| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹5.9 L+₹31,159.33 (5.61%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹6.4 L+₹89,278.52 (16.1%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹6.8 L+₹1.2 L (22.1%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY SURATGARH
SURATGARH MIL STN
Provn of four toilet and bathroom at JCOs living under AGE B/R-II at Suratgarh Mil Stn
2022_MES_532630_1
GE (A) SOG - 32/22-23
Open Tender
Civil Works
Item Rate
120 days
SURATGARH
As per tender documents
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹16,000
Yes
29 Aug 2022
21 Jun 2022
29 Jul 2022
21 Jun 2022
27 Jul 2022
5 Jul 2022
Amount
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance exc 250 metre and not exc 500 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/ loose soil and getting out complete all as specified and directed by Engineer-in-Charge.
M&L Moorum/red bajri filling in floors or pavings, laid in layers not exc 15 cm thick spread, levelled and rammed including watering complete all as specified.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer-in-charge.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed by Engineer-in-charge.
M&L for hardcore of broken stone / boulders gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
M&L anti-termite treatment to the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified & as directed.
M&L anti-termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified & as directed.
M&L anti-termite treatment to the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & as directed.
M&L anti-termite treatment to the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified & as directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-charge .
M&L for cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and directed by Engineer-in-charge. Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
M&L for PCC (1:2:4) type B1, using 20mm graded stone aggregate as in coping, benching and bed blocks etc including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished even and fair complete all as specified and directed by Engineer-in-charge.
M&L for precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs of drains, manholes, septic tanks, soakage wells etc. including placing in position and set in CM (1:6) complete all as specified & as directed by Engineer-in-charge. Note: - Reinforcement shall be measured and paid for separately.
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and other similar works complete all as specified and directed and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) nominal mix as in beams , cantilever, bressummer, lintel over 1.5m span and similar work complete all as specified and directed by Engineer-in-Charge
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for brick work built in CM (1:4) using sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls complete all as specified and directed by Engineer-in-charge.
M&L for use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work exceeding 200mm thick (horizontal or sloping), rough finished surface of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for use and waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
M&L for 30mm thick flush shutter solid core construction with block board core & ply wood face panels, commercial type on both faces complete all as specified and directed by Engineer-in-charge.
S&F 35mm thick factory made moulded door shutter constisting of soild core single leaf flush door of 30mm thickness, lipped with 15mm (5mm x 30 thick x 30mm width on one stiles and top reails & bottom rails. The inner panel laminated with 2mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2 raised panel design in different plain and 2mm plain coloured PVC sheet on other side using rubber adhesive on flush door & solvent cement adhesive on the PVC lipping etc incl all necessary fitting complete all as specified directed by Engineer-in-Charge
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified & shown in relevant drawing of item No. 08095 in MES Schedule (Part-II) and directed by Engineer-in-Charge
S&F 200 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 125mm size mild steel butt hinges cold rolled medium weight (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 100mm size butt hinges of extruded aluminium alloy with galvanized mild steel hinge pin, anodized type B-21 (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 300mm long aluminium alloy anodised sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 150mm long extruded aluminium handles, anodised, fabricated type (ISI marked) complete all as specified and directed by Engineer-in-Charge
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring overall length of cover plate 140mm (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel pipes as in Hand rails,half round,nosing to steps including embedding in concrete securing bolts,posts and struts in fencing incld drilling bolting or riveting etc. wind tie for roof including cutting topes to shape as directed, drilling holes, notching for wire etc, flat iron (for securing wire mesh) conforming to Fe-290 Gde E-165, complete all as specified and directed by Engineer-in-Charge.
S&F mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
S&F mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
All as per serial item No 38 here-in-before but 5mm dia and over up to and including 10mm dia as in stirrups, spacers & binder etc.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conforming to Fe-290 (Gde E- 165, complete all as specified & directed by Engineer-in-charge.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand 12mm sq guard bar, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by Engineer-in-charge.
S&F factory made steel ventilator with top hung shutter including hinges, steel peg stay, handle including one shop coat of Zinc Chromate primer and cutting holes in brick wall built in cement mortar for inserting lugs and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified and directed by Engineer-in-charge.
S&F pressed steel frames for door of size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc made out of mild steel sheet of 1.25mm thickness complete all as specified and as directed by Engineer-in-charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed by Engineer-in-charge.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick (minimum size 550mm x 550mm or size as directed) laid over & including screed bed or bedding layer of 15mm thick in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for machine cut Kota stone slab 18 to 20mm thick (minimum size 550mm x 100mm or size as directed), on vertical surfaces such as dado, skirting, raiser of steps etc. laid over & including rendering 10mm thick in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, grinding, rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for 25mm thick PCC (1:2:4) type B1 using 20mm graded stone aggregate as in floor and laying 15mm screed bed of cement mortar (1:4) with water proofing compound, finished even and smooth without using extra cement cement complete all as specified and as directed by Engineer-in-charge.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic tiles (coloured) 450mm x 350mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in two layer on fair faces of brick masonry or concrete surfaces of walls consisting of 1st layer of 10mm thick plaster in CM 1:6 and 2nd layer (setting coat or top layer) of 5 mm thick plaster in CM 1:4 mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished fair & even, complete, all as specified. Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L for 10mm thick rendering in cement mortar (1:4) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick rendering in cement mortar (1:6) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 5mm thick rendering in cement mortar (1:3) on brick or concrete surface of ceiling, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of exterior Acrylic emulsion paint over and including one coat of primer as per manufacturer instruction including cleaning window glasses, joinery, electric fitting, wiring etc of drops and splashes and cleaning permise clean and tidy complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of steel surface already treated with primer over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
S&F 4mm thick figured glass pin head type and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 20 mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 20mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge. Note :- Excavation and earthwork shall be measured and paid for separately under respective items of BOQ.
S&F 25mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge. Note :- Excavation and earthwork shall be measured and paid for separately under respective items of BOQ.
M&L cutting existing GI water main pipe line in position of 40mm bore and making connection of new pipe line of 40mm bore with & including insertion of new GI Tee of size 40mm x 40mm x 25mm including excavation & earth work in any type of soil complete all as directed.
S&F gun metal globe or gate valve 20mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F gun metal globe or gate valve 25mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union with shower arm 15mm size, 195mm long iwht bend of 45 degree with flange complete all as specified and directed by Engineer-in-charge.
S&F brass chromium plated tubular towel rail 20mm dia; 'D' type, 600mm long between flanges fixed to plug with chromium plated brass screws including wooden or plastic cleat complete all as specified and directed by Engineer-in-Charge.
S&F grating doom 100mm dia of stainless steel with waste hole (minimum weight 25 grams) complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tank ISI Marked (cylindrical vertical double layered with closed top) hoisted and fixed in position of capacity 1000 litres including ball brass valve, high pressure with polythene float and flynut screwed for 20 mm dia GI pipe, 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 1.50 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 1.30 metre long fitted with tee at the end of air vent pipe (All GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F 15mm dia stop cock cast copper alloy, fancy type with, chromium plated long shank and cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F 15mm bore angle valve, cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
S&F vitreous china wash basin white, flat back of size 550x400mm including including a pair of cast iron brackets embedded in PCC 1:3:6 type C-1 blocks of size 10 x 7.5 x15 cm with & including 32 mm dia PVC waste pipe, 32mm dia PTMT waste coupling half or full thread (minimum wt 45 grms) flange end bedded in red lead cement & other end fixed to waste pipe and including brass chromium plated fancy type pillar tap, screwed suitable for iron pipes of 15mm bore complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device and jet spray complete all as specified & as directed by Engineer-in-charge.
S&F 10 litre capacity PVC valveless symphonic action type low level flushing cistern (ISI marked) including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified and directed by Engineer-in-charge.
S&F vitreous china half stall type, flat back urinal of size 390 x 375 x 590mm, white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including PTMT grating and union for discharge pipe, chromium plated urinal spreader including waste pipe of polythelene of low or high density or PVC 32mm dia complete all as specified and directed by Engineer-in-charge.
S&F chromium plated Soap dish holder including chromium plated brass screws and plastic cleats complete all as specified & directed by Engineer-in-Charge. Make : Jaquar cat Part No ACN-1131N or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length jointed with adhesive fixed to walls fixed with and including requisite Number of clamps made out of flat iron 25x4mm complete all as specified and as directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) pipes single socketed in any length jointed with adhesive fixed to walls fixed with and including requisite Number of clamps made out of flat iron 25x4mm complete all as specified and as directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) bends any radius jointed with adhesive complete all as specified and as directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) junction, double (double T) equal or unequal complete all as specified and directed by Engineer-in-Charge
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-in-Charge"
Supplying, laying, jointing and testing 200 mm bore reinforced cement concrete pipes, class NP-2 including coller set in cement mortar (1: 1) complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in bed to drain pipe including forming cradles for 200mm dia of pipes and tested complete complete all as specified and directed by Engineer-in-Charge.
M&L for cutting into existing manhole/Septic tank/Soak well for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1, smooth finished and reforming benching as required for 225mm bore pipe complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 95 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 95 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per Srl item No. 95 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 6 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F flush mounting factory made SPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507610 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408618 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F LED lamp minimum 3 star rated 12W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : Morethan 80
S&F Energy efficient decorative ultra slim, prewired, lumiline 18 watt LED light fitting (Day cool light), batten type with drive & polycarbonate housing including tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS18WLED865 SPCWH / Syska Cat part No SSK-RA1801 Wipro cat part No LL20-221-XXX-65-NE / Philips cat part No 61009 BL CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim prewired 9 / 10watt (600mm length) LED light fitting (Mirror light) (Day cool light), surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver and all accessories fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS9WLED865 SPCWH / Syska cat part No SSK-T5T-9W / Crompton cat part No LCTLN-10-CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F exhaust fan 300 mm sweep,900 RPM trans air, with louver shutter suitable for operation on 230 volts, single phase , AC and connecting up including 2 core,1.0 sqmm PVC insulated & PVC sheathed copper conductor flexible cable drawn in flexible conduit complete all as specified & directed by Engr-in-charge. Make :- Havells Model No Terbo Jet SP or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc including grouting 4 Nos bolts in PCC (1:2:4) block in wall and making good the disturbed surfaces matching with existing including making connection to elerctric supply complete all as specified and directed by the engr-in-charge.
S&F Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engr-in-charge. Notes :- (i) GI wire upto DBs or upto earth test point is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for RCC cover shall be 1 KG.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 16 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account..
S.K BUILDERS AND ENGINEERS
SAHIL BUILDERS
Gupta Suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .