100002825 998734 18 Tributary interface- E1 interface (Minimum 16 nos.) SET 2 INCLUDED 0 0 0.0000000000 0 0 0.00
74 7000018777 1350 20 70 Telecom Service at New Melli 170000550 998336 18 Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
75 7000018777 1350 20 80 Telecom Service at New Melli 170000375 998734 18 Equipment Cabinets-For SDH Equipments EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
76 7000018777 1350 20 110 Telecom Service at New Melli 170000551 998336 18 VOIP telephone instrument with one common switch (min. 8 port) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
77 7000018777 1470 50 10 Telecom Service at Rangit(NHPC) 170000154 998336 18 STM-4 ADM Base Equipment (Common cards, Power supply cards, patch cords, power cabling, tributary cables, other hardware &accessories including sub-racks etc. ) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
78 7000018777 1470 50 20 Telecom Service at Rangit(NHPC) 170000427 998734 18 Optical Interface Cards/SFP# -S4.1 SDH Equipment -STM-4 EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
79 7000018777 1470 50 30 Telecom Service at Rangit(NHPC) 170000428 998734 18 Optical Interface Cards/SFP# -L4.1 for SDH Equipment-STM-4 EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
80 7000018777 1470 50 40 Telecom Service at Rangit(NHPC) 100002825 998734 18 Tributary interface- E1 interface (Minimum 16 nos.) SET 2 INCLUDED 0 0 0.0000000000 0 0 0.00
81 7000018777 1470 50 50 Telecom Service at Rangit(NHPC) 170000550 998336 18 Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
82 7000018777 1470 50 60 Telecom Service at Rangit(NHPC) 170000375 998734 18 Equipment Cabinets-For SDH Equipments EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
83 7000018777 1470 50 70 Telecom Service at Rangit(NHPC) 170000376 998734 18 NMS-Craft Terminal-Hardware EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
84 7000018777 1470 50 80 Telecom Service at Rangit(NHPC) 170000377 998734 18 NMS-Craft Terminal-Software EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
85 7000018777 1470 50 90 Telecom Service at Rangit(NHPC) 170000551 998336 18 VOIP telephone instrument with one common switch (min. 8 port) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
Total of Schedule-3 0.00 0.00 0.00 0.00
# In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date Printed Name
Place Designation
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 4
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Training Charges :
SI. No. PR No Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘…’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable ( in %) Whether rate of GST in column ‘---’ is confirmed. If not indicate applicable rate of GST # Description Unit Quantity Unit Charges Total Charges
Place Printed Name
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 5
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SUMMARY OF TAXES & DUTIES not included in Schedule 1 & 3)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST on Goods 0.00 Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00 Sales Tax 0.00 Sales Tax 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 5
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST on Goods 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 6
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+5]
Date : Printed Name :
Place : Designation :
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 6 After Discount
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2
Local Transportation, Insurance and other Incidental Services
3 TOTAL SCHEDULE NO. 3
Installation Charges
4 TOTAL SCHEDULE NO. 4
Training Charges
5 TOTAL SCHEDULE NO. 5
Taxes and Duties
6 TOTAL SCHEDULE NO. 7
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5]
Date : Printed Name :
Place : Designation :
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 6
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR) From Sch-6 Discount Factors
1 TOTAL SCHEDULE NO. 1 0.00 0.00 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00 0.00 0.00
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00 0.00 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+5]
Date : Printed Name :
Place : Designation :
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule 7
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
Bidder’s Name and Address (Sole Bidder) : To:
Name : Contract Services
Address : Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
SL. NO. PR No Line Item No Code HSN of the Equipment /item for which type test is to be conducted Whether HSN in column ‘---’ is confirmed. If not indicate applicable the HSN code # Rate of GST applicable ( in %) Whether rate of GST in column ‘---’ is confirmed. If not indicate applicable rate of GST # Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
Date Printed Name
Place Designation
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
SL. NO. Description of Test #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
This letter of discount is optional. Bidder may / may not offer any discount.
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Letter of Discount
LETTER OF DISCOUNT
Contract Services Schedule 1 0.00
Power Grid Corporation of India Ltd., Schedule 2 0.00
"Saudamini", Plot No.-2 Schedule 3 0.00
Sector-29, (near IFFCO Chowk) Total 0.00
Gurgaon (Haryana) - 122001
Subject : Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Sch-1 Sch-2 Sch-3
1 Discount on lum-sum basis on total price quoted by us without GST. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2, Sch-3, Sch-4 & Sch-7] In Rs. 0.00 0.00 0.00
2 Discount on percent basis on total price quoted by us without GST. [The discount shall be applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 , Sch-3, Sch-4 & Sch-7] In Percent (%) 0.00 0.00 0.00
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Rs. 0.00
Schedule-3 : Installation Charges In Rs. 0.00
Schedule-4 : Training Charges In Rs.
Schedule-7 : Type Test Charges In Rs.
4 Discount on percent basis on the Schedules as given below : [The discount shall be applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Percent (%) 0.00
Schedule-3 : Installation Charges In Percent (%) 0.00
Schedule-4 : Training Charges In Percent (%)
Schedule-7 : Type Test Charges In Percent (%)
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation. #DIV/0! #DIV/0! #DIV/0! #DIV/0! #REF!
[Discount will not be calculated autometically. However, the same shall be considered during evaluation.]
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain, 0.00 0.00 0.00
Yours faithfully, 0.00000000 0.00000000 0.00000000 Discount Factors
For and on behalf of
Date : Printed Name : 0.00
Place : Designation : 0.00
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Bid Form 2nd Envelope Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
0 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
"Saudamini", Plot No.-2 11 th 11 November
Sector-29, 12 th 12 December
Gurgaon (Haryana) - 122001 13 th
Name of Contract : Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. 15 th
Dear Ladies and/or Gentlemen, 16 th
1.0 In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. 0/- () or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. 17 th
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 3 Installation Charges. Sole Bidder 23 th
Schedule 4 Training charges for training to be imparted (Not Applicable) 24 th
Schedule 5 Taxes and Duties not included in Schedule 1 & 3 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
Schedule 7 Break-up of Type Test Charges (Not Applicable) 27 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of test
Date : Printed Name : 0.00
Place : Designation : 0.00
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Total Ex-Works Price Direct 0.00
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF!
Total Ex-works Price including Type Test charges #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
^ If the item(s) quoted/considered as "Bought-out" in the bid are manufactured at Bidder's works and confirmed to be supplied under “Direct transaction” by the bidder, then the taxes and duties on such items shall be paid/reimbursed by POWERGRID in line with the provisions of Bidding Documents. For this purpose, at the time of award, the Ex-works price (exclusive of taxes & duties) shall be arrived at from the quoted Ex-works price (inclusive of taxes ad duties) by excluding taxes and duties applicable on such items, as on date of Bid opening, in case of supplies from manufacturer proposed in the bid. During contract execution, the taxes and duties on such items shall be paid/reimbursed at actuals, limited to the rates prevailing on date of Bid opening.
Place : Printed Name : --
Total F&I Price (=SUM(I16:I27))
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Total Installaiton Charges #REF!
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Date : (=IF('Sch-1'!B43=0,"", 'Sch-1'!B43)) (="Printed Name : " & IF('Sch-1'!E44=0,"",'Sch-1'!E44))
Place : (=IF('Sch-1'!B44=0,"", 'Sch-1'!B44)) (="Designation : " & IF('Sch-1'!E45=0,"",'Sch-1'!E45))
TOTAL TYPE TEST CHARGES (=SUM(I17:I18))
Date : (='Sch-1'!B43) (="Printed Name : " & 'Sch-1'!E44)
Place : (='Sch-1'!B44) (="Designation : " & 'Sch-1'!E45)
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
#REF! 0.00 #REF! 0.00 #REF!
#REF! #REF! #N/A
#REF! #REF! 0 #REF! #REF! 0
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 0 0 #REF! plus
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 0 1 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 1 0 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 1 1 #REF!
#REF! 0 1 0 0 #REF!
1 One 1 One 1 One 1 One #REF! 0 1 0 1 #REF!
2 Two 2 Two 2 Two 2 Two #REF! 0 1 1 0 #REF!
3 Three 3 Three 3 Three 3 Three #REF! 0 1 1 1 #REF!
4 Four 4 Four 4 Four 4 Four #REF! 1 0 0 0 #REF!
5 Five 5 Five 5 Five 5 Five #REF! 1 0 0 1 #REF!
6 Six 6 Six 6 Six 6 Six #REF! 1 0 1 0 #REF!
7 Seven 7 Seven 7 Seven 7 Seven #REF! 1 0 1 1 #REF!
8 Eight 8 Eight 8 Eight 8 Eight #REF! 1 1 0 0 #REF!
9 Nine 9 Nine 9 Nine 9 Nine #REF! 1 1 0 1 #REF!
10 Ten 10 Ten 10 Ten 10 Ten #REF! 1 1 1 0 #REF!
11 Eleven 11 Eleven 11 Eleven 11 Eleven #REF! 1 1 1 1 #REF!
12 Twelve 12 Twelve 12 Twelve 12 Twelve
13 Thirteen 13 Thirteen 13 Thirteen 13 Thirteen
14 Fourteen 14 Fourteen 14 Fourteen 14 Fourteen
15 Fifteen 15 Fifteen 15 Fifteen 15 Fifteen
16 Sixteen 16 Sixteen 16 Sixteen 16 Sixteen #REF! 0 0 0 0 #REF! +
17 Seventeen 17 Seventeen 17 Seventeen 17 Seventeen #REF! 0 0 0 1 #REF! /- +
18 Eighteen 18 Eighteen 18 Eighteen 18 Eighteen #REF! 0 0 1 0 #REF! /-
19 Nineteen 19 Nineteen 19 Nineteen 19 Nineteen #REF! 0 0 1 1 #REF!
20 Twenty 20 Twenty 20 Twenty 20 Twenty #REF! 0 1 0 0 #REF!
21 Twenty One 21 Twenty One 21 Twenty One 21 Twenty One #REF! 0 1 0 1 #REF!
22 Twenty Two 22 Twenty Two 22 Twenty Two 22 Twenty Two #REF! 0 1 1 0 #REF!
23 Twenty Three 23 Twenty Three 23 Twenty Three 23 Twenty Three #REF! 0 1 1 1 #REF!
24 Twenty Four 24 Twenty Four 24 Twenty Four 24 Twenty Four #REF! 1 0 0 0 #REF!
25 Twenty Five 25 Twenty Five 25 Twenty Five 25 Twenty Five #REF! 1 0 0 1 #REF!
26 Twenty Six 26 Twenty Six 26 Twenty Six 26 Twenty Six #REF! 1 0 1 0 #REF!
27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 27 Twenty Seven #REF! 1 0 1 1 #REF!
28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 28 Twenty Eight #REF! 1 1 0 0 #REF!
29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 29 Twenty Nine #REF! 1 1 0 1 #REF!
30 Thirty 30 Thirty 30 Thirty 30 Thirty #REF! 1 1 1 0 #REF!
31 Thirty One 31 Thirty One 31 Thirty One 31 Thirty One #REF! 1 1 1 1 #REF!
32 Thirty Two 32 Thirty Two 32 Thirty Two 32 Thirty Two
33 Thirty Three 33 Thirty Three 33 Thirty Three 33 Thirty Three
34 Thirty Four 34 Thirty Four 34 Thirty Four 34 Thirty Four
35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr
36 Thirty Six 36 Thirty Six 36 Thirty Six 36 Thirty Six
37 Thirty Seven 37 Thirty Seven 37 Thirty Seven 37 Thirty Seven
38 Thirty Eight 38 Thirty Eight 38 Thirty Eight 38 Thirty Eight
39 Thirty Nine 39 Thirty Nine 39 Thirty Nine 39 Thirty Nine
40 Forty 40 Forty 40 Forty 40 Forty
41 Forty One 41 Forty One 41 Forty One 41 Forty One
42 Forty Two 42 Forty Two 42 Forty Two 42 Forty Two
43 Forty Three 43 Forty Three 43 Forty Three 43 Forty Three
44 Forty Four 44 Forty Four 44 Forty Four 44 Forty Four
45 Forty Five 45 Forty Five 45 Forty Five 45 Forty Five
46 Forty Six 46 Forty Six 46 Forty Six 46 Forty Six
47 Forty Seven 47 Forty Seven 47 Forty Seven 47 Forty Seven
48 Forty Eight 48 Forty Eight 48 Forty Eight 48 Forty Eight
49 Forty Nine 49 Forty Nine 49 Forty Nine 49 Forty Nine
50 Fifty 50 Fifty 50 Fifty 50 Fifty
51 Fifty One 51 Fifty One 51 Fifty One 51 Fifty One
52 Fifty Two 52 Fifty Two 52 Fifty Two 52 Fifty Two
53 Fifty Three 53 Fifty Three 53 Fifty Three 53 Fifty Three
54 Fifty Four 54 Fifty Four 54 Fifty Four 54 Fifty Four
55 Fifty Five 55 Fifty Five 55 Fifty Five 55 Fifty Five
56 Fifty Six 56 Fifty Six 56 Fifty Six 56 Fifty Six
57 Fifty Seven 57 Fifty Seven 57 Fifty Seven 57 Fifty Seven
58 Fifty Eight 58 Fifty Eight 58 Fifty Eight 58 Fifty Eight
59 Fifty Nine 59 Fifty Nine 59 Fifty Nine 59 Fifty Nine
60 Sixty 60 Sixty 60 Sixty 60 Sixty
61 Sixty One 61 Sixty One 61 Sixty One 61 Sixty One
62 Sixty Two 62 Sixty Two 62 Sixty Two 62 Sixty Two
63 Sixty Three 63 Sixty Three 63 Sixty Three 63 Sixty Three
64 Sixty Four 64 Sixty Four 64 Sixty Four 64 Sixty Four
65 Sixty Five 65 Sixty Five 65 Sixty Five 65 Sixty Five
66 Sixty Six 66 Sixty Six 66 Sixty Six 66 Sixty Six
67 Sixty Seven 67 Sixty Seven 67 Sixty Seven 67 Sixty Seven
68 Sixty Eight 68 Sixty Eight 68 Sixty Eight 68 Sixty Eight
69 Sixty Nine 69 Sixty Nine 69 Sixty Nine 69 Sixty Nine
70 Seventy 70 Seventy 70 Seventy 70 Seventy
71 Seventy One 71 Seventy One 71 Seventy One 71 Seventy One
72 Seventy Two 72 Seventy Two 72 Seventy Two 72 Seventy Two
73 Seventy Three 73 Seventy Three 73 Seventy Three 73 Seventy Three
74 Seventy Four 74 Seventy Four 74 Seventy Four 74 Seventy Four
75 Seventy Five 75 Seventy Five 75 Seventy Five 75 Seventy Five
76 Seventy Six 76 Seventy Six 76 Seventy Six 76 Seventy Six
77 Seventy Seven 77 Seventy Seven 77 Seventy Seven 77 Seventy Seven
78 Seventy Eight 78 Seventy Eight 78 Seventy Eight 78 Seventy Eight
79 Seventy Nine 79 Seventy Nine 79 Seventy Nine 79 Seventy Nine
80 Eighty 80 Eighty 80 Eighty 80 Eighty
81 Eighty One 81 Eighty One 81 Eighty One 81 Eighty One
82 Eighty Two 82 Eighty Two 82 Eighty Two 82 Eighty Two
83 Eighty Three 83 Eighty Three 83 Eighty Three 83 Eighty Three
84 Eighty Four 84 Eighty Four 84 Eighty Four 84 Eighty Four
85 Eighty Five 85 Eighty Five 85 Eighty Five 85 Eighty Five
86 Eighty Six 86 Eighty Six 86 Eighty Six 86 Eighty Six
87 Eighty Seven 87 Eighty Seven 87 Eighty Seven 87 Eighty Seven
88 Eighty Eight 88 Eighty Eight 88 Eighty Eight 88 Eighty Eight
89 Eighty Nine 89 Eighty Nine 89 Eighty Nine 89 Eighty Nine
90 Ninety 90 Ninety 90 Ninety 90 Ninety
91 Ninety One 91 Ninety One 91 Ninety One 91 Ninety One
92 Ninety Two 92 Ninety Two 92 Ninety Two 92 Ninety Two
93 Ninety Three 93 Ninety Three 93 Ninety Three 93 Ninety Three
94 Ninety Four 94 Ninety Four 94 Ninety Four 94 Ninety Four
95 Ninety Five 95 Ninety Five 95 Ninety Five 95 Ninety Five
96 Ninety Six 96 Ninety Six 96 Ninety Six 96 Ninety Six
97 Ninety Seven 97 Ninety Seven 97 Ninety Seven 97 Ninety Seven
98 Ninety Eight 98 Ninety Eight 98 Ninety Eight 98 Ninety Eight
99 Ninety Nine 99 Ninety Nine 99 Ninety Nine 99 Ninety Nine
100 One Hundred 100 One Hundred 100 One Hundred 100 One Hundred
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Name of Package Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Package No : TL-01
Specification No. : 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5
Completion Period 16 Months
: Transmission Line Package -TL-01 : General guidelines for filling up the Attachments : Transmission Line Package -TL-01 : ORIGINAL
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Specification No.: 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(JV), 3(QR), QR, 4, 4(A), 4(B), 5, 5(A), 6, 7, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 25, 26, 27 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufacture proposed to supply main items.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14-IP.
7 Attachment 20 KMP Declaration : Format enclosed in Volume-III of the Bidding Documents.
8 Attachment 21 Authorization certificate issued by Domestic Manufacturer for selling Domestically Manufactured Iron & Steel Products : Format enclosed in Volume-III of the Bidding Documents.
9 Attachment 22: Affidavit of Self certification regarding Domestic Value Addition in Iron & Steel Products : Format enclosed in Volume-III of the Bidding Documents.
10 Attachment 23 Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
11 Attachment 24: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
12 Attachment 25: Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA : Format enclosed in Volume-III of the Bidding Documents.
13 Attachment 26: Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
14 Attachment 27: Certification by the Bidder per DoE Order in line with ITB Clause 2.1
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Sole Bidder 1 YES
JV (Joint Venture) 2 or More NO
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 0
Whether the bidder is an MSE (Micro & Small Enterprise)
Enter the Name of Registration Authority
Name of Sole Bidder
Address of Sole Bidder
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-3(JV) TL-01 Sole Bidder TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
This Attachment is Not Applicable
Name(s) and Addresse(s) of other partner(s)
Address : #REF!
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
Date : Printed Name : 0
Place : Designation : 16
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-3(QR) TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Qualifying Requirement Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
For our Qualifying Requirements Data, please refer Attachment-QR of this volume.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-4 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby certify that equipment and materials to be supplied are produced in [Enter the name of country where from equipments & material shall be supplied] eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Enter the name of country where from equipments & material shall be supplied] eligible source country.
Date : Printed Name :
Place : Designation :
country. country. [Enter the name of country where from equipments & material shall be supplied] [Enter the name of country where from equipments & material shall be supplied]
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-4(A) TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-4(B) TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-5 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of the items/ sub-assemblies of supply or services i.e. items, whose price is more than 10% of the Bid Price, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Annexure I to Attachment-5 TL-01
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Annexure I to Attachment-5 TL-01
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Details of the proposed sub-contractor/sub-vendor Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-5(A) TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1. We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package:
S.No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name & Address Category
2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract. .
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-6 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Annexure I toAttachment-6 TL-01
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-7 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Details of Alternative Bid)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
No Alternative Bid
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-9 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Work Completion Schedule)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Period in months from the effective date of Contract
Transmission Line Package - TL01
1 Detailed Engineering and drawing submission
a) commencement
2 Procurement of equipment/ components & assembly
a) commencement
a) commencement
4 Manufacturing
a) commencement
5 Shipments & Delivery
a) commencement
6 Establishment of site office
7 Installation at Site
a) commencement
8 Testing & Pre-commissioning
a) commencement
9 Trial Operation
a) commencement
Date : Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-10 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Guarantee Declaration)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that the equipments offered shall have minimum performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-11 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly, we hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : Printed Name :
Place : Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-12 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.The necessary documentary evidence are enclosed :
Sl. No. Name of Materials Value of co-efficient Name of the published index Value of index
I For Ex Works Price Components of Transmission Line Portion
A For Fabricated Tower Parts (including bolts & nuts)
a Steel Blooms, co-efficient a = Steel Blooms of size 150 mm x 150 mm, as published by IEEMA
b. Electrolytic High Grade Zinc, co-efficient b = IEEMA
c. Labour, Co-efficient l= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
Coefficient ‘a’ shall be between 0.51 to 0.57 and coefficient ‘b’ shall be between 0.08 to 0.10 and coefficient ‘l’ shall be between 0.20 to 0.24 and sum of Coefficients ‘a’, ‘b’ and ‘l’ shall be 0.85
B. Line Materials
B1. AL59 Conductor
1 EC grade aluminium ingots, co-eifciant a = 0.80 Monthly average of “Aluminum LME SELLER Settlement Price including Premium of Al Ingots and Customs duty converted in RS./MT” as published by IEEMA
2 Labour, Co-efficient l= 0.05 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
i) Raw Material
A High Tensile Steel Galvanized Wire, coefficient a = CACMAI/ Nationally recognized published index
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
Coefficient ‘a’ shall be between 0.69 to 0.71 and coefficient ‘l’ shall be between 0.09 to 0.11 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
B1. Hardware Fittings
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
B Electrolytic High Grade Zinc, coefficient b = IEEMA
C Manufacture of Basic Metals, coefficient c= Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2001 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.35 to 0.45 and coefficient ‘b’ shall be between 0.04 to 0.06 and coefficient ‘c’ shall be between 0.18 to 0.22 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’, ‘b’, ‘c’ and ‘l’ shall be 0.80
B2 Conductor Accessories
1 Mid Span Compression Joint for Conductor
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
2 Repair Sleeve for Conductor
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
3(c) Bundle Spacer for Conductor
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
ii) Labour, coefficient l = 0.80 Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
3 Rigid Spacer for Jumper
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
4 Spacer Damper for Conductor
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
B4 Earthwire Accessories
4(a) Mid Span Compression Joint for Earthwire
i) Raw Material
A EC Grade Aluminium Ingots, coefficient a = IEEMA
B Electrolytic High Grade Zinc, coefficient b = IEEMA
C Manufacture of Basic Metals, coefficient c = Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘a’ shall be between 0.35 to 0.45 and coefficient ‘b’ shall be between 0.04 to 0.06 and coefficient ‘c’ shall be between 0.18 to 0.22 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients ‘a’ , 'b' , 'c' and ‘l’ shall be 0.80
4(b) Vibration Damper for Earthwire
i) Raw Material
B Electrolytic High Grade Zinc, coefficient b = IEEMA
C Manufacture of Basic Metals, coefficient c = Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘b’ shall be between 0.06 to 0.08 and coefficient ‘c’ shall be between 0.55 to 0.61 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients 'b' , 'c' and ‘l’ shall be 0.80
4(c) Suspension Clamp for Earthwire
i) Raw Material
B Electrolytic High Grade Zinc, coefficient b = IEEMA
C Manufacture of Basic Metals, coefficient c = Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘b’ shall be between 0.06 to 0.08 and coefficient ‘c’ shall be between 0.55 to 0.61 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients 'b' , 'c' and ‘l’ shall be 0.80
4(d) Tension Clamp for Earthwire
i) Raw Material
B Electrolytic High Grade Zinc, coefficient b = IEEMA
C Manufacture of Basic Metals, coefficient c = Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in). (Base: 2016 = 100) (www.labourbureau.nic.in)
Coefficient ‘b’ shall be between 0.06 to 0.08 and coefficient ‘c’ shall be between 0.55 to 0.61 and coefficient ‘l’ shall be between 0.13 to 0.17 and sum of Coefficients 'b' , 'c' and ‘l’ shall be 0.80
5 Flexible Copper Bond Firm
a EC grade aluminium ingots, co-eifciant a = 0.65 IEEMA
c High Tensile Galvanised Steel wires , co-efficient b = 0.15 IEEMA FALSE FALSE
IEEMA High Carbon Steel Rods , co-efficient b = High Tensile Galvanised Steel wires , co-efficient b =
High Grade Electrolytic Zinc , co-efficient c =
l Labour, Co-efficient l= 0.05 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
II For Ex-works price component of Substation Portion
A AIS Equipment
1 Capacitive VoltageTransformer
a) Raw Material
b) Labour, l= Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
a) Raw Material
b) Labour I= l= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
2 Surge Arrester
a) Raw Material
b) Labour, l= Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
3 PVC/XLPE Insulated Power and Control Cable
a) a=PVC Compound 0.15
b) Published Price of Metal IEEMA
i) Aluminium per MT IEEMA
ii) Copper per MT IEEMA
c) Weight in MT of Metal per kM (Size wise)
4 Substation Structures
i) Lattice Steel Structures & Pipe Structures (including bolts & nuts, washers & foundation bolts)
a) Raw Materials
i) a=Structural steel 0.58 JPC Market Price (Retail) for average Price of Steel Angles of size 50 x 50 x 6 mm of all cities in Rs./MT as published by Joint Plant Committee(JPC).
ii) b=Electrolytic Zinc 0.16 IEEMA
b) Labour 0.11 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
III For Erection Price Component (Transmission Line portion)
1 Installation Price Component [including Civil Works but excluding ‘Supply & Placement of Reinforcement Steel’, ‘Concreting’, Survey, Soil investigation and aviation signal for river crossing towers (if any)]
A High Speed Diesel, coefficient a = Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in)
L Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
Coefficient ‘a’ shall be between 0.20 to 0.24 and coefficient ‘l’ shall be between 0.56 to 0.60 and sum of Coefficients ‘a’ and ‘l’ shall be 0.80
2 Supply & Placement of Reinforcement Steel
A High Speed Diesel, coefficient a = Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
L Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
B Manufacture of Basic Metals, coefficient b = Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
Coefficient ‘a’ shall be between 0.09 to 0.11 and coefficient ‘b’ shall be between 0.63 to 0.67 and coefficient ‘l’ shall be between 0.04 to 0.06 and sum of Coefficients ‘a’, ’b’ and ‘l’ shall be 0.80
3 For Concreting
A High Speed Diesel, coefficient a = Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
L Labour, coefficient l = Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
B Manufacture of cement, lime and plaster, coefficient b = Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
C Cutting, shaping and finishing of stone, coefficient c = Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
Coefficient ‘a’ shall be between 0.18 to 0.22 and coefficient ‘b’ shall be between 0.25 to 0.35 and coefficient ‘c’ shall be between 0.18 to 0.22 and coefficient ‘l’ shall be between 0.09 to 0.11 and sum of Coefficients ‘a’, ’b’, 'c' and ‘l’ shall be 0.80
IV Installation price component of Substation Portion
1 Installation price component (including Civil works but excluding ‘supply & placement of reinforcement steel’ and ‘concreting’)
i Labour I= 0.80 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
Invalid Entry !
2 Supply and Placement of Reinforcement Steel
i HSD 0.10 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii Labour I= 0.05 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
iii Manufacture of Basic Metals 0.65 Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
i HSD 0.20 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii Labour I= 0.10 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
iii Manufacture of cement, lime and plaster 0.30 Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in)
iv Cutting, shaping and finishing of stone 0.20 Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-13 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-14 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Integrity Pact is annexed herewith this Volume.
Date : Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (o).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as
having its Registered Office at
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. Package and Specification Number 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 .POWERGRID values full compliance with all relevant laws of the land, rules, regulations, economic use of resources, and of fairness / transparency in its relations with its Bidders/ Contractors.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity, fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personal interest in the Companies/Agencies participating in the Bidding/Tendering process and all known prejudiced persons.
(2) If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC / PC Act , or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID’s Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles during its participation in the tender process and during the contract execution:
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or during the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC / IPC Act.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/information in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
g) The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may, after following due procedures, ban /blacklist the Bidder/Contractor in line with POWERGRID’s policy for “Black-Listing of Firms / Banning of Business”. The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for forfeiture of the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country, that may impinge on the Anti-corruption principle.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID’s policies.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or its subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of the IEMs have been indicated in the Bidding Documents.
(2) The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings, at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He / She reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his / her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEMs information as sought by him / her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on ’Non-Disclosure of Confidential Information’ and of ‘Absence of Conflict of Interest’. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and recuse himself/herself from that case
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he / she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC / IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) While representing any matter in relation to the Integrity pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter.
(10) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing. Side agreements have not been made.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
(6) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(7) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Integrity Pact Page 8 of 8
Specification No.: 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-15 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Initial Advance
Supply Portion:
Services Portion:
Interest Bearing Engineering Advance
Supply Portion:
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
10. PF Regional Office covered (with Address)
11. Name of Contact Person
12. Contact Details
13. Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
14. 9 digit MICR code printed at bottom in middle, next to cheque no.
15. IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
Date : ……………. Printed Name : …………………….
Place : ………………. Designation : ……………………
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-16 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Additional Information)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder)
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
(iii) Details of Provident Fund Code Number of the Bidder
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-16
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Additional Information)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : #REF! Power Grid Corporation of India Ltd.,
Address : #REF! "Saudamini", Plot No. 2, Sector 29
#REF! Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 OTHER INFORMATION
3.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
3.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-16
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Additional Information)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference): Reference ITB clause 9.3(p)(ii)
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3 (p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Name of Banker `
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid.
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 OTHER INFORMATION
3.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
3.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-17 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-17 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. "Saudamini", Plot No. 2, Sector 29
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-17 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-18 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Safety Pact is annexed herewith this Volume.
Date : Printed Name :
Place : Designation :
Specification No. :5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Attachment-19 TL-01
Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : Printed Name :
Place : Designation :
Specification No 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contract Services 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
"Saudamini", Plot No. 2, Sector 29 11 eleven 11 th 11 November
Gurgaon (Haryana) - 122001 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Transmission line package TL-01 for Part – A: construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
(a) Attachment 1(TL-01) : Bid Security or Online Payment Acknowledgement towards Bid Security (if required) or documentary evidence in support of exemption of Bid Security (submission of Hard Copy in “Original‟ for Bid Security and in “Copy‟ for documentary proof in support of exemption and Online Payment Acknowledgement towards Bid Security ) Bank Guarantee INR 250 Banks certified Cheque twenty 20 twenty 20 th
Online Payment Acknowledgement towards Bid Security for a sum of INR Enter details here.
OR documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 13.1 of ITB, Section-II Online Payment INR
(b) Attachment 2(TL-01) : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee (250) 21 st
(c) Attachment 3(TL-01) : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). Sole Bidder Online Payment 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). 0 #REF! Applicable 23 th
Further the required deed of Joint Undertaking signed by us and Tower Manufacturer has also been furnished as per your format. Not Applicable 24 th
(d) Attachment 4(TL-01) : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5(TL-01) : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A(TL-01) : (Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises): The details of the items, components, raw material, services which is proposed to bought/availed from Micro and Small Enterprises for the purpose of completion of works.
(g) Attachment 6(TL-01) : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7(TL-01) : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 28 th
(i) Attachment 8(TL-01) : Manufacturer’s Authorisation Forms. 29 th
(j) Attachment 9(TL-01) : Work Completion Schedule. 30 th
(k) Attachment 10(TL-01) : Guarantee Declaration. 31 st
(l) Attachment 11(TL-01) : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12(TL-01) : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13(TL-01) : Declaration regarding Social Accountability.
(o) Attachment 14(TL-01) : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15(TL-01) : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16(TL-01) : Additional Information.
(r) Attachment 17(TL-01) : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18(TL-01) : Safety Pact
(t) Attachment 19(TL-01) : Declaration.
(u) Attachment 20(TL-01) : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 21(TL-01) : Authorization certificate issued by Domestic Manufacturer for selling Domestically Manufactured Iron & Steel Products
(w) Attachment 22(TL-01) : Affidavit of Self certification regarding Domestic Value Addition in Iron & Steel Products
(x) Attachment 23(TL-01) : Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
(y) Attachment 24(TL-01) : Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
(z) Attachment 25((TL-01) : Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA.
(aa) Attachment 26(TL-01) : Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
(bb) Attachment 27(TL-01) : Certification by the Bidder as per DoE Order in line with ITB Clause 2.1
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
3.0 A * (applicable for MSE only) We are a Micro and Small Enterprise (MSE) registered with................................, a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012, Notification dated 01/06/2020 and 26/06/2020 including subsequent amendments read in conjunction with related notifications issued from time to time for such enterprises. Delete if not applicable
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, insurance, unloading, storage, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 5.1 Contractor’s Responsibilities
(d) GCC 8 Terms of Payment
(e) GCC 9.3 Performance Security
(f) GCC 10 Taxes and Duties
(g) GCC 21.2 Completion Time Guarantee
(h) GCC 22 Defect Liability
(i) GCC 23 Functional Guarantee
(j) GCC 25 Patent Indemnity
(k) GCC 26 Limitation of Liability
(l) GCC 38 Settlement of Disputes
(m) GCC 39 Arbitration
(n) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of Six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:-
Name and address of agent Amount and Currency Purpose of Commission or gratuity
(If none, state “none”)
13.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
#REF! Printed Name :
#REF! Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2(TL-01) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2(TL-01) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Package Name Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
Package Code TL01 Bought-out
Specification No. 5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3, Sch-5, Sch-7 and Bid Form 2nd Envelope.
2 All the cells in Sch-4 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● Fill up applicable rate of Excise Duty. The amount of Excise Duty on the items mentioned as Direct in the mode of transaction in Schedule-1 shall be calculated automatically at the rate mentioned by the bidder here.
● Segregate and fill up the amount on which Sales Tax shall be applicable out of Ex-works supply items mentioned as direct in the mode of transaction in Schedule-1. Applicable Excise Duty on this amount will be calculated automatically at the rate mentioned by the bidder. Further, fill up the rate of applicable Sales Tax. Amount of Sales Tax shall be automatically calculated on the amount mentioned by the bidder as subjected to Sales Tax plus applicable Excise Duty at the rate mentioned by the Bidder.
● Difference of total amount quoted by the bidder as Direct Transaction and the amount mentioned by him subjected to Sales Tax shall be considered as the amount on which VAT shall become applicable and the same shall be calculated & displayed automatically. Applicable Excise Duty on this amount at the rate mentioned by the bidder shall also be calculated & displayed automatically. Fill up the rate of applicable VAT. The amount of VAT shall be calculated automatically on the amount considered to be subjected to VAT plus applicable Excise Duty at the rate mentioned by the bidder here.
● Amount as per details filled up by the bidder in the work sheets Entry Tax, Octroi and other Taxes & Duties shall be displayed in this work sheet Sch-5 but will not be added to the grand total and shall be considered as applicable.
● Click at the links to go to the work sheets Entry Tax, Octroi and other Taxes & Duties one by one.
● Fill the description, amount and rate of applicable Entry Tax. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Fill the description, amount and rate of applicable Octroi. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
Other Taxes & Duties :
● Fill the description, amount and rate of applicable Other Taxes & Duties. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid form 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Sole Bidder 1
JV (Joint Venture) Other Partner
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 1 0
Name of Sole Bidder
Address of Sole Bidder
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule-1
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : Contract Services 0
Name : Power Grid Corporation of India Ltd., #REF!
Address : "Saudamini", Plot No.-2 #REF!
Gurgaon (Haryana) - 122001
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted.
(All Prices are in Indian Rupees)
SI. No. PR No PR Line Item No Activity Description Material Code HSN Code Whether HSN in column ‘6’ is confirmed. If not indicate applicable the HSN code # Rate of GST applicable ( in %) Whether rate of GST in column ‘8’ is confirmed. If not indicate applicable rate of GST # Item Description Unit Qty. Unit Ex-Works Price (excluding GST) Total Ex-Works Price (excluding GST)
A 220KV RANGIT IV-NEW MELLI TL
1 7000018805 10 FABRICATION AND SUPPLY 1000013391 73082011 18 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-HTSteel for Normal Towers MT 226 INCLUDED 0 0 0.00 0.00 0.00 0.00
2 7000018805 20 FABRICATION AND SUPPLY 1000015274 73082011 18 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-MSSteel for Normal Towers MT 89 INCLUDED 0 0 0 0.00 0.00 0.00
3 7000018805 30 FABRICATION AND SUPPLY 1000013393 73082011 18 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-HT Steel for Normal Towers MT 13 INCLUDED 0 0 0 0.00 0.00 0.00
4 7000018805 40 FABRICATION AND SUPPLY 1000015276 73082011 18 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-MS Steel for Normal Towers MT 1.5 INCLUDED 0 0 0 0.00 0.00 0.00
5 7000018805 50 FABRICATION AND SUPPLY 1000013472 73181500 18 Supply of Hexagonal Bolts & Nuts for towers including Step Bolts, SpringWashers etc. MT 17 INCLUDED 0 0 0 0.00 0.00 0.00
6 7000018805 60 FABRICATION AND SUPPLY 1000007847 73181500 18 Supply of Bolts & Nuts for Stubs including Spring Washers etc. MT 0.5 INCLUDED 0 0 0 0.00 0.00 0.00
7 7000018805 70 EARTHING OF TOWERS 1000010003 73082011 18 Supply of Counterpoise type (120 m length) EA 7 INCLUDED 0 0 0 0.00 0.00 0.00
8 7000018805 80 EARTHING OF TOWERS 1000045872 73082011 18 COUNTERPOISE TYPE CHEMICAL EARTHING EA 5 INCLUDED 0 0 0 0.00 0.00 0.00
9 7000018805 90 EARTHING OF TOWERS 1000019717 73082011 18 Supply of Shieldwire Earthing includingPG clamps, downlead clamps butexcluding Earthwire bits forCounterpoise type earthing EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
10 7000018805 100 EARTHING OF TOWERS 1000010005 73082011 18 Counterpoise type (280 m length) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
11 7000018805 150 TOWER ACCESSORIES 1000010538 73082011 18 Danger Plate for 220kV EA 14 INCLUDED 0 0 0 0.00 0.00 0.00
12 7000018805 140 TOWER ACCESSORIES 1000015970 73082011 18 Number Plate for 220kV EA 14 INCLUDED 0 0 0 0.00 0.00 0.00
13 7000018805 110 TOWER ACCESSORIES 1000017508 73082011 18 Phase Plate (Set of three) SET 28 INCLUDED 0 0 0 0.00 0.00 0.00
14 7000018805 120 TOWER ACCESSORIES 1000009119 73082011 18 Circuit Plate (Set of two) SET 14 INCLUDED 0 0 0 0.00 0.00 0.00
15 7000018805 130 TOWER ACCESSORIES 1000006779 73082011 18 Supply of Anti-Climbing Devices ofBarbed Wire Type SET 14 INCLUDED 0 0 0 0.00 0.00 0.00
16 7000018805 160 CONDUCTOR 1000030860 76141000 18 ACSR MOOSE CONDUCTOR KM 47 INCLUDED 0 0 0 0.00 0.00 0.00
17 7000018805 170 INSULATOR 1000009322 85469090 18 Composite long rod Insulators for 220kV Transmission Line-120 KN (Length-2175 mm, Creepage-7595 mm) EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
18 7000018805 180 INSULATOR 1000048899 85469090 18 COMPOSITE LONGROD INSULATOR - 220KV - 160KN (L2550) EA 360 INCLUDED 0 0 0 0.00 0.00 0.00
19 7000018805 190 HARDWARE FITTINGS 1000032564 73082011 18 HARDWARE FITTINGS FOR 220KV AC WITH TWIN ACSR MOOSE CONDUCTOR-DOUBLETENSION STRING SET 180 INCLUDED 0 0 0 0.00 0.00 0.00
20 7000018805 200 HARDWARE FITTINGS 1000032565 73082011 18 HARDWARE FITTINGS FOR 220KV AC WITH ACSR MOOSE CONDUCTOR-SINGLE ISUSPENSION PILOT SET 6 INCLUDED 0 0 0 0.00 0.00 0.00
21 7000018805 210 CONDUCTOR ACCESSORIES 1000015503 76169990 18 Mid Span Compression Joint for Conductor-ACSR Moose EA 23 INCLUDED 0 0 0 0.00 0.00 0.00
22 7000018805 220 CONDUCTOR ACCESSORIES 1000018443 76169990 18 Repair Sleeve for Conductor-ACSR Moose EA 7 INCLUDED 0 0 0 0.00 0.00 0.00
23 7000018805 230 CONDUCTOR ACCESSORIES 1000022431 73082011 18 Vibration Damper for Conductor-ACSR Moose EA 720 INCLUDED 0 0 0 0.00 0.00 0.00
24 7000018805 240 CONDUCTOR ACCESSORIES 1000007935 76169990 18 Bundle Spacer for Conductor-Twin ACSR Moose EA 630 INCLUDED 0 0 0 0.00 0.00 0.00
25 7000018805 250 CONDUCTOR ACCESSORIES 1000018569 76169990 18 Rigid Spacer-450mm suconductor spacing Twin Moose as per specificationand drawing EA 270 INCLUDED 0 0 0 0.00 0.00 0.00
26 7000018805 330 SPARE - INSULATOR 1000048899 85469090 18 COMPOSITE LONGROD INSULATOR - 220KV - 160KN (L2550) EA 36 INCLUDED 0 0 0 0.00 0.00 0.00
27 7000018805 340 SPARE - HARDWARE FITTINGS 1000032564 73082011 18 HARDWARE FITTINGS FOR 220KV AC WITH TWIN ACSR MOOSE CONDUCTOR-DOUBLETENSION STRING SET 4 INCLUDED 0 0 0 0.00 0.00 0.00
28 7000018805 350 SPARE - CONDUCTOR ACCESSORIES 1000015503 76169990 18 Mid Span Compression Joint for Conductor-ACSR Moose EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
29 7000018805 360 SPARE - CONDUCTOR ACCESSORIES 1000018443 76169990 18 Repair Sleeve for Conductor-ACSR Moose EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
30 7000018805 370 SPARE - CONDUCTOR ACCESSORIES 1000022431 73082011 18 Vibration Damper for Conductor-ACSR Moose EA 15 INCLUDED 0 0 0 0.00 0.00 0.00
31 7000018805 380 SPARE - CONDUCTOR ACCESSORIES 1000007935 76169990 18 Bundle Spacer for Conductor-Twin ACSR Moose EA 13 INCLUDED 0 0 0 0.00 0.00 0.00
32 7000018805 390 SPARE - CONDUCTOR ACCESSORIES 1000018569 76169990 18 Rigid Spacer-450mm suconductor spacing Twin Moose as per specificationand drawing EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
33 7000018805 400 SPARE - FABRICATION AND SUPPLY 1000013391 73082011 18 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-HTSteel for Normal Towers MT 2.26 INCLUDED 0 0 0 0.00 0.00 0.00
34 7000018805 410 SPARE - FABRICATION AND SUPPLY 1000015274 73082011 18 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-MSSteel for Normal Towers MT 0.9 INCLUDED 0 0 0 0.00 0.00 0.00
35 7000018805 420 SPARE - FABRICATION AND SUPPLY 1000013393 73082011 18 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-HT Steel for Normal Towers MT 0.13 INCLUDED 0 0 0 0.00 0.00 0.00
36 7000018805 430 SPARE - FABRICATION AND SUPPLY 1000015276 73082011 18 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-MS Steel for Normal Towers MT 0.015 INCLUDED 0 0 0 0.00 0.00 0.00
37 7000018805 440 SPARE - FABRICATION AND SUPPLY 1000013472 73181500 18 Supply of Hexagonal Bolts & Nuts for towers including Step Bolts, SpringWashers etc. MT 0.17 INCLUDED 0 0 0 0.00 0.00 0.00
38 7000018805 450 SPARE - FABRICATION AND SUPPLY 1000007847 73181500 18 Supply of Bolts & Nuts for Stubs including Spring Washers etc. MT 0.005 INCLUDED 0 0 0 0.00 0.00 0.00
39 7000018805 480 OPGW & Accessories 1000030940 85447090 18 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE KM 4.2 INCLUDED 0 0 0 0.00 0.00 0.00
40 7000018805 490 OPGW & Accessories 1000033144 82057000 18 TENSION ASSEMBLY - DEAD END FOR 24 FIBER OPGW SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
41 7000018805 500 OPGW & Accessories 1000031039 82057000 18 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
42 7000018805 510 OPGW & Accessories 1000033146 82057000 18 TENSION ASSEMBLY - DOUBLE TENSION PASS THROUGH ASSEMBLY FOR 24 FIBEROPGW SET 11 INCLUDED 0 0 0.00 0.00 0.00 0.00
43 7000018805 520 OPGW & Accessories 1000022417 82057000 18 Vibration Damper for 24 fibre OPGW EA 52 INCLUDED 0 0 0 0.00 0.00 0.00
44 7000018805 530 OPGW & Accessories 1000010817 82057000 18 Down Lead clamp Assembly for 24 fibre OPGW EA 80 INCLUDED 0 0 0 0.00 0.00 0.00
45 7000018805 540 OPGW & Accessories 1000014198 85353090 18 Joint Box for 24 fibre OPGW EA 3 INCLUDED 0 0 0 0.00 0.00 0.00
46 7000018805 550 OPGW & Accessories 1000023471 85372000 18 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
47 7000018805 560 OPGW & Accessories 1000037545 85447090 18 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
48 7000018805 570 OPGW & Accessories 1000006437 85446090 18 APPROACH CABLE INSTALLATION HARDWARE SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
49 7000018805 580 Spares : OPGW & accessories 1000030940 85447090 18 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
50 7000018805 590 Spares : OPGW & accessories 1000033144 82057000 18 TENSION ASSEMBLY - DEAD END FOR 24 FIBER OPGW SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
51 7000018805 600 Spares : OPGW & accessories 1000031039 82057000 18 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
52 7000018805 610 Spares : OPGW & accessories 1000033146 82057000 18 TENSION ASSEMBLY - DOUBLE TENSION PASS THROUGH ASSEMBLY FOR 24 FIBEROPGW SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
53 7000018805 620 Spares : OPGW & accessories 1000022417 82057000 18 Vibration Damper for 24 fibre OPGW EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
54 7000018805 630 Spares : OPGW & accessories 1000010817 82057000 18 Down Lead clamp Assembly for 24 fibre OPGW EA 3 INCLUDED 0 0 0 0.00 0.00 0.00
55 7000018805 640 Spares : OPGW & accessories 1000014198 85353090 18 Joint Box for 24 fibre OPGW EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
56 7000018805 650 Spares : OPGW & accessories 1000037545 85447090 18 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 0.5 INCLUDED 0 0 0 0.00 0.00 0.00
57 7000018805 660 Spares : OPGW & accessories 1000006437 85446090 18 APPROACH CABLE INSTALLATION HARDWARE SET 0.5 INCLUDED 0 0 0 0.00 0.00 0.00
B 220 KV New Melli (PG) GIS S/s extn
1 7000018777 10 220kV, 40kA GIS Equipment 1000001571 85359030 18 245kV,1600A, 40kA,Single phase, SF6 Gas Insulated Bus Duct(GIB) outside GIS Hall alongwith associated support structure M 350 INCLUDED 0 0 0 0.00 0.00 0.00
2 7000018777 20 220kV, 40kA GIS Equipment 1000032764 85389000 18 245KV, 1600A, 40KA SINGLE PHASE SF6 TO AIR BUSHING SET 6 INCLUDED 0 0 0 0.00 0.00 0.00
3 7000018777 30 220kV, 40kA GIS Equipment 1000001679 85359030 18 245kV, 1600 A, 40 kA, SF6 GIS Linefeeder bay module as perSection-Project, Technicalspecification SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
4 7000018777 40 220kV, 40kA GIS Equipment 1000032783 85359030 18 245 KV, 3000 A, 40 KA, SF6 GIS BUS BAR MODULE EXTENSION AS PERSECTION-PROJECT, TECHNICAL SPECIFICATION SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
5 7000018777 50 245kV, 40kA AIS EQUIPMENT 1000001772 85359090 18 245 kV, 4400pf Capacitive Voltage Transformer (1- Phase) EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
6 7000018777 60 245kV, 40kA AIS EQUIPMENT 1000020417 85354010 18 216kV Surge Arrester (1-phase) EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
7 7000018777 70 245kV, 40kA AIS EQUIPMENT 1000001695 85462040 18 245 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
8 7000018777 80 245kV, 40kA AIS EQUIPMENT 1000001694 85462040 18 245 kV ,1 phase Bus Post Insulators for Line Traps EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
9 7000018777 90 Erection Hardware for 220 kV GIS 1000011246 72169990 18 Erection Hardware for 220kV DM-type layout for GIS terminationarrangement-Line bay as per technical specification SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
10 7000018777 100 Earthmat 1000032055 72159090 18 40 MM MS ROD FOR MAIN EARTHMAT KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
11 7000018777 110 CRP for 220kV Bays with SAS at New Melli 1000001167 85371000 18 Augmentation of existing 220kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
12 7000018777 120 CRP for 220kV Bays with SAS at New Melli 1000001330 85371000 18 220kV Line Protection Panel (with Automation) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
13 7000018777 130 CRP for 220kV Bays with SAS at New Melli 1000001170 85371000 18 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
14 7000018777 140 SAS-AUG 1000001333 85371000 18 Augmentation of Substation automation System for 220kV bay as perTechnical Specification EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
15 7000018777 150 PLCC Equipment at New Melli 1000001567 85176210 18 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
16 7000018777 160 PLCC Equipment at New Melli 1000010014 85176210 18 Coupling device for PLCC SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
17 7000018777 170 PLCC Equipment at New Melli 1000000046 85176210 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
18 7000018777 180 PLCC Equipment at New Melli 1000017887 85176210 18 Analog Protection Coupler for PLCC EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
19 7000018777 190 PLCC Equipment at New Melli 1000010638 85176210 18 Digital Protection Coupler EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
20 7000018777 200 PLCC Equipment at New Melli 1000001104 85176210 18 2wire telephone equipment EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
21 7000018777 210 PLCC Equipment at New Melli 1000025769 85176210 18 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
22 7000018777 220 PLCC Equipment at New Melli 1000036908 85446020 18 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
23 7000018777 230 PLCC Equipment at Rangit(NHPC) 1000036908 85446020 18 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
24 7000018777 240 PLCC Equipment at Rangit(NHPC) 1000025769 85176210 18 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
25 7000018777 250 PLCC Equipment at Rangit(NHPC) 1000001104 85176210 18 2wire telephone equipment EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
26 7000018777 260 PLCC Equipment at Rangit(NHPC) 1000010638 85176210 18 Digital Protection Coupler EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
27 7000018777 270 PLCC Equipment at Rangit(NHPC) 1000017887 85176210 18 Analog Protection Coupler for PLCC EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
28 7000018777 280 PLCC Equipment at Rangit(NHPC) 1000000046 85176210 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
29 7000018777 290 PLCC Equipment at Rangit(NHPC) 1000010014 85176210 18 Coupling device for PLCC SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
30 7000018777 300 PLCC Equipment at Rangit(NHPC) 1000001567 85176210 18 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
34 7000018777 340 POWER & CONTROL CABLE 1000031908 85446020 18 1.1KV GRADE 19CX2.5 SQMM CONTROL CABLE KM 0.8 INCLUDED 0 0 0 0.00 0.00 0.00
35 7000018777 350 POWER & CONTROL CABLE 1000031887 85446020 18 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 0.5 INCLUDED 0 0 0 0.00 0.00 0.00
36 7000018777 370 POWER & CONTROL CABLE 1000031964 85446020 18 1.1KV GRADE 3CX2.5 SQMM CONTROL CABLE KM 0.4 INCLUDED 0 0 0 0.00 0.00 0.00
37 7000018777 380 POWER & CONTROL CABLE 1000031985 85446020 18 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 0.8 INCLUDED 0 0 0 0.00 0.00 0.00
38 7000018777 360 POWER & CONTROL CABLE 1000031987 85446020 18 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE KM 1.5 INCLUDED 0 0 0 0.00 0.00 0.00
39 7000018777 390 POWER & CONTROL CABLE 1000031927 85446020 18 1.1KV GRADE 27CX2.5 SQMM CONTROL CABLE KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
40 7000018777 400 POWER & CONTROL CABLE 1000031976 85446020 18 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 0.5 INCLUDED 0 0 0 0.00 0.00 0.00
41 7000018777 410 POWER & CONTROL CABLE 1000031953 85446020 18 1.1KV GRADE 3.5CX35 SQMM (PVC) POWER CABLE KM 1 INCLUDED 0 0 0 0.00 0.00 0.00
42 7000018777 420 ILLUMINATION SYSTEM 1000014547 85371000 18 Lighting Panel type ACP-2 as per technical specification EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
43 7000018777 430 ILLUMINATION SYSTEM 1000017485 94059900 18 Lighting panel SLP for Street Lighting EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
44 7000018777 440 ILLUMINATION SYSTEM 1000004952 94059900 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
45 7000018777 450 ILLUMINATION SYSTEM 1000038387 94051090 18 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
46 7000018777 460 ILLUMINATION SYSTEM 1000038325 94059900 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
47 7000018777 470 220 kV Towers 1000015954 73082011 18 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 39 INCLUDED 0 0 0 0.00 0.00 0.00
48 7000018777 480 220 kV Towers 1000011713 73082011 18 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 2.4 INCLUDED 0 0 0 0.00 0.00 0.00
49 7000018777 490 220 kV Towers 1000012373 73082011 18 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 6.5 INCLUDED 0 0 0 0.00 0.00 0.00
50 7000018777 500 220kV Equipment support structures 1000017562 73045930 18 Standard Pipe Structure for 220kV BPI (excluding wave trap) EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
51 7000018777 510 220kV Equipment support structures 1000020188 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CVT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
52 7000018777 520 220kV Equipment support structures 1000020190 73045930 18 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
53 7000018777 530 220kV Equipment support structures 1000012366 73082011 18 Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 108 INCLUDED 0 0 0 0.00 0.00 0.00
54 7000018777 540 220kV Equipment support structures 1000020191 73045930 18 Fabrication, galvanising and supply of Std Pipe Structure - 220 kV WTincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 12 INCLUDED 0 0 0 0.00 0.00 0.00
55 7000018777 550 SPARES FOR 245kV CVT 1000025934 85359090 18 Spare-245kV CVT SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
56 7000018777 560 SPARES FOR 216kV Surge Arrester 1000025930 85354010 18 Spare-216kV Surge Arrester SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
57 7000018777 570 SPARES FOR 220V BPI 1000027480 85462040 18 Spares-Bus Post Insulator for 765 kV and 400kV system LOT 1 INCLUDED 0 0 0 0.00 0.00 0.00
58 7000018777 580 SPARES FOR CRP 1000019912 85371000 18 Relay & protection Panels (with automation) LS 1 INCLUDED 0 0 0 0.00 0.00 0.00
59 7000018777 590 SPARES FOR SAS 1000019927 85389000 18 Spares-Substation Automation System LS 1 INCLUDED 0 0 0 0.00 0.00 0.00
60 7000018777 600 SPARES FOR PLCC 1000025950 85176210 18 Spare-PLCC SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
61 7000018777 750 Spares for 220kV GIS 1000058295 85359030 18 220KV GIS- CABLE CONNECTION ENCLOSURE WITH MAIN CIRCUIT SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
62 7000018777 760 Spares for 220kV GIS 1000058300 85359030 18 220KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
63 7000018777 770 Spares for 220kV GIS 1000049816 85359030 18 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-220KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00 0.00
64 7000018777 780 Spares for 220kV GIS 1000049752 85359030 18 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-220KV GIS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
65 7000018777 790 Spares for 220kV GIS 1000049761 85359030 18 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-220KV GIS SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
66 7000018777 800 Spares for 220kV GIS 1000058298 85359030 18 220KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
67 7000018777 810 Spares for 220kV GIS 1000049749 85359030 18 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-220KV GIS SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
68 7000018777 820 Spares for 220kV GIS 1000058299 85359030 18 220KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 INCLUDED 0 0 0 0.00 0.00 0.00
69 7000018777 830 Spares for 220kV GIS 1000049782 85359030 18 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES (AS APPLICABLE) IN CLOSE OR OPENPOSITION IN CASE OF REMOVAL OF THE DRIVING MECHANISM-220KV GIS SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
70 7000018777 840 Spares for 220kV GIS 1000049504 85359030 18 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 245KV GIS EA 3 INCLUDED 0 0 0 0.00 0.00 0.00
71 7000018777 850 Spares for 220kV GIS 1000058302 85359030 18 220KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED 0 0 0 0.00 0.00 0.00
72 7000018777 860 Spares for 220kV GIS 1000058297 85359030 18 220KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED 0 0 0 0.00 0.00 0.00
73 7000018777 870 Spares for 220kV GIS 1000058301 85359030 18 220KV GIS- 1600A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
74 7000018777 880 Spares for 220kV GIS 1000049497 85359030 18 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-220kV GIS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
75 7000018777 890 Spares for 220kV GIS 1000058284 85359030 18 220KV GIS-ONE POLE OF 1600A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
76 7000018777 900 Spares for 220kV GIS 1000021871 85389000 18 Trip coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED 0 0 0 0.00 0.00 0.00
77 7000018777 910 Spares for 220kV GIS 1000009185 85389000 18 Closing coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED 0 0 0 0.00 0.00 0.00
78 7000018777 920 Spares for 220kV GIS 1000058292 85359030 18 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 220KV GIS CIRCUIT BREAKER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
79 7000018777 930 Spares for 220kV GIS 1000007066 85389000 18 Auxiliary switch assembly of each type for 245kV GIS Circuit Breaker SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
80 7000018777 940 Spares for 220kV GIS 1000058291 85359030 18 220KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
81 7000018777 950 Spares for 220kV GIS 1000058288 85359030 18 220KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
82 7000018777 960 Spares for 220kV GIS 1000049758 85359030 18 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
83 7000018777 970 Spares for 220kV GIS 1000058272 85359030 18 220KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
84 7000018777 980 Spares for 220kV GIS 1000058290 85359030 18 220KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
85 7000018777 990 Spares for 220kV GIS 1000049834 85359030 18 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
86 7000018777 1000 Spares for 220kV GIS 1000049794 85359030 18 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
87 7000018777 1010 Spares for 220kV GIS 1000049807 85359030 18 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
88 7000018777 1020 Spares for 220kV GIS 1000049804 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
89 7000018777 1030 Spares for 220kV GIS 1000058289 85359030 18 220KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
90 7000018777 1040 Spares for 220kV GIS 1000049798 85359030 18 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
91 7000018777 1050 Spares for 220kV GIS 1000058293 85359030 18 220KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
92 7000018777 1060 Spares for 220kV GIS 1000058287 85359030 18 220KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
93 7000018777 1070 Spares for 220kV GIS 1000049797 85359030 18 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC-SPRING OPERATEDMECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREAKER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
94 7000018777 1080 Spares for 220kV GIS 1000049801 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
95 7000018777 1090 Spares for 220kV GIS 1000058371 85359030 18 220kV GIS- Three phase of 1600Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
96 7000018777 1100 Spares for 220kV GIS 1000058282 85359030 18 220KV GIS- THREE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
97 7000018777 1110 Spares for 220kV GIS 1000058278 85359030 18 220KV GIS - THREE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
98 7000018777 1120 Spares for 220kV GIS 1000058273 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS DISCONNECTORSWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
99 7000018777 1130 Spares for 220kV GIS 1000058280 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS MAINTENANCE EARTHSWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
100 7000018777 1140 Spares for 220kV GIS 1000058276 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS FAST EARTHINGSWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
101 7000018777 1150 Spares for 220kV GIS 1000049773 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-220KV GIS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
102 7000018777 1160 Spares for 220kV GIS 1000049775 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-220KV GIS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
103 7000018777 1170 Spares for 220kV GIS 1000049774 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-220KV GIS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
104 7000018777 1180 Spares for 220kV GIS 1000058274 85359030 18 DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
105 7000018777 1190 Spares for 220kV GIS 1000058281 85359030 18 DRIVE MECHANISM FOR 220KV GIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
106 7000018777 1200 Spares for 220kV GIS 1000058277 85359030 18 DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
107 7000018777 1210 Spares for 220kV GIS 1000058275 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
108 7000018777 1220 Spares for 220kV GIS 1000058283 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 220KVGIS MAINTENANCE EARTH SWITCH EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
109 7000018777 1230 Spares for 220kV GIS 1000058279 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
110 7000018777 1240 Spares for 220kV GIS 1000058294 85359030 18 220KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (4 CORES) WITHASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALL RESPECT EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
111 7000018777 1250 Spares for 220kV GIS 1000058296 85359030 18 220KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
112 7000018777 1260 Spares for 220kV GIS 1000058303 85359030 18 220KV GIS- SINGLE PHASE GAS INSULATED SURGE ARRESTER WITH ASSOCIATEDENCLOSURE AND INSULATOR COMPLETE IN ALL RESPECT EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
113 7000018777 1270 Spares for 220kV GIS 1000058304 85359030 18 220KV GIS- SURGE COUNTER/ MONITOR EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
114 7000018777 1280 Telecom Eqpt for New Melli 1000028251 85176260 18 Base Equipment STM-4 MADM upto 5 MSP SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
115 7000018777 1290 Telecom Eqpt for New Melli 1000023721 85176260 18 SFP S4.1 EA 6 INCLUDED 0 0 0 0.00 0.00 0.00
116 7000018777 1300 Telecom Eqpt for New Melli 1000023719 85176260 18 SFP L4.1 EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
117 7000018777 1310 Telecom Eqpt for New Melli 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
118 7000018777 1320 Telecom Eqpt for New Melli 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
119 7000018777 1330 Telecom Eqpt for New Melli 1000026228 85176290 18 Equipment Cabinets For SDH EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
120 7000018777 1340 Telecom Eqpt for New Melli 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
121 7000018777 1360 Telecom Spare at New Melli 1000023721 85176260 18 SFP S4.1 EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
122 7000018777 1370 Telecom Spare at New Melli 1000023719 85176260 18 SFP L4.1 EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
123 7000018777 1380 Telecom Equipment at Rangit(NHPC) 1000028251 85176260 18 Base Equipment STM-4 MADM upto 5 MSP SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
124 7000018777 1390 Telecom Equipment at Rangit(NHPC) 1000023721 85176260 18 SFP S4.1 EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
125 7000018777 1400 Telecom Equipment at Rangit(NHPC) 1000023719 85176260 18 SFP L4.1 EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
126 7000018777 1410 Telecom Equipment at Rangit(NHPC) 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED 0 0 0 0.00 0.00 0.00
127 7000018777 1420 Telecom Equipment at Rangit(NHPC) 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
128 7000018777 1430 Telecom Equipment at Rangit(NHPC) 1000026228 85176290 18 Equipment Cabinets For SDH EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
129 7000018777 1440 Telecom Equipment at Rangit(NHPC) 1000028495 84715000 18 NMS- CRAFT TERMINAL-HARDWARE EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
130 7000018777 1450 Telecom Equipment at Rangit(NHPC) 1000028265 85238020 18 Software for Craft Terminal EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
131 7000018777 1460 Telecom Equipment at Rangit(NHPC) 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED 0 0 0 0.00 0.00 0.00
132 7000018777 1480 Telecom Spares at Rangit(NHPC) 1000031371 85176260 18 SDH EQUIPMENT (STM-4 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
133 7000018777 1490 Telecom Spares at Rangit(NHPC) 1000023721 85176260 18 SFP S4.1 EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
134 7000018777 1500 Telecom Spares at Rangit(NHPC) 1000023719 85176260 18 SFP L4.1 EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
135 7000018777 1510 Telecom Spares at Rangit(NHPC) 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
136 7000018777 1520 Telecom Spares at Rangit(NHPC) 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
137 7000018777 1530 Telecom Spares at Rangit(NHPC) 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 INCLUDED 0 0 0 0.00 0.00 0.00
138 7000018777 1540 Telecom Spares at Rangit(NHPC) 1000031398 85171890 18 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 INCLUDED 0 0 0 0.00 0.00 0.00
Total Ex-Works Price 0.00 0.00 0.00 0.00 0.00
Total Type Test charges as per Schedule-7 0.00
Total Ex-Works Price including Type Test charges 0.00
# In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date Printed Name
Place Designation
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 2
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Local Transportation, In-transit Insurance, Loading and Unloading
(All Prices are in Indian Rupees)
SI. No. PR No PR Line Item No Activity Description Material Code Description Unit Quantity Unit Freight, In-transit Insurance, loading & Unloading Charges Total Freight, In-transit Insurance, loading & Unloading Charges
A 220KV RANGIT IV-NEW MELLI TL
1 7000018805 10 FABRICATION AND SUPPLY 1000013391 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-HTSteel for Normal Towers MT 226 INCLUDED
2 7000018805 20 FABRICATION AND SUPPLY 1000015274 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-MSSteel for Normal Towers MT 89 INCLUDED
3 7000018805 30 FABRICATION AND SUPPLY 1000013393 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-HT Steel for Normal Towers MT 13 INCLUDED
4 7000018805 40 FABRICATION AND SUPPLY 1000015276 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-MS Steel for Normal Towers MT 1.5 INCLUDED
5 7000018805 50 FABRICATION AND SUPPLY 1000013472 Supply of Hexagonal Bolts & Nuts for towers including Step Bolts, SpringWashers etc. MT 17 INCLUDED
6 7000018805 60 FABRICATION AND SUPPLY 1000007847 Supply of Bolts & Nuts for Stubs including Spring Washers etc. MT 0.5 INCLUDED
7 7000018805 70 EARTHING OF TOWERS 1000010003 Supply of Counterpoise type (120 m length) EA 7 INCLUDED
8 7000018805 80 EARTHING OF TOWERS 1000045872 COUNTERPOISE TYPE CHEMICAL EARTHING EA 5 INCLUDED
9 7000018805 90 EARTHING OF TOWERS 1000019717 Supply of Shieldwire Earthing includingPG clamps, downlead clamps butexcluding Earthwire bits forCounterpoise type earthing EA 1 INCLUDED
10 7000018805 100 EARTHING OF TOWERS 1000010005 Counterpoise type (280 m length) EA 2 INCLUDED
11 7000018805 150 TOWER ACCESSORIES 1000010538 Danger Plate for 220kV EA 14 INCLUDED
12 7000018805 140 TOWER ACCESSORIES 1000015970 Number Plate for 220kV EA 14 INCLUDED
13 7000018805 110 TOWER ACCESSORIES 1000017508 Phase Plate (Set of three) SET 28 INCLUDED
14 7000018805 120 TOWER ACCESSORIES 1000009119 Circuit Plate (Set of two) SET 14 INCLUDED
15 7000018805 130 TOWER ACCESSORIES 1000006779 Supply of Anti-Climbing Devices ofBarbed Wire Type SET 14 INCLUDED
16 7000018805 160 CONDUCTOR 1000030860 ACSR MOOSE CONDUCTOR KM 47 INCLUDED
17 7000018805 170 INSULATOR 1000009322 Composite long rod Insulators for 220kV Transmission Line-120 KN (Length-2175 mm, Creepage-7595 mm) EA 6 INCLUDED
18 7000018805 180 INSULATOR 1000048899 COMPOSITE LONGROD INSULATOR - 220KV - 160KN (L2550) EA 360 INCLUDED
19 7000018805 190 HARDWARE FITTINGS 1000032564 HARDWARE FITTINGS FOR 220KV AC WITH TWIN ACSR MOOSE CONDUCTOR-DOUBLETENSION STRING SET 180 INCLUDED
20 7000018805 200 HARDWARE FITTINGS 1000032565 HARDWARE FITTINGS FOR 220KV AC WITH ACSR MOOSE CONDUCTOR-SINGLE ISUSPENSION PILOT SET 6 INCLUDED
21 7000018805 210 CONDUCTOR ACCESSORIES 1000015503 Mid Span Compression Joint for Conductor-ACSR Moose EA 23 INCLUDED
22 7000018805 220 CONDUCTOR ACCESSORIES 1000018443 Repair Sleeve for Conductor-ACSR Moose EA 7 INCLUDED
23 7000018805 230 CONDUCTOR ACCESSORIES 1000022431 Vibration Damper for Conductor-ACSR Moose EA 720 INCLUDED
24 7000018805 240 CONDUCTOR ACCESSORIES 1000007935 Bundle Spacer for Conductor-Twin ACSR Moose EA 630 INCLUDED
25 7000018805 250 CONDUCTOR ACCESSORIES 1000018569 Rigid Spacer-450mm suconductor spacing Twin Moose as per specificationand drawing EA 270 INCLUDED
26 7000018805 330 SPARE - INSULATOR 1000048899 COMPOSITE LONGROD INSULATOR - 220KV - 160KN (L2550) EA 36 INCLUDED
27 7000018805 340 SPARE - HARDWARE FITTINGS 1000032564 HARDWARE FITTINGS FOR 220KV AC WITH TWIN ACSR MOOSE CONDUCTOR-DOUBLETENSION STRING SET 4 INCLUDED
28 7000018805 350 SPARE - CONDUCTOR ACCESSORIES 1000015503 Mid Span Compression Joint for Conductor-ACSR Moose EA 1 INCLUDED
29 7000018805 360 SPARE - CONDUCTOR ACCESSORIES 1000018443 Repair Sleeve for Conductor-ACSR Moose EA 1 INCLUDED
30 7000018805 370 SPARE - CONDUCTOR ACCESSORIES 1000022431 Vibration Damper for Conductor-ACSR Moose EA 15 INCLUDED
31 7000018805 380 SPARE - CONDUCTOR ACCESSORIES 1000007935 Bundle Spacer for Conductor-Twin ACSR Moose EA 13 INCLUDED
32 7000018805 390 SPARE - CONDUCTOR ACCESSORIES 1000018569 Rigid Spacer-450mm suconductor spacing Twin Moose as per specificationand drawing EA 6 INCLUDED
33 7000018805 400 SPARE - FABRICATION AND SUPPLY 1000013391 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-HTSteel for Normal Towers MT 2.26 INCLUDED
34 7000018805 410 SPARE - FABRICATION AND SUPPLY 1000015274 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-MSSteel for Normal Towers MT 0.9 INCLUDED
35 7000018805 420 SPARE - FABRICATION AND SUPPLY 1000013393 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-HT Steel for Normal Towers MT 0.13 INCLUDED
36 7000018805 430 SPARE - FABRICATION AND SUPPLY 1000015276 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-MS Steel for Normal Towers MT 0.015 INCLUDED
37 7000018805 440 SPARE - FABRICATION AND SUPPLY 1000013472 Supply of Hexagonal Bolts & Nuts for towers including Step Bolts, SpringWashers etc. MT 0.17 INCLUDED
38 7000018805 450 SPARE - FABRICATION AND SUPPLY 1000007847 Supply of Bolts & Nuts for Stubs including Spring Washers etc. MT 0.005 INCLUDED
39 7000018805 480 OPGW & Accessories 1000030940 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE KM 4.2 INCLUDED
40 7000018805 490 OPGW & Accessories 1000033144 TENSION ASSEMBLY - DEAD END FOR 24 FIBER OPGW SET 2 INCLUDED
41 7000018805 500 OPGW & Accessories 1000031039 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 1 INCLUDED
42 7000018805 510 OPGW & Accessories 1000033146 TENSION ASSEMBLY - DOUBLE TENSION PASS THROUGH ASSEMBLY FOR 24 FIBEROPGW SET 11 INCLUDED
43 7000018805 520 OPGW & Accessories 1000022417 Vibration Damper for 24 fibre OPGW EA 52 INCLUDED
44 7000018805 530 OPGW & Accessories 1000010817 Down Lead clamp Assembly for 24 fibre OPGW EA 80 INCLUDED
45 7000018805 540 OPGW & Accessories 1000014198 Joint Box for 24 fibre OPGW EA 3 INCLUDED
46 7000018805 550 OPGW & Accessories 1000023471 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 2 INCLUDED
47 7000018805 560 OPGW & Accessories 1000037545 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 1 INCLUDED
48 7000018805 570 OPGW & Accessories 1000006437 APPROACH CABLE INSTALLATION HARDWARE SET 1 INCLUDED
49 7000018805 580 Spares : OPGW & accessories 1000030940 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE KM 1 INCLUDED
50 7000018805 590 Spares : OPGW & accessories 1000033144 TENSION ASSEMBLY - DEAD END FOR 24 FIBER OPGW SET 1 INCLUDED
51 7000018805 600 Spares : OPGW & accessories 1000031039 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 1 INCLUDED
52 7000018805 610 Spares : OPGW & accessories 1000033146 TENSION ASSEMBLY - DOUBLE TENSION PASS THROUGH ASSEMBLY FOR 24 FIBEROPGW SET 1 INCLUDED
53 7000018805 620 Spares : OPGW & accessories 1000022417 Vibration Damper for 24 fibre OPGW EA 2 INCLUDED
54 7000018805 630 Spares : OPGW & accessories 1000010817 Down Lead clamp Assembly for 24 fibre OPGW EA 3 INCLUDED
55 7000018805 640 Spares : OPGW & accessories 1000014198 Joint Box for 24 fibre OPGW EA 1 INCLUDED
56 7000018805 650 Spares : OPGW & accessories 1000037545 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 0.5 INCLUDED
57 7000018805 660 Spares : OPGW & accessories 1000006437 APPROACH CABLE INSTALLATION HARDWARE SET 0.5 INCLUDED
B 220 KV New Melli (PG) GIS S/s extn
1 7000018777 10 220kV, 40kA GIS Equipment 1000001571 245kV,1600A, 40kA,Single phase, SF6 Gas Insulated Bus Duct(GIB) outside GIS Hall alongwith associated support structure M 350 INCLUDED
2 7000018777 20 220kV, 40kA GIS Equipment 1000032764 245KV, 1600A, 40KA SINGLE PHASE SF6 TO AIR BUSHING SET 6 INCLUDED
3 7000018777 30 220kV, 40kA GIS Equipment 1000001679 245kV, 1600 A, 40 kA, SF6 GIS Linefeeder bay module as perSection-Project, Technicalspecification SET 2 INCLUDED
4 7000018777 40 220kV, 40kA GIS Equipment 1000032783 245 KV, 3000 A, 40 KA, SF6 GIS BUS BAR MODULE EXTENSION AS PERSECTION-PROJECT, TECHNICAL SPECIFICATION SET 2 INCLUDED
5 7000018777 50 245kV, 40kA AIS EQUIPMENT 1000001772 245 kV, 4400pf Capacitive Voltage Transformer (1- Phase) EA 6 INCLUDED
6 7000018777 60 245kV, 40kA AIS EQUIPMENT 1000020417 216kV Surge Arrester (1-phase) EA 6 INCLUDED
7 7000018777 70 245kV, 40kA AIS EQUIPMENT 1000001695 245 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 6 INCLUDED
8 7000018777 80 245kV, 40kA AIS EQUIPMENT 1000001694 245 kV ,1 phase Bus Post Insulators for Line Traps EA 6 INCLUDED
9 7000018777 90 Erection Hardware for 220 kV GIS 1000011246 Erection Hardware for 220kV DM-type layout for GIS terminationarrangement-Line bay as per technical specification SET 2 INCLUDED
10 7000018777 100 Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 1 INCLUDED
11 7000018777 110 CRP for 220kV Bays with SAS at New Melli 1000001167 Augmentation of existing 220kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED
12 7000018777 120 CRP for 220kV Bays with SAS at New Melli 1000001330 220kV Line Protection Panel (with Automation) EA 2 INCLUDED
13 7000018777 130 CRP for 220kV Bays with SAS at New Melli 1000001170 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 2 INCLUDED
14 7000018777 140 SAS-AUG 1000001333 Augmentation of Substation automation System for 220kV bay as perTechnical Specification EA 2 INCLUDED
15 7000018777 150 PLCC Equipment at New Melli 1000001567 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED
16 7000018777 160 PLCC Equipment at New Melli 1000010014 Coupling device for PLCC SET 1 INCLUDED
17 7000018777 170 PLCC Equipment at New Melli 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED
18 7000018777 180 PLCC Equipment at New Melli 1000017887 Analog Protection Coupler for PLCC EA 2 INCLUDED
19 7000018777 190 PLCC Equipment at New Melli 1000010638 Digital Protection Coupler EA 2 INCLUDED
20 7000018777 200 PLCC Equipment at New Melli 1000001104 2wire telephone equipment EA 1 INCLUDED
21 7000018777 210 PLCC Equipment at New Melli 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED
22 7000018777 220 PLCC Equipment at New Melli 1000036908 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED
23 7000018777 230 PLCC Equipment at Rangit(NHPC) 1000036908 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED
24 7000018777 240 PLCC Equipment at Rangit(NHPC) 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED
25 7000018777 250 PLCC Equipment at Rangit(NHPC) 1000001104 2wire telephone equipment EA 1 INCLUDED
26 7000018777 260 PLCC Equipment at Rangit(NHPC) 1000010638 Digital Protection Coupler EA 2 INCLUDED
27 7000018777 270 PLCC Equipment at Rangit(NHPC) 1000017887 Analog Protection Coupler for PLCC EA 2 INCLUDED
28 7000018777 280 PLCC Equipment at Rangit(NHPC) 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED
29 7000018777 290 PLCC Equipment at Rangit(NHPC) 1000010014 Coupling device for PLCC SET 1 INCLUDED
30 7000018777 300 PLCC Equipment at Rangit(NHPC) 1000001567 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED
31 7000018777 310 LT SWITCHGEAR 1000004304 415V ACDB (Extn.) SET 1 INCLUDED
32 7000018777 320 LT SWITCHGEAR 1000001145 220V DCDB (Extn.) SET 1 INCLUDED
33 7000018777 330 LT SWITCHGEAR 1000004755 48V DCDB (Extn.) SET 1 INCLUDED
34 7000018777 340 POWER & CONTROL CABLE 1000031908 1.1KV GRADE 19CX2.5 SQMM CONTROL CABLE KM 0.8 INCLUDED
35 7000018777 350 POWER & CONTROL CABLE 1000031887 1.1KV GRADE 10CX2.5 SQMM CONTROL CABLE KM 0.5 INCLUDED
36 7000018777 370 POWER & CONTROL CABLE 1000031964 1.1KV GRADE 3CX2.5 SQMM CONTROL CABLE KM 0.4 INCLUDED
37 7000018777 380 POWER & CONTROL CABLE 1000031985 1.1KV GRADE 4CX6 SQMM (PVC) POWER CABLE KM 0.8 INCLUDED
38 7000018777 360 POWER & CONTROL CABLE 1000031987 1.1KV GRADE 5CX2.5 SQMM CONTROL CABLE KM 1.5 INCLUDED
39 7000018777 390 POWER & CONTROL CABLE 1000031927 1.1KV GRADE 27CX2.5 SQMM CONTROL CABLE KM 1 INCLUDED
40 7000018777 400 POWER & CONTROL CABLE 1000031976 1.1KV GRADE 4CX16 SQMM (PVC) POWER CABLE KM 0.5 INCLUDED
41 7000018777 410 POWER & CONTROL CABLE 1000031953 1.1KV GRADE 3.5CX35 SQMM (PVC) POWER CABLE KM 1 INCLUDED
42 7000018777 420 ILLUMINATION SYSTEM 1000014547 Lighting Panel type ACP-2 as per technical specification EA 1 INCLUDED
43 7000018777 430 ILLUMINATION SYSTEM 1000017485 Lighting panel SLP for Street Lighting EA 1 INCLUDED
44 7000018777 440 ILLUMINATION SYSTEM 1000004952 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 1 INCLUDED
45 7000018777 450 ILLUMINATION SYSTEM 1000038387 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 2 INCLUDED
46 7000018777 460 ILLUMINATION SYSTEM 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 2 INCLUDED
47 7000018777 470 220 kV Towers 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 39 INCLUDED
48 7000018777 480 220 kV Towers 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 2.4 INCLUDED
49 7000018777 490 220 kV Towers 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 6.5 INCLUDED
50 7000018777 500 220kV Equipment support structures 1000017562 Standard Pipe Structure for 220kV BPI (excluding wave trap) EA 6 INCLUDED
51 7000018777 510 220kV Equipment support structures 1000020188 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV CVT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 6 INCLUDED
52 7000018777 520 220kV Equipment support structures 1000020190 Fabrication, galvanising and supply of Standard Pipe Structure - 220kV SA including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 6 INCLUDED
53 7000018777 530 220kV Equipment support structures 1000012366 Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 108 INCLUDED
54 7000018777 540 220kV Equipment support structures 1000020191 Fabrication, galvanising and supply of Std Pipe Structure - 220 kV WTincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 12 INCLUDED
55 7000018777 550 SPARES FOR 245kV CVT 1000025934 Spare-245kV CVT SET 1 INCLUDED
56 7000018777 560 SPARES FOR 216kV Surge Arrester 1000025930 Spare-216kV Surge Arrester SET 1 INCLUDED
57 7000018777 570 SPARES FOR 220V BPI 1000027480 Spares-Bus Post Insulator for 765 kV and 400kV system LOT 1 INCLUDED
58 7000018777 580 SPARES FOR CRP 1000019912 Relay & protection Panels (with automation) LS 1 INCLUDED
59 7000018777 590 SPARES FOR SAS 1000019927 Spares-Substation Automation System LS 1 INCLUDED
60 7000018777 600 SPARES FOR PLCC 1000025950 Spare-PLCC SET 1 INCLUDED
61 7000018777 750 Spares for 220kV GIS 1000058295 220KV GIS- CABLE CONNECTION ENCLOSURE WITH MAIN CIRCUIT SET 1 INCLUDED
62 7000018777 760 Spares for 220kV GIS 1000058300 220KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 1 INCLUDED
63 7000018777 770 Spares for 220kV GIS 1000049816 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-220KV GIS SET 2 INCLUDED
64 7000018777 780 Spares for 220kV GIS 1000049752 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-220KV GIS SET 1 INCLUDED
65 7000018777 790 Spares for 220kV GIS 1000049761 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-220KV GIS SET 2 INCLUDED
66 7000018777 800 Spares for 220kV GIS 1000058298 220KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 INCLUDED
67 7000018777 810 Spares for 220kV GIS 1000049749 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-220KV GIS SET 2 INCLUDED
68 7000018777 820 Spares for 220kV GIS 1000058299 220KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 INCLUDED
69 7000018777 830 Spares for 220kV GIS 1000049782 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES (AS APPLICABLE) IN CLOSE OR OPENPOSITION IN CASE OF REMOVAL OF THE DRIVING MECHANISM-220KV GIS SET 2 INCLUDED
70 7000018777 840 Spares for 220kV GIS 1000049504 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 245KV GIS EA 3 INCLUDED
71 7000018777 850 Spares for 220kV GIS 1000058302 220KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED
72 7000018777 860 Spares for 220kV GIS 1000058297 220KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED
73 7000018777 870 Spares for 220kV GIS 1000058301 220KV GIS- 1600A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 INCLUDED
74 7000018777 880 Spares for 220kV GIS 1000049497 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-220kV GIS SET 1 INCLUDED
75 7000018777 890 Spares for 220kV GIS 1000058284 220KV GIS-ONE POLE OF 1600A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT SET 1 INCLUDED
76 7000018777 900 Spares for 220kV GIS 1000021871 Trip coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED
77 7000018777 910 Spares for 220kV GIS 1000009185 Closing coil assembly with resistor for245kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED
78 7000018777 920 Spares for 220kV GIS 1000058292 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 220KV GIS CIRCUIT BREAKER SET 1 INCLUDED
79 7000018777 930 Spares for 220kV GIS 1000007066 Auxiliary switch assembly of each type for 245kV GIS Circuit Breaker SET 1 INCLUDED
80 7000018777 940 Spares for 220kV GIS 1000058291 220KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 1 INCLUDED
81 7000018777 950 Spares for 220kV GIS 1000058288 220KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
82 7000018777 960 Spares for 220kV GIS 1000049758 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
83 7000018777 970 Spares for 220kV GIS 1000058272 220KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
84 7000018777 980 Spares for 220kV GIS 1000058290 220KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 INCLUDED
85 7000018777 990 Spares for 220kV GIS 1000049834 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
86 7000018777 1000 Spares for 220kV GIS 1000049794 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
87 7000018777 1010 Spares for 220kV GIS 1000049807 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
88 7000018777 1020 Spares for 220kV GIS 1000049804 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
89 7000018777 1030 Spares for 220kV GIS 1000058289 220KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
90 7000018777 1040 Spares for 220kV GIS 1000049798 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
91 7000018777 1050 Spares for 220kV GIS 1000058293 220KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 INCLUDED
92 7000018777 1060 Spares for 220kV GIS 1000058287 220KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
93 7000018777 1070 Spares for 220kV GIS 1000049797 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC-SPRING OPERATEDMECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREAKER SET 1 INCLUDED
94 7000018777 1080 Spares for 220kV GIS 1000049801 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER SET 1 INCLUDED
95 7000018777 1090 Spares for 220kV GIS 1000058371 220kV GIS- Three phase of 1600Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 INCLUDED
96 7000018777 1100 Spares for 220kV GIS 1000058282 220KV GIS- THREE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED
97 7000018777 1110 Spares for 220kV GIS 1000058278 220KV GIS - THREE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED
98 7000018777 1120 Spares for 220kV GIS 1000058273 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS DISCONNECTORSWITCH SET 1 INCLUDED
99 7000018777 1130 Spares for 220kV GIS 1000058280 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS MAINTENANCE EARTHSWITCH SET 1 INCLUDED
100 7000018777 1140 Spares for 220kV GIS 1000058276 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS FAST EARTHINGSWITCH SET 1 INCLUDED
101 7000018777 1150 Spares for 220kV GIS 1000049773 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-220KV GIS SET 1 INCLUDED
102 7000018777 1160 Spares for 220kV GIS 1000049775 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-220KV GIS SET 1 INCLUDED
103 7000018777 1170 Spares for 220kV GIS 1000049774 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-220KV GIS SET 1 INCLUDED
104 7000018777 1180 Spares for 220kV GIS 1000058274 DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH SET 1 INCLUDED
105 7000018777 1190 Spares for 220kV GIS 1000058281 DRIVE MECHANISM FOR 220KV GIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED
106 7000018777 1200 Spares for 220kV GIS 1000058277 DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH SET 1 INCLUDED
107 7000018777 1210 Spares for 220kV GIS 1000058275 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH EA 1 INCLUDED
108 7000018777 1220 Spares for 220kV GIS 1000058283 MOTOR FOR DRIVE MECHANISM FOR 220KVGIS MAINTENANCE EARTH SWITCH EA 1 INCLUDED
109 7000018777 1230 Spares for 220kV GIS 1000058279 MOTOR FOR DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH EA 1 INCLUDED
110 7000018777 1240 Spares for 220kV GIS 1000058294 220KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (4 CORES) WITHASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALL RESPECT EA 1 INCLUDED
111 7000018777 1250 Spares for 220kV GIS 1000058296 220KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT EA 1 INCLUDED
112 7000018777 1260 Spares for 220kV GIS 1000058303 220KV GIS- SINGLE PHASE GAS INSULATED SURGE ARRESTER WITH ASSOCIATEDENCLOSURE AND INSULATOR COMPLETE IN ALL RESPECT EA 1 INCLUDED
113 7000018777 1270 Spares for 220kV GIS 1000058304 220KV GIS- SURGE COUNTER/ MONITOR EA 1 INCLUDED
114 7000018777 1280 Telecom Eqpt for New Melli 1000028251 Base Equipment STM-4 MADM upto 5 MSP SET 1 INCLUDED
115 7000018777 1290 Telecom Eqpt for New Melli 1000023721 SFP S4.1 EA 6 INCLUDED
116 7000018777 1300 Telecom Eqpt for New Melli 1000023719 SFP L4.1 EA 2 INCLUDED
117 7000018777 1310 Telecom Eqpt for New Melli 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED
118 7000018777 1320 Telecom Eqpt for New Melli 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED
119 7000018777 1330 Telecom Eqpt for New Melli 1000026228 Equipment Cabinets For SDH EA 1 INCLUDED
120 7000018777 1340 Telecom Eqpt for New Melli 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED
121 7000018777 1360 Telecom Spare at New Melli 1000023721 SFP S4.1 EA 1 INCLUDED
122 7000018777 1370 Telecom Spare at New Melli 1000023719 SFP L4.1 EA 1 INCLUDED
123 7000018777 1380 Telecom Equipment at Rangit(NHPC) 1000028251 Base Equipment STM-4 MADM upto 5 MSP SET 1 INCLUDED
124 7000018777 1390 Telecom Equipment at Rangit(NHPC) 1000023721 SFP S4.1 EA 2 INCLUDED
125 7000018777 1400 Telecom Equipment at Rangit(NHPC) 1000023719 SFP L4.1 EA 2 INCLUDED
126 7000018777 1410 Telecom Equipment at Rangit(NHPC) 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED
127 7000018777 1420 Telecom Equipment at Rangit(NHPC) 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED
128 7000018777 1430 Telecom Equipment at Rangit(NHPC) 1000026228 Equipment Cabinets For SDH EA 1 INCLUDED
129 7000018777 1440 Telecom Equipment at Rangit(NHPC) 1000028495 NMS- CRAFT TERMINAL-HARDWARE EA 1 INCLUDED
130 7000018777 1450 Telecom Equipment at Rangit(NHPC) 1000028265 Software for Craft Terminal EA 1 INCLUDED
131 7000018777 1460 Telecom Equipment at Rangit(NHPC) 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED
132 7000018777 1480 Telecom Spares at Rangit(NHPC) 1000031371 SDH EQUIPMENT (STM-4 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 INCLUDED
133 7000018777 1490 Telecom Spares at Rangit(NHPC) 1000023721 SFP S4.1 EA 1 INCLUDED
134 7000018777 1500 Telecom Spares at Rangit(NHPC) 1000023719 SFP L4.1 EA 1 INCLUDED
135 7000018777 1510 Telecom Spares at Rangit(NHPC) 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 INCLUDED
136 7000018777 1520 Telecom Spares at Rangit(NHPC) 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 INCLUDED
137 7000018777 1530 Telecom Spares at Rangit(NHPC) 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 INCLUDED
138 7000018777 1540 Telecom Spares at Rangit(NHPC) 1000031398 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 INCLUDED
TOTAL FOR Local Transportation, In-transit Insurance, Loading and Unloading 0.00
Date Printed Name
Place Designation
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 3
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Installation Charges : (All Prices are in Indian Rupees)
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘8’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable ( in %) Whether rate of GST in column ‘10’ is confirmed. If not indicate applicable rate of GST # Description Unit Quantity Unit Erection Charges Total Erection Charges GST Before Discount Discount Total Price after discount GST After Discount
A 220KV RANGIT IV-NEW MELLI TL
2 7000018805 260 100 20 SURVEY 100002672 998344 18 Detailed Survey including profiling & tower spotting KM 3.85 INCLUDED 0 0 0.0000000000 0 0 0.00
4 7000018805 270 110 10 SOIL INVESTIGATION 100001245 998342 18 Detailed soil investigation: Fissured Rock EA 10 INCLUDED 0 0 0.0000000000 0 0 0.00
5 7000018805 270 110 20 SOIL INVESTIGATION 100001246 998342 18 Detailed soil investigation: Hard Rock EA 4 INCLUDED 0 0 0.0000000000 0 0 0.00
6 7000018805 310 120 10 WORK ASSOCIATED WITH TOWER FOUNDATION 100001257 995433 18 Excavation: Dry Fissured Rock M3 2576 INCLUDED 0 0 0.0000000000 0 0 0.00
7 7000018805 310 120 20 WORK ASSOCIATED WITH TOWER FOUNDATION 100001258 995433 18 Excavation: Wet Fissured Rock M3 1267 INCLUDED 0 0 0.0000000000 0 0 0.00
8 7000018805 310 120 30 WORK ASSOCIATED WITH TOWER FOUNDATION 100001259 995433 18 Excavation: Hard Rock M3 76 INCLUDED 0 0 0.0000000000 0 0 0.00
9 7000018805 310 120 40 WORK ASSOCIATED WITH TOWER FOUNDATION 100001260 995454 18 Concreting (including all associated works related to foundation not covered in excavation and reinforcemt steel works : concreting(1:1.5:3) M3 709 INCLUDED 0 0 0.0000000000 0 0 0.00
10 7000018805 310 120 50 WORK ASSOCIATED WITH TOWER FOUNDATION 100001261 995454 18 Concreting (including all associated works related to foundation not covered in excavation and reinforcemt steel works : LeanConcrete (1:3:6) M3 74 INCLUDED 0 0 0.0000000000 0 0 0.00
11 7000018805 310 120 60 WORK ASSOCIATED WITH TOWER FOUNDATION 100001262 995454 18 Reinforcement Steel : Supply and placement MT 65 INCLUDED 0 0 0.0000000000 0 0 0.00
12 7000018805 310 120 70 WORK ASSOCIATED WITH TOWER FOUNDATION 100001263 995455 18 Installation of stub including bolts and nuts : For Normal Towers MT 14 INCLUDED 0 0 0.0000000000 0 0 0.00
13 7000018805 320 130 10 ERECTION 100001248 995455 18 Erection of various types of towers, tower extensions (complete), bolts & nuts, hangers, d-shackles, step bolts, pack washers etc.including tack welding & supply & application of zinc rich paint : Normal towers MT 333 INCLUDED 0 0 0.0000000000 0 0 0.00
14 7000018805 280 150 10 INSTALLATION OF EARTHING OF TOWERS 100001270 995468 18 Installation of earthing of towers: Counterpoise type (120 m length) EA 7 INCLUDED 0 0 0.0000000000 0 0 0.00
15 7000018805 280 150 20 INSTALLATION OF EARTHING OF TOWERS 100008105 995468 18 Installation of Chemical earthing of towers: Counterpoise Type (120m length). EA 5 INCLUDED 0 0 0.0000000000 0 0 0.00
16 7000018805 280 150 30 INSTALLATION OF EARTHING OF TOWERS 100002203 995468 18 Installation of Shieldwire Earthingincluding PG clamps, Downlead clampsand Earthwire bits i.e Shield wireearthing (Pipe Type/counterpoise type)shall be an addition to earthing oftowers (Pipe type/counterpoisetype)-Counterpoise type EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
17 7000018805 280 150 40 INSTALLATION OF EARTHING OF TOWERS 100001272 995468 18 Installation of earthing of towers: Counterpoise type (280 m length)* EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
18 7000018805 290 160 10 INSTALLATION OF TOWER ACCESSORIES 100001274 995444 18 Installation of tower accessories : Danger Plate EA 14 INCLUDED 0 0 0.0000000000 0 0 0.00
19 7000018805 290 160 20 INSTALLATION OF TOWER ACCESSORIES 100001275 995444 18 Installation of tower accessories: Number Plate EA 14 INCLUDED 0 0 0.0000000000 0 0 0.00
20 7000018805 290 160 30 INSTALLATION OF TOWER ACCESSORIES 100001276 995444 18 Installation of tower accessories: Phase Plate (Set of three) SET 28 INCLUDED 0 0 0.0000000000 0 0 0.00
21 7000018805 290 160 40 INSTALLATION OF TOWER ACCESSORIES 100001278 995444 18 Installation of tower accessories: Circuit Plate (Set of two) SET 14 INCLUDED 0 0 0.0000000000 0 0 0.00
22 7000018805 290 160 50 INSTALLATION OF TOWER ACCESSORIES 100001277 995444 18 Installation of tower accessories: Anti-Climbing Devices EA 14 INCLUDED 0 0 0.0000000000 0 0 0.00
23 7000018805 300 180 10 STRINGING 100002302 995468 18 220kV AC Double circuit with twin conductor / installation of insulator strings complete with arcing horns and necessary hardware,installing and stringing of conductor including fixing of conductor accessories, installing and stringing of OPGW accessories forthe line. KM 3.85 INCLUDED 0 0 0.0000000000 0 0 0.00
24 7000018805 460 290 10 PROTECTION OF TOWER FOOTING 100001264 995456 18 Protection of tower footing (supply and installation): ' Random rubble stone masonary including excavation (1:5 cement mortar) M3 2421 INCLUDED 0 0 0.0000000000 0 0 0.00
25 7000018805 460 290 20 PROTECTION OF TOWER FOOTING 100001265 995456 18 Protection of tower footing (supply and installation): Stone Bound in Galvanising wire netting including excavation M3 612 INCLUDED 0 0 0.0000000000 0 0 0.00
26 7000018805 460 290 30 PROTECTION OF TOWER FOOTING 100001268 995456 18 Protection of tower footing (supply and installation): Backfilling and gap levelling of volumes enclosed by revetment M3 300 INCLUDED 0 0 0.0000000000 0 0 0.00
27 7000018805 460 290 40 PROTECTION OF TOWER FOOTING 100001267 995456 18 Protection of tower footing (supply and installation): M 15 (1:2:4) mixed concrete for top seal cover of revetment M3 18 INCLUDED 0 0 0.0000000000 0 0 0.00
28 7000018805 460 290 50 PROTECTION OF TOWER FOOTING 100004392 995454 18 Plum concrete with 50% hard stone of grade 1:2:4 (stone size not more than 150mm) M3 500 INCLUDED 0 0 0.0000000000 0 0 0.00
29 7000018805 470 300 10 BENCHING 100001252 995432 18 Benching: All kinds of soils except fissured rock,hard rock and sandy soil M3 2317 INCLUDED 0 0 0.0000000000 0 0 0.00
30 7000018805 470 300 20 BENCHING 100001253 995432 18 Benching: Fissured Rock M3 4245 INCLUDED 0 0 0.0000000000 0 0 0.00
32 7000018805 670 330 10 Installation of OPGW 170000265 998716 18 Installation of Joint box above ground (Including Splicing & Testing) : 24 fibres EA 3 INCLUDED 0 0 0.0000000000 0 0 0.00
33 7000018805 670 330 20 Installation of OPGW 170000356 998336 18 Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19" rack or slimline rack: Type 2 (96 Fibre) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
34 7000018805 670 330 30 Installation of OPGW 100002882 998336 18 Fibre Optic Approach cabling: Including installation hardware like ties/clips/cleats, conduits, ducts, supports, fittings,accessories etc.: 24 Fibre KM 1 INCLUDED 0 0 0.0000000000 0 0 0.00
35 7000018805 680 340 10 PILE FOUNDATION 100024536 995451 18 Boring, providing and installation of bored Cast-in-situ RCC vertical piles of specified diameter and of any length below the pilecap with M25 grade of cement concrete, excluding the cost of reinforcement steel but including the cost of boring with temporaryGuide casing, bentonite solution and the length of pile to be embeded in the pile cap (length of pile for payment shall be measuredfrom bottom of pile cap), all necessary labour, materials, plants, tools & tackles etc., complete, as necessary for proper executionof the job. (Boring in all types of rocks excluded). : 1200mm diameter R.C.C.vertical bored pile upto 40 m from bottom of pile cap.. M 208 INCLUDED 0 0 0.0000000000 0 0 0.00
36 7000018805 680 340 20 PILE FOUNDATION 100024549 995451 18 Extra rate over item (1200mm diameter R.C.C.vertical bored pile upto 40 m from bottom of pile cap.) for boring including socketing,anchoring (if required) with required size,nos. & depth of Reinforcement in all types of rocks other than hard rock upto any depthtill founding level M 32 INCLUDED 0 0 0.0000000000 0 0 0.00
37 7000018805 680 340 30 PILE FOUNDATION 100024563 995451 18 Extra rate over item (1200mm diameter R.C.C.vertical bored pile upto 40 m from bottom of pile cap.) for boring including socketing,anchoring (if required) with required size,nos. & depth of Reinforcement in hard rock upto a maximum depth of 10m M 16 INCLUDED 0 0 0.0000000000 0 0 0.00
38 7000018805 680 340 40 PILE FOUNDATION 100001314 995451 18 Excavation where ever required for pile cap /tie etc. (other than boring) for all depth and size, in all types of soils includingdisposal of excavated materials for all lifts and leads,decent etc.as directed by Engineer - In -charge, together with all labour,tools & tackles, sheeting, sheet piling, dewatering etc. complete as required for proper execution of the job. M3 6.9 INCLUDED 0 0 0.0000000000 0 0 0.00
39 7000018805 680 340 50 PILE FOUNDATION 100001315 995451 18 Back filling with available excavatedearth for all leads and lifts in sidesof foundations and other under groundfacilities in horizontal layers notexceeding 20 cm. in depth consolidatingeach deposited layer by ramming andwatering etc. as per specification andinstruction of Engineer -in-charge. M3 10 INCLUDED 0 0 0.0000000000 0 0 0.00
40 7000018805 680 340 60 PILE FOUNDATION 100001316 995451 18 Form work for placing plain or reinforced cement concrete of any type including blockout and section at any elevationshoring,shuttering,strutting,propping, scaffolding,tieing,nailing,including all labour, materials, equipments, waste for form,caulking,dismantling & removal of forms etc. complete. M2 102 INCLUDED 0 0 0.0000000000 0 0 0.00
41 7000018805 680 340 70 PILE FOUNDATION 100001317 995451 18 Supply and placing of steelreinforcement of specified grade forR.C.C. work in pile, pile cap, pedestal/chimney, tie beam (if required)including cost of all labours ,materials, straightening, cleaning,cutting, bending, binding etc. allcomplete as per construction drawingand as per instruction ofEngineer-In-Charge. MT 18 INCLUDED 0 0 0.0000000000 0 0 0.00
42 7000018805 680 340 80 PILE FOUNDATION 100001318 995451 18 Providing and laying in position M25Grade reinforced cement concrete forpile caps, pedestal/chimney and tiebeam(if required), excludingreinforcement steel and form work butincluding cement, all necessary toolsand tackles,labour, materials,equipments for handling,transportation,batching, mixing,placing, vibrating,dewatering, curing etc.all complete asper specification and as perinstruction of Engineer-In- Charge(excluding cost of concrete in pileswhich is included in boring of cast insitu RCC vertical piles in therelevent line item. ) M3 100 INCLUDED 0 0 0.0000000000 0 0 0.00
43 7000018805 680 340 90 PILE FOUNDATION 100001319 995451 18 Providing and laying plain cementconcrete 1:4:8 (1cement : 4 coarsesand: 8 graded stone aggregate 40mmnominal size) including cement, allnecessary tools and tackles,labour,materials, equipments forhandling,transportation,mixing,placing,vibrating,dewatering etc.all completeas per Specification . M3 6.5 INCLUDED 0 0 0.0000000000 0 0 0.00
44 7000018805 680 340 100 PILE FOUNDATION 100001320 998346 18 Conducting Standard Penetration Test (SPT) at various elevations in pile bore holes in all kind of soils including all labour,materials, tools and tackles, equipments etc. required for successful completion of the job. EA 32 INCLUDED 0 0 0.0000000000 0 0 0.00
45 7000018805 680 340 110 PILE FOUNDATION 100001321 995451 18 Supply and Providing M.S. liner of 6mm. thick in piles upto 10m. Depth (maxm.) from bottom of pile cap, limited to the approveddrawing, including supply, straightening, bending, welding,all supports, labours, tools and tackles, plants & equipments, withprimer and paintinting etc. (complete) as required for successful completion of the job MT 15 INCLUDED 0 0 0.0000000000 0 0 0.00
46 7000018805 680 340 120 PILE FOUNDATION 100001322 998346 18 Conducting integrity test on pile usingelectronic control unit,hand heldhammer, accelerometer, computer withrequired software to assessas-installed pile characteresticsincluding mobilisation of necessarymanpower, equipments, materials etc.required for successful completion ofthe job EA 16 INCLUDED 0 0 0.0000000000 0 0 0.00
47 7000018785 10 350 10 Labour Camp 100023085 995455 18 ESTABLISHMENT OF LABOUR CAMPS AS PER PROVISION UNDER FACILITIES TO BE INCORPORATED FOR LABOURERS IN TECHNICAL SPECIFICATION LS 1 INCLUDED 0 0 0.0000000000 0 0 0.00
B 220 KV New Melli (PG) GIS S/s extn
1 7000018777 610 1260 20 220kV, 40kA GIS Equipment 100000428 998736 18 220KV, 1600 Amps, Single phase GIS bus duct M 350 INCLUDED 0 0 0.0000000000 0 0 0.00
2 7000018777 610 1260 30 220kV, 40kA GIS Equipment 100003589 998736 18 245kV, 1600A, 40kA Single phase SF6 to Air Bushing SET 6 INCLUDED 0 0 0.0000000000 0 0 0.00
3 7000018777 610 1260 40 220kV, 40kA GIS Equipment 100000382 998736 18 245kV, 1600 A, 40 kA, SF6 GIS Line feeder bay module as per Section-Project, Technical specification SET 2 INCLUDED 0 0 0.0000000000 0 0 0.00
4 7000018777 610 1260 50 220kV, 40kA GIS Equipment 100003583 998736 18 245 kV, 3000 A, 40 kA, SF6 GIS Bus bar module Extension as per Section-Project, Technical specification SET 2 INCLUDED 0 0 0.0000000000 0 0 0.00
5 7000018777 620 1350 10 245kV, 40kA AIS EQUIPMENT 100000448 998736 18 245 kV, 4400pf Capacitive Voltage Transformer (1- Phase) EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
6 7000018777 620 1350 20 245kV, 40kA AIS EQUIPMENT 100000484 998736 18 216kV Surge Arrester (1-phase) EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
7 7000018777 620 1350 30 245kV, 40kA AIS EQUIPMENT 100001907 998736 18 245 kV,1 phase Bus Post Insulator (except for Line Traps) EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
8 7000018777 620 1350 40 245kV, 40kA AIS EQUIPMENT 100000884 998734 18 245 kV ,1 phase Bus Post Insulators for Line Traps EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
9 7000018777 630 1431 10 Erection Hardware for 220 kV GIS 100000512 998731 18 Erection Hardware for 220kV DM-type layout for GIS termination arrangement-Line bay as per specification SET 2 INCLUDED 0 0 0.0000000000 0 0 0.00
10 7000018777 640 1451 10 Earthmat 100003103 998731 18 40 mm MS rod for Main Earthmat KM 1 INCLUDED 0 0 0.0000000000 0 0 0.00
11 7000018777 650 1490 10 CRP for 220kV Bays with SAS at New Melli 100000743 998736 18 Augmentation of existing 220kV bus bar protection scheme.(No. of bays as per specification)-(with Automation) SET 1 INCLUDED 0 0 0.0000000000 0 0 0.00
12 7000018777 650 1490 20 CRP for 220kV Bays with SAS at New Melli 100000738 998736 18 220kV Line Protection Panel (with Automation) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
13 7000018777 650 1490 30 CRP for 220kV Bays with SAS at New Melli 100000736 998736 18 220kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
14 7000018777 660 1513 10 SAS-AUG 100002070 998736 18 Augmentation of Substation automation System for 220kV bay as per Technical Specification EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
15 7000018777 670 1530 10 PLCC Equipment at New Melli 100000878 998734 18 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
16 7000018777 670 1530 20 PLCC Equipment at New Melli 100000886 998734 18 Coupling device for PLCC EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
17 7000018777 670 1530 30 PLCC Equipment at New Melli 100000888 998734 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
18 7000018777 670 1530 40 PLCC Equipment at New Melli 100000890 998734 18 Protection Coupler (Analog) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
19 7000018777 670 1530 50 PLCC Equipment at New Melli 100000891 998734 18 Digital Protection Coupler EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
20 7000018777 670 1530 60 PLCC Equipment at New Melli 100002762 998734 18 PLCC-Equipments-Telephone Instruments (2 wire) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
21 7000018777 670 1530 70 PLCC Equipment at New Melli 100003517 998734 18 HF CABLE FOR PLCC-75 OHM (KM) KM 1 INCLUDED 0 0 0.0000000000 0 0 0.00
22 7000018777 680 1531 10 PLCC Equipment at Rangit(NHPC) 100003517 998734 18 HF CABLE FOR PLCC-75 OHM (KM) KM 1 INCLUDED 0 0 0.0000000000 0 0 0.00
23 7000018777 680 1531 20 PLCC Equipment at Rangit(NHPC) 100002762 998734 18 PLCC-Equipments-Telephone Instruments (2 wire) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
24 7000018777 680 1531 30 PLCC Equipment at Rangit(NHPC) 100000891 998734 18 Digital Protection Coupler EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
25 7000018777 680 1531 40 PLCC Equipment at Rangit(NHPC) 100000890 998734 18 Protection Coupler (Analog) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
26 7000018777 680 1531 50 PLCC Equipment at Rangit(NHPC) 100000888 998734 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
27 7000018777 680 1531 60 PLCC Equipment at Rangit(NHPC) 100000886 998734 18 Coupling device for PLCC EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
28 7000018777 680 1531 70 PLCC Equipment at Rangit(NHPC) 100000878 998734 18 220kV, 1600A, 0.5mH, 40 kA Line Trap EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
32 7000018777 700 1591 10 POWER & CONTROL CABLE 100002930 998736 18 1.1kV grade 19Cx2.5 sqmm Control Cable KM 0.8 INCLUDED 0 0 0.0000000000 0 0 0.00
33 7000018777 700 1591 20 POWER & CONTROL CABLE 100002927 998736 18 1.1kV grade 14Cx2.5 sqmm Control Cable KM 0.4 INCLUDED 0 0 0.0000000000 0 0 0.00
34 7000018777 700 1591 40 POWER & CONTROL CABLE 100002920 998736 18 1.1kV grade 10Cx2.5 sqmm Control Cable KM 0.5 INCLUDED 0 0 0.0000000000 0 0 0.00
35 7000018777 700 1591 50 POWER & CONTROL CABLE 100003000 998736 18 1.1kV grade 7Cx2.5 sqmm Control Cable KM 0.2 INCLUDED 0 0 0.0000000000 0 0 0.00
36 7000018777 700 1591 60 POWER & CONTROL CABLE 100002994 998736 18 1.1kV grade 5Cx2.5 sqmm Control Cable KM 1.5 INCLUDED 0 0 0.0000000000 0 0 0.00
37 7000018777 700 1591 70 POWER & CONTROL CABLE 100002977 998736 18 1.1kV grade 3Cx2.5 sqmm Control Cable KM 0.4 INCLUDED 0 0 0.0000000000 0 0 0.00
38 7000018777 700 1591 80 POWER & CONTROL CABLE 100002958 998736 18 1.1kV grade 2Cx6 sqmm (PVC) Power Cable KM 0.2 INCLUDED 0 0 0.0000000000 0 0 0.00
39 7000018777 700 1591 90 POWER & CONTROL CABLE 100002992 998736 18 1.1kV grade 4Cx6 sqmm (PVC) Power Cable KM 0.8 INCLUDED 0 0 0.0000000000 0 0 0.00
40 7000018777 710 1620 10 ILLUMINATION SYSTEM 100001021 995461 18 Lighting Panel type ACP-2 as per technical specification EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
41 7000018777 710 1620 20 ILLUMINATION SYSTEM 100001024 998731 18 Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
42 7000018777 710 1620 30 ILLUMINATION SYSTEM 100001052 998731 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) as per technical specifications EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
43 7000018777 710 1620 40 ILLUMINATION SYSTEM 100004852 998731 18 Lighting Fixture LED Luminaires type FL-1 as per tech. specifications EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
44 7000018777 710 1620 50 ILLUMINATION SYSTEM 100004926 998731 18 Lighting Fixture LED Luminaires type FL2 as per tech. specifications EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
45 7000018777 740 1670 10 Civil Works 100004518 995433 18 Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 1962 INCLUDED 0 0 0.0000000000 0 0 0.00
46 7000018777 740 1670 20 Civil Works 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 134 INCLUDED 0 0 0.0000000000 0 0 0.00
47 7000018777 740 1670 30 Civil Works 100001326 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 5 INCLUDED 0 0 0.0000000000 0 0 0.00
48 7000018777 740 1670 40 Civil Works 100001328 995454 18 Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) M3 23 INCLUDED 0 0 0.0000000000 0 0 0.00
49 7000018777 740 1670 50 Civil Works 100001754 995454 18 Providing and laying of Reinforced Cement Concrete 1:1.5:3 including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 500 INCLUDED 0 0 0.0000000000 0 0 0.00
50 7000018777 740 1670 60 Civil Works 100001329 995454 18 Steel Reinforcement MT 35 INCLUDED 0 0 0.0000000000 0 0 0.00
51 7000018777 740 1670 70 Civil Works 100001331 995455 18 Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 9 INCLUDED 0 0 0.0000000000 0 0 0.00
52 7000018777 740 1670 80 Civil Works 100001714 995428 18 Stone spreading in switchyard excluding PCC M2 300 INCLUDED 0 0 0.0000000000 0 0 0.00
53 7000018777 740 1670 90 Civil Works 100001713 995424 18 Antiweed treatment M2 300 INCLUDED 0 0 0.0000000000 0 0 0.00
54 7000018777 740 1670 100 Civil Works 100001736 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as perspecification. M 20 INCLUDED 0 0 0.0000000000 0 0 0.00
55 7000018777 740 1670 110 Civil Works 100001735 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as perspecification. M 20 INCLUDED 0 0 0.0000000000 0 0 0.00
56 7000018777 740 1670 120 Civil Works 100001412 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section A-A M 150 INCLUDED 0 0 0.0000000000 0 0 0.00
57 7000018777 740 1670 130 Civil Works 100001413 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section B-B M 50 INCLUDED 0 0 0.0000000000 0 0 0.00
58 7000018777 740 1670 160 Civil Works 100004507 995421 18 3.75m wide Cement Concrete road with PCC shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS.However, reinforcement steel and all type concrete shall be paid separately under relevant items M2 375 INCLUDED 0 0 0.0000000000 0 0 0.00
59 7000018777 740 1670 170 Civil Works 100001737 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as perspecification. M 20 INCLUDED 0 0 0.0000000000 0 0 0.00
60 7000018777 740 1670 180 Civil Works 100004463 995456 18 Random Rubble masonry for Retaining wall with locally available stone in cement sand mortar 1:6 (1 Cement: 6 coarse sand) includinglevelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size), Raised and Cutpointing on exposed surface, weep holes/PVC pipe sleeves of 100 mm dia (medium class) @ 1 metre C/C staggered . The top of theretaining wall to be provided with cement concrete 1:2:4. However items of excavation, concrete (1:2:4) shall be payable underrespective items of BPS M3 100 INCLUDED 0 0 0.0000000000 0 0 0.00
61 7000018777 740 1670 190 Civil Works 100003295 995429 18 Dismantling of RCC in foundation including disposal of debris and reinforcement bars of dismantled RCC works within substationboundaries as per direction of enginner incahrge M3 20 INCLUDED 0 0 0.0000000000 0 0 0.00
62 7000018777 720 1680 10 220kV Equipment support structures 100001225 995455 18 Erection of Pipe Structure - 220 kV 1-Phase BPI including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
63 7000018777 720 1680 20 220kV Equipment support structures 100001221 995455 18 Erection of Pipe Structure - 220 kV 1-Phase CVT including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
64 7000018777 720 1680 30 220kV Equipment support structures 100001224 995455 18 Erection of Pipe Structure - 220 kV 1-Phase SA including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
65 7000018777 720 1680 40 220kV Equipment support structures 100003521 995455 18 Erection of Pipe Structure - 220 kV 1 - PH BPI for WT including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts SET 12 INCLUDED 0 0 0.0000000000 0 0 0.00
66 7000018777 720 1680 50 220kV Equipment support structures 100001674 995455 18 Erection of 28mm dia foundation bolts including nuts, checknuts, washers and packplates. EA 108 INCLUDED 0 0 0.0000000000 0 0 0.00
67 7000018777 730 1690 10 220 KV TOWERS 100001210 995455 18 Erection of Lattice Structures (MS Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts MT 39 INCLUDED 0 0 0.0000000000 0 0 0.00
68 7000018777 730 1690 20 220 KV TOWERS 100001681 995455 18 Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 6.5 INCLUDED 0 0 0.0000000000 0 0 0.00
69 7000018777 730 1690 30 220 KV TOWERS 100001680 995455 18 Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 2.4 INCLUDED 0 0 0.0000000000 0 0 0.00
70 7000018777 1350 20 30 Telecom Service at New Melli 170000643 998336 18 Installation of STM-4 ADM Base Equipment EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
71 7000018777 1350 20 40 Telecom Service at New Melli 170000427 998734 18 Optical Interface Cards/SFP# -S4.1 SDH Equipment -STM-4 EA 6 INCLUDED 0 0 0.0000000000 0 0 0.00
72 7000018777 1350 20 50 Telecom Service at New Melli 170000428 998734 18 Optical Interface Cards/SFP# -L4.1 for SDH Equipment-STM-4 EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
73 7000018777 1350 20 60 Telecom Service at New Melli 100002825 998734 18 Tributary interface- E1 interface (Minimum 16 nos.) SET 2 INCLUDED 0 0 0.0000000000 0 0 0.00
74 7000018777 1350 20 70 Telecom Service at New Melli 170000550 998336 18 Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
75 7000018777 1350 20 80 Telecom Service at New Melli 170000375 998734 18 Equipment Cabinets-For SDH Equipments EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
76 7000018777 1350 20 110 Telecom Service at New Melli 170000551 998336 18 VOIP telephone instrument with one common switch (min. 8 port) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
77 7000018777 1470 50 10 Telecom Service at Rangit(NHPC) 170000154 998336 18 STM-4 ADM Base Equipment (Common cards, Power supply cards, patch cords, power cabling, tributary cables, other hardware &accessories including sub-racks etc. ) EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
78 7000018777 1470 50 20 Telecom Service at Rangit(NHPC) 170000427 998734 18 Optical Interface Cards/SFP# -S4.1 SDH Equipment -STM-4 EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
79 7000018777 1470 50 30 Telecom Service at Rangit(NHPC) 170000428 998734 18 Optical Interface Cards/SFP# -L4.1 for SDH Equipment-STM-4 EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
80 7000018777 1470 50 40 Telecom Service at Rangit(NHPC) 100002825 998734 18 Tributary interface- E1 interface (Minimum 16 nos.) SET 2 INCLUDED 0 0 0.0000000000 0 0 0.00
81 7000018777 1470 50 50 Telecom Service at Rangit(NHPC) 170000550 998336 18 Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
82 7000018777 1470 50 60 Telecom Service at Rangit(NHPC) 170000375 998734 18 Equipment Cabinets-For SDH Equipments EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
83 7000018777 1470 50 70 Telecom Service at Rangit(NHPC) 170000376 998734 18 NMS-Craft Terminal-Hardware EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
84 7000018777 1470 50 80 Telecom Service at Rangit(NHPC) 170000377 998734 18 NMS-Craft Terminal-Software EA 1 INCLUDED 0 0 0.0000000000 0 0 0.00
85 7000018777 1470 50 90 Telecom Service at Rangit(NHPC) 170000551 998336 18 VOIP telephone instrument with one common switch (min. 8 port) EA 2 INCLUDED 0 0 0.0000000000 0 0 0.00
Total of Schedule-3 0.00 0.00 0.00 0.00
# In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date Printed Name
Place Designation
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 4
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Training Charges :
SI. No. PR No Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘…’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable ( in %) Whether rate of GST in column ‘---’ is confirmed. If not indicate applicable rate of GST # Description Unit Quantity Unit Charges Total Charges
Place Printed Name
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 5
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SUMMARY OF TAXES & DUTIES not included in Schedule 1 & 3)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST on Goods 0.00 Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00 Sales Tax 0.00 Sales Tax 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 5
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST on Goods 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 6
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+5]
Date : Printed Name :
Place : Designation :
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 6 After Discount
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2
Local Transportation, Insurance and other Incidental Services
3 TOTAL SCHEDULE NO. 3
Installation Charges
4 TOTAL SCHEDULE NO. 4
Training Charges
5 TOTAL SCHEDULE NO. 5
Taxes and Duties
6 TOTAL SCHEDULE NO. 7
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5]
Date : Printed Name :
Place : Designation :
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule - 6
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR) From Sch-6 Discount Factors
1 TOTAL SCHEDULE NO. 1 0.00 0.00 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00 0.00 0.00
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00 0.00 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+5]
Date : Printed Name :
Place : Designation :
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Schedule 7
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
Bidder’s Name and Address (Sole Bidder) : To:
Name : Contract Services
Address : Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
SL. NO. PR No Line Item No Code HSN of the Equipment /item for which type test is to be conducted Whether HSN in column ‘---’ is confirmed. If not indicate applicable the HSN code # Rate of GST applicable ( in %) Whether rate of GST in column ‘---’ is confirmed. If not indicate applicable rate of GST # Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
Date Printed Name
Place Designation
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5
Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
SL. NO. Description of Test #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
This letter of discount is optional. Bidder may / may not offer any discount.
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Letter of Discount
LETTER OF DISCOUNT
Contract Services Schedule 1 0.00
Power Grid Corporation of India Ltd., Schedule 2 0.00
"Saudamini", Plot No.-2 Schedule 3 0.00
Sector-29, (near IFFCO Chowk) Total 0.00
Gurgaon (Haryana) - 122001
Subject : Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL.
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Sch-1 Sch-2 Sch-3
1 Discount on lum-sum basis on total price quoted by us without GST. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2, Sch-3, Sch-4 & Sch-7] In Rs. 0.00 0.00 0.00
2 Discount on percent basis on total price quoted by us without GST. [The discount shall be applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 , Sch-3, Sch-4 & Sch-7] In Percent (%) 0.00 0.00 0.00
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Rs. 0.00
Schedule-3 : Installation Charges In Rs. 0.00
Schedule-4 : Training Charges In Rs.
Schedule-7 : Type Test Charges In Rs.
4 Discount on percent basis on the Schedules as given below : [The discount shall be applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Percent (%) 0.00
Schedule-3 : Installation Charges In Percent (%) 0.00
Schedule-4 : Training Charges In Percent (%)
Schedule-7 : Type Test Charges In Percent (%)
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation. #DIV/0! #DIV/0! #DIV/0! #DIV/0! #REF!
[Discount will not be calculated autometically. However, the same shall be considered during evaluation.]
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain, 0.00 0.00 0.00
Yours faithfully, 0.00000000 0.00000000 0.00000000 Discount Factors
For and on behalf of
Date : Printed Name : 0.00
Place : Designation : 0.00
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
5002002309/CONSULTANCY GIVEN/DOM/A04-CC CS -5 Bid Form 2nd Envelope Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
0 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
"Saudamini", Plot No.-2 11 th 11 November
Sector-29, 12 th 12 December
Gurgaon (Haryana) - 122001 13 th
Name of Contract : Transmission line package TL-01 for Part – A: Construction of 220 kV D/C (Twin Moose) Transmission Line from 120 MW Rangit-IV HEP to New Melli Pooling Station and Part – B: Extension of associated 2 nos. 220 kV GIS bays at New Melli (POWERGRID) GIS S/S under Consultancy services to JPCL. 15 th
Dear Ladies and/or Gentlemen, 16 th
1.0 In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. 0/- () or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. 17 th
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 3 Installation Charges. Sole Bidder 23 th
Schedule 4 Training charges for training to be imparted (Not Applicable) 24 th
Schedule 5 Taxes and Duties not included in Schedule 1 & 3 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
Schedule 7 Break-up of Type Test Charges (Not Applicable) 27 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of test
Date : Printed Name : 0.00
Place : Designation : 0.00
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Total Ex-Works Price Direct 0.00
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF!
Total Ex-works Price including Type Test charges #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
^ If the item(s) quoted/considered as "Bought-out" in the bid are manufactured at Bidder's works and confirmed to be supplied under “Direct transaction” by the bidder, then the taxes and duties on such items shall be paid/reimbursed by POWERGRID in line with the provisions of Bidding Documents. For this purpose, at the time of award, the Ex-works price (exclusive of taxes & duties) shall be arrived at from the quoted Ex-works price (inclusive of taxes ad duties) by excluding taxes and duties applicable on such items, as on date of Bid opening, in case of supplies from manufacturer proposed in the bid. During contract execution, the taxes and duties on such items shall be paid/reimbursed at actuals, limited to the rates prevailing on date of Bid opening.
Place : Printed Name : --
Total F&I Price (=SUM(I16:I27))
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Total Installaiton Charges #REF!
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Date : (=IF('Sch-1'!B43=0,"", 'Sch-1'!B43)) (="Printed Name : " & IF('Sch-1'!E44=0,"",'Sch-1'!E44))
Place : (=IF('Sch-1'!B44=0,"", 'Sch-1'!B44)) (="Designation : " & IF('Sch-1'!E45=0,"",'Sch-1'!E45))
TOTAL TYPE TEST CHARGES (=SUM(I17:I18))
Date : (='Sch-1'!B43) (="Printed Name : " & 'Sch-1'!E44)
Place : (='Sch-1'!B44) (="Designation : " & 'Sch-1'!E45)
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
#REF! 0.00 #REF! 0.00 #REF!
#REF! #REF! #N/A
#REF! #REF! 0 #REF! #REF! 0
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 0 0 #REF! plus
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 0 1 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 1 0 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 1 1 #REF!
#REF! 0 1 0 0 #REF!
1 One 1 One 1 One 1 One #REF! 0 1 0 1 #REF!
2 Two 2 Two 2 Two 2 Two #REF! 0 1 1 0 #REF!
3 Three 3 Three 3 Three 3 Three #REF! 0 1 1 1 #REF!
4 Four 4 Four 4 Four 4 Four #REF! 1 0 0 0 #REF!
5 Five 5 Five 5 Five 5 Five #REF! 1 0 0 1 #REF!
6 Six 6 Six 6 Six 6 Six #REF! 1 0 1 0 #REF!
7 Seven 7 Seven 7 Seven 7 Seven #REF! 1 0 1 1 #REF!
8 Eight 8 Eight 8 Eight 8 Eight #REF! 1 1 0 0 #REF!
9 Nine 9 Nine 9 Nine 9 Nine #REF! 1 1 0 1 #REF!
10 Ten 10 Ten 10 Ten 10 Ten #REF! 1 1 1 0 #REF!
11 Eleven 11 Eleven 11 Eleven 11 Eleven #REF! 1 1 1 1 #REF!
12 Twelve 12 Twelve 12 Twelve 12 Twelve
13 Thirteen 13 Thirteen 13 Thirteen 13 Thirteen
14 Fourteen 14 Fourteen 14 Fourteen 14 Fourteen
15 Fifteen 15 Fifteen 15 Fifteen 15 Fifteen
16 Sixteen 16 Sixteen 16 Sixteen 16 Sixteen #REF! 0 0 0 0 #REF! +
17 Seventeen 17 Seventeen 17 Seventeen 17 Seventeen #REF! 0 0 0 1 #REF! /- +
18 Eighteen 18 Eighteen 18 Eighteen 18 Eighteen #REF! 0 0 1 0 #REF! /-
19 Nineteen 19 Nineteen 19 Nineteen 19 Nineteen #REF! 0 0 1 1 #REF!
20 Twenty 20 Twenty 20 Twenty 20 Twenty #REF! 0 1 0 0 #REF!
21 Twenty One 21 Twenty One 21 Twenty One 21 Twenty One #REF! 0 1 0 1 #REF!
22 Twenty Two 22 Twenty Two 22 Twenty Two 22 Twenty Two #REF! 0 1 1 0 #REF!
23 Twenty Three 23 Twenty Three 23 Twenty Three 23 Twenty Three #REF! 0 1 1 1 #REF!
24 Twenty Four 24 Twenty Four 24 Twenty Four 24 Twenty Four #REF! 1 0 0 0 #REF!
25 Twenty Five 25 Twenty Five 25 Twenty Five 25 Twenty Five #REF! 1 0 0 1 #REF!
26 Twenty Six 26 Twenty Six 26 Twenty Six 26 Twenty Six #REF! 1 0 1 0 #REF!
27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 27 Twenty Seven #REF! 1 0 1 1 #REF!
28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 28 Twenty Eight #REF! 1 1 0 0 #REF!
29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 29 Twenty Nine #REF! 1 1 0 1 #REF!
30 Thirty 30 Thirty 30 Thirty 30 Thirty #REF! 1 1 1 0 #REF!
31 Thirty One 31 Thirty One 31 Thirty One 31 Thirty One #REF! 1 1 1 1 #REF!
32 Thirty Two 32 Thirty Two 32 Thirty Two 32 Thirty Two
33 Thirty Three 33 Thirty Three 33 Thirty Three 33 Thirty Three
34 Thirty Four 34 Thirty Four 34 Thirty Four 34 Thirty Four
35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr
36 Thirty Six 36 Thirty Six 36 Thirty Six 36 Thirty Six
37 Thirty Seven 37 Thirty Seven 37 Thirty Seven 37 Thirty Seven
38 Thirty Eight 38 Thirty Eight 38 Thirty Eight 38 Thirty Eight
39 Thirty Nine 39 Thirty Nine 39 Thirty Nine 39 Thirty Nine
40 Forty 40 Forty 40 Forty 40 Forty
41 Forty One 41 Forty One 41 Forty One 41 Forty One
42 Forty Two 42 Forty Two 42 Forty Two 42 Forty Two
43 Forty Three 43 Forty Three 43 Forty Three 43 Forty Three
44 Forty Four 44 Forty Four 44 Forty Four 44 Forty Four
45 Forty Five 45 Forty Five 45 Forty Five 45 Forty Five
46 Forty Six 46 Forty Six 46 Forty Six 46 Forty Six
47 Forty Seven 47 Forty Seven 47 Forty Seven 47 Forty Seven
48 Forty Eight 48 Forty Eight 48 Forty Eight 48 Forty Eight
49 Forty Nine 49 Forty Nine 49 Forty Nine 49 Forty Nine
50 Fifty 50 Fifty 50 Fifty 50 Fifty
51 Fifty One 51 Fifty One 51 Fifty One 51 Fifty One
52 Fifty Two 52 Fifty Two 52 Fifty Two 52 Fifty Two
53 Fifty Three 53 Fifty Three 53 Fifty Three 53 Fifty Three
54 Fifty Four 54 Fifty Four 54 Fifty Four 54 Fifty Four
55 Fifty Five 55 Fifty Five 55 Fifty Five 55 Fifty Five
56 Fifty Six 56 Fifty Six 56 Fifty Six 56 Fifty Six
57 Fifty Seven 57 Fifty Seven 57 Fifty Seven 57 Fifty Seven
58 Fifty Eight 58 Fifty Eight 58 Fifty Eight 58 Fifty Eight
59 Fifty Nine 59 Fifty Nine 59 Fifty Nine 59 Fifty Nine
60 Sixty 60 Sixty 60 Sixty 60 Sixty
61 Sixty One 61 Sixty One 61 Sixty One 61 Sixty One
62 Sixty Two 62 Sixty Two 62 Sixty Two 62 Sixty Two
63 Sixty Three 63 Sixty Three 63 Sixty Three 63 Sixty Three
64 Sixty Four 64 Sixty Four 64 Sixty Four 64 Sixty Four
65 Sixty Five 65 Sixty Five 65 Sixty Five 65 Sixty Five
66 Sixty Six 66 Sixty Six 66 Sixty Six 66 Sixty Six
67 Sixty Seven 67 Sixty Seven 67 Sixty Seven 67 Sixty Seven
68 Sixty Eight 68 Sixty Eight 68 Sixty Eight 68 Sixty Eight
69 Sixty Nine 69 Sixty Nine 69 Sixty Nine 69 Sixty Nine
70 Seventy 70 Seventy 70 Seventy 70 Seventy
71 Seventy One 71 Seventy One 71 Seventy One 71 Seventy One
72 Seventy Two 72 Seventy Two 72 Seventy Two 72 Seventy Two
73 Seventy Three 73 Seventy Three 73 Seventy Three 73 Seventy Three
74 Seventy Four 74 Seventy Four 74 Seventy Four 74 Seventy Four
75 Seventy Five 75 Seventy Five 75 Seventy Five 75 Seventy Five
76 Seventy Six 76 Seventy Six 76 Seventy Six 76 Seventy Six
77 Seventy Seven 77 Seventy Seven 77 Seventy Seven 77 Seventy Seven
78 Seventy Eight 78 Seventy Eight 78 Seventy Eight 78 Seventy Eight
79 Seventy Nine 79 Seventy Nine 79 Seventy Nine 79 Seventy Nine
80 Eighty 80 Eighty 80 Eighty 80 Eighty
81 Eighty One 81 Eighty One 81 Eighty One 81 Eighty One
82 Eighty Two 82 Eighty Two 82 Eighty Two 82 Eighty Two
83 Eighty Three 83 Eighty Three 83 Eighty Three 83 Eighty Three
84 Eighty Four 84 Eighty Four 84 Eighty Four 84 Eighty Four
85 Eighty Five 85 Eighty Five 85 Eighty Five 85 Eighty Five
86 Eighty Six 86 Eighty Six 86 Eighty Six 86 Eighty Six
87 Eighty Seven 87 Eighty Seven 87 Eighty Seven 87 Eighty Seven
88 Eighty Eight 88 Eighty Eight 88 Eighty Eight 88 Eighty Eight
89 Eighty Nine 89 Eighty Nine 89 Eighty Nine 89 Eighty Nine
90 Ninety 90 Ninety 90 Ninety 90 Ninety
91 Ninety One 91 Ninety One 91 Ninety One 91 Ninety One
92 Ninety Two 92 Ninety Two 92 Ninety Two 92 Ninety Two
93 Ninety Three 93 Ninety Three 93 Ninety Three 93 Ninety Three
94 Ninety Four 94 Ninety Four 94 Ninety Four 94 Ninety Four
95 Ninety Five 95 Ninety Five 95 Ninety Five 95 Ninety Five
96 Ninety Six 96 Ninety Six 96 Ninety Six 96 Ninety Six
97 Ninety Seven 97 Ninety Seven 97 Ninety Seven 97 Ninety Seven
98 Ninety Eight 98 Ninety Eight 98 Ninety Eight 98 Ninety Eight
99 Ninety Nine 99 Ninety Nine 99 Ninety Nine 99 Ninety Nine
100 One Hundred 100 One Hundred 100 One Hundred 100 One Hundred
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
First_Envelope_and_Bid_Forms.xlsx
xlsx • 1.14 MB
Price_schedule.xlsx
xlsx • 0.69 MB
00_Cover Pages _Volume-III.doc
doc • 0.81 MB
01_Attachment-3(QR).doc
doc • 0.11 MB
02-Attachment-8- MAF_TL01.doc
doc • 0.04 MB
03-Attachment-18-SAFETY PACT.docx
docx • 0.03 MB
04_ Attachment 20_KMP-Declaration.doc
doc • 0.05 MB
05_Attachment-21- Authorization Certificate issued by Domestic Manufacturer I&S.docx
docx • 0.02 MB
06_Attachment-22- Affidavit for Self Certification reg Domestic Value Addition I&S.docx
docx • 0.02 MB
07_Attachment-23- Affidavit for self-Certification reg PPP-MII.DOCX
docx • 0.02 MB
08_Attachment-24- Certificate from Auditor reg PPP-MII.docx
docx • 0.02 MB
09_Attachment-25-Compliance to the process related to the e-RA.docx
docx • 0.02 MB
10_Attachment-26_Declaration regarding events encountered.docx
docx • 0.03 MB
11_Attachment-27-Certification by the Bidder as per DoE Order.docx
docx • 0.02 MB
12_Legends.pdf
pdf • 0.03 MB
First_Envelope_and_Bid_Forms_1.xlsx
xlsx • 1.14 MB
Price_schedule_1.xlsx
xlsx • 0.69 MB
HARD ROCK EARTHING.pdf
pdf • 0.19 MB
Individual Leg SST.pdf
pdf • 0.58 MB
Insulator Packing drawing PVC type.pdf
pdf • 0.88 MB
Insulator Packing drawing.pdf
pdf • 0.09 MB
pile earthing Drawing.pdf
pdf • 0.30 MB
Revised Bird Guard Sheet 1 of 2.pdf
pdf • 0.10 MB
Revised Bird Guard Sheet 2 of 2 .pdf
pdf • 0.11 MB
Rod Type Earthing.pdf
pdf • 0.15 MB
Standard drum Drawing Conductor & Earth Wire.pdf
pdf • 0.71 MB
Steel Drum Drawing (HTLS Conductor).pdf
pdf • 0.25 MB
Tower & Access R1.pdf
pdf • 2.86 MB
Wooden Drum Drawing (HTLS Conductor).pdf
pdf • 0.22 MB
132kV-765kV DC std hw (Part-5).pdf
pdf • 2.20 MB
132kV-765kV DC std hw (Part-6).pdf
pdf • 3.53 MB
220 KV SISP WITH BALANCING WT Model (1).pdf
pdf • 0.08 MB
220KV DT.pdf
pdf • 0.11 MB
500HVDC- 765SC string drg.pdf
pdf • 0.86 MB
800kV HVDC string drg.pdf
pdf • 1.63 MB
BIRD DIVERTER DRAWING.pdf
pdf • 0.07 MB
bird gurad for V String.pdf
pdf • 0.35 MB
Chemical Counterpoise.pdf
pdf • 0.10 MB
Chemical Pipe Type.pdf
pdf • 0.10 MB
Covered grading Ring Drawing.pdf
pdf • 0.62 MB
Extension application scheme.pdf
pdf • 0.06 MB
GA_A_PROP TYPE SST Model (1).pdf
pdf • 0.17 MB
132kV and 220kV Typical Tower.pdf
pdf • 0.04 MB
132kV-765kV DC std hw (Part-1).pdf
pdf • 2.34 MB
132kV-765kV DC std hw (Part-2).pdf
pdf • 2.74 MB
132kV-765kV DC std hw (Part-3).pdf
pdf • 2.25 MB
132kV-765kV DC std hw (Part-4).pdf
pdf • 2.46 MB
07_3 Section VII B HTLS Conductor Rev-3(Jan'2022).pdf
pdf • 0.98 MB
08_1 Section VIII Composite Longrod Insulator, Rev-2(Jan'2022).pdf
pdf • 1.09 MB
09_1 Section-IX Pile Foundaton,Rev-2(Feb'2022).pdf
pdf • 1.13 MB
10_1 Section X OPGW.pdf
pdf • 4.43 MB
12_Section XII FAQ.pdf
pdf • 0.37 MB
05_1 Section V Earthwire.pdf
pdf • 0.37 MB
05_2 Section V (MQP for Earthwire).pdf
pdf • 0.90 MB
06_1 Section VI A Hardware Fittings Clamp and Accessories for Conductor & Earthwire Rev-2(Jan'22).pdf
pdf • 4.24 MB
06_2 Section VI B Clamp fittings and Accessories for HTLS Conductor,Rev-2(Jan'2022).pdf
pdf • 1.14 MB
07_1 Section VII A Conductor,Rev-2(Jan'2022).pdf
pdf • 1.15 MB
07_2 Section VII A (SMQP of Conductor).pdf
pdf • 2.13 MB
04_5 Section IVC Appendix II(Part-A) Precommissioning procedure, Rev-1 (Sept'2021).pdf
pdf • 1.89 MB
04_5 Section IVC Appendix II(Part-B) Precommissioning Formats, Rev-1 (Sept'2021).pdf
pdf • 2.38 MB
04_6 Section IVC Appendix III (SMQP of Trasnmission Line Tower.pdf
pdf • 3.40 MB
04_7 Section IVD Foundation (Contractor design),Rev-3(Apr'2022).pdf
pdf • 0.37 MB
04_8 Section IVE Foundation (Employer design),Rev-2(Jan'2022).pdf
pdf • 0.75 MB
04_9 Section IVF MonopoleRev-0(Feb'2022).pdf
pdf • 1.03 MB
01_1 Section IA (standard)ScopeRev-4(Apr'2022).pdf
pdf • 0.33 MB
01_2 Section IB General InformationRev-4(Apr'2022).pdf
pdf • 0.99 MB
02 Section II General Tehnical Conditions,Rev-2(Feb'2022).pdf
pdf • 0.84 MB
03_1 Section III Survey & Soil Investigation,Rev-2(Jan'2022).pdf
pdf • 0.91 MB
03_2 Section III Annexure-A(Format for site BOQ).pdf
pdf • 1.70 MB
03_3 Section III Annexure B-C-D-E(Formats for other site data).pdf
pdf • 0.48 MB
04_1 Section IVA Tower Design,Rev-4(Apr'2022).pdf
pdf • 0.33 MB
04_2 Section IVB Tower Testing,Rev-1(Sept'2021).pdf
pdf • 0.98 MB
04_3 Section IVC Fabrication, Erection & Stringing,Rev-3(Feb'2022).pdf
pdf • 1.00 MB
04_4 Section IVC Appendix I (List of T&P).pdf
pdf • 0.83 MB
15.0 Civil Works Rev 11A_With Correction Slip.pdf
pdf • 0.81 MB
16.0 Section Structure Rev 6.pdf
pdf • 0.10 MB
17.0 Lighting Specification Rev.07.pdf
pdf • 1.43 MB
18.0 Section Telecommunication Systems Rev 02.pdf
pdf • 1.78 MB
Section-Sub-station Automation_Rev04.pdf
pdf • 0.98 MB
Section-Sub-station Automation_STANDARD FACTORY SIMULATION TEST PLAN.pdf
pdf • 0.54 MB
Section-Switchgear-INST_rev11.pdf
pdf • 1.00 MB
Section-Switchgear-SA_Rev12.pdf
pdf • 0.34 MB
Section Project JPCL package.pdf
pdf • 0.39 MB
10.0 Air conditioning R4.pdf
pdf • 0.04 MB
11.0 Section_Switchyard Erection_Rev.10.pdf
pdf • 5.99 MB
12.0 CRP Rev 09.pdf
pdf • 0.37 MB
8.0 Fire Protection Rev 6.pdf
pdf • 1.97 MB
9.0 Power & Control Cable Rev R6.pdf
pdf • 0.26 MB
1.0 GTR Rev 15 .pdf
pdf • 7.12 MB
4.0 GIS Rev-5A.pdf
pdf • 1.95 MB
5.0 LT Switchgear R5.pdf
pdf • 0.47 MB
7.0 PLCC R5.pdf
pdf • 0.06 MB
Annexure -VI_Specific Requirement Rev 6.pdf
pdf • 7.03 MB
AnnexureIII_Standard GIS module Description.pdf
pdf • 0.15 MB
Annexure-IV & V.pdf
pdf • 2.24 MB
28mm Dia Foundation bolt.pdf
pdf • 0.08 MB
474001-220kv 2BPI(SH.1 OF 1).pdf
pdf • 0.49 MB
474003-220kv 2CVT(SH.1 OF 1).pdf
pdf • 0.45 MB
474004-220kv 2LA(SH.1 OF 1).PDF
pdf • 0.43 MB
B1_T_T2.pdf
pdf • 0.21 MB
B2_SLD.pdf
pdf • 0.06 MB
CABLE TRENCH & CROSSING DETAILS.pdf
pdf • 0.63 MB
GA_New Melli.pdf
pdf • 1.75 MB
RCC ROAD.pdf
pdf • 2.81 MB
SLD_New Melli.pdf
pdf • 0.26 MB
STD DRAIN.pdf
pdf • 2.24 MB
00_Cover Pages _Volume-I.doc
doc • 0.81 MB
01_Main Index_Volume-I.docx
docx • 0.01 MB
02_Section-I_Invitation for Bids (IFB).docx
docx • 0.09 MB
03_Section-II_Instructions to Bidders (ITB)_PRANIT_July 2021.pdf
pdf • 0.75 MB
04_Section-III_Bid Data Sheets (BDS).docx
docx • 0.10 MB
05_Annexure-A (BDS).docx
docx • 0.07 MB
06_Annexure-B (BDS).pdf
pdf • 0.65 MB
07_Annexure-C(BDS).docx
docx • 0.07 MB
08_Section-IV_General Conditions of Contract (GCC).pdf
pdf • 1.93 MB
09_Section-V_Special Conditions of Contract (SCC).docx
docx • 0.09 MB
10_Appendix-I to SCC.pdf
pdf • 0.39 MB
11_Section - VI_Sample Forms and Procedures (SFP).doc
doc • 0.56 MB
Clarification-5.docx
docx • 0.05 MB
Price_schedule Rev_03.xlsx
xlsx • 0.68 MB
Extension-3_Letter.docx
docx • 0.15 MB
First Envelope and Bid Forms Rev-02.xls
xls • 2.54 MB
Price_schedule Rev_02.xlsx
xlsx • 0.69 MB
Extension-2_Letter.docx
docx • 0.19 MB
Clarification-2.pdf
pdf • 0.54 MB
First Envelope and Bid Forms Rev-01.xlsx
xlsx • 1.14 MB
00_Letter_to_the_Bidders.docx
docx • 0.19 MB
Price_schedule Rev_01.xlsx
xlsx • 0.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .