Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC LOWER MAWPREM LUMSOHPHOH SHILLONG 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹17.9 L+₹2.4 L (15.7%)Rejected-Finance HOWELL ROAD LABAN SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹18.6 L+₹3.1 L (20.0%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
Tender Value
₹19.9 L
EMD Value
₹40,000
Closing Date
17 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Umroi
Military Engineer Services Garrison Engineer Umroi Umroi Military Station PO - Barapani, Shillong-793 103
REPAIRS REPLACEMENT OF SERVICEABLE WATER TANK AND ALLIED SERVICES OF ZONE III AT UMROI MIL STN UNDER GE UMROI
2021_MES_424126_1
8172/E8
Open Tender
Civil Works
Item Rate
180 days
Umroi
As per NIT
6 documents required · 6 mandatory
₹500
GE Umroi
₹40,000
Yes
23 Mar 2021
20 Feb 2021
19 Mar 2021
20 Feb 2021
17 Mar 2021
4 Mar 2021
60 days
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specified, complete all as specified and as directed.
Material and labour for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following steps and specifications:- a) Applying crack seal compound of same manufacture of waterproof to fill all cracks of observed on the roof. b) Applying cement slurry over concrete surfaces @3kg/sqm. c) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound as per manufactures’ instruction(not less than 3% by weight of cement) on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course). d) Applying evenly one coat of primer coating (diluted with water in the ratio specified by Manufacturers) (min @100-110Sq Ft per liter (diluted quantity)) on the cleaned plastered surfaces. The surface shall be left for air dry for minimum period of 2-3 Hrs. e) Applying evenly one coat of elastomeric water proof coat in one direction (as specified by Manufacturers)(min@ 0.9-1.0 sqm per ltrs) and allow to air dry for 4-6 hrs before applying second coat in other direction perpendicular to the first one (as specified by Manufacturers) (min @0.9-1.0 sqm per ltrs. The total thickness of two coats shall be 0.5 to 0.6 mm. f) The whole system shall be left for air cure for min Seven days (without any movement). Make : - Dr Fixit Newcoat Ezee or Berger Home Shield PU RoofKoat or Asian Paints Smartcare Damp Proof or as equivalent approved by GE. Note : - (i) The waterproofing shall be carried out in the last stage of execution to avoid any damages during the execution. (ii) Payment against this item shall not be allowed till completion of all the stages of work for any slab. (iii) The work shall be executed through well-trained applicators as per manufacturer’s instructions after obtaining written approval from the GE
M&L for 25mm thick (average thickness) PCC 1:2:4 type B-0, using 12.5mm graded stone aggregate all as specified and directed.
Material & Labour for precast cement concrete ( 1:3:6), type C-1, (using 20mm graded stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar (1:4) etc complete as specified.
Material & Labour for 15mm (10+5mm) thick external wall plastering in CM (1:4) in two layers mixed with water proofing compound @ 3% by weight of cement in top 5mm thick finished the surfaces even & smooth without using extra cement complete all as specified and directed. (Note : Water proofing compound shall be measured and paid separately)
Supply only integral water proofing compound
M & L cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) all as specified and directed.
Supply & Fixing Rotational moulded polyethene water storage tanks 500 lit capacity with lid (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I , complete all as directed by Engr-in- Charge.
Supply & Fixing 20mm dia gun metal,globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in repairs complete all as specified and as directed.
Supply & Fixing 20mm dia ball brass valve high pressure with polythene float and fly nut complete scrwed for iron pipe or brass ferrule and fixed in repairs complete all as specified and as directed.
S&F in repair 20mm bore nipple suitable for HDPE water tank (minimum weight 45 gms), complete all as specified and directed.
Taking up or down steel tubing and conncection 20 mm, incl cleaning for re-fixing or removal to store all specified and directed.
Supply & Fixing Tubes medium grade, 20 mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and as directed.
Refixing old steel tubing 20 mm dia and connection in new or old position complete all as specified and directed by Engr in charge.
Taking up or down steel tubing and conncection 15mm, incl cleaning for re-fixing or removal to store complete all as specified and as directed.
Refixing old steel tubing 15 mm dia and connection in new or old position complete all as specified and directed by Engr in charge.
Supply & Fixing Tubes medium grade, 15mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors Complete all as specified and directed.
S&F in repair 25 mm bore nipple suitable for HDPE water tank (minimum weight 45 gms), complete all as specified and directed.
Taking up or down steel tubing and conncection 25 mm, incl cleaning for re-fixing or removal to store all specified and directed.
Supply & Fixing Tubes medium grade, 25 mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and as directed.
Demolition cement concrete (un-reinforced) of any descriptions, in Ground Floors (Floor Topping, Sub-base, etc.) not exc. 150mm thick, above or below Ground Level, complete all as specified and directed
M&L 75 mm thick Cement concrete type C 2, 1:3:6 (using 40 stone aggregate) in plinth protection, finished even and smooth without using extra cement.
M&L Cement concrete 1:3:6 type C-1, using 20 mm graded crushed stone aggregates as in surface channel and drains, complete all as specified and directed
Extra for forming fair finished drain or drain channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred stopped ends etc complete all as specified and directed.
Demolition of reinforced cement concrete of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified and directed.
M&L for providing plain cement concrete in surface channel type E 2, 1:5:10 (40 mm graded aggregate) over chajja including cover fillets at junction of roof slab and wall etc complete all as directed.
Material & Labour for 10 mm thick external plastering in CM (1:6) mixed with water proofing compound @ 3% by weight of cement and finished the surfaces even & smooth with using extra cement complete all as specified and directed. (Note : Water proofing compound shall be measured and paid separately)
TMT bars 6mm to 8 mm over cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or seuring with chip with deep quality confirming to Fe 500/550/Fe 500 D/550D all as specified and directed.
Material and labour for complete removal of loose/ cracked concrete including reinforcement if required from RCC roof projection, chajja, fins, facia etc and making good with RCC (1:2:4) type A0 using 12.5 mm graded aggregate) in any slab over use of any approved concrete adhisive and in any position finsihed the surface even and smooth with out using extra cement including necesary formwork and weldign/binding of reinforcement ( including reinforcement) if required complete and ( Note:- reinforcement will be measured and paid seperately under respective items)
M& L for applying 2 coats of weather proof coat paints of approved make and over one coat of primer to match with existing surfaces all as specified and directed by engineer in charge complete.
Schedule of Credit
M/s Eddy Constructions
MOINUL HOQUE CHOUDHURY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .