Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹11.5 L+₹2.2 L (23.3%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹13.8 L+₹4.5 L (48.8%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹14.0 L+₹4.7 L (50.1%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹14.0 L+₹4.7 L (50.5%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Jun 2023, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINT TO SEWAGE LINE, SOAKAGE WELL, SEPTIC TANK INCLUDING CLEANING OF SEWAGE LINE, SEPTIC TANK AND MANHOLES IN ZONE -1 (A) UNDER AGE B/R IV OF GE(S) JAIPUR AT JAIPUR MIL STATION
2023_MES_600356_1
GE (S)/J-09P OF 2023-24 8806/E8
Open Tender
Civil Works
Item Rate
330 days
Jaipur
E class and a (i) and or a (ii) category
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹40,000
Yes
17 Jul 2023
3 Jun 2023
30 Jun 2023
3 Jun 2023
28 Jun 2023
16 Jun 2023
Amount
M&L for Cleaning and maintanance of sewage system including day to day complaints viz removing all type of blockage from wash hand basins, bottle trap, Gully trap kitchen sink, water closet, etc including sewage lines of any dia, up to first manholes, by providing all tools and plants including bamboos, iron rod, bucket, rope ladder and manpower as required etc complete. (Note :- (i) Contractor has to provide minimum two Nos safaiwalas/sweepers daily for sewage cleaners to attend the sewage complaint received day to day by sub division. (ii) Any complaint which is not completed within two days from the date of issue of complaint. Compensation will be charged @Rs. 200/-per day for each caplaint upto 02 days delayed and beyond 2 days and above every additional day delayed will be charged @Rs. 50/-per day each complaints. (iii) Nos of blockage/complaints cleared/attended per day as recorded in MB is to be paid to the contractor as each Job in one Bldgs/block etc which includes sewer line also. (iv) Cleaning of septic tank and soakage well/man holes are paid separately under relevant item here in after.
M&L for Cleaning of sewage line of 150mm dia of SGWG /RCC NP 2 pipe or any other specification having depth n.exc 2.0 m below ground level including removing all type of blockage from manholes, to manholes by manual and /or mechnical means including providing all tools and plants bamboos, iron rod, bucket, rope, ladder etc complete. Note :- Contractor has to depute extra labour for cleaning of sewage lines to clear the blockage in sewer lines as and when required and disposing off all sludge waste debries etc outside MD land and refixing MH cover complete.
All aper Ser item No 02 above but 200 mm dia and above (depth exc 2.0m but n.exc 4.5 m below Ground Level
M&L for scooping and taking out sludge and foreign material from septic tank, soak well and sump/well of any description of any depth but not exceeding up to 4.5 m and including removing and re-fixing of manholes covers, septic tank and soak well cover etc and appliances required for safe disposal of sludge and foreign material by carrying out the same covered van/trolley out side defence land and it should be disposed off at distance not less than 1.5 KM away at such place which is not detrimental to public health and as per direction of Engineer-in-Charge. Note :- Net volume of internal size of each septic tank, soakage well, up to the depth of water from bottom shall be measured for payment purpose including dewatering and removing dry/wet sludge etc complete all as specified and as directed.
All as per serial item No. 04 here-in-before but for manholes any size of depth n. exc 1.5 metre below Ground Level complete all as specified and as directed.
All as per serial item No. 04 here-in-before but for manholes any size of depth exc 1.5 metre but n.exc 3.0 metre complete all as specified and as directed.
All as per serial item No. 04 here-in-before but for manholes any size of depth exc 3.0 metre but n.exc 4.5 metre complete all as specified and as directed.
M&L for Excavation in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. n exc 10sq m on plan & n exc 1.5m in depth & getting out in soft/loose soil complete all as specified and as directed.
All as per serial item No. 08 here-in-before but depth exc. 1.50 m but n. exc. 3.00 m complete all as specified and as directed.
All as per serial item No. 08 here-in-before but depth exc. 3.0 m but n. exc. 4.50 m complete all as specified and as directed.
M&L for use and waste of timbering exc 3m & n exc 4.5mtr depth as planking and strutting for excavation in trenches in soil, including wales, struts, open poling boards, shafts, wells, cesspits, manholes and pier holes complete all as specified and as directed. (Note : the measurement shall be taken before the excavation is filled in and timbering is removed). However this item shall be operated with prior written approval of necessity by GE.
M&L for Removing excavated soil n exc. 50m & depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M&L for Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and as directed.
M&L for cutting into existing manholes for connecting new drains of 150mm dia bore including making good to pipe with rendering, cutting out existing benching, forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished & reforming benching as required complete all as specified and as directed.
M&L for cutting into existing manholes for connecting new drains of 200mm dia bore including making good to pipe with rendering, cutting out existing benching, forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished & reforming benching as required complete all as specified and as directed.
M&L for demolition and breaking up drain pipes salt glazed ware set in CM of 150 mm dia bore pipe complete all as specified and as directed.
M&L for Demolition and breaking up drain pipes salt glazed ware set in CM 200 mm bore pipe complete all as specified and as directed.
M&L for concrete bed to 150mm dia bore drain pipes including packing under & haunching against the sides of pipes after they are laid & tested; in PCC (1:4:8) type D1 complete all as specified and as directed.
All as per Ser item No 18 above but 200mm dia bore pipes complete all as specified and as directed.
M&L for 150mm dia bore salt-glazed stoneware drain pipes grade 'A" laid in trenches and jointed complete all as specified and as directed.
M&L for 150mm dia bore Reinforced Concrete pipe Class NP-2 laid in trenches & jointed complete all as specified and as directed.
M&L for 200mm dia bore Reinforced Concrete pipe Class NP-2 laid in trenches & jointed complete all as specified and as directed.
M&L for dismantling of 100 mm dia cast iron / PVC Pipe or reinforced concrete drain pipes, jointed in cement mortar and taking out from trenches, if required complete all as specified and as directed.
M&L for dismantling of 75 mm dia cast iron / PVC Pipe or reinforced concrete drain pipes, jointed in cement mortar and taking out from trenches, if required complete all as specified and as directed.
M&L for demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed.
M&L for taking down cement plaster or cement lime plaster on brick or stone walls etc including raking outs joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:4 on fair or unfair face of brick work or concrete surfaces finished even and fair complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 (40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in coping including necessary form work complete all as specified and as directed.
M&L for precast RCC 1:2:4 type B1 using 20 mm graded stone aggregate for manhole cover with plain fair faces including chamfers, weatherings, throating etc and setting in mortar complete with joints to match including demolition of old RCC manhole / drain covers complete all as specified and as directed. Note :- Reinforcement shall be measured and paid for separately.
S&F TMT bar 8 mm dia , cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in surface channel and drains, forming fair & finished drain or channel complete all as specified and as directed.
S&F sand cast iron soil waste and vent pipes in any length with or without ears with cement joints in walls/floors of 100 mm bore complete all as specified and as directed.
All as per serial item no 34 here-in-before but 75 mm complete all as specified and as directed.
S&F in repair cast iron bends (any) radius of 100 mm bore with access door all as specified complete all as specified and as directed.
All as per serial item no 36 here-in-before but 75 mm complete all as specified and as directed.
S&F in repair cast iron cowls of 100 mm complete all as specified and as directed.
S&F in repair cast iron cowls of 75 mm complete all as specified and as directed.
S&F in repair PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joint fixed to walls complete all as specified and as directed.
All as per serial item no 40 here-in-before but 75 mm complete all as specified and as directed.
S&F in repairs PVC (SWR) 110mm bend complete all as specified and as directed.
S&F in repairs PVC (SWR) 75mm bend complete all as specified and as directed.
S&F in repair ,PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) as required complete all as specified and as directed.
S&F in repairs PVC (SWR) pipes 110mm fittings double Tee 'T'equal or unequal complete all as specified and as directed.
S&F in repairs PVC (SWR) pipes 75mm fittings double Tee 'T'equal or unequal complete all as specified and as directed.
ANKIT BUILDERS
J.J.ENGINEERING
C.P.Computers
M/S ROHIT CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .