Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.2 L+₹93,330 (11.3%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹9.6 L+₹1.4 L (17.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹9.7 L+₹1.5 L (18.4%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹12.5 L+₹4.3 L (51.8%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
1 Aug 2022, 6:00 pmClosed
GE (AF) BHISIANA
GE (AF) BHISIANA PIN-151201
AS PER BOQ/PRICE SCHEDULE
2022_MES_532420_1
GE/BHI/T-51/2022-23
Open Tender
Civil Works
Item Rate
273 days
GE (AF) BHISIANA
AS PER NIT/TENDER DOCUMENT
6 documents required · 6 mandatory
₹500
Yes
GE (AF) BHISIANA
₹30,000
Yes
13 Sept 2022
21 Jun 2022
3 Aug 2022
21 Jun 2022
1 Aug 2022
9 Jul 2022
28 Jun 2022 - 5 Jul 2022
Amount
Excavation in trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ loose Soil and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 metre and depositing where directed at a level not exc. 1.50 metre above the starting point, complete all as specified and as directed.
M&L Sand (Fazilka) Cushioning (dry) in trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (15 Cm in depth before laying the Cable and 8 Cm in depth after laying the Cable) and consolidated (punned) upto 18 Cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
M&L for Brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed.
S&F in Replacement of MCCB 400 Amps, 4 Pole 36/37 KA with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
M&L for Making bore below the road for crossing the GI pipe light grade 50 mm dia for cable protection and fill the putty on both sides of the GI pipe after crossing the armoured cable to avoid the water inside complete all as specified and directed by Engr-in-Charge.
M&L for making bore below the road for crossing the GI pipe light grade 80 mm dia for cable protection and fill the putty on both sides of the GI pipe after crossing the armoured cable to avoid the water inside complete all as specified and directed by Engr-in-Charge.
M&L for making bore below the road for crossing the GI pipe light grade100 mm dia for cable protection and fill the putty on both sides of the GI pipe after crossing the armoured cable to avoid the water inside complete all as specified and directed by Engr-in-Charge.
M&L for galvanized steel tubing 100 mm light garde for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
All as per item No. 10 above but having size 80 mm.
All as per item No. 10 above but having size 50 mm.
Taking down LT cable 1100 Volts grade heavy duty UG cable XLPE/PVC of size from 185 to 240 sqmm, 3½ core.
Taking down LT cable 1100 Volts grade heavy duty UG cable XLPE/PVC of size from 70 to 150 sq mm, 3½ core.
Taking down LT cable 1100 Volts grade heavy duty UG cable XLPE/PVC of size from 10 to 50 sq mm, 2 to 4 core.
M&L for Taking down unserviceable LT UG cable any type from trenches and removing the fault and relaying of LT UG cable after rectifying the fault and making cable in serviceable condition of 1100 V grade UG cable of size from 185 to 240 sq mm, 3½ core including relaying of bricks, sand and refixing as existing complete all as specified. Note : (i) Straight through joints measured and paid seaprately. (ii) Excavation, Returning, filling, removal will be measured and paid separately.
M&L for Taking down unserviceable LT UG cable any type from trenches and removing the fault and relaying of LT UG cable after rectifying the fault and making cable in serviceable condition of 1100 V grade UG cable of size from 70 to120 sqmm, 3½ core including relaying of bricks, sand and refixing as existing complete all as specified. Note : (i) Straight through joints measured and paid seaprately. (ii) Excavation, Returning, filling, removal will be measured and paid separately.
M&L for Taking down unserviceable LT UG cable any type from trenches and removing the fault and relaying of LT UG cable after rectifying the fault and making cable in serviceable condition of 1100 V grade UG cable of size from 10 to 50 sq mm, 2 to 4 core including relaying of bricks, sand and refixing as existing complete all as specified. Note: (i) Straight through joints measured and paid seaprately. (ii) Excavation, Returning, filling, removal will be measured and paid separately.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 240 Sq mm 3.5 Core with aluminum thimble of same size complete all as directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 185 Sq mm 3.5 Core with aluminum thimble of same size complete all as directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 150 Sq mm 3.5 Core with aluminum thimble of same size complete all as directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 120 Sq mm 3.5 Core with aluminum thimble of same size complete all as directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 Sqmm 3.5 Core with aluminum thimble of same size complete all as directed.
Supply, laying, jointing and testing XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 Sq mm 3.5 Core with aluminum thimble of same size complete all as directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50 Sqmm 3.5 Core with aluminum thimble of same size complete all as directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 Sq mm 3.5 Core with aluminum thimble of same size complete all as directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sqmm 3.5 Core with aluminum thimble of same size complete all as directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core with aluminum thimble of same size complete all as directed.directed.
M&L for Cable jointing kit for 1100 volts grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Aluminium conductor cable of size 35 to 95 sqmm, complete all as directed at site.
All As per Item No. 29 above but for cable of size 120 to 150 sqmm.
All As per Item No. 29 above but for cable of size185 to 240 sqmm.
M&L for PCC (1:3:6) type C-1 with 20 mm gradded stone aggregate for copping of poles Pedestal (PCC) or complete all as specified and directed by Engr-in-Charge.
M&L in replacement for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 32x6 mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type C-1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting book made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.
S&F in replacement of Aluminium Cable Lugs/ Thimbles suitable for XLPE Aluminium Conductor Cable,of following sizes, complete all as specified and directed.
M&L for Preparation of Old steel surfaces including welding work of door, hinges with locking arrangement and applying one coat of synthetic enamel ivory paint/(Smoke grey) to steel LT Panel/bus bar box and junction boxes surface after disconnecting the electrical connections and reconnecting LT cables after painting, complete as specified and directed by Engr-in-Charge.
S&F of Sheet metal (MS) bus bar box single door, out door type weather proof, size 300x300x200mm mounted on ground with iron angles (25x25x4mm). Having alluminium bus bar 4 Nos, rated 100 Amp all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB 315 Amps, 4 Pole 25/35KA with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
Servicing of LT panel of any size including disconnecting of supply, removing brunt out wires, cable joints, thimbles, MCCB and bus bar Including supply of copper wires, thimbles, rejointing of any size cable with bus bar and MCCB properly. Cables of damaged PVC insulation will rejoint after removing damaged piece of cable and making new joint.
Cleaning of area around the switch gears transformers and sub station etc including removing grass tree roots/ shurbs etc Upto 100 Sqm and also removing extra soil all as directed by Engineer-in-Charge.
S&F in replacement of MCCB 40 Amps, 4 Pole, 16/25 KA with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
S&F in replacement of MCCB 63 Amps, 4 Pole 16/25 KA with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
S&F in replacement of MCCB 100 Amps, 4 Pole 25 KA with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
S&F in replacement of MCCB 125 Amps, 4 Pole 16 Ka with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
S&F in replacement of MCCB 160 Amps, 4 Pole 16 Ka with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
S&F in replacement of MCCB 200 Amps, 4 Pole 25/26KA Ka with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
S&F in replacement of MCCB 250 Amps, 4 Pole 25/26 KAwith thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.
Aman Enterprises
Rasvinderpalandco
REYANSH GARG AND COMPANY
KAY VEE CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .