RequiredExperience with Government Bid to RA enabled No Pabx System-EPABX ( 1 set ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) EXTENSION AND TRUNK/JUNCTION EPABX system Implementation Tech nology/Architecture Hybrid ( Microprocessor based also supporting SIP extension ) Hybrid ( Microprocessor based also supporting SIP extension ) Number of Analogue Extensions/FXS Ports 0 24
Required48
Required64
Required96
Required128
Required160
Required192
Required224
Required256
Required320
Required384
Required448
Required576
Required704
Required832
Required960
Required1088
Required1600
Required2112
Required2624
Required3136
Required3648
Required4160
Required4672
Required0 Or higher 1/11 Expandable Upto (TDM/FSX Ports) 6000 6000 Number of Digital Extensions 8 8 Number of Analogue Junction/FXO ports 8 8 Number of SIP Extensions 128 128 SIP Extensions expandable upto 256 256 Number of SIP Trunks 32 32 MAIN DISTRIBUTION FRAME(MDF) MDF(Number of pair) 100 100 Integrated Protection Module(IPM) Yes Yes If YES
Requirednumber of Integrated Protection Module(IPMs) 100 100 CARDS CARDS Type of Cards Supported BRI
RequiredPRI
RequiredE1
RequiredE&M
RequiredRadio Interface
RequiredGSM BRI
RequiredPRI
RequiredE1
RequiredE&M
RequiredRadio Interface
RequiredGSM Number of Ports per Card Supported 4 4 GATEWAYS Type of Gateways Supported Universal Gateway
RequiredSIP
RequiredFXO
RequiredFXS
RequiredPRI
RequiredRadio
RequiredGSM
RequiredE1 * Number of Ports per Gateway Supported 4 * CONSOLE Type of Operator Console Server Based Server Based Number of Operator Console 1 1 SERVER SPECIFICATIONS REQUIREMENTS Total Number of Servers Included in the Supply 1 1 "Number of Hot Standby Servers out of Total Servers
Requiredincluded in the Scope of Supply" 0 * Server Form Factor Rack * Rack Size (RU)/Space Required for each Server 2 * Processor Make NA * Processor Configuration - * 2/11 & Description Total Number of processor NA NA Number of Redundant Processors Included in the Total Number of Processor NA NA Number of Cores per Processor NA NA Type of RAM NA * RAM Size (in GB) NA NA T ype of Hard Disk Drive NA * Capacity of Hard Disk Drive (in TB) NA NA Hot Swap Components Power Supply Unit
RequiredFans
RequiredHDD
RequiredNA Power Supply Unit
RequiredFans
RequiredHDD
RequiredNA Network Interface Integrated Dual Gigabit(auto) Ethernet supporting IPv4 and IPv 6
RequiredUSB
RequiredHDMI
RequiredVGA
RequiredWiFi * SOFTWARES Applcation Software Type/Capabilities Call Server Software
RequiredHot StandBy Server Software
RequiredUnified Communication Server Software
RequiredNetwork Management Server Software
RequiredNA Call Server Software
RequiredHot StandBy Server Software
RequiredUnified Communication Server Software
RequiredNetwork Management Server Software
RequiredNA Type of Licence Perpetual Perpetual Name of Softwares - * Name of the OEM - * OEM Model/Part Number - * Software Description - * Software Version - * Date of Launch of Version - * Free supports/updates during validity of license YES * SOFTWARE FEATURES Analog Extention/FXS ( If Yes
RequiredNumber of Software/Licences shall be Commensurate YES YES 3/11 Equal to the Number of Analog Extension/FXS Offered under ""EXTENSION AND TRUNK/JUNCTION"" ) "Digital Extension ( If Yes
RequiredNumber of Software/Licences shall be Commensurate Equal to the Number of Digital Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES "Analog Junction/FXO ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of Analog Junction/FXO Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES "SIP extension ( If Yes
RequiredNumber of Software/Licences shall be Commensurate Equal to the Number of SIP Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES "SIP trunk ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES "PRI Trunk ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of PRI Trunk Offered YES YES 4/11 under ""EXTENSION AND TRUNK JUNCTION"" )" "Radio Interface ( If Yes
RequiredNumber of Software/Licences shall be Commensurate Equal to the Number of Radio Interface Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES "GSM ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of GSM Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES "E1 Trunk ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of E1 Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES "E&M ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of E&M Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES GENERAL FEATURES of EPABX SYSTEM Number of Conference Participants Supported 32 32 Number of Direct Station Selection Keys per Console 16 * Number of Media Channel/Ports Supported 32 32 Number of IP-TDM Concurrent Calls(2 128 128 5/11 users per call) Supported Call Buffer Memory System Yes Yes If Call Buffer Memory Available
RequiredNumber of Records 2000 2000 Hot Standby Redundant CPU Yes Yes If YES
RequiredNumber of Hot Standby CPU Cards 2 2 Hot Standby Redundant PSU (Power Supply Unit) Yes Yes If YES
RequiredNumber of Hot Standby Redundant PSU Cards 1 1 Inbuilt Voice Mail for EPABX System Yes Yes If Voice Mail Available
RequiredNumber of Voice Mail Channels 16 16 Available for Voice Mail
RequiredNumber of Hours of Recording 512 512 Auto Attendant Facility Yes * If Available
RequiredNumber of Auto Attendant Channels 8 * ASMDR/CDR Yes Yes Voice Logger Inbuilt Inbuilt If YES
RequiredNumber of Simultaneous Calls that can be Recorded in Voice Logger 8 * Security Feature(for server based) NA * Supported Functionalities (for server based) UCS
RequiredNA * Supported Codecs G711
RequiredG729
RequiredG723
RequiredH264 * Any other features - * SYSTEM/EXTENSION/AT TENDANT CONSOLE FEATURES System Features Automatic Route Selection facility
RequiredDID facility(Direct inward Automatic Route Selection facility
RequiredDID facility(Direct inward 6/11 dialing)
RequiredDOD facility(Direct outward dialing)
RequiredDISA facility(Direct inward station access)
RequiredDOSA facility(Direct outwards station access)
RequiredMulti Level Voice DISA facility
RequiredPrivacy of Call
RequiredFacility for connecting recorded voice answering
RequiredASMD R/CDR
RequiredProgrammable class of service for (STD/ISD/LOCAL) dialing as per need
RequiredCaller ID information for both internal and external callers (over Analogue
RequiredISDN PRI)
Requiredunique authorization codes for every users
RequiredAutomatic call back
RequiredCall waiting
RequiredMusic-on-hold facility
RequiredCall budgeting
RequiredLeast cost routing
RequiredMix-mode dialing
RequiredProvision for remote logins
RequiredInteractive Voice Response System(IVRS)
RequiredExtensio n to Extension dialing dialing)
RequiredDOD facility(Direct outward dialing)
RequiredDISA facility(Direct inward station access)
RequiredDOSA facility(Direct outwards station access)
RequiredMulti Level Voice DISA facility
RequiredPrivacy of Call
RequiredFacility for connecting recorded voice answering
RequiredASMDR/CDR
RequiredProgrammable class of service for (STD/ISD/LOCAL) dialing as per need
RequiredCaller ID information for both internal and external callers (over Analogue
RequiredISDN PRI)
Requiredunique authorization codes for every users
RequiredAutomatic call back
RequiredCall waiting
RequiredMusic-on- hold facility
RequiredCall budgeting
RequiredLeast cost routing
RequiredMix-mode dialing
RequiredProvision for remote logins
RequiredInteractive Voice Response System(IVRS)
RequiredExtension to Extension dialing Extension Features Call forwarding
RequiredConsultatio n Hold
RequiredBrokers Call
RequiredAutomatic call transfer
RequiredConference call
RequiredCall pick up
RequiredCall re routing
RequiredAuto call disconnection
RequiredDynamic STD Lock
RequiredPaging on key phone
RequiredBackground music
RequiredPassword control
RequiredVirtual Telephony
RequiredHowler Tone
RequiredCall parking
RequiredAuto answer/Auto off
RequiredEmergency call facili ty
RequiredMissed/Dialed/Receiv ed Call Lists
RequiredLast Caller Call back
RequiredPassword display suppression
RequiredPersonal Identification Call forwarding
RequiredConsultation Hold
RequiredBrokers Call
RequiredAutomatic call transfer
RequiredConference call
RequiredCall pick up
RequiredCall re routing
RequiredAuto call disconnection
RequiredDynamic STD Lock
RequiredPaging on key phone
RequiredBackground music
RequiredPassword control
RequiredVirtual Telephony
RequiredHowler Tone
RequiredCall parking
RequiredAuto answer/Auto off
RequiredEmergency call facility
RequiredMissed/Dialed/Received Call Lists
RequiredLast Caller Call back
RequiredPassword display suppression
RequiredPersonal Identification Number
RequiredHotline
RequiredPreset 7/11 Number
RequiredHotline
RequiredPreset Conference Calls
RequiredDirect Call billing in rupees
RequiredCall billing printout
RequiredCalling line ide ntification(CLI)
RequiredRemote Maintenance
RequiredOther Extension features Conference Calls
RequiredDirect Call billing in rupees
RequiredCall billing printout
RequiredCalling line identification(CLI)
RequiredRemote Maintenance
RequiredOther Extension features Attendant Console Features Answering an incoming call
RequiredCall queuing
RequiredSerial Call
RequiredCall waiting display
RequiredAutomatic Call Distribution
RequiredCall Hold
RequiredTrunk offering
RequiredNight service
RequiredHead phone connectivity
RequiredOther Attendants console Features Answering an incoming call
RequiredCall queuing
RequiredSerial Call
RequiredCall waiting display
RequiredAutomatic Call Distribution
RequiredCall Hold
RequiredTrunk offering
RequiredNight service
RequiredHead phone connectivity
RequiredOther Attendants console Features Voice Prompts and Announcement Yes * If yes
RequiredNumber of Levels of IVRS 2 2 POWER SOURCE Supply Voltage 48V DC 48V DC Provision for Inbuilt Battery Charging Arrangement for providing Battery Backup NO * FCBC NO NO If YES
Requiredminimum current Rating of FCBC at chrging voltage of 48V (Ampere) NA NA Protection against over current and accidental reversal of polarity on the input side and against over current
Requiredover voltage on the output side YES * OPERATING CONDITIONS Minimum Operating Temperature (Degree C) 0 0.0 Maximum Operating Temperature (Degree C) 45 45.0 Operating Humidity (RH) (% ) 80 80 TEST REPORT DETAILS TEC approval as per YES * 8/11 AND TESTS the latest TEC specifications TEC approval Certificate number - * Availability of the test report from Central Government/NABL ILAC acredited lab to prove conformity to the specification including Environmental Test Sequence Yes * Test Report Number and date (not a part of biddable parameter) - * Name and Address of the Test lab(not a part of biddable parameter) - * Test reports consist of verification of all the features & functional parameters & environmental tests Yes * conformity to Dry Heat for 16 hours at maximum specified temperature degree C in accordance with IS:9000/part-3/sectio n-5/1977 latest Yes Yes conformity to Cold Test for 4 hours at minimum specified temperature degree C in accordance with IS:9000/part-2/sectio n-4/1977 latest Yes Yes conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:9000/part-5/s ection-1/1991 latest Yes Yes INSTALLATION AND MAINTENANCE Installation and Commissioning With With Chemical Earthing to achieve resistance < 2ohm Yes Yes Recommendation Information regarding - * 9/11 Supporting Hardware Required to meet the Performance Capabilities of the System OPERATION & MAINTENANCE SUPPORT The scope of supply include one set of operation and maintenance manual for each equipment YES * Operation & Maintenance terminal Provided * Training provided to buyers Yes Yes If YES
RequiredDetails of training On site training for 3 days On site training for 3 days Packing List - * SERVICES Warranty 1 1
Required2
Required3
Required4
Required5
Required6
Required7
Required8
Required9
Required10 Or higher Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System
Required- * Compliance to STC of the Product Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents