| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹16.5 L+₹2.9 L (21.5%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹17.0 L+₹3.4 L (24.8%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹17.8 L+₹4.3 L (31.3%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹18.4 L+₹4.8 L (35.2%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹27.8 L
EMD Value
₹55,550
Closing Date
3 Jun 2023, 6:00 pmClosed
MAJ SRINATH PL
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/MAINT OF INTERNAL ELECTRIFICATION, FITTINGS FIXTURE AND ALL CONNECTING ITEMS AND STREET LIGHTS SECURITY LIGHTS OF DGQA CAMPUS AND CONNECTED AREA UNDER GE(I) KANPUR.
2023_MES_595771_1
GE(I)/KAN/T-20 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
KANPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE(I) KANPUR
₹55,550
Yes
12 Aug 2023
16 May 2023
9 Jun 2023
16 May 2023
3 Jun 2023
29 May 2023
Amount
Supply and fix LED Alumimium batten luminaire surface mounted, 4 feet system wattage of 20/22 Watts with lifetime of not less than 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 20%, , surge protection 3KV in CM, IP-20n Protected, meets LED IS specifications, Class-1, Short circuit and over circuit protection, voltage range-150 to 270 Vots AC, System effiency at luminaire lelvel > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixe complete all as pecified and directed by Engr-in-charge. Note:- All the above mentioned specifications will be verifed through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures.
Supply and fix in replacement cable PVC insulated unsheathed with flexible multistranded copper conductor of size 0.75 Sqmm.
All as per item No 2 above but size 1.5 Sqmm and complete all as specified and directed.
All as per item No 2 above but size 2.5 Sqmm and complete all as specified and directed.
All as per item No 2 above but size 4 Sqmm and complete all as specified and directed.
All as per item No 2 above but size 6 Sqmm and complete all as specified and directed.
All as per item No 2 above but size 10 Sqmmand complete all as specified and directed.
M&L for switch piano flush button single pole one way 5 amps 240 volts and complete all as specified and directed.
Switch piano flush button single pole one way 15 amps 230 Volts and complete all as specified and directed.
Attending complaints fo checking and replaceing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. attending minor repair(s) such as testing, connectins, fittings, nut, bolts, screws etc to emergent complaints i.e no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electical system of main building/block and making continuous electric supply including carrying out minor repairs etc.. required to make the system in order/*functional with insualtion tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Engineer-in-Charge. Notes :- This item is applicable only where no store is required. 1. The site for attending complaints at DGQA Area, ASC deopt, Napier Rd,Harding Rd Officers Bunglow. Contractor shall provide minimum one tradesmen (electrician) for each site to attend the complaint in all working days between 0830 hrs to 1700 Hrs including holiday and Sunday. 2. Contractor shall ensure the security passess for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the electicians with necessary tools bag shall always remain present at complaint cell to attend the Complaints. 4. A recovery of Rs 500/- for not attending the complaint upto 04 hours and after 04 hours Rs 1000/- shall be recovered from the contractor due 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7. The above tradesmen shall not be utilize for the complaints where material is required and these complaint shall be measured and paid seperately as S&F here in after.
S & F in replacement of LED post top lantern 35/40 Watt warm white made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP-65 protection fixing with proper arrangements and making electrical connection complete all as spfd.
S & F in replacement of LED post top globestarmade up of unbreakable polycarcarbonate suitable for mounting on gate with led bulb 12 W with proper arrangements and making electrical connection complete all as spfd. Make :Surya Cat Part No SLE PT 12W-GS250 or equivalent in Wipro/Bajaj/havells
Supply and fix LED alumimium batten luminaire surface mounted, 2 feet system wattage of 10 Watts with lifetime of not less than 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 20%, , surge protection 3KV in CM, IP-20n Protected, meets LED IS specifications, Class-1, Short circuit and over circuit protection, voltage range-150 to 270 Vots AC, System effiency at luminaire lelvel > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixe complete all as pecified and directed by Engr-in-charge. Note:- All the above mentioned specifications will be verifed through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures.
S&F in replacement of LED light fitting recess mounted 36 Watt, 1' x 4' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection with making electrical connection with three core copper wire to ceiling rose properly all as directed.
S&F in replacement of LED light fitting recess mounted 35/36 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making making electrical connection with making electrical connection with three core copper wire to ceiling rose properly all as directed.
Supply and fixing 10W surface mounted IP65 Bulkhead with system efficiency of 100LM/Watt LED bulk head shall be made up of Die cast Aluminium housing for better heat decapitation.P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.
M&L for sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 25 amps 240 volts, complete with one single pole MCB of 25 amps earthing.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 protection with acrylic cover single phase 240 volts 4 way, including suitable size copper bus bar and neutral link of make Legrand or equivalent of make Havells/L&T fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
All as per srl item No 47 above but for 8 way.
M&L for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 KA using thimbles of required size.
M&L MCB single pole & neutral 240 volts 32 amps,with rupturing capacity 10 KA using thimbles of required size.
All as per item No 21 above but of size 63 Amps.
Supply and fix in replacement of LED Wall Security light 25 Watt IP 66 Energy saving & environmental friendly long life pressure die-cast aluminium housing for better heat decapitation efficiency not less than of 100LM/Wat ,P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated complete all as spfd.
S & F switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal with complete box all as specifid and directed
S & F switch socket combination 2 in 1, 3 pin,15 Amp flush type universal with complete box all as specifid and directed
S & F Switch socket combination 2in 1, 5 A flush types all as specifid and directed
S & F Switch socket combination 2in 1, 15 A flush types all as specifid and directed
S & F of led Bulb of 09 Watt cool day light eco friendly energy efficient all as specified and directed by Engr In Charge.
M&L in replacement of earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion.
Taking down defective SV / MH lamp type of 70 / 150/250 W, LED street light/flood lights, any type, wattage and at any height, mounted on poles / bldgs with bracket, disconnecting and removing from site for replacing of unsv lamp / copper ballast / ignitor / LED driver, replacing only LED drivers & refixing the same complete all as specified and directed. NOTE: (i) Spare parts of fitting shall be measured & paid seperately as supply only in respetive items. (ii) Rate for suitable connecting wire from pole to fitting if reqd are included in quoted rates. (iii) Complaint slip book, complaint register and ladder and T & P shall be provided by the contractor (iv). Complaints of street/flood lights shall be done on daily bases and after completion the complaint slip deposited to concern JE E/M.)
Supply only LED driver for street Light 20 to 45W as per sample or directed . Make : CG / Havells/ Philips/ Wipro/Bajaj/C&S.
Supply only LED driver for street Light 60 to 75W as per sample or directed . Make : CG / Havells/ Philips/ Wipro/Bajaj/C&S.
Supply only LED driver for street Light 80 to 100 W as per sample or directed . Make : CG / Havells/ Philips/ Wipro/Bajaj/C&S.
Material & labour for plain cement concrete (1:4:8) Type D-2, using 40 mm grade stone aggregate for filling of poles as mass concrete etc complete all as specified and directed.
Material & labour for plain cement concrete (1:3:6) Type C-1, using 20 mm grade stone aggregate for poles coping , pavings/trenches/hard standing/footpath etc complete all as specified and directed.
Disconnecting and taking out existing unserviceable LT Cables of 6 Sqmm to 16 Sqmm in any position and removing from site complete all as specified and directed by Engineer-in-Charge.
Supply laying , jointing, testing and commissioning of XLPE insulated, PVC sheathed, strip armoured heavy duty electric cableof size 4 core 25 sqmm with aluminium conductor (stranded) working voltage upto 1100 volt confirming to IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of aluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed. Note : Cable laying and jointing are required to be carried out in short / long stretches as per site requirement
All as per item no.but of size 4 core 16 sqmm
All as per item no.but of size 4 core 10 sqmm
Supply and laying to wall or poles or fixing or passing through pipe, of 1100 volts grade heavy duty cable with PVC insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 10 sq. mm nominal cross section 2 core Including making good all distributed wall / flooring/tilling surfaces to match with existing specification complete all as specified and directed. Make: Gloster/Havells/ Paragon/ Grandlay/Finolex
All as per srl item No 26 but cable of size 6 Sqmm 2 core.
All as per srl item No 26 but cable of size 16 Sqmm 2 core.
S & F cable heat shrinkable outdoor/indoor terminal end joint, 1.1 KV grade, complete with jointing material and accessories with full sleeves and thimbles suitable for XLPE/PVC armoured aluminium conductor cable of size 6 to 16 Sqmm 2 core. Make: Reychem/Dension/Birla 3 M .
Supply & fix in replacement cable PVC insulated flexible copper conductor cable of size 2.5 Sqmm twin core cut to pieces all as required for connection with proper thimbles, drawn in existing GI/PVC pipe fixed on wal/pole, in steel pole and bracket from junction box to street light all as directed. Make of Cable : Havells /Plaza/ Grandlay/Finolex/ Paragon
All as per item No- 43 but of size 1.5 Sqmm twin core.
M & L for making 2 hole of 14 mm dia on the existing LT Steel pole at height of 1.5 mtr from GL and top of the pole near to bracket for inserting 2 core, 4 sqmm cable from junction box to street lights all as specified and directed
Supply and fix in replacement of High power LED street light 45/48 Watt IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium roadway luminaire with high power LEDs as light source and electronic driver fixed on pole/wall along with service bracket as per sample, clamps as directed, nuts, bolts, and washers as directed incl electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated from junction box to street light by laying in bracket/ pipe/ pole complete all as spfd.
All as per item No-47 above but LED street light 70/72/75 Watt
All as per item No-47 here-in-before but LED street light 90/100 Watt.
All as per item No-47 here-in-before but LED flood light 50 Watt.
All as per item No-47 here-in-before but LED flood light 100 Watt
All as per item No-47 here-in-before but LED flood light 150 Watt .
S & F in replacement of street light bracket made out of GI tubing, light grade, 25/32/40mm bore, 1000mm long, bent to shape at 120 degree, fixed on pole by providing two sets of MS clamp made up of flat iron 40 x 6mm including bolts, nuts and washer of suitable size including painting the bracket & clamp with two coats of aluminium paint over a coat of primer complete all as specified and directed.
Dismantling unserviceable steel tubular poles of any type complete and remove from site all as specified and directed by Engineer in charge. .
Supply, erecting and installation of steel tubular, swaged, pole of overall length 9 meter having maximum tensile strength 42 Kgf/mm2 of type 410 SP-31 conforming to IS-2713-1980, made out of 50 mm dia MS pipe 1.5 mtr long to be jointed on top of LT pole incl fabrication work for fixing street light. A through hole of 14 mm dia shall be provided at height of 2.5 mtr from base plate for inserting 2 core cable from junction box to top of the pole and top portion shall be fabricated for fixing street light fittings including earth work complete with cast iron base plate, having suitable dia of hole through the pole with nuts & bolts for earthing arrangement, bottom portion of tubular steel pole having 165.10 mm outer dia in 5 meter length, 4.5 mm wall thickness, middle portion having 139.70 mm outer dia in 2 metre length 4.5 mm wall thickness and top portion having 114.30 mm outer dia in 2 meter length, 3.65 mm wall thickness of pole wall, respectively, bottom MS square plate duly painted with two coat of black bituminous paint throughout, internally and externally up to planting depth and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making / pasting three nos circular strips each of 100 mm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking / stencil writing of pole numbers with black paint including necessary excavation & earth work, removing excavated soil from site complete all as specified & directed. Note :- Necessary Excavation and earth work, PCC Work for foundation / erection of pole assembly will be measured and paid separately under respective item of BOQ schedule.
Supply, fixing, testing and comissioning of automatic street light switch of capacity 8 KW in single phase using nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals enclosed in pole / wall mounted enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box (Make: Sintex) conforming to IP54, including mounting arrangement with suitable size of FI clamps 02 Nos with complete acessories as under including taking down old street light switch complete all as specified and directed. (i) Contactor rating (AC3) single phase, 50-63 Amp : [Make : BCH/L&T/Schneider] (ii) MCB 63Amps (SP),10 KA, 240 volts: [Make : Schinder/ Legrand/ L&T] (iii) NATURESWITCH-01 [Make: HEALER (Model No. SWADEEP - 02EC8KW1P)]
S&F in repair weatherproof junction box of size 240x130x110 mm outdoor type made out of thermo polycarbonat to accmmodated 04 Nos aluminium bus bar of size 25x6 mm rating 200 Amps and MCB SP 6 Amps IP-65 with hinged door and triangular locks water proof, shocked proof, rust proof, corrosion free, acid resistance/fire retardent and self extinguishing UV resistance complete fixed on pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc., including two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer on iron/steel parts complete all as specified and as directed. Make: Sintex/ Hansel/Hager as approved by GE(I).
S&F in repair weatherproof junction box of size 200x140x95 mm outdoor type made out of thermo polycarbonat to accmmodated 02 Nos aluminium bus bar of size 25x6 mm rating 200 Amps and MCB SP 6 Amps IP-65 with hinged door and triangular locks water proof, shocked proof, rust proof, corrosion free, acid resistance/fire retardent and self extinguishing UV resistance complete fixed on pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc., including two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer on iron/steel parts complete all as specified and as directed. Make: Sintex/ Hansel/Hager as approved by GE(I).
Disconnecting electrically, dismantling and taking out existing street light junction box any size/type from PCC/steel pole and refixing on same pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc after repair including two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer on iron/steel parts and making electrical connection complete all as specified and as directed.
M & L for painting of steel pole (swan neck type or straight type) up to 12 mtr height with cross arms, clamp of any length and shape for LT overhead line / for street light with two coat of aluminium paint after scraching out old paint, cleaning and existing surface rust free, preparation of the existing surface, including marking pole numbers in a 20 cm dia yellow circle with number writting with black syenthic paint & painting strips in alternate from bottom to top with three strips of black syenthatic paint & two strips of yellow fluorescent paint (up to 1.5 mtr height) through out the circumference of pole (width of each strip shall be of 30 cm), complete all as specified and directed.
Demolition & dismantling of cement concrete in ground floors and paving for making trench for laying XLPE cable etc including removing the debris from the site
Material & labour for plain cement concrete (1:3:6) Type C1, using 20 mm grade stone aggregate for filling the pavings / trenches / foot path etc complete all as specified and directed.
Disconnecting, dismantling and taking out old seviceable/unserviceable street/flood lights fitting any type from pole/ wall and refixing the same on same or other location and connecting electrically with the wire 1.5 sqmm twin core after repairing all as spfd and directed..
Excavation in trenches / foundation in soft / loose soil not exc. 1.5 metre wide and n'exc. 1.5 m deep for HT / LT under ground cable / pole fondation and getting out including forming bottom surface to required level or slop, complete all as specified and directed by Engineer-in- Charge.
Returning filling of excavated soil after laying the cable with spreading leveling watering and well ramming in layers not exceeding 25cm thick in loose/soft soil complete all as specified and directed.
Removal of surplus soil/excavated material obtained from ground level to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above from the starting point complete all as specified and directed.
M&L for sand cushning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm complete all as speified and directed. .
S B ENTERPRISES
SAKSHAM SUPPLIERS BUILDERS
M/s A S Electrical
Preetpowercontrol
santosh electronics
M/S G S Gupta and Sons
PAWAN COOL CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .