| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC MASTER BUILDING DALHOUSIE ROAD DALHOUSIE ROAD PATHANKOT PATHANKOT GURDASPUR PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹8.5 L+₹65,390 (8.38%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹8.6 L+₹84,340 (10.8%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN L1 | |
| 4 | L4₹9.5 L+₹1.7 L (22.0%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L4 | Rejected-Finance BEING OTHER THAN L1 | |
| 5 | L5₹12.0 L+₹4.2 L (53.4%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance BEING OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
26 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
REPAIR/ MAINTENANCE OF VOLTAGE STABILIZER, UPS AND OTHER CONNECTED ITEMS AT AIR FORCE STATION PATHANKOT
2020_MES_391117_1
GE/PAF-50/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) PATHANKOT
As Per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹30,000
Yes
1 Feb 2021
29 Oct 2020
28 Nov 2020
29 Oct 2020
26 Nov 2020
12 Nov 2020
60 days
Amount
Taking out unserviceable control wiring complete form stabilizer/isolation transformer any cap up to 200 KVA 3 phase 415 volts for unbalanced load. Providing wiring loom complete to the stabilizers made out of suitable size PVC insulated copper conductor cable including cables lugs, connectors, channels etc complete all as specified and directed by Engineer-in-Charge. (additional items required to make stabilizer serviceable will be measured separtely under resepctive items).
Supplying and fixing in replacement if required digital voltmeter range form 0-500 Volt AC 230 Volt as per site requirment complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement if required digital voltmeter range form 0-500 Amp AC 230 Volt with CT as per site requirment complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement if requiredprinted control card circuit suitable for AE Make voltage stabilizers any Cap complete all as specified and directed by Engineer-in-Charge.
All as per item No 4 above but suitable for Blue line make voltage stabilizer any Cap complete all as specified and directed by Engineer-in-charge.
All as per item No 4 above but suitable for Vintech make Voltage stabilizer any cap complete all as specified and directed by Engineer-in-Charge.
All as per items No 4 above but suitable for Specturn make Voltage stabilizer complete all as specified and directed by Engineer-in-Charge.
All as per items No 4 above but suitable for Muskan make Voltage stabilizer complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement holder for printed control card circuit suitable for any make voltage stabilizer including connections by soldering complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement limit switch suitable to cut off supply to synchronous motors on high and low set limits as per sample complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement toggle switch 2 way 5 amps 230 volts including connecting electrically complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement if required synchronous motor single phase AC 230 volts suitable to work with voltage stabilizer upto 50 KVA cap of existing make with torque 3 Kg/ CM complete all as specified and directed by Engineer-in-Charge.
All as per item No 12 above but suitable for voltage stabilizer abvoe 50 KVA upto 200 KVA capacity of exisiting make with torque 3 Kg/ cm complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement gear suitable for synchronous motors to operate the shaft for variable dimmer stat complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement indicator with bulb, red, yellow or green 230 volts as per samble complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement control transformer with primary voltage 230 volts and secondary voltage any desired voltage between 12 volts to 60 volts to suit the control circuit of the stabilizer as per sample complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement push button any type and size as per sample, suitable to operate the synchronous motor manually complete all as required at site and directed by Engr-in-Charge.
Supplying and fixing in replacement variable resistance (pre set) with lock nuts suitable for fine adjustement of output voltage on auto mode complete all as specifed and directed by Engr-in-Charge.
Supplying and fixing in replacement capacitor of rating 1 to 2 mfd 230 volts complete all as required at site and directed by Engr-in-Charge.
Supplying and fixing in replacement resistance for synchrmous motor assy rating upto 1 K ohm 10 watt + 10% complete all as required at site and directed by Engr-in-Charge.
Supplying and fixing in replacement if required in repalcement dimmer stat suitable for voltage stabilizer of any cap upto 25 KVA of any make to match with existing system complete all as specified and directed by Engr-in-Charge.
All as per item No 22 above but above 25 KVA upto 50 KVA complete all as specified and directed by Engr-in-Charge.
All as per item No 22 above but above 50 KVA upto 100 KVA complete all as specified and directed by Engr-in-Charge.
All as per item No 22 above but above 100 KVA upto 200 KVA complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement carbon brush with holder as per sample suitable for voltage stabilizer of any make any cap upto 50 KVA complete all as specified and directed by Engr-in-Charge.
All as per item No 26 above but cap above 50 KVA upt 200 KVA complete all as specified and directed by Engr-in-Charge.
Taking out main transformer of the voltage stabilizer for repair/ rewinding. Rewinding of the main transformer using super enameled copper winding wire of existing gauge including latherire paper, PVC sheets, sleeves etc all as required. Varnishing complete with insulating varnish, drying and refixing to the stabilizer after testing all as required at site complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement brass studs with nuts, washers etc complete including porcelain bushes as per sample suitable for voltage stabilizers above 25 KVA upto 50 KVA cap any make all as required at site complete all as specified and directed by Engr-in-Charge.
All as per item No 29 above but above 50 upto 100 KVA complete all as specified and directed by Engr-in-Charge.
All as per item No 29 above but above 100 upto 200 KVA complete all as specified and directed by Engr-in-Charge.
Supplying and fixing AC coil suitable for Power contactor 70 to 110 Amp exciting voltage 240/415 Volt as per site requirment complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement operating coil of voltage 230 Volts for air break contactor from 200 Amps to 400 Amps all as required at site complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement operating coil of voltage 230 Volts for air break contactor up to 110 Amps all as required at site complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement operating coil of voltage 230 Volts for air break contactor up to 250 Amps all as required at site complete all as specified and directed by Engr-in-Charge.
Perodicat Maintenance as quertly basis or as per required basis for checking all power connections of cabling and its terminals , LCD diaplay boarde switches ,microprocessor based control band data monitoring system battery testing , ventilation fans including repair and M & L in replacement if required defective part immediately when found all as directed by Engineer in Charge Note : Spaire parts will be measured seperatly to this item (a) UPS 15 KVA - 02 Nos installed at PAR
(b) UPS 05 KVA - 01 Nos installed at Site II
(c) UPS 02 KVA - 03 Nos installed at MAFI I , II & Audotorium
Supplying and fixing repaire of single Phase invertor including taking out unserviceable controll wiring, rechanging card complete all as specified and directed by engineer-in-Charge.
Supplying and fixing in replacement maintinance free battery 12 volt 180 AH tubular type including battery leads and initial charging of battery complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement maintenance free dry type battery of cap 65 to 70 Ah 12 volts complete with connection to UPS complete all as specified and directed by Engr-in-Charge.
Earthing complete with copper earth plate electrode 600x600x 3.15 mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.25 Mtr below normal ground level connected to the copper strip 20x3 mm size by means of bolts ,nuts,check nuts and washers of galvanised iron and 20x3 mm copper strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-i , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 5 of MES Sch 191 Part-I all as specified and directed . (i) Main earthing lead from earth plate electrode to test point upto length of 7.5 meters length shall deem to be included in the unit rate quoted against this item . (ii) GI protection pipe & earthing lead beyond 7.5 metre shall be measured and paid for seperately under appropriate item of Sch A part-IV (Sec-I) . (iii) On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department .
Checking wiring to the APFC control panel including M & L in replacement if required fault circuit with copper conductor cable PVC insulated of size 1.00 sqmm/ 1.5 sqmm or as existing earlier complete including setting of control to display of voltage , current , Active power , reactive power , apparent power power , alarm indication for defective steps , low power factor and excess temperature , complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement APFC relays up to 7 stage complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement digital frequency meter 04 digit flush Mfd 96 Sqmm size for frequency range 30 to 19.99 Hz with built in transducer complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement digital power factor meter 440 volts 5 amps with built in transducer flush complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement capacitor for APFC panel 440 V olt 3 phase as per site requirment up to 5 KVA complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement capacitor for APFC panel 440 V olt 3 phase as per site requirment up to 12.5 KVA complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement capacitor for APFC panel 440 V olt 3 phase as per site requirment up to 20 KVA complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement capacitor for APFC panel 440 V olt 3 phase as per site requirment up to 25 KVA complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement capacitor for APFC panel 440 V olt 3 phase as per site requirment up to 50 KVA complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement Kit Kat fuse carrier including Fuse HRC T type of Capacity 32 Amp complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement Kit Kat fuse carrier including Fuse HRC T type of Capacity 63 Amp complete all as specrified and directed.
Supplying and fixing in replacement Kit Kat fuse carrier including Fuse HRC T type of Capacity 100 Amp complete all as specrified and directed.
Supplying and fixing top up of insulating oil conforming to IS 335 -1993 latest amendments for replacing the oil in stablizers with breaking capacity not less than 45kv complete all as specified and directed by Engr-in-Charge.
Dehydration including filteration and cleaning of stabilizer oil at different locations by stream line method dehydration plant including testing of samples before and after dehydration and filteration . Dielectric strength should not be less than 45 KV at 2.5 mm gap after dehydartion complete all as specified and directed by Engr-in-Charge. Note :- (i) Test result before and after filteration to be recorded as per the sample provided by Engr-in-charge. (ii) The rate quoted is deemed to be inclusive of making necessary connection and the connection to filteration plant from transformers and switchgear oil duly removing the inlet and outlet connections. (iii) For topping up transformer oil will be measured and paid separately under relevent item of schedule.
SATISH AND CO
M/S V K TRADERS
Vijay Kumar Contractor and Engineers
M/S SHRI RAM BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .