Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 CrAccepted-AOC AT HATATOTA ARYA VIHAR PO TALCHER PS TALCHER DIST ANGUL | PURI | ODISHA | 752001 | ₹9.1 Cr | L1 | Accepted-AOC Awarded being the L1 bidder |
| 2 | L2₹10.6 Cr+₹1.5 Cr (16.8%)Rejected-Finance AT KOTASAHI KAIRAPARI TANGI DIST CUTTACK | CUTTACK | CUTTACK | ODISHA | ₹10.6 Cr+₹1.5 Cr (16.8%) | L2 | Rejected-Finance Rejected not being the L1 bidder. |
| 3 | L3₹12.2 Cr+₹3.1 Cr (34.1%)Rejected-Finance AT COLLEGE ROAD KARADAPALI GOBARA TALCHER PO SOUTH BALANDA PS COLLIERY DIST ANGULA STATE ODISHA PIN 759116 | TALCHER | ANGULA | ODISHA | 759116 | ₹12.2 Cr+₹3.1 Cr (34.1%) | L3 | Rejected-Finance Rejected not being the L1 bidder. |
| 4 | L4₹28.3 Cr+₹19.2 Cr (211.6%)Rejected-Finance | ₹28.3 Cr+₹19.2 Cr (211.6%) | L4 | Rejected-Finance Rejected not being the L1 bidder. |
Tender Value
₹13.0 Cr
EMD Value
₹16.2 L
Closing Date
26 Dec 2023, 5:00 pmClosed
Sri Sambit Pattnaik
MCL.Jagriti Vihar. Burla. Dist.-Sambalpur. PIN-768020. Odisha. Contact No.9438494886.9437485368. 0663-2542779.
Construction of Coal Transportation Road (concrete surfacing) with one underpass along the coal corridor from the MGR siding I and II ( rail underpass) to Balunga village road underpass of Lingaraj Area (Phase-1)
2023_MCL_295586_1
MCL/Samb/Civil-TC/e-Tender/ 23-24/19 Dt.08.12.2023
Open Tender
Civil Works - Roads
Item Rate
2005 days
Lingaraj Area, MCL
As per tender documents.
5 documents required · 5 mandatory
₹16.2 L
16 Apr 2024
8 Dec 2023
28 Dec 2023
8 Dec 2023
26 Dec 2023
9 Dec 2023
8 Dec 2023 - 19 Dec 2023
Amount
Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevant clauses of section - 300 )
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 metres. (Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead upto 1000m as per relevant clauses of section - 300 of specifications)
Granular Sub-base with Well Graded Material (CBR>30 or more) (Table:- 400-1 & Table 400-2) Construction of granular sub-base by providing well graded material like natural sand crushed gravel or crushed stone having CBR >30, spreading in uniform layers with motor grader on prepared surface, mixing by plant mix method at OMC, and compacting with vibratory rollers of 80 to 100 kN static weight to achieve the desired density, complete as per Clause 401 of Specification. for grading- I Material
Granular Sub-base with Well Graded Material (CBR>30 or more) (Table:- 400-1 & Table 400-2) Construction of granular sub-base by providing well graded material like natural sand crushed gravel or crushed stone having CBR >30, spreading in uniform layers with motor grader on prepared surface, mixing by plant mix method at OMC, and compacting with vibratory rollers of 80 to 100 kN static weight to achieve the desired density, complete as per Clause 401 of Specification. for grading- III Material
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601 of specifications complete in all respect.
Cement Concrete Pavement ( Construction of un-reinforced, dowel jointed, plain cement concrete pavement (minimum flexural strength - 4.5 Mpa) over a prepared sub base with cement @ 400 kg per cum (minimum), coarse and fine aggregate conforming to IS 383,maximum size of coarse aggregate not exceeding 31.5 mm, mixed in a batching and mixing plant as per approved mix design,transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved,curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc.
Supplying, fitting and placing Mild steel reinforcement complete in substructure as per drawing and technical specification and as per relevant clause of section 1600
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications and as per relevant clause of section 1600
Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC 67 2010 made of High Intensity microprismatic grade sheeting Type XI vide clause 801.3.3 fixed over aluminium composite material sheet with thermoplastic core of low density polyethylene (LDPE) between two thick skins sheets of aluminium with overall thickness of 4 mm and aluminium skin of thickness 0.3 on both side, the ACM shall conform to table 800-1 of specification and high intensity microprismatic grade sheeting shall conform to table 800-3 of specification. The printing on the high intensity grade sheeting shall conform to Clause 801.3.7 with water based latex optimized transparent ink as specified by the sheeting manufacturer, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to ground by means of properly designed foundation with M15 grade concrete 450x450x600mm The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. 90 cm equilateral triangle
Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC 67 2010 made of High Intensity microprismatic grade sheeting Type XI vide clause 801.3.3 fixed over aluminium composite material sheet with thermoplastic core of low density polyethylene (LDPE) between two thick skins sheets of aluminium with overall thickness of 4 mm and aluminium skin of thickness 0.3 on both side, the ACM shall conform to table 800-1 of specification and high intensity microprismatic grade sheeting shall conform to table 800-3 of specification. The printing on the high intensity grade sheeting shall conform to Clause 801.3.7 with water based latex optimized transparent ink as specified by the sheeting manufacturer, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to ground by means of properly designed foundation with M15 grade concrete 450x450x600mm The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. 60 cm circular
Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC 67 2010 made of High Intensity microprismatic grade sheeting Type XI vide clause 801.3.3 fixed over aluminium composite material sheet with thermoplastic core of low density polyethylene (LDPE) between two thick skins sheets of aluminium with overall thickness of 4 mm and aluminium skin of thickness 0.3 on both side, the ACM shall conform to table 800-1 of specification and high intensity microprismatic grade sheeting shall conform to table 800-3 of specification. The printing on the high intensity grade sheeting shall conform to Clause 801.3.7 with water based latex optimized transparent ink as specified by the sheeting manufacturer, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to ground by means of properly designed foundation with M15 grade concrete 450x450x600mm The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. 60 cm x 45 cm rectangular
Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-20 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with premoulded asphalt filler board, keyed to the structure on which it is built and installed as per design and dimensions in the approved drawing and at locations directed by the Engineer, all as specified). M 20 grade concrete
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material as per relevant clauses of section 300 & 2100 ). Ordinary soil . Mechanical Means: Depth upto 3 m
Plain/Reinforced cement concrete in open foundation including formwork, shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of section 1500, 1700 & 2100. PCC Grade M15
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification and as per relevant clauses of section 1700.
Plain/Reinforced cement concrete in open foundation including formwork, shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of section 1500, 1700 & 2100. RCC Grade M25 : With Batching Plant, Transit Mixer and Concrete Pump
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. RCC Grade M25. Height upto 5m. With Batching Plant, Transit Mixer and Concrete Pump
Furnishing and Placing Reinforced/Prestressed cement concrete in superstructure as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 & 2300. RCC Grade M25. Using Batching Plant, Transit Mixer and Concrete Pump. For solid slab super-structure: Height upto 5m
Reinforced cement concrete approach slab (Grade of concrete M-30) including reinforcement and formwork complete as per drawing and Technical specification and as per relevant clauses 1500, 1700 and clause 2704 of specifications
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications as per relevant clause of section 1600.
Providing and laying of filter media with granular materials/stone crushed aggregate satisfying the requirements laid down in clause 2504.2.2 of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical specifications
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC/PVC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical specifications
Drainage Spouts complete as per drawing and Technical specification and as per clause 2705 of specifications.
Filler joint: Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and clause 2702 of specifications
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications. Stone/Boulder
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Plain/Reinforced cement concrete in open foundation including formwork, shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of section 1500, 1700 & 2100. RCC Grade M30. Using Batching Plant, Transit Mixer and Concrete Pump
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. RCC Grade M30. Height upto 5m. With Batching Plant, Transit Mixer and Concrete Pump
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
SRI DURGA CONDEV PVT LTD
NANDA INFRA CONSTRUCTION PRIVATE LIMITED
KRISON INFRATECH PRIVATE LIMITED
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .