Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | L1 | Accepted-AOC being lowest | |
| 2 | L2₹21.1 L+₹3.2 L (17.7%)Rejected-Finance | L2 | Rejected-Finance Highest amount quoted |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
30 Mar 2022, 6:00 pmClosed
AGE I UDAIPUR
ASST. GARRISON ENGINEER (I) EKLINGGARH CANTT, UDAIPUR (RAJ.) - 313001
REPAIRS/MAINTENANCE OF 11 KV SUB STATION AND 11 KV LINE OF E/M SERVICES, HT SYSTEM SERVICING OF HT VCBs/GO, DO OF 11 KV AND CONNECTED WORKS IN ARMY AREA AT UDAIPUR MIL STN
2021_MES_471427_4
8667/E8/AGE I UDAIPUR
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA UDAIPUR
as per tender documents
5 documents required · 5 mandatory
₹500
AGE I UDAIPUR
₹40,000
Yes
15 Jul 2022
16 Mar 2022
1 Apr 2022
16 Mar 2022
30 Mar 2022
16 Mar 2022
Amount
Taking down old Unsv Go's and Supply & install 11 KV air break gang operated triple pole out door type gang operated air break switch mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level with 09 Nos insulators outdoor type triple pole suitable for horizontal/vertical installation provided with locking arrangement consisting of MS channel HT post type insulator high pressure heavy lined copper alloy contact assembly suitable for 200 Amps, including air break switch suitable for 11 KV, 200 Amps mounted on 06 Insulators with drop out fuse unit ,operating rod 20m dia GI medium grade pipe complete all as specified and directed.
Material and labour for renewal of earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized strip 32 X 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr complete all as specified and directed.
Material and labour for renewal of earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or stee all as shown in electrcal plate No 3 of SSR Part-I connected to continious earth wire or main switch board/ panel etc all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia,light grade GI pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI wire and protection pipe upto 7.5 mtr complete all as specified and directed.
Taking down old unserviceable Old LT panel and Supply, install, testing and commissioning of electric panel board outdoor type suitable for LT 415 volts 3 phase 4 wire system factory made cubical complete materialised dust and vermin proof (protection class IP 54), made out of 3.15mm thick MS sheet (CRCA) including factory made hinged type double door both side opening with locking arrangement duly painted with two coats of synthetic enamel paint with powder coated finish over a coat of zinc chrome primer including carry out internal connection with suitable copper bus bar (above and incl 63 Amp MCCB)/ 16 Sqmm (below 63 Amp MCCB) single core copper cable, including cable alley for incoming and outgoing cable complete all as specified and directed by Engineer-In-Charge. the panel board shall be comprising of the following accessories
(a) Copper bus bar cap 400 Amp-04
(b) MCCB four pole with thermal magnetic release adjustable type with breaking capacity 35 KA, 400 Amp - (incomming) 01
(c) MCCB four pole with thermal magnetic release adjustable type with breaking capacity 35/36 KA 200 Amp (out going)- 02
(d) MCCB four pole with thermal magnetic release adjustable type with breaking capacity 25 KA 63 Amp -02 Nos.
(g) RYB neon indicating lamp set of three- 01. Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size and 45cm height and 4 Nos legs of 50mmx50mmx6mm and 60 cm in height for fixing the panel (ii) MCCB shall be fixed in suitable sheet metal enclouser (iii) Danger notice plate (02 Nos) LT size 20cmx 15cm shall be fixed on the panel (iv) Contractor provided power coated finish paint on panel.
Taking down old Unsv bus bars, and Supply and install, testing and commissioning of Bus bar chamber of size 60 cm x 60cm x 40 cm outdoor type suitable for LT 415 volts 3 phase 4 wire system factory made cubical complete materialised dust and vermin proof (protection class IP 54), made out of 3.15mm thick MS sheet (CRCA) including factory made hinged type door both side opening with locking arrangement duly painted with two coats of synthetic enamel paint with powder coated finish over a coat of zinc chrome primer complete all as specified and directed by Engineer-In-Charge. the panel board shall be comprising of the following accessories
(a) Copper bus bar cap 250 Amp-04
(d) RYB neon indicating lamp set of three- 01
Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size and 45cm height and 4 Nos legs of 50mmx50mmx6mm and 60 cm in height for fixing the panel (iii) Danger notice plate (02 Nos) LT size 20cmx 15cm shall be fixed on the panel (iv) Contractor provided power coated finish paint on panel.
Taking down old unsv & Supply and fix MCCB AC, 415 volts, 4 pole adjustable type, 250 Amps, breaking capacity 35 KA complete all as specified and directed.
Taking down old unsv & Supply and fix MCCB AC, 415 volts, 4 pole adjustable type, 200 Amps, breaking capacity 35 KA complete all as specified and directed.
Taking down old unsv & Supply and fix MCCB AC, 415 volts, 4 pole adjustable type, 160 Amps, breaking capacity 35 KA complete all as specified and directed.
Taking down old unsv & Supply and fix MCCB AC, 415 volts, 4 pole adjustable type, 63 Amps, breaking capacity 35 KA complete all as specified and directed.
Taking down old unsv & Supply and fix MCCB AC, 415 volts, 4 pole adjustable type, 125 Amps, breaking capacity 35 KA complete all as specified and directed.
Taking out old cork sheet gasket of transformer of 63 KVA to 400 KVA and Supply & fix new super quality gasket of 4mm thickness including making smooth finish of new gasket checking fo leakage after replacement of gasket.Note :- Gasket shall be replaced at no extra cost if leakage found after replcement of gasket.
Diconnecting & taking out old unserviceable LV bushings complete from transformer of 63 KVA to 400 KVA and Supply and fix new LV bushings with brass metal part including brass nuts with washers of suitable size inside and outside of the bushings, insulator and reconnecting the LV lead and testing after completion complete upto the satisfaction of Engr--Charge.
Diconnecting & taking out old unserviceable HV bushings complete from transformer of 63 KVA to 400 KVA and Supply and fix new HV bushings with brass metal part including brass nuts with washers of suitable size inside and outside of the bushings, insulator and reconnecting the HV lead and testing after completion complete upto the satisfaction of Engr--Charge.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in hard dense soil, levelling and removing grass, treemining of tree etc from side and applying 10mm thick lime (white wash) as directed
Material and labour for Zebra painting with two coats of Ist quality synthetic enamel paint on HT/LT concrete poles up to 1.5 metre height from pedastal in 30 cm height in black & white paints including two coat of cement base paint on Pedastal of Pole and Painting the Cross arms with one coat of Synthetic/Aluminium enamel paint incl preparation of steel surfaces and including writing the pole Nos of 50mm height letters / figures with acrylic PVC strip "MES/LT ___" (pole number) all as directed
Excavation in trenches n. exc. 1.5 mtr deep and n. exc. 1.5 mtr wide and getting out complete.
Returning & filling in layers n. exc. 25cm each including watering and well ramming after filling complete all as directed.
Removal of excavated surplus material to a distance n. exc. 50 mtr away in layer n. exc. 25cm from the starting point all as direcet by Engr-in-Charge.
Material and labour for with Graded stone aggregate 20mm filling under 2/4 pole structure, outdoor panel and feeder piller board, over sand.
Material and labour for Graded stone aggregate 40mm filling under 2/4 pole structure, outdoor panel and feeder piller board, over sand.
Precast cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) slab flooring, bedded, and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 consisting of 50mm thick
Precast cement concrete type D-2, 1:4:8 (20mm graded stone aggregate) slab flooring, bedded, and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 consisting of 75mm thick
Material and labour for MS angle, flats, bolts, nuts, washers for posts and struts for fencing / gates of LT panel board and transformers including cutting tops to shape as directed, drilling holes including all drilling, riveting or bolting etc and similar work confirming to Fe-290 grade E-165 complete all as directed by Engr-inCharge.
Supply & Fixing chain link MS galvanised fencing 3.15 mm dia MS galvanised wire 50 mm square mess, for protection outdoor LT feeder panels all as directed by Engr-in-Charge.
Supply & Fixing Mild steel plain galvanised wire 12 mm dia round bars in fencing etc.
Material and labour Sand filling under floors or in foundations including watering and consolidation, spreading under stone/bricks aggrgate alround the LT panels/Feeder Pillars, cable laying etc.
Material and labour for sand stone slab ( patti) roughly hammer dressed stone 40 to 50 mm thick 25 to 30 cm wide and not less than 60 cm long laid dry and abutting each other with gap between adjacem,ent salb not exceeding 10 mm over underground cables for protection.
Material and labour for supply and fixing laying cable in trenches, HT under ground XPLE insulated, PVC sheathed 11000 V armoured heavy duty aluminium conductor including testing commissioning of size 95 Sq mm 3 core
Material and labour for supply and fixing laying cable in trenches, jointing with proper lugs, cable glan , LT under ground XPLE insulated, PVC sheathed 1100 V armoured heavy duty aluminium conductor including testing commissioning of size 10 Sq mm 4 core
Supply only tinned copper drop out fuse suitable for HT 11 KV line of sizes 10 Amps to 60 Amps
Material and labour for Cable route marker made out of Sand stone of size 0.15m wide and 0.60m long including writing the HT/LT Cable by engraqvinging/ painting complete fixed in PCC including excavation and RF and removing complete all as directed by Engr in Charge
Taking down old Unsv and supply and fixing Cable jointing kit for 11 kv (Eartherd ) grade cable for outdoor termination heat shrink type joint complete with jointing material and accssories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm
Taking down old Unsv and supply and fixing Cable jointing kit for 11 kv (Eartherd ) grade cable joint, heat shrink type straight through joint complete with jointing material and accssories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm
Taking down old Unsv and supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
Taking down old Unsv & Supply & Fixing Shackle Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, 150mm height, 150mm dia for 11000 volts working pressure grade and with galvanised steel section straps in mm 38x5 with 20 mm dia of bolts
Material and labour Non linear resistor type surge arrester( lightening arrestors) confirming to IS 3070 (Part 1) having voltage rating 12 KV, Rated frequency-50 HZ, Nominal Discharge current 10 KA(Heavy duty) complete with all fittings , suitable for 11KV, 3-Phase, earthed distribution system complete all as specified
Taking down Old U/S LED Street lights of any size and Supply & Fixing Solar LED “Lithium based Energy Efficient Integrated Solar Street Light of 32Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 65/67Wp , Lithium Battery 11.1/12.8V, 33.0AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 16-18kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant. Make : AXXON or eqvt.
Supply & Fixing in repair Single phase Electronic Energy Meter with high accuracy class 1.0, high overlaod cap of six times of basic rate, tampper proof, LCD dispaly mechanism etc confirming to IS 13779 complete all as spd and directed (Make-Bentec India Ltd.(Brand-Benlo)/HPL/Havells)
Supply & Fixing in repair water heater/geyser of capacity 10 ltrs, Voltage / Frequency (V/Hz) 230V/50Hz (Make-Jaquar, Elena plus)
Supply & Fixing in repair Intant water heater/geyser of capacity 3 ltrs, Rated Wattage 4.5 kw and Voltage / Frequency (V/Hz) 230V/50Hz (Make-Jaquar)
Supply & Fixing in repair plastic Exhaust Fan blade Size 200mm and Cut-out Size - Sq 242 x 242 mm, White, power Consumption: 35 watts; Operating Voltage: 220V - 240V, Number of Blades 5 etc all as spd (Make-Luminious Vento Delux/Usha/Havells)
Supply & Fixing SMC junction box with bus bar with MCB of cap 20Amps 230 volts Make : Syntex or equivalent and make of MCB Havells/Legrand/Standard/ C&S all as directed by Engr- in- charge
Supply & Filling and topping up fresh transformer Oil having dielectric strength more than 50 KV capacitor at 2.5 mm gap for transformer , all as speceified and directed by Enger - in - charge.
Boarding, supplied & fixed with nails in any situation (except flooring and skirting) Planed one side and edges tongued and grooved or rebated of 40 mm thick not exc 60 cm long 30 to 35 cm wide hard wood 2nd class for two pole/four pole structres
Taking down old unsv & Supply & fixing GI 40mm light grade protection pipe all as specified and directed
Taking down old unsv & Supply & fixing GI 80mm light grade protection pipe all as specified and directed
Taking down old unsv & Supply & fixing GI 25mm light grade protection pipe all as specified and directed
Supply only copper sulphate
Supply only TCC90A
Supply only Alum
Material and labour for cleaning of swimming pool size Appx 2 lalh gallon capacity and balancing tank, removing complete dust and dust removing scale from wall, floor and desk area titles with and incl required chemicals etc carefully all as per directed by Engr-in-Charge
Material and labour for cleaning and serricing of pressure filter tank complete opening replacement of sand with scalling solvent washing assembling all as specified and directed by Engr-in-Charge.
Material and labour carrying to workshop U/S monoblock motor pump including catting U/S winding, removing insulating material, cleaning and rewinding with PVC insulated 1100 volts grade single core copper conductor as per IS-694 winding wire of appropriate Size/grade as per existing providing insulating material of superior quality supply and replace thrust bearing assembling the motor complete of capacity 5 HP
Supply & Fixing in replacement of UPVC pipes of pressure rating 10-25 Kg/cm2 size 100 mm dia for pressure filter tank
All as per above item No 54 for dia 50 mm
Punjab Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .