Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 CrAccepted-Finance | ₹36.2 Cr | L1 | Accepted-Finance Accepted |
| 2 | L2₹37.9 CrAccepted-Finance CS 51 ANSAL PLAZA 1 FLOOR SEC 1 VAISHALI GHAZIABAD UTTAR PRADESH 201 010 | ₹37.9 Cr | L2 | Accepted-Finance Accepted |
| 3 | Not Admitted-Fee/PreQual/Technical 106 NEHRU NAGAR ROORKEE UK | CHAMPAWAT | UTTARAKHAND | 262309 | - | - | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹37.2 Cr
EMD Value
₹74.4 L
Closing Date
13 Jul 2020, 6:00 pmClosed
Chief Executive Officer, ASCL
ASCL Office, Ajmer
as per RFP
2020_ASCL_186038_1
ASCL/NIT43/2020-21/978_2
Open Tender
Civil Works
730 days
Ajmer
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Yes
CEO, ASCL
₹74.4 L
ASCL Office, Ajmer
31 May 2022
11 Jun 2020
15 Jul 2020
11 Jun 2020
13 Jul 2020
11 Jun 2020
17 Jun 2020
Amount
Surveillance Cameras
Supply, Installation, Integration, Testing, & Commissioning of 4 MP Fixed Lens Network IR Bullet Camera with SD Card as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support.
Supply, Installation, Integration, Testing, & Commissioning of 4 MP Vari-focal Motorized Bullet camera with SD card as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support.
Supply, Installation, Integration, Testing, & Commissioning of 4 MP Fixed Lens Network IR Dome Camera with SD Card as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support.
Supply, Installation, Integration, Testing, & Commissioning of 64 Channel H.265 Network Video Recorder upto 8 SATA III as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support.
Supply, Installation, Integration, Testing, & Commissioning of 16 Port Gigabit PoE Switch as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support.
Supply, Installation, Integration, Testing, & Commissioning of 8 Port Gigabit POE Network Switch as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support.
Supply, Installation, Integration, Testing, & Commissioning of 6 TB HDD for Video Recorder as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support.
Supply, Installation, Integration, Testing, & Commissioning of 43"Led Monitor as per requirement, scope of work, technical specification & complete in all respect as per the satisfaction of Engineer in Charge with 3 years onsite OEM support.
Ruidp item No. 61.2 : Supply , Drawing and Testing of 4 pair, 100 ohm, 24 AWG UTP Cat 6 Cable as per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to Information outlets and Patch Panels with ferruling at both ends for identification with necessorry tools for punching, stripping, crimpping and testing required .
Ekectrical Work
Providing & Fixing for 3 no. Passenger elevator to be furnished and erected in accordance with the following details: (Including 1 year warranty) LOAD: 884 Kg (08 Pass.) TRAVEL: G+8 = 09 stop Control & operation: microprocessor base control systems+V3F STOP & openings: 09 Stops & 03 Opening. CAR DESIGN : S.S Cabin and false Ceiling with multi reflecting in direct lighting arrangement centrally placed motor type Blower with circular air diverter, integral car operating panel luminous button & PVC flooring Car door : S.S automatic centre opening door. Clear Inside shaft(Required) = 1500mm *2450 mm Clear Inside shaft(Available) = 2000 mm * 4000 mm Machine Position: Directly placed above the top of the hoist way Special Features : a) Call Register type Micro push button, b) Blower switch in Car (automatic). c) Fireman Switch at Main Landing. d) Emergency Alarm.(e) VV3F (f) Motor Sharp 7.7 kw (g) Fully Collective control-Simplex (h) Speech System. (I) ARD System Make with schindler/Otis/escon or equivalaent
Heating, Ventilation, and Air Conditioning System
Supply of variable refrigerant Flow ( VRF) system, suitableMaximumtemperature comprising of the following and complete as per Combination of hermetically sealed Scroll Inverter Compressor suitable for operation on R-410A complete with high/low pressure cut-outs, oil pressure failure switch, fan motor, safety thermostat, over current relay, fusible plugs, fuses etc. and suitable for operation on 380-440V, 3 phase, 50 Hz A.C. supply. Matching air cooled condenser with copper tubes and aluminum fins duly covered by anti-corrosion and ydrophilic resin film. Oil separator suitable for the long refrigerant piping. Lot - Accumulator, liquid and gas shut-off valves and solenoid valves/modulation valve with fittings to interconnect compressor, condenser and evaporator coils. Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger. Wall thickness, supports spacing, jointing, testing of copper pipes as per ASHRAE/ISHRAENORMS. 1 No Each for suction line , 1 no each for liquid line ( = 1set ) if not included in machine. Providing and fixing ac drain rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mmthick closed cell nitrile rubber insulation. Acoustic Insulation Supply and installation of 10mm thick, Open Cell, Nitrile Rubber acoustic insulation of density 140-180Kg/m3, with Anti microbial properties as per specifications. SITC of Site Fecticated ducting made from GSS of class VIII & fabricated as per IS:655 and as per approved drawings & designs including the cost of hangers, supports , angle , expansion fasteners , closed cell neoprene gasket T&P etc. as required of following gauge: Thermal Insulation (Internal ducting): Supply and installation of 19mm thick, closed cell elastomeric nitrile rubber for supply air duct , complete with mechanical/UV protection and duct supports as per specifications Complete supply and installation, testing, e.t.c in each and every spects.
Outdoor Units-Heat Pump (R410A) ODU - 12HP
Outdoor Units-Heat Pump (R410A) ODU - 14HP
Outdoor Units-Heat Pump (R410A) ODU - 16HP
Outdoor Units-Heat Pump (R410A) ODU - 18HP
Outdoor Units-Heat Pump (R410A) ODU - 20HP
Indoor Units Concealed Type 5.6 TR.
Indoor Units Concealed Type 6.6 TR.
Indoor Units Concealed Type 8.25 TR.
Indoor Units 4-Way Cassette 2.08 TR.
Indoor Units 4-Way Cassette 2.64 TR.
Indoor Units 4-Way Cassette 3.3 TR.
Indoor Units Hi-Wall 0.8 TR.
Indoor Units Hi-Wall 1.05 TR.
Indoor Units Hi-Wall 1.3 TR.
Indoor Units Hi-Wall 1.65 TR.
REFNET JOINTS
REMOTE CONTROLLER
BHF JOINT
Supply of VRV airconditioning system (equipments) comprising of following Outdoor Units-Heat Pump (R410A), ODU - 20HP Heating & Cooling
Indoor Units TFA 6.6 Tr
Indoor Units Copper Piping
Supply of VRV airconditioning system (equipments) comprising of following Drain 1 Lot
Supply of VRV airconditioning system (equipments) comprising of following CABLE
Supply of VRV airconditioning system (equipments) comprising of following GI SHEET 24G
Supply of VRV airconditioning system (equipments) comprising of following GI SHEET 22G
Supply of VRV airconditioning system (equipments) comprising of following CANVAS
Supply of VRV airconditioning system (equipments) comprising of following INSULATION
Supply of VRV airconditioning system (equipments) comprising of following ACCOUSTIC
Supply of VRV airconditioning system (equipments) comprising of following GRILL
Supply of VRV airconditioning system (equipments) comprising of following REFNET JOINTS
Supply of VRV airconditioning system (equipments) comprising of following REMOTE CONTROLLER
Civil Work
Providing and fixing C.P. brass bib cock with automatic sensor discharge system
Medical Gas Pipeline System
Supply, Installation, Testing and Commissioning of fully Oxygen Manifold as per technical specifications. The cylinders shall not be included in the quoted price. Make- Aktiv/PSPL/NSP 15+15 Cylinder
supply, Installation testing and commissioning of Fully Automatic Oxygen Control System as technical specifications. as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed.Make- Beacon Medaes/ Delta P/ Greggerson
Supply, Installation, testing and commissioning of Emergency Oxygen Supply System as per technical specifications. The cylinders shall not be included in the quoted price. Make- Aktiv/PSPL/NSP, 5+5 Cylinder
Supply installation, testing and commissioning of oxygen flow meter with humidifier bottle 0-15Litres, and CE marked under Medical Directive 93/42/EEC Make- Aktiv/PSPL/NSP
Supply,Installation, testing and commissioning of Gas outlet points with Probe for Oxygen, Nitrous Oxide, Air, & Vacuum as per technical specification as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed.Make- Beacon Medaes/ Delta P/ Greggerson, for Oxygen
Supply,Installation, testing and commissioning of Gas outlet points with Probe for Oxygen, Nitrous Oxide, Air, & Vacuum as per technical specification as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed.Make- Beacon Medaes/ Delta P/ Greggerson, for Compressed Air ( 4 Bar )
Supply,Installation, testing and commissioning of Gas outlet points with Probe for Oxygen, Nitrous Oxide, Air, & Vacuum as per technical specification as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed.Make- Beacon Medaes/ Delta P/ Greggerson, For Vacuum
Supply installation testing and commissioning of High pressure tubes duly colour coded for oxygen , Nitrous Oxide Compressed air and vacuum as per technical specification and as per HTM/ ISO 7396/ NFPA-99 Standard and CE marked.Make- Aktiv/PSPL/NSP
Supply installation testing and commissioning of Low pressure tubes duly colour coded for vacuum as per technical specification and as per HTM/ ISO 7396/ NFPA-99 Standard and CE marked.Make- Aktiv/PSPL/NSP
Supply,Instllation testing and commissiong of Medical Grade Copper Piping BSEN : 13348 Lloyd's Certified as per technical specification Make- Rajo/ Mehta Tube, 76mm ODX1.5mm thick
Supply,Instllation testing and commissiong of Medical Grade Copper Piping BSEN : 13348 Lloyd's Certified as per technical specification Make- Rajo/ Mehta Tube, 54mmODX1.2mm thick
Supply,Instllation testing and commissiong of Medical Grade Copper Piping BSEN : 13348 Lloyd's Certified as per technical specification Make- Rajo/ Mehta Tube, 42mm ODX1.2mm thick
Supply,Instllation testing and commissiong of Medical Grade Copper Piping BSEN : 13348 Lloyd's Certified as per technical specification Make- Rajo/ Mehta Tube,28mmODX 0.9mm thick
Supply,Instllation testing and commissiong of Medical Grade Copper Piping BSEN : 13348 Lloyd's Certified as per technical specification Make- Rajo/ Mehta Tube, 22mmODX 0.9mm thick
Supply,Instllation testing and commissiong of Medical Grade Copper Piping BSEN : 13348 Lloyd's Certified as per technical specification Make- Rajo/ Mehta Tube, 15mm ODX0.9mm thick
Supply,Instllation testing and commissiong of Medical Grade Copper Piping BSEN : 13348 Lloyd's Certified as per technical specification Make- Rajo/ Mehta Tube, 12mm ODX0.7mm thick
Supply, installation, testing and commissioning of Medical Air System complete with all aspects(Make- Anesta Iwata/IR/ FSCurtis)
Supply, installation, testing and commissioning of Medical Vacuum System complete with all aspects(Make- Anesta Iwata/IR/ FSCurtis)
Ward Vacuum unit complete with vacuum regulator, jar for collection of 1000 ml and bracket for collection bottle. CE marked under Medical Directive 93/42/EEC Make- Aktiv/PSPL/NSP
Supply, Installation, testing and commissioning of Area Valve Service Unit (Alarms + Valve Box) as per Technical Specification. as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed.The Isolation Valves used for the shall be degreased for oxygen use Make- Beacon Medaes/ Delta P/ Greggerson 2 Gas Services
Supply, Installation, testing and commissioning of Area Valve Service Unit (Alarms + Valve Box) as per Technical Specification. as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed.The Isolation Valves used for the shall be degreased for oxygen use Make- Beacon Medaes/ Delta P/ Greggerson 3 Gas Services
Supply, Installation, testing and commissioning of Area Valve Service Unit (Alarms + Valve Box) as per Technical Specification. as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed.The Isolation Valves used for the shall be degreased for oxygen use Make- Beacon Medaes/ Delta P/ Greggerson 4 Gas Services
Supply, Installation, testing and commissioning of Area Valve Service Unit (Alarms + Valve Box) as per Technical Specification. as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed.The Isolation Valves used for the shall be degreased for oxygen use Make- Beacon Medaes/ Delta P/ Greggerson 5 Gas Services
Supply, Installation, testing and commissioning of Area Valve Service Unit (Alarms + Valve Box) as per Technical Specification. as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed.The Isolation Valves used for the shall be degreased for oxygen use Make- Beacon Medaes/ Delta P/ Greggerson 6 Gas Services
Supply, Installation, testing and commissioning of Medical Gas Master Alarm Panel as per tender specifications as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed. Make- Beacon Medaes/ Delta P/ Greggerson
supply installation testing and commissioning of Horizontal Bed Head Panels provision for Gas outlets duly CE marked under Medical Directive 93/42/EEC Make- Aktiv/PSPL/NSP 1200mm
supply installation testing and commissioning of Horizontal Bed Head Panels provision for Gas outlets duly CE marked under Medical Directive 93/42/EEC Make- Aktiv/PSPL/NSP 1500mm
supply installation testing and commissioning of Horizontal Bed Head Panels provision for Gas outlets duly CE marked under Medical Directive 93/42/EEC Make- Aktiv/PSPL/NSP 1800mm
Isolation Valve , Degreased for oxygen Use as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed. Make- Beacon Medaes/ Delta P/ Greggerson 54mm
Isolation Valve , Degreased for oxygen Use as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed. Make- Beacon Medaes/ Delta P/ Greggerson 42mm
Isolation Valve , Degreased for oxygen Use as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed. Make- Beacon Medaes/ Delta P/ Greggerson 28mm
Isolation Valve , Degreased for oxygen Use as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed. Make- Beacon Medaes/ Delta P/ Greggerson 22mm
Isolation Valve , Degreased for oxygen Use as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed. Make- Beacon Medaes/ Delta P/ Greggerson 15mm
Isolation Valve , Degreased for oxygen Use as per HTM/ ISO 7396/ NFPA-99 Standard and CE certified under Medical Directive Notified Body with 4 digit no or UL/ ATL listed. Make- Beacon Medaes/ Delta P/ Greggerson 12mm
Control Panel for Compressed Air System and Vacuum System Make- Indigenous
Bidder Name
Amount
JCC INFRAPROJECTS PVT. LTD.
SNS INFRACON PVT. LTD.
SNS INFRACON PVT. LTD.
SNS INFRACON PVT. LTD.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid