| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹28.1 L+₹2.2 L (8.68%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹29.9 L+₹4.1 L (15.9%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹30.5 L+₹4.7 L (18.1%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹30.5 L+₹4.7 L (18.3%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
3 Oct 2024, 6:00 pmClosed
GARRISON ENGINEER I Rnd D WEST BANGALORE
GARRISON ENGINEER I RndD WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
CERTAININTERNAL REPAIRS TO ELECTRICAL WIRINGS REPAIRS AND MAINT OF FANS INCLUDING ALLIED WORKS REPAIRS TO MCB DBS SUB MAIN WIRINGS MAINTENANCERENEWAL OF EARTHINGS AND REPLACEMENT OF CONVENTIONAL LIGHT FITTINGS IN TECHNICAL AREA AND ALLIED WORKS AT LR
2024_MES_671354_1
GE(I)/R ND D (WEST)/BAN/TOKEN/80 OF 2024-25 8339/E8
Open Tender
Civil Works
Item Rate
180 days
Work
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER I Rnd D WEST BANGALORE
₹72,000
20 Dec 2024
4 Sept 2024
10 Oct 2024
5 Sept 2024
3 Oct 2024
20 Sept 2024
5 Sept 2024 - 19 Sept 2024
Amount
Taking down old / defective point wiring of any surface type (light, fan, socket or power) from the existing locations complete including fixture and fittings such as sunken boxes, laminated sheets along with switches, sockets, regulators, ceiling roses etc. removing materials and making good disturbed surfaces of walls, floors, ceiling etc to match with the adjoining surfaces complete all as specified and directed by Engineer-in-charge.
Material and labour point wiring with 1.5 sqmm FRLS grade single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor for the following surface type in and including new PVC conduit medium grade of any size, complete with all PVC conduit and accessories/ fittings, brass screws, washers etc, along with suitable factory made Sunken boxes concealed suitable for modular type in the existing place or new location including all cutting/chases as applicable etc to accomodate modular plates, covers modular switches & sockets etc in walls, in and including PVC insulated copper earth continuity stranded conductor 1.5 Sqmm FRLS cable green colour connected to common earth dolly complete, making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed by Engineer-in-charge One light point controlled by one switch.
All as per the Item No 2 here above but for One fan/exhaust point controlled by one switch.
All as per the Item No 2 above but for One 5 Amps socket point on same board with other switches
All as per the Item No 2 above but for One 5 Amps socket point on independent board
All as per item No. 2.00 here-in-above but wiring complete with 2.5 Sqmm cable for 3 pin 15A socket multipurpose on independent board.
Taking down carefully existing old / unserviceable / burnt point wiring of any type (light, fan socket or power) complete from concealed conduits of MCB circuit and controlling switch board to light fitting/fan/socket etc including taking down fixture and fittings such as sunken boxes, laminated sheets along with switches, sockets, regulators, ceiling roses etc. removing materials and making good disturbed surfaces of walls, floors, ceiling etc to match with the adjoining surfaces complete all as specified and directed by Engineer-in-charge..
Material and Labour for wiring with 1.5 sqmm FRLS grade single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor for the following drawn through in the existing concealed of any dia in walls, roofs floors etc , along with suitable factory made Sunken boxes concealed in the existing place or new location including all cutting/chases as applicable etc to accomodate modular plates, covers modular switches & sockets etc including brass screws, washers etc in walls with PVC insulated copper earth continuity stranded conductor 1.5 Sqmm FRLS cable green colour connected to common earth dolly as applicable complete all as specified and directed by Engineer-in-charge. Note : (i) Cutiing chases / grooves and PVC conduit as applicable shall be measured and paid separately under relevent item for concealed conduit block portions during new wiring works all as per site and as directed by Engineer-in-charge. One light point controlled by one switch.
All as per item No 8 here in above but for One fan/exhaust point controlled by one switch.
All as per item No 8 here in above but for One 5 Amps socket point on same board.
All as per item No 8 here in above but for One 5 Amps socket point on independent board.
All as per item No. 8 here-in-bove but wiring complete with 2.5 Sqmm for 3 pin 15 Amp socket multipurpose on independent board.
Supply & fixing modular switch 6 Amps 1 module complete all as specified & directed by Engineer-in-charge.
Supply & fixing modular socket 06 Amps 5 pin 2 module complete all as specified & directed by Engineer-in-charge.
Supply & fixing modular switch 16 Amps 1 module complete all as specified & directed by Engineer-in-charge.
Supply & fixing modular socket 06/16 Amps 6 pin 2 module complete all as specified & directed by Engineer-in-charge.
Supply & fixing 2 module dimmer step type electronic fan regulator 120W complete all as specified and directed by Engineer-in-charge
Supply and fixing for replacement LED ceiling mounted recessed full lit luminaire with glare free uniform illumination 36 W 2 ft x 2 ft (>100 Lumen/Watt) illumination suitable for ceiling, operating voltage between 140 - 270 V, AC, 50 Hz, PF >= 0.95,Driver Should be Constant Currnet LED Driver with 2.5 KV Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number, integral drivers, prewired and connecting with 3 Core 1 sq mm copper cable complete in all respects all a directed by Engineer-in-charge.MAKE:- Crompton Cat No.LCTLRNE-36-FO-CDL or techno equ in philips/Havells/Osram/ Wipro/Bajaj/GE as approved by GE.
Supply and fixing for replacement LED ceiling surface mounted full lit luminaire with glare free uniform illumination 36 W 2 ft x 2 ft (>100 Lumen/Watt) illumination suitable for ceiling, operating voltage between 140 - 270 V, AC, 50 Hz, PF >= 0.95, Driver Should be Constant Currnet LED Driver with 2.5 KV Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number, integral drivers, prewired and connecting with 3 Core 1 sq copper cable complete in all respects all a directed by Engineer-in-charge.MAKE:- Crompton Cat No.LCTLSNE-36-FO-CDL or techno equ in philips/Havells/Osram/ Wipro/Bajaj/GE as approved by GE.
Supply and fixing for for replacement outdoor type LED street light fitting 25 watts IP 66 toughened glass high power LEDs lumens not less than 110LPW 10 KV SPD including taking down carefully defective fitting of any type complete all as directed by Engineer-in-charge. Make : Crompton Cat No LSTS-25-CDL-M or techno-commercially equivalent model in philips/Havells/Osram/ Wipro/Bajaj/Halonix as approved by GE.
Supply and fixing for replacement wall mounted LED PC batten, 20 Watt, 4 feet, with energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > =100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, power factor ≥ 0.90, surge protection 2.5 kV, colour temperature 5700 K, integrated electronic driver 20 W fitting prewired and complete in all respects all a directed by Engineer-in-charge. MAKE:- Crompton cat No.CCS-102-20-65-SL-DP-NWH or techno equ in philips/Havells/Osram/ Wipro/Bajaj/Halonix as approved by GE.
Material and labour for replacement LED batten compact industrial with LED polycarbonate T8 tube 20 Watt, 4 feet long, with inbuilt driver and metal heat sink efficacy of 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, with integral drivers, complete all as directed by Engineer-in-charge Make - Cat No DIJB12LT8-20 + LT8-20-865-2 of make crompton or techno commercially equivalent model in philips/Havells/Osram/ Wipro/Bajaj/Halonix as approved by GE.
Material and labour for replacement LED polycarbonate T8 tube 20 Watt, 4 feet long, with inbuilt driver and metal heat sink efficacy of 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, with integral drivers, complete all as directed by Engineer-in-charge Make - Crompton Cat No LT8-20-865-2 or techno commercially equivalent model in philips/Havells/Osram/ Wipro/Bajaj/Halonix as approved by GE.
Material and Labour for replacement ceiling rose 3 terminals 240V complete alla s specified and directed by Engineer-in-charge.
Material and labour for replacement circuit or point wiring with Three single core PVC insulated cable copper conductor multi standed of size 1.5 Sqmm FRLS drawn through in existing surface/recessed steel/PVC conduit/surface casing capping including all accessories complete all as specified and directed by Engr-in-charge.
Material and labour for replacement circuit or point wiring with Three single core PVC insulated cable copper conductor multi standed of size 2.5 Sqmm FRLS drawn through in existing surface/recessed steel/PVC conduit/surface casing capping including all accessories complete all as specified and directed by Engr-in-charge.
Material and labour for replacement submain wiring with Three single core PVC insulated cable copper conductor multi standed of size 4.0 Sqmm FRLS drawn through existing concealed/surface conduit/PVC casing capping including all accessories complete all as specified and directed by Engr-in-charge.
Material and labour for replacement submain wiring with Three single core PVC insulated cable copper conductor multi standed of size 6.0 Sqmm FRLS drawn through existing concealed/surface conduit/PVC casing capping including all accessories complete all as specified and directed by Engr-in-charge.
Material and labour for replacement submain wiring with Three single core PVC insulated cable copper conductor multi standed of size 10.0 Sqmm FRLS drawn through existing concealed/surface conduit/PVC casing capping including all accessories complete all as specified and directed by Engr-in-charge.
Material and labour for replacement submain wiring with Six single core PVC insulated cable copper conductor multi standed of size 6.0 Sqmm FRLS drawn through existing concealed/surface conduit/PVC casing capping including all accessories complete as per site requirements all as specified and directed by Engr-in-charge.
Material and labour for replacement submain wiring with Six single core PVC insulated cable copper conductor multi standed of size 10.0 Sqmm FRLS drawn through existing concealed/surface conduit/PVC casing capping including all accessories complete as per site requirements all as specified and directed by Engr-in-charge. Note for Sl No. 25 to 31 :- (i) Cutting/grooves/chiselling as applicable shall be measured and pad separately and the quoted rate by the tenderer is inclusive for making good concealed conduit wiring portions in all respects to match with the adjoining surfaces (ii) Damaged portions of PVC conduit shall be measured and paid separately under relevent item here-in-after
Material and labour for Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface complete on roof/wall using required necessarty Tools and plants all as per site requirements as specified and directed by Engineer-in-charge.
Supply and fixing for replacement Rigid non-metallic PVC conduit/casing capping of upto 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc all as per site conditions complete specified and directed.
Supply and fixing for replacement Rigid non-metallic PVC conduit/casing capping above 25 mm not less than 40 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc all as per site conditions complete specified and directed.
Material and labour for replacement PVC/Polycorbonate best quality junction boxes 40 mm size / Round plates 75 mm to 100 mm with suitable size screws - 02 Nos as per site requirements complete all as directed by Engineer-in-charge
Supply and fixing for replacement TPN DB 4 way Vertical Double door factory made powder coated suitable rated manufactureres busbar 415 Volts capacity for using MCCB as incomer and MCBs as out going circuits complete all as specified and directed by Engr-in-charge.
Supply and fixing for replacement SPN DB 12 way Double door factory made powder coated with 200 Amps rated busbar 240 Volts capacity for using MCBs as incomer and out going circuits complete all as specified and directed by Engr-in-charge.
Supply and fixing for replacement SPN DB 8 way Double door factory made powder coated with 200 Amps rated busbar 240 Volts capacity for using MCBs as incomer and out going circuits complete all as specified and directed by Engr-in-charge.
Supply and fix for replacement MCB SPN 32 Amp 240 Volts 10 KA C curve using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Supply and fix for replacement MCB SPN 63 Amp 240 Volts 10 KA C curve using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Supply and fix for replacement MCB SP 6 - 32 Amp 240 Volts 10 KA C curve using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Supply and fix for replacement MCCB 100 Amps 415 Volts 16 KA 4 pole using copper lugs for terminations complete all as specified and directed by Engr-in-charge.
Supply and fix for replacement lamp holder pin type pvc/polycarbonate type as per site in and including LED pin type 9 Watt LED lamp complete all as specified and as directed by Engineer-in-charge.
Material and labour for taking down unserviceable of ceiling fan sweep upto 1400 mm with blades and down rods etc from ceiling by unscrewing the nut bolts ,opening the split pin and keeping in safe custody for repairing and re fixing the same after repairs complete all as specified and as directed by Engineer-in-charge.
Material and labour for servicing of ceiling fan sweep upto 1400 mm complete on the site after inspecting all dismantled parts, complete erviceing and cleaning , greasing and removing all deposited materials and replacing following old parts and components with new ones and reassembling the same complete for smooth functioning complete all as specified and as directed by Engineer-in-charge.:- (a) Capacitor 2.5 mfd.- 01 No (b) PVC Capacitor Bracket - 01 No (c) Split pins complete for ceiling fan - 01 set
Material and labour for rewinding of ceiling fan motor complete of sweep upto 1400 mm after cutting the old unserviceable / burnt windindg with super enamelled copper winding wire of suitable gauge with connected bushes / bearings etc as applicable complete varnishing new winding drying up carefully complete all as specified and as directed by Engineer-in-charge.
Material and labour for taking down unserviceable of exhaust fan upto 450 mm sweep heavy duty with blades complete from existing positions using necessary louvers as applicable etc by unscrewing the nut bolts and keeping in safe custody for repairing and re fixing the same after repairs complete all as specified and as directed by Engineer-in-charge.
Material and labour for dismantling of exhaust fan of 300 mm sweep motor with louvers assembly for servicing after inspecting all dismantled parts for their serviceablity and cleaning , greasing and removing all deposited materials and replacing unserviceable parts and components with new ones and reassembling the same complete for smooth functioning by replacing the following spares:- (a) Capacitor 2.0 mfd.- 01 No. (b) PVC Capacitor Bracket - 01 No (c) Split pin for exhaust fan - 01 set
Material and labour for rewinding of metal exhaust fan motor complete of sweep upto 450 mm after cutting the old unserviceable / burnt windindg with super enamelled copper winding wire of suitable gauge with connected bushes / bearings as applicable complete varnishing new winding drying up carefully complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparing old painted surface of ceiling fan of sweep upto 1400 mm and spray painting with two coats of best quality synthetic enamel paint of approved properly, writing MES No on painted surface of fan complete all as specified and as directed by Engineer-in-charge.
Material and Labour for earthing Complete with GI earth platee electrode 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 2.25 M deep below normal ground level and complete earth plate connected to GI wire 4 mm by brazing only earth strip protected with light grade GI Pipe 15 mm dia bore from earth plate electrode and upto in and including the earth test point including 20mm bore water pipe medium grade GI Tubing including GI Funnel,wire mesh. alternate 5 layers of charcoal & salt crystal and removal of the excavated soil and depositing at the place where directed,PCC Pit in PCC (1:3:6) type C1 using 20 mm graded stone aggregate , RCC (m) Cover 40 mm thick in RCC (1:2:4) type B 1 using 20 mm grade aggregate reinforced with 8 mm dia TMT bars @ 7.5 mm c/c both ways including RCC Pit Cover etc watering the earth pit to acheive earth resistance below 02 Ohm incl testing complete all as specified and directed by Engineer-in-Charge.Note :- GI wire 4 mm,GI Tubing 15 mm light grade upto 7.5 mtr deemed to be included in the rate quoted by the contractor.
Supply, fixing, drawn GI wire 4 mm in GI pipe 15 mm pipe complete all as specified and as directed by Engr - in -charge.
Supply and fix GI pipe light grade 15 mm dia including on walls, roof / laid on floors, ground etc with all fittings for GI Wire protection all as specified and as directed by Engr - in -charge.
Checking of existingnCopper/GI strip/GI wire earthings of any type near all buildings using all safety methods carefully, tightening of all earthing connections, pouring water in the earth pits throgh earth pit funnel properly, after 24 hrs of water pouring testing of earthing pit using earth tester (The arrangement of earth tester is the responsibility of contractor), white washing to earth pit, marked/painted with exterior paint date of earth result checked, earthing pit pertains to which equipment etc and reading in ohms etc properly and enter earth details and results in the register duly signed by electrician in all respects complete all as directed by Engineer-in-charge. NOTE : 1) The job shall be paid twice in the contract period with interval of SIX months periodcity. 2) Earth work, demolition of PCC,PCC new work, RCC earth pit cover and GI strip as applicable shall be measured and paid separately under relevent item.
Demolition and dismantling of old/damaged concrete of any description near existing buildings of any type located at various locations carefully removing from site and making good distrubed portions near buildings to match with the adjacent areas in all respects as per site conditions complete all as directed by Engr-in-charge.
Material and labour PCC for foundation near existing earthings of any type etc 1:3:6 type C-1 (20 mm graded aggregate) complte all as specified and directed Engr - in - charge.
Supply and fixing for replacement earth pit cover slab RCC 40 mm thick in RCC (1:2:4) type B 1 using 20 mm grade aggregate reinforced with 8 mm dia TMT bars @ 7.5 mm c/c both ways including testing arrangements and taking out old broken covers complete as per site requirements all as specified and directed by Engineer-in-charge.
Material and labour for replacement Air termination single pointed aluminium rod 12 mm dia and 300 mm long complete on building roof in and including PCC block as per site conditions complete all as directed by Engineer - in - charge.
Material and labour for replacement aluminium strip 25 x 3.15 mm with insulators heavy duty, fxing screws etc for roof and down conductors complete all as per site conditions in and including using necessary tools, plants and ladders complete all as specified and directed by Engineer-in-charge.
Material and labour for replacement GI Earth Strip 32mm X 6mm burried in ground / fixed on wall / floor as per site requirement for purpose of Beyond 7.5 meter for earthings / lightning buried strip etc as per site conditions complete all as specified and directed by Engineer-in-charge.
Material and labour for replacement earthing Complete with GI earth platee electrode 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 2.25 M deep below normal ground level and complete earth plate connected to GI strip of size 32 x 6 mm by brazing only earth strip protected with light grade GI Pipe 50 mm dia bore from earth plate electrode including 20mm bore water pipe medium grade GI Tubing including GI Funnel,wire mesh. alternate 5 layers of charcoal & salt crystal including excavation in strata, refiling and removal of the excavated soil and depositing at the place where directed,PCC Pit in PCC (1:3:6) type C1 using 20 mm graded stone aggregate , RCC (m) Cover 40 mm thick in RCC (1:2:4) type B 1 using 20 mm grade aggregate reinforced with 8 mm dia TMT bars @ 7.5 mm c/c both ways including suitable RCC Pit cover etc watering the earth pit to acheive earth resistance below 02 Ohm incl testing complete all as specified and directed by Engineer-in-Charge. Note :- (1) Quoted rate deemend to included necessary earth work PCC chamber, RCC cover, renforcement removal of surplus soil , site clearance etc. (ii) GI earth strip 32X6 mm , GI tubing light grade 50 mm dia upto 7.5m deemed to be included in the rate quoted by the contractor.
Fixing only properly GI/Aluminium earth Strip of any type by taking down carefully from the existing locations of buildings i.e roof/wall / floor etc in and including using nuts bolts and washers / soldering works as per site requirements all as specified and directed by Engineer-in-charge.
Sahara Engineers (BID ID -3123445)
Pacific Enterprises (BID ID -3113989)
GS TRADERS (BID ID -3125933)
Vishwas Enterprises (BID ID -3114588)
Vasavi Electricals (BID ID -3115907)
Anjali Constructions (BID ID -3111989)
NAVEEN ENTERPRIESES (BID ID -3115676)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .