Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹7.7 L (6.19%)Admitted-Finance 245 2 RAJPUR ROAD OPPOSITE HOTEL MADHUBAN DEHRADUN | ₹1.3 Cr+₹7.7 L (6.19%) | L2 | Admitted-Finance |
| 3 | L3₹1.4 Cr+₹13.5 L (10.9%)Admitted-Finance 1ST FLOOR HRECF OFFICE NEAR JNV SCHOOL MIAN GATE TIA RAY RONG CHOGLAMSAR LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | ₹1.4 Cr+₹13.5 L (10.9%) | L3 | Admitted-Finance |
| 4 | L4₹1.4 Cr+₹16.0 L (12.9%)Admitted-Finance | ₹1.4 Cr+₹16.0 L (12.9%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected as TDR is not acceptable as per SBD clause No. 7(2) |
| Sl No | Description | Qty | Unit | MODERN ELECTRIC CO L2 | TL CONSTUCTION COMPANY L1 | HIMALAYAN RENEWABLE ENERGY AND CONSTRUCTION FIRM (HRECF) L3 | M/S ENRON GROUP OF ENGINEERS L4 |
|---|---|---|---|---|---|---|---|
| 1.00DT (Supply Part) | |||||||
| 1.01 | Compact Substation with single panel VCB 630A 11KV + 1250KVA Oltc Transformer with 3 way Auto RMU RTCC panel +2000 Amps ACB with extended busbar for spare connections and outgoing 4 Nos. of 630A MCCB. HT meter should be incorporated on outgoing side of RMU | 1 | No. | 57,50,000 ₹57,50,000 Lowest | 65,00,000 ₹65,00,000 | 66,00,000 ₹66,00,000 | 78,00,000 ₹78,00,000 |
| 1.02 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 2 | Set | 5,950 ₹11,900 | 12,000 ₹24,000 | 11,010 ₹22,020 | 5,780 ₹11,560 Lowest |
| 1.03 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type | 2 | Set | 10,500 ₹21,000 Lowest | 14,000 ₹28,000 | 14,000 ₹28,000 | 12,000 ₹24,000 |
| 1.04 | 11 kV Horn Gap Fuse Set 3 Phase 200A | 2 | Set | 4,650 ₹9,300 Lowest | 5,500 ₹11,000 | 9,000 ₹18,000 | 4,950 ₹9,900 |
| 1.05 | 11 KV Single core 185 sqmm Al conductot wounder wire GI armoured XLPE FRLS | 200 | Mtr | 440 ₹88,000 | 360 ₹72,000 Lowest | 900 ₹1,80,000 | 603 ₹1,20,600 |
| 1.06 | 9 Mtr. Long Pole,ST-410 SP33) | 2 | Nos | 14,861 ₹29,722 Lowest | 24,000 ₹48,000 | 21,000 ₹42,000 | 18,750 ₹37,500 |
| 1.07 | 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm | 12 | Nos | 450 ₹5,400 Lowest | 700 ₹8,400 | 550 ₹6,600 | 765 ₹9,180 |
| 1.08 | GI Channel/Angle/Flat of sizes including clamps | 600 | Kgs | 115 ₹69,000 Lowest | 149 ₹89,400 | 200 ₹1,20,000 | 200 ₹1,20,000 |
| 1.09 | Galvinized Nuts and Bolts. | 16 | Kgs | 155 ₹2,480 | 149 ₹2,384 Lowest | 200 ₹3,200 | 200 ₹3,200 |
Tender Value
₹5,000
EMD Value
₹4.3 L
Closing Date
22 Sept 2025, 2:00 pmClosed
Superintending Engineer
PDD Choglamsar
same as above
2025_PDNRE_17463_1
e-NIT No. 130 of ED Leh of 2025-26 dated 10-09-2025
Open Tender
Electrical Works
Turn-key
90 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,000
Payable To Executive Engineer
₹4.3 L
10 Oct 2025
10 Sept 2025
23 Sept 2025
10 Sept 2025
22 Sept 2025
11 Sept 2025
Amount
DT (Supply Part)
Compact Substation with single panel VCB 630A 11KV + 1250KVA Oltc Transformer with 3 way Auto RMU RTCC panel +2000 Amps ACB with extended busbar for spare connections and outgoing 4 Nos. of 630A MCCB. HT meter should be incorporated on outgoing side of RMU
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
11 KV Single core 185 sqmm Al conductot wounder wire GI armoured XLPE FRLS
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Supply of Chemical earthing complete with all clamps, nuts & bolts, washers etc to be used to achieve the recommended earth resistance value for high resistivity locations.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry Itemss like aluminium lugs, Jumpers, binding Tape
RCC Tranformer bed for compact 1250KVA Sub-station
Transformer Fencing
33 KV Indoor type Touch proof cable Kit
33KV Outdoor type cable Kits
DT (Installation/Testing/Commissioning Part)
Compact Substation with single panel VCB 630A 11KV + 1250KVA Oltc Transformer with 3 way Auto RMU RTCC panel +2000 Amps ACB with extended busbar for spare connections and outgoing 4 Nos. of 630A MCCB. HT meter should be incorporated on outgoing side of RMU
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
11 KV Single core 185 sqmm Al conductot wounder wire GI armoured XLPE FRLS
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Supply of Chemical earthing complete with all clamps, nuts & bolts, washers etc to be used to achieve the recommended earth resistance value for high resistivity locations.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry Itemss like aluminium lugs, Jumpers, binding Tape
RCC Tranformer bed for compact 1250KVA Sub-station
Transformer Fencing
33 KV Indoor type Touch proof cable Kit
33KV Outdoor type cable Kits
HTLine (Supply Part)
11Mtr. Long Pole ( ST-410 SP56) (Flanged Type)
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
GI Channel X-Arm 1600mm long including clamps and braces (75x40x6mm) GI Channel (weight per channel = 11.42kg, back clamp for cantilever 50x8mm, 365mm long = 1.15kg Total weight = 12.57kg/Channel +Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in kgs (weight = 10.21kg, Guy clamp for cantilever 50x8mm, 300mm long = 0.9kg, Total weight = 11.11kg) Total weight = 23.68Kg
GI Canel x-arm including clamp and bress for DP (80kg/DP)
50 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Silicon Cover
Cement bottoming 1:2:4 mix as per REC standards ..5cum /pole
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
HT Line (Installation/Testing/Commissioning Part)
11Mtr. Long Pole ( ST-410 SP56) (Flanged Type)
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
GI Channel X-Arm 1600mm long including clamps and braces (75x40x6mm) GI Channel (weight per channel = 11.42kg, back clamp for cantilever 50x8mm, 365mm long = 1.15kg Total weight = 12.57kg/Channel +Clamp) GI Angle 65x65x6mm, 1760mm long including clamps and braces in kgs (weight = 10.21kg, Guy clamp for cantilever 50x8mm, 300mm long = 0.9kg, Total weight = 11.11kg) Total weight = 23.68Kg
GI Chanel x-arm including clamp and bress for DP (80kg/DP)
50 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV, 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Silicon Cover
Cement bottoming 1:2:4 mix as per REC standards ..5cum /pole
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
LT Line (Supply Part)
Supply of 415V, 3-phase, 4 wire, 50 Hz, 35 KA/1Sec LT Feeder Pillars comprising of FRP enclosure with combination of Incoming and Outgoing feeder circuits as per the rating & configuartion given in the respective SLD's & technical specification with Microprocessor based 4-pole, MCCB of various ratings as incomer & specified rating outgoings with 4-pole, MCCB/4-P MCB's, as per the technical specifications/SLD for different Transformer capacities, CT Operated TVM, metering as per technical specifucations, suppot channel, rain sheds, complete in all respect. The OGA & Scheme of the panel shall be as per the approved drawing. The LT feeder pillar shall be for outdoor installation and shall have IP55 protection glass. The LT Feeder panel shall be supplied in line with the tachnical specification as per the following types. Incomer 400A and outgoing 4 No.s of 250Amp. LT Panel must be comprised with VMC Relay, auto changeover for DG supply, indication lamp, volt meter, Ammeter etc.
3.5C x 185sqmm AL conductor XLPE (E) armoured cable
Supply of termination of 3.5C x185sqmm
Supply of Chemical earthing complete with all clamps, nuts & bolts, washers etc to be used to achieve the recommended earth resistance value for high resistivity locations.
Supply of GI Flat 25x6mm for earthing of service pillar
RCC foundation for main LT Feeder Pillar
Supply of 160mm HDPE DWC Pipe
LT Line (Installation/Testing/Commissioning Part)
Supply of 415V, 3-phase, 4 wire, 50 Hz, 35 KA/1Sec LT Feeder Pillars comprising of FRP enclosure with combination of Incoming and Outgoing feeder circuits as per the rating & configuartion given in the respective SLD's & technical specification with Microprocessor based 4-pole, MCCB of various ratings as incomer & specified rating outgoings with 4-pole, MCCB/4-P MCB's, as per the technical specifications/SLD for different Transformer capacities, CT Operated TVM, metering as per technical specifucations, suppot channel, rain sheds, complete in all respect. The OGA & Scheme of the panel shall be as per the approved drawing. The LT feeder pillar shall be for outdoor installation and shall have IP55 protection glass. The LT Feeder panel shall be supplied in line with the tachnical specification as per the following types. Incomer 400A and outgoing 4 No.s of 250Amp. LT Panel must be comprised with VMC Relay, auto changeover for DG supply, indication lamp, volt meter, Ammeter etc.
3.5C x 185sqmm AL conductor XLPE (E) armoured cable
Supply of termination of 3.5C x185sqmm
Supply of Chemical earthing complete with all clamps, nuts & bolts, washers etc to be used to achieve the recommended earth resistance value for high resistivity locations.
Supply of GI Flat 25x6mm for earthing of service pillar
RCC foundation for main LT Feeder Pillar
Supply of 160mm HDPE DWC Pipe
MODERN ELECTRIC CO (BID ID -170695)
HIMALAYAN RENEWABLE ENERGY AND CONSTRUCTION FIRM (HRECF) (BID ID -170872)
M/S ENRON GROUP OF ENGINEERS (BID ID -170919)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .