| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.3 LAccepted-AOC BASGO LEH 194 101 U T LADAKH INDIA | LEH LADAKH | LADAKH | 194101 | L-1 | Accepted-AOC Tender Accepted due to lowest and quoted reasonable rates | |
| 2 | L-2₹15.6 L+₹1.3 L (9.07%)Rejected-Finance | L-2 | Rejected-Finance Higher side quoted amount | |
| 3 | L-3₹16.3 L+₹2.1 L (14.5%)Rejected-Finance R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L-3 | Rejected-Finance Higher side quoted amount |
Tender Value
Refer Docs
EMD Value
₹35,200
Closing Date
13 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
CWE Khumbathang
PROVN OF OR LIVING CUM DUTY ROOM FOR TPS AT STN HQ NIMU UNDER AGE(I)NIMU
2022_MES_538891_1
80051/48/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Nimu
As per tender and NIT doc
8 documents required · 8 mandatory
₹500
AGE(I)Nimu
₹35,200
Yes
25 Aug 2022
18 Jul 2022
15 Aug 2022
18 Jul 2022
13 Aug 2022
1 Aug 2022
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil, complete all as specified and as directed.
M&L for Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed by the Engr-in-Charge.
M&L for Precast cement concrete type-C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge.
M&L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in flooring, PCC path, sub base and surface finished even and fair with out using extra cement all as specified and as directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded crushed stone aggregate as in flooring and surface finished rough all as specified and as directed.
M&L for mild steel work (angle iron or flat iron) as in hold fasts, wall ties, clamps, ventilator pipe, rain water pipe,band, straps, hooks for hanging fans, manhole covers, MS rungs and similar small articles conforming to Fe-310-O or Fe-410-O all as specified and as directed.
M&L for RCC Design mix, M-25 ( using 20 mm graded crushed stone aggregate ) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete (Note:-TMT bars will be masured and paid sepretly)
M&L for RCC Design mix, M-25 ( using 20 mm graded crushed stone aggregate ) as in Beams, cantilevers, bressummers, lintels over 1.5m span (Note:-TMT bars will be masured and paid sepretly)
M&L for RCC Design mix, M-25 ( using 20 mm graded crushed stone aggregate ) as in Columns, pillars, piers, posts and struts (Note:-TMT bars will be masured and paid sepretly)
S&F mild steel TMT bars 10 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge.
S&F mild steel TMT bars 6 to 8 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe 410 W (Gde-E-250) quality A.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for preparation of new surfaces of steel of any description , over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge ..
Rendering 15mm thick on fair face of brick work or concrete/stone surfaces in CM 1:4 mixing with WPC @2% by weight of cement or as per manufacturer instruction and finished even and smooth without using extra cement.complete all as specified and directed by Engr-in-Charge. Note:WPC will be measured and paid sepratly.
Supply only water proofing compound.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engr-in-Charge ..
M&L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
M&L for 2nd class hardwood 35mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats for doors.
M&L for 30 mm thick, factory made, glazed and skelton shutter of Second class soft wood, open rebated and prepared to received glass, gauge, etc. (without sash bars) edges of framing plain, chamfered or round, fitted without and mitred beads for securing glass, etc; sizes of members of shutters all as specified in SSR Part-I section 8 clause 8.24(b).
S&F 100mm long butt hinges, medium weight, cold rolled mild steel
S&F 75mm long butt hinges, medium weight, cold rolled mild steel
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised
S&F 100mm long extruded aluminium alloy handles, fabricated type 'D', anodised
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section
S&F 100mm long aluminium anodised, barrel tower bolts of extruded section
S&F 4mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane
M&L for galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples
M&L for preparation of new wooden surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for 2nd class hardwood Plain fillets. Sectional area exc 13 Sqcm and n.exc 25 Sqcm as in square, rectangular or triangular in section, clean sawn, secured with nails or brads.
M&L for 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nail to timber frame work on wall.
M&L for 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nail to timber frame work on cealing.
M&L for hardcore of gauge n exc. 63 mm of broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in plinth protection including provision of necessary form work finishing the exposed surface even and smooth complete all as specified.
M&L Non skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:6 all as specified and directed.
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions
Sch "A' Part-II E/M work:- M&L for point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5 sqmm copper conductor cable unsheathed as earth continuity cable including closed recessed wooden terminal boxes of suitable size made of 2nd class hard wood for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet top cover complete all as specified for the following:- Make of cable: Finolex/Polycab/Havells/Plaza. (a) One light /fan/bell point/buzzer point exhaust fan controlled by one nos, one way 5/6 Amps switch.
One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size
One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size
All as per srl item No 42 here-in-before but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable.
S&F switch socket combination 2 in 1, 3 pin, 5 and 15 Amp.
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type.
S&F Socket outlet multipurpose 2 in 1, 5 pin, 5 Amp flush type
S&F Switch piano, flush type single pole, one way 5 Amp
S&F Ceiling rose 65x50mm, 2 to 3 terminal PVC/polycarbonate, isolated body
S&F LED lights fitting 1x 20W, 4 feet, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F sheet metal powder coated versatile double door SPN distribution board, 8 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz .
S&F MCB SPN 32 Amp 240 volt AC with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F MCB SP 6-32 Amp 240 volt AC with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
Supply, laying and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 2 core complete all as specified
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for laying of cable/pipe & getting out in any type of soil complete all as specified and directed
Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I. (Note:-Punned thickness shall be measured and paid)
Supply and laying un reinforced precast concrete cable cover class LV, type I, flat, size 250 mm x 150 mm x 40 mm complete all as specified.
M&L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earth lead wire 4mm dia by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, strip protected by dia 40 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggregate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result complete including taking out of existing earthing all as specified.
Takshos Enterprises
M/S BHAT ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .