Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.6 L+₹1.6 L (12.6%)Rejected-Finance MAIN BAZAR SURANKOTE DISTT POONCH 185121 J K | SURANKOTE | POONCH | J K | 185121 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
14 Oct 2022, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
SPL REPAIR TO STATIC WATER TANK P-16 AND SPL REPAIR OF CONNECTING CABLE, LT POLE AND SECURITTY LIGHT INFRA ALONG PERIMETER AT K NALLAH UNDER GE 881 EWS
2022_MES_552371_1
GE/PNH-51/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹36,000
Yes
27 Dec 2022
16 Sept 2022
21 Oct 2022
16 Sept 2022
14 Oct 2022
1 Oct 2022
Amount
B&R PORTION:- Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed.
M&L for 100mm thick plain cement concrete 1:2:4 type B-1 (20mm graded crushed aggregate) as in sub floor, sub bases, flooring, paving etc finishing surface even & fair, complete all as specified and directed
M&L for rendering 20mm thick on fair faces of brick or concrete surfaces in cement mortar 1:3 with mixing of liquid water proofing compound @ 0.2 litre per 50 kg of cement and finished the surface even and smooth without using extra cement, complete all as specified and directed. Note: WPC shall be measured and paid separately
S&F GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and directed.
M&L for preparation of newly plastered / unplastered surfaces of wall including cornices pilaster etc, and applying two coats of cement base paint complete all as specified and directed.
M&L for plain cement Concrete 1:2:4 type-B1 (using 20mm graded crushed stone aggregate) as in copings, hold fasts plinth band, bed blocks and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified and directed.
M&L for 50mm thick PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
E&M PORTION:- Dismantling of PCC/ steel pole of any type and size, complete all as specified and directed.
Supplying, installation and errection in true vertical position steel tubular swaged welded pole, 8.5 metre long, conforming to IS-2713 part-II, type 410 SP-22, complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial taper, pole cap, bolts, nuts, washers & screws etc., pole made out of ERW Mild steel tubing tubing including holes of required Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bands at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No with black paint by stenciled letters/figures of 8cm height, fixed as in repairs complete all as specified and directed. Note: Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately in respected items.
M&L for dismantling of ACSR conductors and removing from the site complete all as specified and directed.
Supply, stringing, stretching and binding with insulator, ACSR conductor on poles (Weasel /ferret/Mink) including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc complete all as specified and directed. Make: ICC/NICCO/JAIPURIA/ALUMINIUM IND
M&L for dismantling of insulator of any size and removing from the site complete all as specified and directed.
Dismantling of cross arms, bracings, supports, clamps etc of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed.
M&L for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed.
S&F Shackle type porcelain , vitreous white, brown or green insulator including galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 75 mm height, 90 mm dia for working pressure 1100 volts grade of LT line complete all as specified and directed. Make: PACTIL/BHEL/JAIPURIA/MASORE PORCILAIN
S&F pin type insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volt grade, complete all as specified and directed. Make: PACTIL/BHEL/JAIPURIA/MASORE PORCILAIN
Supply, laying and testing of cable in trenches/ poles XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 3.5 core 25 sqmm including taking down old cable any type complete all as specified and directed.
All as per Srl item No. 19 Above but of size 16 sqmm 4 core complete all as specified and directed.
All as per Srl item No. 19 Above but of size 16 sqmm 2 core complete all as specified and directed.
Supply and fixing in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and prewired including conductor to fitting with 3 core 1.5 sqm PVC insulated cable with PVC conduit pipe from junction box to light fitting complete all as specified and directed. Make : Havells cat part ENDURAPEARLNEOSL60WLED757PASYTOPCAST or equivalent make as specified in PS
S & F in replacement street light house service bracket (hook type) complete with 1.5 mtr long GI pipe 40 mm dia light grade, bent to shape as dirrected, incl suitable MS clamp of FI 50mm x 6mm with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint complte all as specified and directed.
Supply, fixing, testing & commissioning of LT weather vermin proof panel board powder coated with locking arrangement, outdoor type, double door type feeder pillar board factory fabricated cubical kiosk type, made out of MS sheet 3.15 mm thick of suitable size of channel for base complete with 200 amps rated bus bar 32 mm thick chamber and cabinet for house mounting switch disconnection fuse unit metering equipment prewired with suitable size of copper conductor and duly painted with one coat of red oxide primer and two coats of synthetic enamel paint and internal wiring including PCC work, 0.6 Mtr above ground level, grouting etc including provision of suitable size of cable glands, cable lugs,nut, bolts,washers etc. (The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron), including taking down old panel board, complete all as specified and directed and comprising of the followings:-
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and exc. 1.5m in depth for foundation of poles, stay assembly etc and getting out in hard/ dense soil complete all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in surplus spoil including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
M&L for Sand cushioning to under ground cable providing with a layer of Sand 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : Punning thickness of 18 cm will be measured for payment purpose)
M&L for Burnt bricks locally available, sub class 'B', laid flat for protection of under ground cable complete all as specified and directed at site.
S&F thermo plastic street light weather proof outdoor type junction box of size 200mm x 160mm x 98 mm complete with 4 way connector-01 No., SP MCB 6 amp-01 No, having easy openable and locking arrangement incl incoming and outgoing cable holes and incl taking down old unsv junction box complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation of pole, stay and mass concrete complete all as specified and directed.
M&L for Plain cement concrete (1:2:4) Type B-1 using 20 mm graded crushed stone aggregates, as in coping of steel tubular poles foundation for steel tubular poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
S&F in repair 1100 Volts grade heavy duty cable PVC insulated aluminum solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular, size of aluminum conductor 6 sq mm, complete all as specified and directed.
S&F in repair Stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick, GI stay rod with nuts 215cm long, 20mm dia, MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 90mmx140mm clearance of hole 25.5 mm & other accessories all as per SSR Part-1, Plate No.1 including necessary MS clamps, excavation earth work & PCC work complete all as specified and directed.
Supply and fixing in repair galvanised stay strand, size 7/3.15 mm for connecting stay assembly with MS clamps on poles complete all as specified and directed.
Supply and fixing loop insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, large size with overall dimensions 90mm x 140mm, clearance of hole 25.5 mm, Complete all as specified and directed. Make: PACTIL/BHEL/JAIPURIA
S&F in replacement of GI pipe light grade 40 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps, nuts bolts etc complete all as specified and directed.
M/S KIRAN CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .